| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 3 | Providing and laying stone soling by way of Nallah boulders size on level ( Hand packed ) Watering ,ramming complete below foundation & rooms including carriages of all materials. |
| 4 | Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40mm nominal size crushed stone agg.) |
| 5 | CAST-IN-SITUProviding and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level5.1.2 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Cast in situ Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with:1:3:6(1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) icl all carriage of materails. |
| 9 | Centering and shuttering including strutting, propping etc and removal of form work |
| 10 | Foundations, footings, bases of columns etc. for mass concrete. |
| 11 | Walls any thickness including attached buttresses, plinth and string courses etc. |
| 12 | Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 13 | Columns, pillars, piers, abutments, posts and struts. |
| 14 | Stairs, (excluding landings) except spiral staircases : |
| 15 | Suspended floors, roofs, landings, balconies and access plateform |
| 16 | Edges of slabs and breaks in floors and walls under 20 cm wide |
| 17 | Reinforcement for R.C.C work including straightening cutting, bending placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more..Including carriage of all materials involved with loading unloading and stacking complete. |
| 18 | Filling in with spilt nallah boulders (75mm to 150mm thick) under floor handpacked & rammed complete incld all carriages complete. |
| 19 | Brick with FPS bricks of class designation 75 in superstructure in cement mortar 1:6 (1 cement : 6 coarse sand) upto v level. |
| 20 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Imported wood |
| 21 | Providing and fixing panelling or panelling and glazing in panelled or panelledand glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 32 mm thick. Imported wood(German quality KD Wood) |
| 22 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Imported wood(German quality KD Wood) |
| 23 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mmfor doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Imported wood(German quality KD Wood) |
| 24 | Providing and fixing of 3.5 mm thick Float glass panes |
| 25 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 26 | Providing and applying white cement based wall putty of avg.1mm of approved brand and manifuture |
| 27 | Finishing walls with acrylic smooth exterior paint of required shade onNew work (Two or more coats applied @ 1.67 liter/10sqm over andincluding priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 28 | Applying priming coat: 13.58.1 With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on wood / steel works. |
| 30 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 31 | Providing and fixing stainless steel (Grade 304) railing made of Hollowtubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete ,including fixing the railingwith necessary accessories and stainless steel dash fasteners, stainless steelbolts etc. of required size, on the top of the floor or the side of waist slabwith suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 32 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Including 1mm thick MS Sheets for sofits and eves boarding incl all carriage of materials. |
| 33 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side ofthe sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required. |
| 34 | Providing ridges/ hips /valleys 600mm overall width with GS plain colour sheets with necessary fittings 50mm thick |
| 35 | Providing and fixing plained eaves boarding.@nd class Kail wood 250x32 mm (nominal size) |
| 36 | Providing and fixing of teen chajja of coloured teen sheets including cost of base work nails etc. complete job as per the direction of engineer incharge. |
| 37 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 38 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing completE |
| 39 | Providing and fixing of bright finished brass hardware fittings of approved make as per directions of EIC. |
| 40 | 125 mm Handle |
| 41 | 200 mm Handle |
| 42 | 100x10mm Tower bolt |
| 43 | 150x10mm Tower bolts |
| 44 | Stay hooks |
| 45 | L - Drop 18\" with inbuilt locking system |
| 46 | Providing and fixing of conduit pipes 20mm diameter of approved brand and manufacture complete |
| 47 | Providing and fixing of concealed junction box of approved make |
| 48 | Providing and fixing of Fan junction box of approved make |
| 49 | Carriage of different items by machanical transport including loading/unloading. |
| 50 | 40mm + 20mm nominal size aggregates for an average lead of 20 Kms |
| 51 | Sand from kakapora for an average lead of 20 Kms |
| 52 | Bricks for an avg. lead of 20kms Please Enable Macros to View BoQ information |