|
| 1 | BUILDINGS & STRUCTURE (Sch \"A\" PART-I) |
| 2 | Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price of₹ 2,93,92,445.00 inserted by the MES in Schedule ‘A’ Part-I. |
| 3 | SITE CLEARANCE AND SITE DEVELOPMENT INCLUDING EARTHWORK AND EXCAVATION (Sch \"A\" PART-II) |
| 4 | Lump sum price worked out by the Contractor for “SITE CLEARANCE AND SITE DEVELOPMENT INCLUDING EARTHWORK AND EXCAVATION”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 1,28,602.20 inserted by the MES in Schedule ‘A’ Part-II. |
| 5 | INTERNAL WATER SUPPLY (Sch \"A\" PART-III) |
| 6 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 1,81,535.02inserted by the MES in Schedule ‘A’ Part-III. |
| 7 | INTERNAL ELECTRIFICATION (Sch \"A\" PART-IV) |
| 8 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 8,99,620.27inserted by the MES in Schedule ‘A’ Part-IV. |
| 9 | TV SOCKET (Sch \"A\" PART-V) |
| 10 | Lump sum price worked out by the Contractor for “(TV SOCKET)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 13,698.00 inserted by the MES in Schedule ‘A’ Part-V. |
| 11 | FIRE FIGHTING (Sch \"A\" Part-VI) |
| 12 | Lump sum price worked out by the Contractor for “(FIRE FIGHTING)”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 3,38,640.00 inserted by the MES in Schedule ‘A’ Part-VI. |
| 13 | ROAD, PATH & CULVERT (Sch \"A\" Part-VII) |
| 14 | Lump sum price worked out by the Contractor for “(ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 3,68,657.43 inserted by the MES in Schedule ‘A’ Part-VII. |
| 15 | EXTERNAL WATER SUPPLY (Sch \"A\" Part-VIII) |
| 16 | Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 85,418.16 inserted by the MES in Schedule ‘A’ Part-VIII. |
| 17 | EXTERNAL ELECTRIC SUPPLY(Sch \"A\" PART-IX) |
| 18 | Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIC SUPPLY )”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 1,55,640.99 inserted by the MES in Schedule ‘A’ Part-IX. |
| 19 | SEWAGE DISPOSAL(Sch \"A\" Part-X) |
| 20 | Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL )”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 41,401.68 inserted by the MES in Schedule ‘A’ Part-X. |
| 21 | AREA DRAINAGE (Sch \"A\" Part-XI) |
| 22 | Lump sum price worked out by the Contractor for “(AREA DRAINAGE )”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price of ₹ 1,76,821.89inserted by the MES in Schedule ‘A’ Part-XI. |
| 23 | MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch \"A\" Part-XII) |
| 24 | SITE CLEARANCE AND SITE DEVELOPMENTBringing approved earth (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any, transportation, taxes if any etc. complete all as specified and directed.NOTE :-(a) Earth required for the item shall be supplied by contractor from outside of MOD land of any lead, at his own arrangement.(b) All cost of procurement of earth including cost of transportation, compaction royalties, tax etc shall be deemend to be included in the unit rate quoted by the contractor.(c) Forming embankments / filling in low lying areas including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming / rolling and finishing of required size, shape etc not exceeding 1.5 m high from base / natural ground level.(d) With reference to Clause 3.6 of MES Schedule Part-II on Serial Page NO. 21, it is clarified that measurement of the above item shall be of finished embankment / traverse of filled earth after consolidation / compaction and 5% deduction shall be made from measured and calculatedvolume to allow for increase in bulk.(e) Total quantitiy / partial quantity of earth may not be available in Missamari Area. The contractor shall bring the earth outside area and it is advised to quote the rate considering available of soil and its lead involved. |
| 25 | INTERNAL WATER SUPPLYS & Fof Gun-metal, globe or gate valves 80 mm bore with iron wheel head screwed both ends for iron pipe and fixed complete in all respect as specified and directed |
| 26 | S/F 15mm bore 2way Bib taps with wall flange, cast copper alloy with crutch or butterfly handle, screwed down,screwed for iron pipe or for brass ferrule complete in all respect as specified and directed. |
| 27 | INTERNALELECTRIFICATIONS&F Metal flush box 8 moudle complete in all respect as specified and as directed. |
| 28 | Fabrication, supply & fixing of GI pipe bracket up to 32 mm dia 0.9 m long & 2 set of clamps made out of 30 x 5 mm MS flat & fixed with anchor bolt suitable for 1 x 35 LED security fitting complete in all respect as specified and directed. |
| 29 | S&F 4 way VTPN DB for higher incoming current distribution upto 250 A, IP 43 with metal double door, incomer-TP/FP compact NSX or Easy Pact CVS MCCB up to 250A, outgoing-SP MCBs/TP MCBs, 65% more incomer wiring space, new compact fishbone with better thermal performance, short circuit withstand - 17 kA for 250 mS protection at Incomer with new shrouds, type tested as per IEC 61439-3 in NABL accredited lab, knockout size for incomer increased to 50 mm (to accomodate aluminium cable), without MCBs & MCCB complete in all respect as specified and directed. |
| 30 | S&F MCCB, 4 Pole, 415 V, fixed type, 40 Amps with breaking capacity 25kA complete in all respect as specified and directed. |
| 31 | TV SOCKETS&F TV socket 1 module complete in all respect as specified and directed. |
| 32 | S&F Tele socket 1 module complete in all respect as specified and directed. |
| 33 | S&F inner and outer modular cover plate of 1/2 module complete in all respect as specified and directed. |
| 34 | FIRE FIGHTINGS&F CO2 type (light weight squeeze grip type) 4.5 Kg Fire Extinguisher of BIS standard with mounting arrangement complete in all respect as specified and directed. |
| 35 | S&F Dry Chemical Powder,ABC type 6 Kgcapacity Fire extinguisher complete with initial charge and wall bracket BIS and BSEN standard with mounting arrangement on wall complete in all respect as specified and directed. |
| 36 | Supply, install, testing and commissioning of Air release valve, cast iron, double air outlet, flanged ends, confirming to IS-14845, 50 mm bore connected to the main line including all jointing materials as required complete in all respect as specified and directed. |
| 37 | EXTERNAL WATER SUPPLYS&F Pumping sets, monoblock electric driven single phase KDS-225++, 2 HP, Single Phase, 230 Volts, Size 50 mm X 50 mm Install complete incl ofPCC foundation, DOL starter and cable connection from the existing panel (1W + 1S) as on site complete in all respect as specified and directed. |
| 38 | EXTERNAL ELECTRIC SUPPLYM&L for Boring/Drilling (Horizontally) manually/mechanically under existing road(Maximum 10 M in width) suitable for passing GI tubingof 40 to 100 mm bore complete in all respect as specified and as directed. |
| 39 | S&F 1100 volts grade PVC insulated weather proof sheated aluminium cable 1.5 Sqmm 2 core with 1.5 Sqmm single core for earthing including PVC conduit medium grade not less than 20 mm dia fixed with RCC/steel tubular pole clamp or by any other means complete in all respect as specified and directed. |
| 40 | S&FErecting Steel Tubular Swaged Pole Type 410-SP-31 (8.5 mtrs long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous paint from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Paint over a coat of Primer (Externally from Top of Coping), including necessary earth work, excavation, PCC 1:3:6 using 40mm graded stone aggregate for foundation and coping with PCC 1:2:4 using 20mm stone aggregate and smooth finish complete in all respect as specified and directed. |
| 41 | S&Fjunction boxes with new ThermoplasticCable Junction Boxes IP 66/67 \"weather proof\", for outdoor installation with knockouts for cable entry with terminals suitable for 10-16 sqmm cable of Size 155 x 210 x 92 mm incl busbar fixed in repairs and including Necessary civil works and connecting all incoming and outgoing wires with AL lugs of appropiate sizes complete in all respect as specified and directed by Engr-in-Charge. |
| 42 | Supply, install, testing & commissioning of LTbusbar chamber of size (0.9 x 0.60 x 0.60 m) CPRI approved, outdoor type, factory made fabricated to CRCA sheet of 3.15 mm thickness, angle iron of size 40 x 40 x 6 mm thick of length 0.6 m from PCC, frame work and tee section (frame) of suitable sizedouble door front/rear opening and locking arrangement, floor mounted on platform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bolt, nuts and washer and makingcomplete including PCC foundationcomprising of followingaccessories:- BUS-BAR & INTERNAL CONNECTIONS:The bus-bars shall be made up of 04 Nos Aluminium 400 A rated not less than 40 mm x 10 mm, duly insulated with 1100 V grade standard colour coded PVC sleeves PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.INSTRUMENTATION SYSTEM :(a)Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(b)3 Ph Digital Ammeter CI 1.0- 01 No (c)3 Ph Digital Voltmeter CI 1.0 - 01 No (d)Phase selector (Vertical) with rotary switches(e) Danger notice plate of size 20 x 15 cm of 1.6 mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. (f) MCCB 63 Amps 4 pole - 02 Nos all complete.(g) MCB 32 Amp 4 Pole - 01 No.NOTE : (1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. (2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 43 | SEWAGE DISPOSALSupply, laying, jointing and testing of 150 mm internal diameter of Double Wall Corrugated (DWC), High Density Polyethylene Pipe (HDPE) and stiffness classes -8 (SN-8) with ISI marked (with CML no) and including all fitting of pipe & jointing material for sewage line and laid in trenches all as specified in IS -16098-2013 part-2 complete complete in all respect as specified and directed.Note : Pipe line should be connected from man hole to man hole including cutting and making good finish of existing man hole. |
| 44 | Sub total |