| 1 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)includingattachedpilasters,columns,piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: |
| 5 | 1:1.5:3(1cement : 1.5 coarse sand(zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 7 | Foundations,footings,basesof columns,etc.formass concrete |
| 8 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers with water proof ply 12 mm thick |
| 9 | Shelves (Cast in situ) |
| 10 | Weather shed, Chajjas, corbels etc., including edges |
| 11 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : |
| 12 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Providing,transporting,hoistingandfixingaboveplinthlevelupto floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 14 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 15 | Providingandfixing 18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters,window sills,facias andsimilar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 16 | Granite stone slab of colour black, Cherry/Ruby redArea of slab over 0.50 sqm |
| 17 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 18 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 19 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 20 | 125 mm |
| 21 | 100 mm |
| 22 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 23 | 200x10 mm |
| 24 | 150x10 mm |
| 25 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 26 | 300x16 mm |
| 27 | 250x16 mm |
| 28 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 29 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. |
| 30 | 40 mm |
| 31 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 32 | Electric resistance or induction butt welded tubes |
| 33 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 34 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 35 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 36 | Providing and fixing bolts including nuts and washers complete. |
| 37 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. |
| 38 | 0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 39 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 40 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 41 | Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 42 | 110 mm diameter |
| 43 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 44 | Bend 87.5°(22.1.1) 110 mm bend |
| 45 | Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 46 | 12 mm cement plaster of mix: |
| 47 | 1:4(1 cement: 4 fine sand) |
| 48 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 49 | New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 50 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture,including applying additional coats wherever required, to achieve even shade and colour. |
| 51 | Two coats |
| 52 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 53 | Old work (One or more coat applied @0.90 Itr/10 sqm). |
| 54 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 55 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
| 56 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 57 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 58 | Two or more coats on new work |
| 59 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 60 | One or more coats on old work |
| 61 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 62 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. |
| 63 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 64 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 65 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. |
| 66 | With G.I. barbed wire |
| 67 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 68 | Flexible pipe32 mm dia |
| 69 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 70 | Rectangular shape 453x357 mm |
| 71 | Providing and fixing PTMT grating of approved quality and colour. |
| 72 | Rectangular type with openable circular lid(37.1.1) 150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 73 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 74 | 20 mm nominal dia Pipes |
| 75 | 25 mm nominal dia Pipes |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 77 | 20 mm nominal dia Pipes |
| 78 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): |
| 79 | 40 mm nominal bore |
| 80 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work |
| 81 | 40 mm dia nominal bore |
| 82 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 83 | 25 to 40 mm nominal bore |
| 84 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 85 | 25 mm nominal bore |
| 86 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 87 | 30 cm length(14.1.1.)15 mm nominal bore |
| 88 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 89 | For fixed portion(45.1.1) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 90 | Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)(45.2.1) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 91 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. |
| 92 | Anodized (AC 15) aluminium |
| 93 | Providing and fixing cup boardshutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade l), of approved make, including Ilnd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. |
| 94 | With non decorative veneering on both sides |
| 95 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 96 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 97 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 98 | Upto 5 mm depth and 5 mm width |
| 99 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. |
| 100 | 205 X 19 mm |
| 101 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with“S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge. |
| 102 | Long pattern W.C Pan of size 580x440 mm |
| 103 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 104 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 105 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 106 | Kitchen sink without drain board(53.1.1) 610x510 mm bowl depth 200 mm |
| 107 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 108 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 109 | Hard drawn steel wire fabric |
| 110 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type orof approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 111 | 25 mm average thickness |
| 112 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of Engineer- In-charge complete in all respect. |
| 113 | Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make |
| 114 | Providing and laying SBR Polymer modified (of approved make @ minimum 2% by wt. of cement used) plain/reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concretehavingthespecifiedminimumcharacteristiccompressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of RCC member. Note: Rates shall be for finished surface area of concrete and shall include the cost of making holes in existing RCC slab, if required, for pouring concrete in shuttering mould of jacket and appropriate approved Super-Plasticiser for rendering concrete as flowable self compactingand SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument) |
| 115 | 50 mm thick in Grade M25 with cement content not less than 330 kg per cum |
| 116 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used)as per specifications and directions of Engineer-in-charge.Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 117 | 25 mm average thickness in 2 layers. |
| 118 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 119 | Frame size 45 x 70 mm |
| 120 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 121 | Superior Hard Wood Cat-II(A) |
| 122 | Providing and fixing panelled or panelled and glazed shutters for doors, windows andclerestory windows, fixing withbutt hinges of required size withnecessary screws,excludingpanellingwhichwillbepaid forseparately,allcompleteasperdirectionofEngineer-in-charge.(Note: Butt hinges and necessary screws shall be paid separately) |
| 123 | Superior Hard Wood Cat-II(A)(61.1.1) 30 mm thick shutters |
| 124 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 125 | Superior Hard Wood Cat-II(A) |
| 126 | Providing and fixingOHS-1709 Overhead Shower ø105mm Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System 15 or 20mm inlet. |
| 127 | Providing and fixing Angular Stop Cock with wall Flange of approved quality of make Jaquar FUS-29053 or equivalent |
| 128 | Supply of 12mm thick Marine plywood conforming to IS:710 |
| 129 | Providing and fixing bib cock of approved quality : make of Jaquar KUP-35037PMor equivalenta) 15 mm nominal bore |
| 130 | Providing and fixing Sink Cock with extended swinging make of Jaquar FLR-5347SD or equivalent of approved quality as per the direction of Engineer - in - charge. |
| 131 | Providing and applying two coats of high performance polymer modified cementitions coating(Dr.Fixit Fastflex)(@0.50-0.55 Kg /Sqm)to form film of 1.2-1.5 mm DFT as per manufacturer\"s specification,after scraping and properly cleaning the surface to remove loose particle,complete as per direction of Engineer -In-Charge. |
| 132 | Providing and fixing exposed part kit of concealed stop cock with fitting sleeve, operating lever & Adjustable wall flange with seal(Make of Jaquar COP-083KPM or equivalent) (compatible with ALD-083 or ALD-089) as per the direction of Engineer - in - charge. |
| 133 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class Acategory with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 134 | 25 mm thick |
| 135 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 136 | 250x10 mm |
| 137 | 100x10 mm |
| 138 | Providingandfixingbright finishedbrasshandleswithscrewsetc. complete: |
| 139 | 125 mm |
| 140 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 141 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 142 | Two or more coats on new work |
| 143 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 144 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 145 | W.C. pan with ISI marked white solid plastic seat and lid |
| 146 | ProvidingandfixingP.V.C.lowlevelflushingcisternwithmanually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 147 | 10 litre capacity - White |
| 148 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 149 | Of area 3 sq. metres and below |
| 150 | Providing and fixing 18mm thick both side balancing lamination factory press HDFC board of approved brand CABINET SHUTTER fixed with auto hinges and handle facility etc. all complete as per the direction of Engineer-in-charge(Note: fittings to be paid separately) |
| 151 | Providing and fixing panelled or panelled and glazed shutters for doors, windows andclerestory windows, fixing withbutt hinges of required size withnecessary screws,excludingpanellingwhichwillbepaid forseparately,allcompleteasperdirectionofEngineer-in-charge.(Note: Butt hinges and necessary screws shall be paid separately) |
| 152 | Padauk wood30 mm thick shutters |
| 153 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 154 | Padauk wood |
| 155 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 156 | Padauk wood |
| 157 | Providing and fixing pillar cock make of Jaquar DRC-37001 or equivalent. |
| 158 | 15mm dia nominal bore. |
| 159 | Providing and fixing PVC (SWR) moulded fittings / accessories for PVC pipes including jointing with solvent : PVC door bend |
| 160 | 110 mm dia |
| 161 | 75 mm dia |
| 162 | Providing and fixing PVC Nani trap as per direction of Engineer Incharge. |
| 163 | 110x75 mm dia |
| 164 | Providing and fixing UPVC (SWR) soil, waste and vent pipes (6 kg/Sqm) with solvent joint type-B |
| 165 | 110 mm dia |
| 166 | 75 mm dia |