| 1 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting outin soft/loose soil,.all as specified and directed by Engineer-in-charge. |
| 2 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc., or for shafts, wells, cesspits, manholes etc., not exceeding 10 Sqm on plan and n. exc. 1.5 metre in depth and getting out, hard/dense soil, complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Excavation in over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and as directed by Engineer-in-Charge. |
| 4 | M&L for rolling and consolidation of formation of surfaces in cutting with power roller of 8 to 12 tonne capacity power roller including filling up depression which occur during rolling complete all as specified and as directed by Engineer-in-Charge. |
| 5 | M&L fo soling (or sub base) with broken bouldersor quarried stone interstices filled of size 100mm to 50mm, surfaces formed and rolled and consolidated to required gradient and camber spread thickness 200 mm in single layer complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Removing excavated materialto distance exc. 250 mtr but n exc 500 mtr and depositing where directed all as specified and directed by Engineer-in-charge. |
| 7 | M&L hardcore of broken stone or boulders gauge exc 63 mm but n exc. 100 mm , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface.complete all as specified and as directed by Engr-In-Charge. |
| 8 | M&L for 100mm thick plain cement concrete 1:4:8, type D-2, using 40mm graded crushed stone aggregate, as in sub base, complete all as specified and asdirected by Engineer-in-Charge. |
| 9 | M&L for 40mm thick sand as in cushioning under interlocking paver blocks flooring including watering and consolidation, complete all as specified and directed. |
| 10 | M&L for machine pressed precast coloured concrete interlocking paver blocks of any shape and size, confirming of IS-15658 : 2006 of 80mm thick M-40 Grade, laid and jointed with grey cement and pigment, complete all as specified and directed. |
| 11 | M&L providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.all as specified and directed by Engineer-in-charge. |
| 12 | M&L for two coats of cement base paint including preprationof surfaces plastered or unplastered as in concrete surfaces all as specified and directed by Engineer in charge. |
| 13 | M&L for cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in bed to 300mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 14 | M&L for 300mm bore reinforced concrete pipes, Class NP2, laid in trenches and jointed in CM 1:1 complete with collars and tested after they are laid, complete all as specified and directed. |
| 15 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 Mtr mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 16 | M&L rendering 15mm thick on brick wall or concrete surface consisting two layers, under layer of 10mm thick in CM (1:6) & top layer of 5mm thick in cement mortar 1:4 mixed with water proofing compound @ 3% by weight of cement, finished even and smooth without using extra cement complete all as specified and directed. (Note:-Water proofing compound shall be measured and paid saperately.) all as specified and directed by Engineer-in-charge. |
| 17 | M&L for preparing new plaster surfaces of walls applying one coat of weather coat primer and two coats of weather proof acrylic emultion paint all as per manufacturers instructions and directed including steel scaffolding complete all as specified by GE/Engineer-in-Charge Make: Asian Paint Apex, Berger weather coat or equivalent upto bldg height 15m all as specified and directed by Engineer-in-charge. |
| 18 | Supply of integral water proofing compound, complete all as specified and as directed by Engr-In-Charge. |
| 19 | M&L for cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in kerbs or mud stops, copings and the like including weathering, slightly rounded or chamfered angles/ edges and throating including necessary formwork, complete all as specified and directed. |
| 20 | M&L TMT Mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 21 | All as per ser item No 20.00 here-in-above but 6mm dia and over upto and including 10mm dia but as in stirrups, spaces and binders. |
| 22 | M&L providing precast cement concrete louvres and jallies, 35mm thick (mea sured solid), in cluding all mould-ings but excluding frame Set in cement mortar 1:4 type B0 1:2:4(12.5mm graded Aggregate all as specified and directed by Engineer-in-charge. |
| 23 | M&L Framed work in structural steel as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. |
| 24 | M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete,,all as specified and directed by Engineer-in-charge. |
| 25 | M&Lfor Mild steel screw bolts (Machine made) with hexagonal or square heads at one Kg end and screws the other or screwed both ends, each screwed and to be fitted with 11 washers and one hexagonal or square nut length at bolt exceeding 5 cm but not exceeding 10 cm long for 11 to 15mm dia of neck complete. all as specified and directed by Engineer-in-charge. |
| 26 | M&L for6mm thick polycarbonate double layered sheets of approved shades fixed over roof trusses, wall,gates, etc fixed with self tapped screw as per 12 manufacturer\"s instruction by extra clamping, complete all as specified and as directed by Engr-in-Charge. |
| 27 | Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed. |
| 28 | Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed. |
| 29 | Supply spreading in trenchesdry crushed Stone sand for cable protection and punning down gently by hand all as specified. |
| 30 | Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed. |
| 31 | Supply and fix galvanized iron steeltubing light grade of 50 mm bore with all fittings as required at site andlaid in floors/trenches as incable protectionall as directed by Engr-in-Charge. |
| 32 | Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 10 sq mm 2 Core complete all as specified and directed. |
| 33 | Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 10 sq mm 4 Core complete all as specified and directed. |
| 34 | Supply and fix in repairs LED street light fittings 90/100 Watts 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, almp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed. |
| 35 | S&F copper cable flexiblePVC insulated 3 x 2.5 sqmm single core along with earth wire in PVC conduit from FRP box to street light fitting ,including aluminium flat clamp 25 X 4 mm -03 Nos with suitable nuts,bolts and washers etc all as specified and directed by Engr-in-Charge |
| 36 | Supply and fix galvanaised octgonal pole 9 meter long with top 70x70mm and bottom 155x155mm having overall thickness 3mm and base palte size 250mmx250 mmx16mm with foundation nut bolt size M24x750mm with PCD 250mm including necessary PCC/RCCfoundation for pole od size 750mm x750mmx500mm including GI Bracket made out of 40 mm dia medium grade GI tube up to 1.5 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clamp of size 40x5 mm with necessary nut bolts & washers and applying two coats of synthetic enameled paint over one coat of zinc oxide primer for clamp all as specified and directed by Engineer In charge |
| 37 | Supply and fix street light timer outdoor type panel made up of 3mm thick CRAC Sheet double door of height not exceeding 0.75meter from ground level with copper bus bar of RYB and neutral and copper wiring of suitable size and consisting of followinga) Copper bus bar of suitable size for RYB and N of suitable current rating – 1 Set b) MCCB 4 Pole 100 Amps 16KA – 01 No c) ML3 contactor 40 Amps -02 NOs d) Street time – 2 Nos e) Ammeter with CTs- 2Nos f) Voltmeter – 2 Nos g) Wiring of suitable size – 01 Job |