| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting it out in soft/loose soil including forming bottom surface to required level for laying pipes/ cables all as specified. |
| 2 | Returning, filling in excavated soil including spreading, leveling, watering, well ramming in layers not exceeding 25cm all as specified. |
| 3 | Removing the surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above starting point all as directed. |
| 4 | M&L cement concrete in foundation Type B1 (20mm graded stone) 1:2:4 in foundations all as specified |
| 5 | M&L for cement concrete 40 mm grade Type B2 , 1:2:4 in foundations all as specified |
| 6 | Supply and laying in replace of light grade GI pipe 40 mm dia with all fittings/fixtures or laying in trenches all as specified and as directed. |
| 7 | Supply and laying in replace of light grade GI pipe 80 mm dia with all fittings/fixtures or laying in trenches all as specified and as directed. |
| 8 | Supply and laying in replace of light grade GI pipe 100 mm dia with all fittings/fixtures or laying in trenches all as specified and as directed. |
| 9 | Supply and laying of DWC pipe, ISI marked of outer dia 50mm and inner dia 38mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler,\"O\" Ring etc, for protection of cable complete all as specified and as directed. |
| 10 | ditto all as per item No above but outer dia 90mm inner dia 75mm |
| 11 | ditto all as per item No above but outer dia 110mm inner dia 95mm |
| 12 | M & L for disconnecting and taking down the existing burnt out UG cable of size 6 sqmm to 25 sqmm of any core along with DWC Pipe from trenches all as specified and as directed. |
| 13 | M & L for disconnecting and taking down the existing burnt out UG cable of size 35 sqmm to 95 sqmm of any core along with DWC Pipe from trenches all as specified and as directed. |
| 14 | M & L for disconnecting and taking down the existing burnt out UG cable of size 120 sqmm to 300 sqmm of any core along with DWC Pipe from trenches all as specified and as directed. |
| 15 | Supply and lay XLPE Insulated armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade of size 6 sqmm 2 core all as specified and as directed. Note : Earthwork and other connected items like DWC/GI Pipe measured and paid separately |
| 16 | - ditto all as per item No 15 above but cable size 10 sqmm x 2 core |
| 17 | - ditto all as per item No 15 above but cable size 10 sqmm x 4 core |
| 18 | - ditto all as per item No 15 above but cable size 16 sqmm x 2 core |
| 19 | - ditto all as per item No 15 above but cable size 16 sqmm x 4 core |
| 20 | - ditto all as per item No 15 above but cable size 25 sqmm x 4 core |
| 21 | - ditto all as per item No 15 above but cable size 35 sqmm x 3.5 core |
| 22 | - ditto all as per item No 15 above but cable size 50 sqmm x 3.5 core |
| 23 | - ditto all as per item No 15 above but cable size 70 sqmm x 3.5 core |
| 24 | - ditto all as per item No 15 above but cable size 95 sqmm x 3.5 core |
| 25 | - ditto all as per item No 15 above but cable size 120 sqmm x 3.5 core |
| 26 | - ditto all as per item No 15 above but cable size 150 sqmm x 3.5 core |
| 27 | - ditto all as per item No 15 above but cable size 185 sqmm x 3.5 core |
| 28 | - ditto all as per item No 15 above but cable size 240 sqmm x 3.5 core |
| 29 | - ditto all as per item No 15 above but cable size 300 sqmm x 3.5 core |
| 30 | Supply and fixing aluminum lugs 10 sqmm to 25 sqmm. |
| 31 | Supply and fixing of lugs aluminum of sizes 35 sqmm to 70 sqmm. |
| 32 | Supply and fixing of lugs aluminum of sizes 95 sqmm to 150 sqmm. |
| 33 | Supply and fixing of lugs aluminum of sizes 240 sqmm to 300 sqmm. |
| 34 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core /4 core XLPE, Armoured.Al conductor cable of size 25 to 50 sqmm, indoor/out type |
| 35 | ditto all as per item No 34 above but cable size 70 to 120 sqmm |
| 36 | -ditto all as per item No 34 above but cable size 150 to 185 sqmm |
| 37 | -ditto all as per item No 34 above but cable size 240 to 300 sqmm |
| 38 | Supply and fix cable jointing kit for 1.1 KV grade cable for end termination joint complete with jointing material heat shrink type and accessories suitable for 3.5 core /4 core XLPE, Armoured.Al conductor cable of size 25 to 50 sqmm, indoor/out type |
| 39 | ditto all as per item No 38 above but cable size 70 to 120 sqmm |
| 40 | -ditto all as per item No 38 above but cable size 150 to 185 sqmm |
| 41 | -ditto all as per item No 38 above but cable size 240 to 300 sqmm |
| 42 | M& L for Painting of street light poles, by removing of old paint & applying one coat of red oxide metal primerand two coats of approved aluminium paint to steel tubular swaged pole, cross arm and service bracket complete all as specie and directed |
| 43 | M& L for Painting of RCCpole by Cement wash with Portland cement slurry to a smooth bodied opaque finish all as specified and as directed. |
| 44 | M & L for dismantling steel poles/ struts,any size, supply and errecting Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) .Note :- Necessary earth work and PCC foundation, coping measured and paid separately. |
| 45 | M & L for dismantling concrete poles/ struts, any size, supply and errecting Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l2mm x 279mm at bottom, class 10all as specified and as directed.Note : Necessary earth work and PCC foundation, coping measured and paid separately. |
| 46 | M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down with all fitting and as directed. |
| 47 | M&L for Galvanized iron strip 32 x 6mm buried in ground or fitted with wall/Pole including taking down with all fitting and as directed. |
| 48 | Supply and fixing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire |
| 49 | Dismantling and taking down any wattage or size of street light/flood light/post top lantern fittings for repair or replacement all as specified and directed. |
| 50 | S & F in repairs LED bollard light fitting 10W IP 66 sustainble performance all as specified. |
| 51 | Supply and fixing LED street light fitting 35/45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management inmultiple optics complete withIP 65/66 protection complete. |
| 52 | -ditto- all as per item No 51 above but 70 Watt |
| 53 | -ditto- all as per item No 51 above but 120 Watt |
| 54 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp |
| 55 | -ditto- all as per item No 54 above but 100 Watt |
| 56 | -ditto- all as per item No 54 above but 120 Watt |
| 57 | Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 58 | -ditto- all as per item No 57 above but 40 Watt |
| 59 | Supply and fixing all in one series solar street light 24W High efficiency mono crystaline solar PV modules. lituium ferro phosphate battery with in built BMS technology, High efficeincy LED, MPPT solar charge controller and aluminium extruded body, authomatically control the dimming and brigtness of light all as specified and directed. |
| 60 | Supply and Fixing of Street Light fitting GI bracket suitable for fixing of street light fitting by fabricating the size of25/32 mm dia Light grade GI pipe of length 1.2 mtr and suitable bend,complete all as specified and directed including taking down. |
| 61 | Supply and fix LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangenment, off white colour of size 140 x 140 x 95 mm (internal daimention) comprising 02 Nos Al busbar of adequate capacity including suitable size MS clamps, all as directed. |
| 62 | -ditto all as per item No 61 above but SMC box size 240x130x95 |
| 63 | Supply,fixing,connecting and testing on load change over switch, 4 pole, 415 volts, AC with SS enclosure, side handle operated including necessary electrical connection of 125 Amps capacity complete all as specified. |
| 64 | Disconnecting and taking down the existing oldunserviceable MCCB/ MCB for existing Feeder piller box. |
| 65 | S & F MCCB 3 pole 415 Volts fixed type 25 to 100 Amps with breaking capacity 16 KA all as specified and directed |
| 66 | S & F MCCB 4 pole 415 Volts 16 KA 16 A to 63 Amps all as specified and directed. |
| 67 | S & F MCCB 4 pole 415 Volts 16 KA 100Amps all as specified and directed. |
| 68 | S & F MCCB 4 pole 415 Volts 16 KA 125Amps all as specified and directed |
| 69 | S&F MCCB 4 pole 415V adjustable type 160 Amps with breaking capacity 36 KA |
| 70 | S&F MCCB 4 pole 415V adjustable type 200 Amps with breaking capacity 36 KA |
| 71 | S&F MCCB 4 pole 415V adjustable type 250 Amps with breaking capacity 36 KA |
| 72 | S & F 415V 10 KA MCB TP 25 to 63 Amps capacity |
| 73 | S & F 415V 10 KA MCB TPN/FP 16 to 32 Amps capacity |
| 74 | S & F 415V 10 KA MCB TPN/FP 40 to 100 Amps capacity |
| 75 | M&L for wiring with 1100 volt grade, 2 runs of 1.5 sqmm single core FRLSH PVC insulated unsheathed multi stranded copper conductor cable drawn through rigid PVC conduit from street light in box/looping box to street light fitting along with 1.5 sqmm single core FRLSH PVC multi stranded copper conductor cable green in colour as contineous earth wire complet all as specified and as directed . |
| 76 | S & F rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of 25mm dia |
| 77 | M&L for earthing complete with galvanised steel earth plate electrod 60cmx60cmx60mm thick buried directly in ground ( each pit not less than 2.25 mtr below ground level) with Top edge of earth plate not less than 1.5 mtrbelow normal ground level, including provision of gakvnised earth strip 32x6 mm connected by means of bolts, nuts, check nuts and washers of galvanised iron steel, provision of 40mm dia GI pipes medium grade for earth wire protection connected from earth plate electrode to main switch board, provision of 15 mm dia GI pipe perforated medium medium grade for glatering arrangement and PCC 1:3:6 type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 for earth pit. Cover with 6 No\"s 8 mm dia high strength deformed steel TMT bars on both ways, including test terminal block made of gun metal or phosphorous bronze 75x75x25 mm and drilled and screwed including 3 nos 8 mm dia, 25 mm long at hex head screw also necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n. exc. 50 mtr, provision of char coal and salt complete all as shown in electrical plate No 3 of scedule Part-1 of 2009 all as specified, directed and Testing on completion. |
| 78 | M&L for painting of LT Panel of any type ( indoor / outdoor) by removing of old paint & applying one coat of red oxide metal primerand two coats of approved eanmel paint to LT Panel complete all as specied and directed |
| 79 | Servicingof solar power generating PV modules for security lighting system, mounted on poles of approx height 5.0mtr by cleaning the photo voltaic panel using soft cloth and cleaning agent, adjusting to the proper direction and preperation of old paited surfaces of Galvanized iron pole painting with two coats of aluminium paint on poles and on all iron surfaces/steel surfaces,complete all as cpecified..Note- replacing the defective parts/components required will be measured and paid seperately .under relevant items as \"supply only\", |
| 80 | S & F in repair tubular lead battery 12V,100 AH, Make: EXIDE orequivalent in TATA/Luminous/ |