|
| 1 | S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as reqd. |
| 2 | 6 Module |
| 3 | 8 Module |
| 4 | 12 Module |
| 5 | 1 Module |
| 6 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
| 8 | 1x1.5 sq.mm |
| 9 | 2x2.5 sq.mm |
| 10 | 2x4 sq.mm |
| 11 | 2x6 sq.mm |
| 12 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq.mm + 2 X 6 Sq.mm earth wire |
| 13 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group B |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 15 | 5/6 amp switch |
| 16 | 3 pin 5/6 amp socket outlet |
| 17 | 15/16 amp switch |
| 18 | 6 pin 15/16 amp socket outlet |
| 19 | Bell Push |
| 20 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \"C\" curve including connections, painting etc. as required. |
| 21 | Supplying and fixing of modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 22 | S/F of suitable size G.I. box with modular plate and cover in front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc. |
| 23 | S/F of brass batten/holder including connections etc as reqd |
| 24 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 25 | Supplying and fixing of following sizes of Heavy Duty class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 26 | 25 mm |
| 27 | 20 mm |
| 28 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 29 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required |
| 30 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door |
| 31 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door |
| 32 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 33 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 100 amps |
| 34 | Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 35 | Supplying and fixing following 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 36 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 37 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 38 | Providing and fixing G.I. pipes complete G.I. fittings and clamp, i/c cutting and making good the same etc. as required at site.32 mm nominal dia Pipes |
| 39 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 40 | Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, Class of Insulation: B, 3 Nos. Blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power Factor not less than 0.9, service Value (CMM/W) minimum 6.85, Air Delivery minimum 215 CMM, 350 RPM (Tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temprature rise= 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC supply, earthing etc. complete as required. |
| 41 | Supply, Installation,testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/walI, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Fitting Supply, Installation,testing and commissioning of pre-wired, wall mounted fancy white tight, suitable for installation of LEO bulb, 220-240 V, 50 Hzcomplete i/c all accessories but without butt etc. including connection, etc. complete as required. Make Philips, Cat No. Cat No. Comet watt fancy light B22 or e |
| 42 | Supply, Installation,testing and commissioning of pre-wired, wall mounted fancy white tight, suitable for installation of LEO bulb, 220-240 V, 50 Hicomplete i/c all accessories but without butt etc. including connection, etc. complete as required. Make Philips, Cat No. Cat No. Comet watt fancy light B22 or e |
| 43 | Supply, Installation, testing and commissioning of 10 watt, LED bulkhead pressure die cast housing with lP65 protection and lK09 impact resistance suitable for surface and watt mounting applications., 220-240 V, 50 Hz complete i/c all accessories etc directly on surface including connection with 1.5 sq. mm FPLS PVC insulated, copper conductor cable and earthing etc. as required. Make Philips, Model endura LED Bulkhead, Cat No.WT202W LED10S CW PSU S3 PC or equivalent model of Thorn/Trilux |
| 44 | Supply, Installation, testing and commissioning of T2 inch heavy duty, Ac. Single Phase 230 Volt, 50 Hz, 2350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connection etc. as required |
| 45 | Supplying and fixing of 1 Module RJ-45 computer socke i/c CAT 6 on existing box/cover plate and making of connection etc. complete as required Make Wipro, North-West CAT No. R5200 or equivalent Model of Legrand/ Schneider |
| 46 | Supply, Installation,testing and commissioning of z8 watt, ceiling circular tight for domesticgrade.surge protect on upto 3 kV 8widevoltageprotection160-360 V, 50Hz completei/callaccessoriesetc.directlyonceilingincluding g connection witht.5 sp. mm FRLS PVC insulated, copperconductor cable and earthing etc. as required. Make Philips, Cat No.flute flowt8W. WW/NW/CDL or equivalentmodel of Thorn/Trilux |
| 47 | Supply, installation,testing and commissioning of 1 HP Borewell submersible pump suitable for 100 mm dia bore, having head (116-36) meter, flow rate (0-52) LPM, single phase, 230V, 50 Hz, with control panel making of cable termination etc completed as required, , Make Kirloskar, Cat.No-KP4 Jalraaj UVA 30-1016 CP or equivalent model of KS8 |
| 48 | Supplying of one number P\/C insulated and PVC sheathed / XLPE copperconductorun armouredpowercableof 650/1200 KV grade ofsize 3C x 2.S sqmm etc as required |
| 49 | Cleaningofborewelt fromall kindsofsoil/sandforalldepth,including liftup and laydown of pump set, lowering of cleaning tools, bailing ouit water, disposal of surplus, soil, providing and fixing of necessary structure for chain pully detection of water leakage, replacing of nut bolts if any etc. as required at site. |
| 50 | Supply,installation, testing andcommissioningof1 HP. direct onfine starter with sheet steel enclosuressuitable for 1-phase, 220v , complete set with contractor & OLR , start, stop push button with indicator lamps, voltmeter,ammeter,includingmountingarrangementofstarterwithaft accessoriesetc. as required.MakeHavells UREA-OOL submersiblepump controller ‹standard)- 1 Phase , Cat No. IHAOOAJ1FD or equivalent model of Crompton/ BCH Electric |
| 51 | Supplying and fixing of 9 watts pin type LED bulb in the existing holder complete as required make : Philips CAT No.22 |
| 52 | Supplying and fixing of snap-on DLP trunking of size 105 mm x 50 mm with cover and including accessories such as cover , flat angle ,end caps internal/ external angle support etc. on the wall/ surface complete all as required. |