| 1 | Demolition of existing old tarfelt, water proofing membrane including roof tiles, cement mortar screed, concrete base of any thickness and roughing surfaces to receice roof treatement including removal of debris from MoD land, complete all as specified and directed. |
| 2 | Rendering 15mm thick cement plaster with cement mortar(1:3) onfair finishes of brick work or concrete surface of roof slab, using WPC to be measured seperately under relevant item in schedule complete all as specified and directed. |
| 3 | Supply only integral water proofing compound |
| 4 | Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course: Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course :APP (Atactic Polypropylene) modified polymeric membrane, 5 layered,3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @200ml/bag of cement and curved before laying of membarance.(c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions.(ii) Covered fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6).Note : (i) Quoted rates are inclusive of all of the above work.(ii) Water proofing treatment shall only be carried out by the authorised personal of the Company and proper record of the same shall be maintained. |
| 5 | PCC 1:2:4, B-1 (20mm graded crushed stone aggregate) as in copings, hold fasts, plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified and directed |
| 6 | Sunken Floor treatment :- Taking down old treatment/ floor tiles/ PCC and Providing & laying of water proofing treatmentto sunken portion including vertical portion by applying cement slurry mixed with acrylic based polymer modified cementitious composite compound of make as approved including demolition and filling of sunken floor.(a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours.(b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/ Sqm his layer allowed to air cure for 4 Hours.(c). 50mm thick PCC at the bottom of slab and slopeshall be 1:20 toward the corner of outer wall and GI pipe of 50mm dia (Med grade) be inserted at corner projecting outside 20 cm . (d).15 mm thick plaster in CM 1:3 mixed with WP Compound shall be provided while concrete is green.(e) Joints of trap/WC/Soil pipes shall be properly sealed with sealing compound.Note :- (i). Concrete for sunken slabs shall be mixed with WP compounds asmanufacturdrs instructions before carrying out water proofing treatment the sunken slabslab shall be tested with water for 48 hrs for any leakage/dampeness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested (Water proof compound rate will not be paid separately).(ii).Only floor area shall be measured for payment purpose.(iii). Treatment shall only be done from approved manufacturer & name of manufacturer required to be approved from GE before treatment. |
| 7 | Demolition of brick work or stone boulder masonarybuilt in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and directed. |
| 8 | Brickwork with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius built in cementsand mortar 1:6 complete all as specified and directed and directedand directed |
| 9 | Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius built in cementsand mortar 1:4 in half brick thick wall complete all as specified and directed |
| 10 | Taking down cement plaster of any description on stone or brick walls etc. including racking out joints, hacking for key scrubbing down with water etc.complete all as specified and directed |
| 11 | Rendering 10mm thick cement plaster with cement mortar(1:4) onfair finishes of brick work or concrete surface and finished even and smooth without using extra cement all as specified and directed. |
| 12 | Rendering 15mm thick cement plaster with cement mortar(1:4) onfair finishes of brick work or concrete surface with water proofing compound and finished even and smooth without using extra cement all as specified and directed.Note: WPC to be paid seperately. |
| 13 | Rendering 15mm thick cement plaster with cement mortar(1:6) onfair finishes of brick work or concrete surface and finished even and smooth without using extra cement all as specified and directed. |
| 14 | Preparation of newly plastered surfaces of walls and applying two coats of exterior emulsion ( weather coat) over a coat of alkali resistant primer, complete all as specified and directed |
| 15 | Preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion, complete all as specified and directed . |
| 16 | Complete removal of existing treatment inclold painted surfaces and applying two coats oil bound distemper to walls complete all as specified and directed. |
| 17 | Preparation of newly plastered surfaces of ceiling and applying two coats ofoil emulsion distemper, complete all as specified and directed |
| 18 | Preparation of old decorated wall incl washing, rubbing down and stopping of old painted surfaces and applying two coats of distemper oil emulsion to walls complete all as specified and directed. |
| 19 | Complete removal of existing treatment incl washing, rubbing down and stopping of old painted surfaces and applying two coats of exterior emuslion (weather coat) paint to walls complete all as specified and directed |
| 20 | Floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length of cover plate 140mm as in repair , all as specified and directed. |
| 21 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and directed |
| 22 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed. |
| 23 | Dismantling of stone slab and tiles of any description or thickness in floor apron etc laid or bedded in any mortar complete all as specified and directed. |
| 24 | 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over with mirror cut polishing 100mm wide marble patti/border all around over and including 15mm thick screed bed in cement and sand mortar 1:4 complete all as specified and directed and directedand as directed.Note:-(Size of Kota Stone slab shall be 52 cm x 52 cm). |
| 25 | Ditto all as per Item No 24 here-in-before but as skirting including 10mm thick plaster in CM 1:6 complete all as specified and directed . |
| 26 | Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc.set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15 mm thick screed bed in cement and sand mortar 1:6,complete all as specified and directed. |
| 27 | Glazed ceramic coloured tiles 450x300x7mm thick on vertical surfaces such as skirting, dados and risers to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick rendering in CM 1:4 finished even and fair to receive tiles, complete all as specified and directed. |
| 28 | Granite flooring (of any type) 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, moulding & polishing laid over & including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 29 | Providing cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate), 50 mm thickas in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight), complete all as specified and directed . |
| 30 | Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqcm in width or girth & applying rendering 15 mm thick dubbing coat where required to match with the existing thickness in CM 1:4including formwork/scaffolding work upto height 7.00mtr & applying two coats of exterior emulsion weather proof paint (Apex) as reqd over one coat of primer above ground level of bldg complete all as specified and directed . |
| 31 | Taking down chowkhats or frameswith shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and directed. |
| 32 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each complete all as specified and directed. |
| 33 | Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing, complete all as specified and directed. |
| 34 | Factory made solid panel PVC door shutter/ cupboard shutter/ kitchen cabinets 30mm thick style wooden texture consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading andjointed together with solvent cement supply & fixing in the frame at site, complete all as specified and directed |
| 35 | Anodised aluminium framed powder coating for doors ,windows ,coating,ventilators/fixed partition/grill etc with or one more rebates including joining cleat for fixing etc complete all as specified and directed |
| 36 | 04 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and directed |
| 37 | Powder coated anodised aluminium window / ventilator( glazed / gauged skeleton shutter ), (minimum thickness of powder coating 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m includingnecessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinges type B-21 100mm long (2 No. ) suitable handle (1 No.) complete all as specified and directed and directedand as directed. |
| 38 | Pressed steel frames for doors with one or more rebates of size 125x60mm including necessary fixing lugs, hinges, lock strike plates complete, providing mild steel 6 mm dia thresh hold bar complete all as specified and directed and directedand as directed. |
| 39 | PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in back filling of pressed steel and in parapet coping, complete all as specified and directed and directed |
| 40 | 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 41 | 35mm thick 2nd class hard wood Glazed and Skeleton shutters, open rebated and prepared to receive glass, gauge etc devided into square with sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed . |
| 42 | Pre laminated particle board, in18/19 mm thick prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as cupboard shelve and shutter in repair. (Kitchen cup board/covered bottom shelf of cooking platform) fixed in repairs complete all as specified and directed |
| 43 | Intermat auto closing concealed hinge, complete all as specified and directed . |
| 44 | Premium quality crome finish Handle 6\",complete as specified and directed. |
| 45 | Telescopic channel set for drawer multi-tech high capacity 500 mm long as approved complete all as specified and directed |
| 46 | Telescopic channel set for drawer multi-tech high capacity 500 mm long as approved complete all as specified and directed |
| 47 | 03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and directed |
| 48 | Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed. |
| 49 | Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and directed . |
| 50 | 150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed |
| 51 | Aluminium handle cast type anodised of size 150mm long ISI marked complete all as specified and directed. |
| 52 | Aluminiumanodised sliding door bolts with hasp and stapple extruded sectionor cast aluminium alloy with length of bolt as 300 mm including fixing bolts complete all as specified and directed. |
| 53 | 300mm Mild steel ordinary rat tail helical door springs including roller and roller plate fixed, complete all as specified. |
| 54 | Floor door stopper of aluminum alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length of cover plate 100mm as in repair , all as specified and directed. |
| 55 | Curtain rod ,20 mm dia Stainless steel ,chromium platedfixed with CP bracket, incl taking down of old curtain rods, complete all as specified and directed. |
| 56 | Preparation new steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 57 | Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paintof Ist quality over a coat of pink primer,complete, all as specified and directed. |
| 58 | Vitreous china squatting pan \"Orissa Pattern\" size 550 x 440 mmin white colour with integral foot rest incl lime mortor, \"P\" trap fixed in repairs, incl making good dismantled floor with PCC 1:2:4 B-0, complete all as specified and directed |
| 59 | Pillar tap of 15mm bore dia fancy type capstan heads, chromium platedscrewed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipein repairs as complete all as specified and directed and directedand directed. |
| 60 | Chromium Plated stainless steel towel rail 20mm dia \"D\" type 60 cm longbetween flanges complete all as specified and directed |
| 61 | CP angle valve/stop cock (weight not less than 0.40Kg of cast copper alloy (ISI Marked) chromium plated fancy type screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore in repairs and complete all as specified and directed |
| 62 | 15 mm CP Bib taps (Long body and weight not less than 0.40Kgfancy type chromium platedwith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule in repairs and complete all as specified and directed |
| 63 | S&F in repairs kitchen utensil rack in steel made of premium grade stainless steel and highly durable and rust-proof of size not less than 90cmx80cmx20cm complete all as specified and directed. |
| 64 | Stainless steel kitchen sink (with out drainage board) (1mm thick) kitchen or laboratory withplugs, washers and waste pipe & couplings including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting and conecting union to pipe over all size 915mm x 460 mm bowl size 410 mm x 330 mm x 160 mm fixed in repairs complete all as specified and directed. |
| 65 | 600mm x 450mm size bevelled edge mirror with border, selected quality 5mm thick glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repairs complete all as specified and directed |
| 66 | Single lever sink mixture with popup waste system with 450 mm long braided hoses fixed in repairs all as specified and directed. |
| 67 | Supply only PVC connection 15mm size with PTMT nuts on both ends of length 600mm complete all as specified and directed. |
| 68 | Stainless steel gratings 100/125mm dia fixed with cement motar fixed in repairs, completeall as specified and as directed. |
| 69 | S&F in repair waste pipe for SINK/WHB/Urinal for 32/40mm dia all as specified and directed. |
| 70 | Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc complete all as specified and directed |
| 71 | Taking up or down steel tubing and connections, 20 mm bore fixed on walls, floors or ceiling etc complete all as specified and directed |
| 72 | Mild steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and directed |
| 73 | Mild steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and directed. |
| 74 | Rotational moulded polyethylene 03 layer water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and directed |
| 75 | Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe20 mm dia (minimum weight 210 gms) complete all as specified. |
| 76 | 20mm bore gun metal glove or gate valve with iron wheel head screwed both end for iron pipe and fixed in repairs,complete all as specified and directed |
| 77 | Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), including all fittings, heads , shoes bends, swan-necks etc .including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed |
| 78 | 110mm diaPVC (SWR) Type-B pipes single socketed in any length with rubber ring joint laid in trenches or in floor all as specified and directed |
| 79 | 75 mm diaPVC (SWR) Type-B pipes single socketed in any length with rubber ring joint laid in trenches or in floor all as specified and directed |
| 80 | 110mm diaPVC (SWR) Type-B pipes single socketed in any length with rubber ring joint laid in walls all as specified and directed |
| 81 | 75 mm diaPVC (SWR) Type-B pipes single socketed in any length with rubber ring joint laid in walls all as specified and directed |
| 82 | PVC SWR bends any radius 110 mm bore incl access door, completeall as specified. |
| 83 | PVC (SWR) bends any radius 75mm dia complete all as specified and directed . |
| 84 | PVC (SWR) 110mmjunction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door all as specified and as directed. |
| 85 | 75mm bore PVC SWR bends fixed with acess doorall as specified and directed. |
| 86 | PVC (SWR) 75mmjunction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch all as specified and as directed. |
| 87 | PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement in repairs complete all as specified and directed. |
| 88 | PVC SWR branch piece 110mm bore single (single Y) equal or unequal ordinary or inverted (spigot or socket type) all as specified and directed. |
| 89 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition) complete all as specified and directed . |
| 90 | PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate), as in cover slabs/shelf etc, complete all as specified and directed |
| 91 | TMT bars, 8 mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed |
| 92 | Precast factory made chequered designer cement concrete tiles (Rectified interlocking tiles)250x250/300x300 mm 25 mm thicksetand jointed in neat cement slurry with mixture of white and grey cement (colour and pattern as per sample kept in GE office as approved by GE) over and including 15 mm thick screed bed in CM 1:4 all as specified and directed. |
| 93 | PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, finished fair & even complete all as specified and directed |
| 94 | PCC 1:2:4 type B-0 (Using 12.5 mm graded crushed stone aggregate) as in filling of roof kerbs or pressed steel frame as inparapet coping, roof kerbs or in lintels upto 1.5 m clear span, cills, plinth courses, string courses, coping, kneelers etcall as specified and directed. |
| 95 | Demolition and breaking up drain pipe 150mm dia (salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar/concrete complete all as specified. |
| 96 | Excavation in trenches not exceeding1.5 m wideand not exceeding 1.5 m deep for laying cable or foundation including gettingout in any type of soil complete all as specified and directed and directedand directed. |
| 97 | PCC 1:2:4, type B-1 (20mm graded crushed stone aggregate) as in copings, hold fasts, plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified. |
| 98 | Plain cement Concrete 1:3:6 type-C2 (using 40mm graded crushed stone aggregate) as in bed including packing under,and haunching against the sides of pipe after they laid and tested for 150 mm complete all as specified. |
| 99 | RCC classNP3 150mm dia drain pipes laid in trenches and jointed with & including coller complete all as specified and directed |
| 100 | Returning filling including spreadingwateringand well ramming in layers not exc25cmcomplete all as specifed and directed. |
| 101 | Removing surplus soilto distance not exceeding50 m and depositing where directed at a level notexceeding 1.5 m above the starting pointcomplete all asspecifiedand directed . |
| 102 | Surface excavation n exc 30cm deep and averaging 15 cm any type of soil all as specified and directed. |
| 103 | Ditto as per item no. 102 above but depth exc 15 cm but n.exc 17 cm all as specified and directed. |
| 104 | PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 105 | Reinforced cement concrete Design Mix (M-25) (using 20 mm graded crushed stone aggregate) as in cooking platforms,slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed |
| 106 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed. |
| 107 | Ditto as per item no 106 above,but 5mm dia over upto and including 10 mmm stirrups,spacer,binder |
| 108 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Vertical , Horizontal or sloping)sidesincluding sup- ports, overhangs,for fair finished surface of concrete etc. complete all as specified and directed . |
| 109 | Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, complete all as specified and directed. |
| 110 | PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in in foundation,filling and ,mass concrete complete including finishing the surface of concrete topping even & fair, complete all as specified and directed. |
| 111 | Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to better with rough finished surfaces of concrete complete all as specified and directed. |
| 112 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of square rectangular or polygonal concrete all as specified and directed. |
| 113 | Reinforced cement concrete Design Mix (M-25) (using 20 mm graded crushed stone aggregate)in Columns, pillars, piers, posts and strutscomplete all as specified and directed. |
| 114 | Mild steel framed workas in door or gate of angle or other section with gusset plate, rail braces complete drilled for fixing of steel sheeting or other covering . door etc to be prepared for hanging of sliding with grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-410-W(Gde-E-250) quality-B, complete all as specified and directed . |
| 115 | Mild steel work in tubular trusses, purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St.-240 including notching, drilling, fitting, riveting and or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc also for wedging, plumbing, turning up & fixing complete all as specified and directed |
| 116 | Mild steel screw bolts 10mm dia at neck, machine made, with hexagonal or square heads at one end and screwed the other, or screwed both ends; each screwed and to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long, complete all as specified and directed |
| 117 | Pre- painted galvanised aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 118 | Pre- painted galvanized aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 119 | Broken stone boulder hardcore of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface, complete all as specified and directed. |
| 120 | 150 mm thick cement concrete type D-2, 1:4:8 (40mm graded crushed stone aggregate) as in sub base of floors finished even & fair, complete all as specified and directed |
| 121 | 50 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in sub base tofloor & finishing surfaces even and rough, complete all as specified and directed |
| 122 | Forming contruction joint 30mm deepx 10 mm wide filled with sealing compound of grade \"A\" all as specified and directed. |
| 123 | Forming contraction(Dummy joint)joint 50mm deepx 10 mm wide filled with sealing compound of grade \"A\" all as specified and directed. |
| 124 | PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in Surface channel and drains complete including finishing the surface of concrete topping even & fair, complete all as specified and directed. |
| 125 | Extra for forming fair finished to drain channel not exc 30 cm inner girth in cement concrete using extra cement complete all as specified and directed |
| 126 | Ditto as per item no 121 but 25 mm girth or part there of under 30 cm all as specified and directed |
| 127 | Mild steel framed workas in grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290. Gde E-165, complete all as specified and directed. |
| 128 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed |
| 129 | Point wiring complete with 1.5 sqmm PVC insulated, FRLSHtype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLSHtype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directed and directedand directedfor theOne light point/fan /bell pointcontrolled by one switch.(Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers are to be used of same make/brand onlyand shall be deemed in to included in quoted rate only.) |
| 130 | One light point controlled by one switch |
| 131 | One 3 pin 5 amps socket point controlled by one 5 amps switch on independent board |
| 132 | One 3 pin 5 amps socket point controlled by one 5 amps switch on same board |
| 133 | All as per item No 126 above but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed and directedand directed for the following:- (a) One 6 Pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board. |
| 134 | Modular type switch 10 Amps, single pole,1way,1 module,240V, ISI Markedcomplete all as specified and directed |
| 135 | Modular type switch 16 Amps, single pole, 1way,1 module, 240V, ISI Marked complete all as specified and directed |
| 136 | Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked complete all as specified and directed |
| 137 | Modular type socket 16 Amps, 2/3 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Markedcomplete all as specified and directed |
| 138 | Angle lamp holder, insulated body with back plate for LED lamp including removing old unsv itemcomplete all asspecified and directed. |
| 139 | Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 140 | LED light fitting 1x10W, 4 feet, 220V, general purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver LED fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose as approved by GE fixed in repairs complete all as specified and directed |
| 141 | LED light fitting 1x10W, 2 feet, 220V, general purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver LED fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose as approved by GE fixed in repairs complete all as specified and directed |
| 142 | LED INVERTER batten 20 watt 4 feet with square profile and poly carbonate channel lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hoursand connecting up with twin core twisted copper wire from LED fitting to ceiling roseand removing old unserviceable fitting complete all as specified and directed |
| 143 | LED bulb 12 watts, 240Volts,50Hzpin type andincluding removing old unserviceable itemcomplete all as specified and directed |
| 144 | LED secruity light fitting of capacity25 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionwith suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and testing and including removing of old unserviceable item complete all as specified and directed |
| 145 | Supply & fixing in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board 8 way suitable for flush mounting with 100amps copper busbar,neutral bar,earth barand MCB incomer of rating upto 100Amps ,MCB SPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat all as specified and as directed. |
| 146 | MCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked fixed in repairs complete all as specified and directed |
| 147 | MCB single pole & neutral 40 to 63 amps 240 volts 10 KA \"C\" series fixed in repair, complete all as specified and direcetd. |
| 148 | Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. |
| 149 | Exhaust fansingle phase PVC/Sturdy engineering plastic body 230V 50 Hz of size 250mm sweep ISI marked with louvers shutter complete with all accessories including connecting up from ceiling rose complete ncluding exhaut saking down old U/S all as specified and directed. Note: The Old unsvare fan shall be deposited in MES yard. |
| 150 | Exhaust fansingle phase metal body, AC 230 Volt, 50 Hz, 1200 RPMof size 300mm sweep with louvers shutter complete with all accessories including taking down old u/s are connecting up from ceiling rose complete all as specified and directed . |
| 151 | Sub main wiring complete with 2 runs of 2.5 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLSH type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn throughrigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSHtype as earth continuity conductor connected to common earth dollyincluding making good the disturbed surfaces to match with existing surface including taking down of old existing submain cable complete all as specified and directed and directedand directed. Note : - Two run of 4 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 152 | Sub main wiring complete with 2 runs of 4 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLSH type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn throughrigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSHtype as earth continuity conductor connected to common earth dollyincluding making good the disturbed surfaces to match with existing surface including taking down of old existing submain cable complete all as specified and directed and directedand directed. Note : - Two run of 4 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 153 | Sub main wiring complete with 2 runs of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLSH type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn throughrigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSHtype as earth continuity conductor connected to common earth dollyincluding making good the disturbed surfaces to match with existing surface including taking down of old existing submain cable complete all as specified and directed and directedand directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 154 | Ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1200mm sweep, min air delivery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) incl taking down existing and deposit with MES store yard all as specified and directed. |
| 155 | Vertical double door TPNin replacementand fitted with Bus bar neutral link, blanking plates of 4 way(4+12) with suitable for incomming MCCB 4 pole\"G\" frame,having isolated neutral bar, mechanical impact strength IK09, door earthing suitable for MCCB upto 125 Amp, complete all as specified and directed and directedand directed. |
| 156 | MCCB 04 pole 415 volts 16 KA, 125 Amp adjustable thermal & fixed magnetic setting type suitable for TPN vertical loadline DB mentioned at ser No 151 here in before fixed in replacement, complete all as specified. |
| 157 | Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed.Note: Old unsv geyser shall be deposited in MES yard. |
| 158 | Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and directed and directedand as directed. |
| 159 | Double wall corrugated (DWC) HDPE tubing 100 mm bore for open/underground laying cable, cut to size and making thetubing forcable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed and directedand directed by Engr-in-Charge. (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate.(b) The insulation of DWC pipe should be of high that does not deteriorate withUV rays/ heavy sun rays/winter season etc.(c)Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates |
| 160 | GI water tubing in replacement25mm bore \"medium grade\", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and directed |
| 161 | 25 mm bore gun metal glove or gate valve with iron wheel head screwed both end for iron pipe and fixed in repairs,complete all as specified and directed |
| 162 | Taking down unsv PCC poles and M&L for steel tubular swaged pole type 410 SP-31 (9 metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5M from ground level/coping, complete all as specified and directed |
| 163 | LED secruity light fitting of capacity60 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionwith suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and testing and including removing of old unserviceable item complete all as specified and directed . |
| 164 | Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 35 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and directed |
| 165 | Supply and fixingweather proof flattwin Core PVC insulated & sheathedAluminium stranded conductor cables1.5 sqmmdrawn through street light pole duly making the hole upper and down both place and connection the street light to DB Boxall as specified and directed. |
| 166 | Bracket made out of 40mm x 5mm Angle iron 1.5 meter long both end hole for fixing of street light including M & L for MS clamps, back plates fabricated from structural steel section 50 x 6mm, including nuts, bolts, washers, welding cold bit, drilling of holes for bolts, in any shape or size including two coats of Aluminium paint over a coat of Red oxide primer after preparation of steel surfaces, holding Angle iron in complete all as specified and directed and directedand directed |
| 167 | Loop in and Loop Out box pole mounted outdoor type Hot press Moulded SMC Junction Box of inside dimension not less than 300x300x150 mm and outer dimension of 400x400x200mm with locking arrangement suitable for 240 V 50 Hz including MCB SP of 6 Amp cap, fixing with 4 Nos Aluminium busbar of 30 Amp rating for three phase with neutral, painted with powder coating in siemens grey colour including clamp for fixing with steel pole all as specified and directed |
| 168 | Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and directed and directedand as directed. |
| 169 | Supply and fixing of Double wall corrugated (DWC) HDPE tubing 50 mm bore for open/underground laying cable, cut to size and making thetubing forcable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed and directedand directed (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate.(b) The insulation of DWC pipe should be of high that does not deteriorate withUV rays/ heavy sun rays/winter season etc.(c)Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates |
| 170 | Supply, fixing and testing High pressure pump for high pressure wash Max pressure 200 bar, power 3000 watt, flow rate 15 ltr/min, 5HP motor 220-230V and 1400 RPM complete all as specified and directed and directed |
| 171 | Supply and fixing and testing of DOL starter (MN-16) suitable for 5HP 3 phase pressure pumps complete all as specified and directed and directed |
| 172 | Supply and fixing heavy duty hose pipe flexible of size 3/4\" for car washing pressure pump complete all as specified and directed and directedand directed. |
| 173 | Supply and fixing heavy duty brass water jet spray Nozzle of size 3/4\" alongwith clamp and fixing arrangement complete all as specified and directed and directedand directed. |
| 174 | MCCB 04 pole 415 volts 16 KA 63 Amp adjustable thermal magnetic setting type with lugs of size 35 Sqmm complete all as specified. |
| 175 | Supply, fabrication and fixing feeder pillarbox of size 500x 450x500 mmmade out of MS sheet of 3.15 mm thick bent to shape & size factory made with welding, bending works suitable for including 200 Amps ratedaluminium bus bars (length of bus bar not less than 40 cm) 4no\"s ,makingholes of any size and mounted on porcelain/epoxy based post insulators of appropriate sizewith suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and length of angle iron not less than 1 mtr, 0.5 mtr to be embeded in PCC below G.L and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping. |
| 176 | Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed |
| 177 | Sand cushioning to under ground cable, 8 cms thick before laying the cable and 15 cms thick after laying and stretching the cable in trenches including hand punning and consolidating, punned to 18cm thickness, complete all as specified and directed |
| 178 | Supply and fixing in replacement for post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. complete all as specified and directed |
| 179 | Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 4 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail