| 1 | Excavation: Earth work in excavation not exceeding 30cm in depth but exceeding 1.5m in width as well 10sqmt on plan including getting out and disposal of excavated earth up to 50m and lift up to 1.5m, as directed by Engineer-in-charge |
| 2 | PCC:1:2:4 (1Cement:2 Coarse sand(sand-III): derived from natural source:4grade stone aggregate 20mm nominal size derived from natural sources) |
| 3 | Footing concrete: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level |
| 4 | Concrete: 1:1.5:3(1cement:1.5coarse sand (Zone-III) derived from natural source: 3grade stone aggregate 20mm nominal size derived from natural sources) |
| 5 | Reinforced cement concrete work in walls, including attached pilaster, buttresses, plinth and string course, fillets, column, pillars, piers, abutments, post and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 6 | Column up to GL concrete: 1:1.5:3(1cement:1.5coarse sand (Zone-III) derived from natural source: 3grade stone aggregate 20mm nominal size derived from natural sources) |
| 7 | Reinforced Steel up to GL: Thermo-Mechanical Treated bar of grade Fe-500D or more |
| 8 | 1:2:4 (1Cement:2 Coarse sand(sand-III):derived from natural source:4grade stone aggregate20mm nominal size derived from natural sources) |
| 9 | PCC Plinth Beam concrete:1:1.5:3(1cement:1.5coarse sand (Zone-III) derived from natural source: 3grade stone aggregate20mm nominal size derived from natural sources) |
| 10 | Reinforced Steel up to GL:Thermo-Mechanical Treated bar of grade Fe-500D or more |
| 11 | Plinth Beam concrete:1:1.5:3(1cement:1.5coarse sand (Zone-III) derived from natural source: 3grade stone aggregate20mm nominal size derived from natural sources) |
| 12 | Reinforced Steel up to GL:Thermo-Mechanical Treated bar of grade Fe-500D or more |
| 13 | Lintel Beam concrete:1:1.5:3(1cement:1.5coarse sand (Zone-III) derived from natural source: 3grade stone aggregate20mm nominal size derived from natural sources) |
| 14 | Reinforced Steel up to GL:Thermo-Mechanical Treated bar of grade Fe-500D or more |
| 15 | 9\"Brick Wall :Brick work with common burnt clay F.P.S(non-Modular) bricks of Class designation 7.5 in foundation and plinth in: |
| 16 | Cement Mortar 1:6 (1 Cement:6 Coarse sand) |
| 17 | 4 1/2\" Brick wall: Brick work 7cm thick common burnt clay F.P.S (non-modular) brick of class designation 7.5 in cement mortar (1:3) in superstructure above plinth level and up to floor five level. |
| 18 | Concrete Roofing : 1:1.5:3(1cement:1.5coarse sand (Zone-III) derived from natural source: 3grade stone aggregate20mm nominal size derived from natural sources) |
| 19 | Reinforced Steel in roof: Thermo-Mechanical Treated bar of grade Fe-500D or more |
| 20 | Plastering 12mm External wall:12mm cement plaster mix,1:6 |
| 21 | 12mm PlasteringInternal wall : 12mm cement plaster mix,1:6 |
| 22 | Painting Internal: New work(two or more coats )over and including water thinkable priming coat with cement primer having VOC content less than 50grams /liter |
| 23 | Painting Steel work: Enamel painting of metal work at all heights &levels including surface preparation, applying primer and putty on the surface and painting two coats on the surface. |
| 24 | Painting External: New work (Two or more coats applied @3.28ltr/10Sqmt)over and including priming coat of exterior primer applied @2.20Kg/10sqmt |
| 25 | PCC Floor M10:Concrete of M10 grade with minimum cement content of 220Kg/cum |
| 26 | Concrete Paver Block: Cement concrete pavement with 1:1.5:3 including Finishing. |
| 27 | Rolling Shutter: Providing & fixing Rolling shutter of required Size & standard as per the direction of Engineer-in-Charge. |
| 28 | Supplying & fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required |
| 29 | 25mm |
| 30 | Wiring for light point /fan point/exhaust fan point /call bell point with 1.5sqmm RLS PVC insulated copper conductor single core in surface /recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 31 | Supplying and fixing following switch /socket on the existing modular plate & switch box including connection but modular plate etc. as required. |
| 32 | 5/6A Switch |
| 33 | 15/16A Switch |
| 34 | Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing up to GLS/CFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 35 | Miscellaneous Itemany item not included |