| 1 | SCHEDULE \"A\" PART-I : BOQ OF WORKS FOR B/R WORKS. |
| 2 | Dismantaling of brickwork or stone/ boulder masonry, including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar of any description, complete all as specified and as directed. |
| 3 | Excavation over areas, not exceeeding 1.50 mtrs deep and getting out in any type of soil, complete all as specified and as directed. |
| 4 | Excavation over areas, exceeeding 1.50 mtrs but not exceeeding 3.0 mtrs deep and getting out in any type of soil, complete all as specified and as directed. |
| 5 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation filling, complete all as specified and as directed. |
| 6 | Reinforced cement concrete, design mix M-30 (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc and mass concrete, complete all as specified and as directed. |
| 7 | Reinforced cement concrete, design mix M-30 (using 20mm graded crushed stone aggregate) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilastersandbuttresses, complete all as specified and as directed. |
| 8 | Formwork, use and waste type, to the faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, to get fair finish surfaces of concrete, complete all as specified and as directed. |
| 9 | Formwork, use and waste type, as in sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to get fair finish surfaces of concrete, complete all as specified and as directed. |
| 10 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 11 | PVC (SWR) pipes, 110mm bore, single socketed, capacity not, less then 4.50 Kgf/Sqcm, in any length fixing with adhesive/ solvent cement, fixed in wall as weep holes, complete all as specified and as directed. |
| 12 | Hand packing broken stone or boulders (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and as directed. |
| 13 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed. |
| 14 | Plain cement concrete M-15(1:2:4), type B-0, (using 12.50mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, bed plates, including necessary form work, complete all as specified and as directed |
| 15 | Removing excavated soil (materials) not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed. |
| 16 | Hardcore of broken stone or boulders gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 17 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), 100mm thick, as in sub base, finish even and smooth without using extra cement, complete all as specified and as directed. |
| 18 | Cement concrete work in pavement/ hard-standing of flexural strength 40 Kg/ per square centimetre in field using 400 Kg of cement per cubic metre, thickness of concrete 25Cm or less, complete all as specified and as directed. |
| 19 | Forming Contraction (Dummy) joints 65mm deepx10mm wide, for thickness of concrete slab of 200mm, filled with sealing compound grade ‘A’, complete all as specified and as directed. |
| 20 | Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, for thickness of concrete slab of 200mm, complete all as specified and as directed. |
| 21 | Finishing surface of concrete roads, pavements, by brooming, complete all as specified and as directed. |
| 22 | Anodised aluminium snap grid frame work for false ceiling, powder coated, comprising of aluminium Tee (weight of section not less than 280 gms/mtr) and aluminium angle (weight of section not less than 280 gms/mtr), grid size 605x605mm, includingHangers 6.0mm dia, galvanised iron (upto1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3 mm size 60mm long and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed. |
| 23 | Providing and fixing everest board 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, grid size 595x595mm, for false ceiling all as specified, complete all as specified and as directed. |
| 24 | Providing and fixing Gypsum Board 12mm thick in ceiling fixedwith screw as per manufacturers instructions, for false ceiling all as specified, complete all as specified and as directed. |
| 25 | PVC sheet fillet 5mm thick of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and as directed. |
| 26 | Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and as directed. |
| 27 | SCHEDULE \"A\" PART-II : BOQ OF WORKS FOR E/M WORKS. |
| 28 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed. |
| 29 | Point wiring (in new concealed conduits to surfaces as required at site) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including any type of new conduit, of any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed.Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate. |
| 30 | Modular switch piano, single pole, one way, 5/ 6 Amps, 1-module, complete all as specified and as directed. |
| 31 | Modular white cover plate with frame, 8-module including metal flush box, complete all as specified and as directed |
| 32 | LED street light fitting 35 Watt 230 Volt, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.Make: Phillips cat part No- Citystar 35 W or equivalent in Havells/ Bajaj/ Crompton. |
| 33 | House service bracket, made with 2.50mtr long galvanised iron pipe 25mm dia medium grade, 120° bends including mild steel clamps of mild steel flat 50x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. |
| 34 | Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-65, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, fixing in repairs, complete all as specified and as directed. |
| 35 | MCB, single pole and neutral, 32 Amps, 240 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 36 | MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 37 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 38 | Sub main wiring(in new concealed conduits to surfaces as required at site) for circuits/ submain wiring along with earth wire with two run of 1.50 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 1.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, using colour coding, drawn in and including any type of new conduit of any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws on the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed.Note: Cost of all three run of wire and one run of conduit of required size will be included in quoted rate. |
| 39 | LED luminaire for ceilings, size 600mmx600mm, 35/36 watt, 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of 1.50 Sqmm, 3-core, fixing in repairs, complete all as specified and as directed.Make: Havells cat part No-VENUSTREND2X2PLR36WLED857SWH or equivalent in Philips/ Bajaj/ Crompton. |
| 40 | LED luminaire for ceilings, size 295mmx295mm, 24 watt, 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of 1.50 Sqmm, 3-core, fixing in repairs, complete all as specified and as directed.Make: Havells cat part No-PLUTO1X1PLR24WLED840SG2 or equivalent in Philips/ Bajaj/ Crompton. |
| 41 | Labour ony for point wiring (in new concealed conduits to surfaces as required at site) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, of any decriptions, drawn in and including any type of new conduit, of any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including pressed steel/ welded mild steel terminal box 1.20mm thick coated and including old copper wire insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed.Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate. However old wire will be used as retrieved from dismantaling from serial item No- 2.01 here-in-before. |
| 42 | Amount of Schedule of credit as mentioned here-in-after shall be deducted from quoted amount. |