| 1 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations etc or manholes, cesspits, pipes and cables etc. not exc 10 Sqm on plan and getting out in any type of soil all as specified and directed by Engineer - in - Charge. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out in any kind of soil the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth, in layers not exceeding 25cm, watering, and removing surplus spoil to a distance not exceeding 50m and making good surface all as specified and directed by Engineer - in - Charge. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layersof soft / loose soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge. |
| 5 | Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engineer - in - Charge. |
| 6 | M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete and sub base all as specified and directed by Engineer - in - Charge |
| 7 | M&L Brick work with sub class \"B\" old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . |
| 8 | M & L RCC 1 : 1½ : 3, (nominal mix), Type A–1 using 20mm graded stone aggregate as in foundation including raft, footings, foundation beams and the like complete all as specified and directed by Engineer - in - Charge. |
| 9 | M & L RCC 1:1½:3, (nominal mix), type A-1, using 20mm graded aggregates as in columns, pillars, piers, posts and struts all as specified and directed by Engineer - in - Charge. |
| 10 | M & L RCC 1:1½ :3, (nominal mix), Type A-1, using 20mm graded aggregates as in beams, cantilevers, bressummers,, lintels over 1.5mtr clear span etc all as specified and directed by Engineer - in - Charge. |
| 11 | M & L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge. |
| 12 | M & L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete all as specified and directed by Engineer - in - Charge. |
| 13 | Form work to sides and soffits of floor or roof beams, lintels cantilevers, shelves including supports, over hangs and the like for rough finished surfaces complete all as specified and directed by Engineer – in – Charge. |
| 14 | M & L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge. |
| 15 | M & L 25 mm thick Cement Conrete 1:2:4 type B–0 using 12.5mm graded stone aggregates flooring finished even and rough to receive topping layer all as specified and directed by Engineer - in – Charge . |
| 16 | M & L machine cut Kota stone slab flooring 20-25mm thick over and including cement screed base 20mm thick in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer - in – Charge. |
| 17 | All as per Srl item No. 16 here in before but for vertical surfaces over screed 10mm thick in cement mortar 1:3 all as specified and directed by Engineer - in - Charge. |
| 18 | M & L granite work (of any type) 20mm thick machine cut as in steps, jambs, pillars, window cills, cooking platform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, rubbing and polishing laid over and including bedding layer or screed 20mm thick in cement mortar 1:6 all as specified and directed by Engineer - in - Charge. |
| 19 | M & L 18mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) and like in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including rendering 10mm thick cement mortar 1:3 all as specified and directed by Engineer - in - Charge . |
| 20 | Extra over Granite or marble slabs as in rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as directed. all as specified and directed by Engineer - in - Charge. |
| 21 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 22 | M & L for 75mm thick cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate as in plinth protection etc finished even and smooth without using extra cement all as specified and directed by Engineer - in - Charge. |
| 23 | M & L mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed by Engineer - in - Charge . |
| 24 | All as per Srl item No. 23here in before but 5mm and overfor as in stirrups, spacers and binders all as specified and directed by Engineer - in - Charge. |
| 25 | S & F MS steel work in tubular trusses and tubular posts and purlin including special shaped washersetc. complete using but welded tubes confirming to IS 1161- 1979 graded St 240 withone shop coat of zinc chromate primer paint complete all as specified and directed. |
| 26 | S & F 5mm thick Fe-410-W(GdeE-250) quality B Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified & directed. |
| 27 | S & F MS screw bolts 5 to 10mm dia (machine made) with hexagonal or square head at one end, screwed end to be fitted with washer and one hexagonal / square nuts all as specified and directed by Engineer - in - Charge. |
| 28 | S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. all as specified and directed by Engineer - in - Charge. |
| 29 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engineer - in - Charge. |
| 30 | S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engineer - in - Charge. |
| 31 | S & F bib taps 15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified and directed by Engineer - in - Charge . |
| 32 | S & F vitreous china wash basin, white, flat back, size 580x450mm with pillar tap cast copper alloy with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts, waste fitting brass chromium plated, plug 32mm, PVC connection and PVC waste pipe and fixing with new brackets including cutting and pinning in ends of brackets complete all as specified and directed by Engineer - in – Charge . |
| 33 | S & F stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen with plug, washers, waste fittings, waste pipe, cast iron cantilever brackets, over all size 915mm x 460mm with bowl size 410mm x 330mm x 160mm with waste pipe PVC 40mm dia all as specified and directed by Engineer-in-Charge. |
| 34 | S & F 15mm bore medium grade steel tubes galvanised with all fittings laid in trenches all as specified and directed by Engineer - in – Charge . |
| 35 | M & L rendering 15mm thick on fair facesof brick work or concrete surfacesin CM 1:4 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge .Note:- The rates do not include for the supply of integral water proofing compound, which shall be paid for in addition at “supplied only rates separately, as applicable. |
| 36 | Supply only water proofing compound complete all as specified and directed by Engineer - in - Charge . |
| 37 | M & L rendering 10mm thick on fair facesof brick work or concrete surfacesin CM 1:6 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge . |
| 38 | M & L applying two coat of cement base paint on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in – Charge |
| 39 | M & L two coats of distemper oil emulsion over a coat of primer and wall putty (Asian / JK / Birla), preparatory to distempering, on newlyplastered surfaces of walls including preparation of surfaces all as specified and directed by Engineer - in - Charge. |
| 40 | S & F anodized aluminium snap grid frame work for false ceiling size of grid 605 x 605mm all as specified and directed by Engineer - in - Charge. |
| 41 | S & F Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab/ trusses by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia.40mm long complete for size of grid 605 x605mm complete all as specified and directed by Engineer-in-Charge. |
| 42 | M & L Gypsum Board 12mm thick for insulation and acoustic purpose 60 x 60cm size fixed with screw to aluminium frame work or staples on snap grid in ceiling complete all as specified and directed by Engineer - in - Charge. |
| 43 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.all as specified and directed by Engineer - in - Charge. |
| 44 | M & L cement concrete (1:2:4)type B-1 using 20mm graded stone aggregate as in lintels up to 1.5 m clear span, seismic and other similar bands, benching, coping, bed blocks, apex stones and kerbs etc including use of necessary form work all as specified and directed by Engineer - in - Charge . |
| 45 | S&F Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both sideprelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of both sideprelaminated PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, Stile and rails feathered at edges, supplying andfixing in the frame at site as per specification complete all as specified and as directed by Engineer-in-Charge. |
| 46 | S&F Factory made wire gauzed PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single sideprelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes.Thewire gaugeshall be stretched to tighten firmly with suitable PVC sheet beading, and jointed together with solvent cement, supplying andfixing in the frame at site as per specification complete all as specified and as directed by Engineer-in-Charge. |
| 47 | S & F Solid PVC door frame factory made of size 50mmx 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tubejointed , supplying and fixing in opening complete all as specified and as directed by Engineer-in-Charge. |
| 48 | S & F framed work such as grills, grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work for water tanks and similar work conforming to Fe-290 Gde E-165 all as specified and directed by Engineer - in - Charge. |
| 49 | S&F door closer hydraulically regulated, aluminium (extruded section) body, designation No. 1, universal type suitable for door shutter upto 700mm in width and of weight not more than 35 kg and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 50 | S & F MS butt hinges, medium weight cold rolled 100mm size all as specified and directed by Engineer - in - Charge . |
| 51 | S & F aluminium alloy anodized sliding door bolt with hasp and staple (bolt type) and fixing clips of sheets cast or extruded section and fixing bolts of extruded section or cast aluminium alloy 250mm size all as specified and directed by Engineer - in – Charge . |
| 52 | S & F floor door stopper 140mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor all as specified and directed by Engineer - in - Charge. |
| 53 | S & F Aluminium anodised barrel tower bolt of extruded section 150mm long all as specified and directed by Engineer - in - Charge . |
| 54 | M & L providing two coats of synthetic enamel paint over a coat ofpink primer on new wooden surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge . |
| 55 | M & L providing two coats of synthetic enamel paintand a coat of red oxide primer onnewsteel surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge . |
| 56 | S&F for galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples. |
| 57 | S & F aluminium handle cast type anodised, 150mm long all as specified and directed by Engineer - in - Charge. |
| 58 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. Complete all as specified |
| 59 | S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm diameter of outlet all as specified and directed by Engineer - in - Charge |
| 60 | S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 61 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in loose / soft soil all as specified and directed by Engineer - in – Charge. |
| 62 | M&L for Hardcore of gauge n exc. 63 mm of broken stone, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed by Engineer - in - Charge. |
| 63 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), includingmaking drainage opening wherever required complete. |
| 64 | M & L preparation of new or previously untreated surfacesof any description over 10 cm width or girth applying two coats of synthetic enamel paintover a coat of primer onbricks, stone, concrete, asbestos cementplaster surfaces all as specified and directed by Engineer - in - Charge .Note: Pattern/ colour of painting shall be approved by Engineer-in-Charge. |
| 65 | S&F 18 to 20 mm thick HDHMR prelaminated board (one side and inner side balancing white) having minimum density of 32 kg/cum as in work station/ cabinet work/ shelves/ side hung/ top hung shutter including fixing all necessary hardware and tapping on edges, fabricated and fixed complete all as specified and directed. |
| 66 | M&L for stainless steel magnetic hinges 70 to 80 mm long L type suitable for modular kitchen cabinet shutter complete all as specified and directed. |
| 67 | M&L for stainless steel sliding channel suitable for modular kitchen cabinet drawer/ racks upto 800mm long complete all as specified and directed. |
| 68 | M&L fancy type stainless steel handle any type 75mm size complete all as specified and directed. |
| 69 | S & F bright finished brass 75 mm mortice lock with two levers vertical typewith necessary screws etc complete all as specified and directed by Engineer - in - Charge. |
| 70 | Reinforced concrete pipes 150mm bore class NP- 2, laid and jointed complete with collars, all as specified and directed by Engineer - in - Charge. |
| 71 | M&L Cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in bed to drain pipe including packing under and haunching against the sides of pipes 150mm dia (internal) after these are laid in trenches all as specified and directed by Engineer - in - Charge. |
| 72 | Factory made SFRC Pre-cast RCC manholes covers EHD-35 of size 1200mm X 600mm X 100 mm thick, conforming to IS-12592 duly fixed on manhole /gully trap opening complete all as specified. |
| 73 | M&L Cement concrete 1:2:4 type B–1 using 20mm graded crushed stone aggregate as in surface channels and drains etc including use of necessary form work all as specified and directed by Engineer - in - Charge. |
| 74 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benches for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm internal dia for pipe all as specified and directed by Engineer - in - Charge. |
| 75 | S & F DI/ GI pipe fittings such as bends, tapers, tee pieces single branch, \"Y\" junction, collars, caps and plugs etc spigot socketed or flanged ends type of size up to 100mm nominal bore conforming to IS-9520/2000 with pressure rating PN-1 (all the fittings shall be coated for rust prevention i.e. external coating zinc rich paint with finishing layer of bituminous as per Annexure - A of IS:9523/2000 and internal lining shall be of cement mortar with seal coat as per Annexure \"B\" of IS-9523/2000) complete all as specified and directed by Engineer - in - Charge. |
| 76 | S & F40mm bore medium grade steel tubes galvanized with all fittings laid in trenches all as specified and directed by Engineer - in - Charge . |
| 77 | S & F25mm bore medium grade steel tubes galvanized with all fittings laid in trenches all as specified and directed by Engineer - in - Charge . |
| 78 | S & F gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 40mm bore complete all as specified and directed by Engineer – in – Charge. |
| 79 | S & F gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 25mm bore complete all as specified and directed by Engineer – in – Charge. |
| 80 | M&L for cutting of DI pipe 100mm dia long reducing to required length for insertion of new tee for making branch connection of size 40mm dia GI and refixing the same.(i) Excavation and earthwork branch connetion will be measured and paid seperately(ii) Gasket/ rubber tyton joint required making branch connection deemed to be included in the quoted rates.(iii) DI/ GI fittings for making branch connection will be measured and paid seperately. |
| 81 | M&L Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate for foundations, mass and for repairing to paths/ road & hardstanding etc. including necessary cutting of roads/ paths for passing of pipes and making good the disturbed portion complete all as specified and directed by Engineer – in - Charge. |
| 82 | Construction of brick masonry valve pit/ chamber inside dimensions 100cm x 100cm x 90cm deep from the top of surface including cover of MS sheet 3.15mm thick and angle iron 50mm x 50mm x 6mm with hinges and locking arrangement including painting with two coats of synthetic enamelled paint over a coat of red oxide and grouting & coping with PCC 1:2:4 type B-1,and brick work in CM 1:4, 15mm thick plastering in cement mortar 1:4, 100 mm thick foundation concrete 1:4:8 type D-2 all as directed by Engineer - in – Charge.Note: Earth work is deemed to be included in quoted amount. |
| 83 | M&L Power Cables, Aluminium Stranded Conductor 150 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supply and laying 150 mm bore tube \"light grade\" galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge. |
| 85 | M & L sand cushioning for under ground cable, one layer of 8 cm thickness before laying the cable and other layer of 15 cm thickness after laying the cable, punned down to 18 cm thickness all as specified and directed by Engineer-in-Charge.Note:- Thickness after punned down shall be considered for payment. |
| 86 | Supplying and laying reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm all as specified and directed by Engineer-in-Charge. |
| 87 | S&F MCCB 250 A ,4 pole ,36 KA(Ics =100% Icu) with adjustable thermal & fixed magnetic settingwith bus bar spreader links forconnecting both incoming and outgoing cables with suitable connections with suitable size ofglands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 88 | S&F MCCB 160 A ,4 pole ,36 KA(Ics =100% Icu) with adjustable thermal & fixed magnetic settingwith bus bar spreader links forconnecting both incoming and outgoing cables with suitable connections with suitable size ofglands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 89 | M & L point wiring complete with 1.5 Sqmm (nominal area) PVC FRLSinsulated unsheathed copper stranded conductor cable with colour code in and including medium grade rigid PVC conduit with tees, bends, elbows, couplers, MS junction boxes concealed after cutting chases in wall, floor etc and making good to match with existing surface including sunken iron terminal box, 3mm thick bakelite sheet cover, clips, pipe hooks, brass screws, washers and 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light /bell point/ fan point/ exhaust fan controlled by one, one way switch all as specified and directed at site by Engineer – in – Charge. |
| 90 | All as per item No.89 here in before but one 6 Amp socket point control by one switch on independent board all as specified and directed by Engineer - in - Charge |
| 91 | All as per item No.89 here in before but one 6 Amp socket point control by one switch on same board all as specified and directed by Engineer - in - Charge |
| 92 | All as per srl item no. 89 here-in-before but with 2.5 sq mmFRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 16 Amp socketpoint controlled by one 16 Amp switchon independent board. |
| 93 | S & F submain wiring with two single core cables PVC FRLS insulatedunsheathed 4 Sqmm stranded copper conductor drawn in and including PVC conduitwith and including PVC insulated 4 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge.Note :PVC cables two single coreand one single core of sizesas mentioned will considered as one unit. |
| 94 | Suppy and laying or fixing or passing through pipe 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed 10 sqmm nominal cross section and 3 core in service connection complete all as specified and as directed |
| 95 | Supply and fixing 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS-14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection complete all as specified and as directed by Engineer-in-Charge. or to common earth and connecting to earth dolly. |
| 96 | Supply and fix switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed. |
| 97 | Supply and fix socket 6 Amps, 2-in-1, 5 pin flush type universal 240V, 50Hz complete all as specified and directed. |
| 98 | Supply and fix switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed. |
| 99 | Supply and fix socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed. |
| 100 | Supply and fix ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed. |
| 101 | Supply and fix electronic fan regulator rotary type in 5 steps 240V, 50Hz complete all as specified and directed. |
| 102 | Supply and fix LED batten with CRCA sheet steel box type body pre-wired suitable for and including provision of 1x20/22 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 1.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge. |
| 103 | Supply and fix LED street/security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of suitable dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washersand provision of 3 core twisted flexible copper cable of size 1.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed by Engineer-in-Charge. |
| 104 | Supply and fix MCB distribution board, SPN, 8 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note:MCBs shall be measured and paid separately. |
| 105 | Supply and fix MCB 40A, 10 KA, SPN, \"C\" curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge. |
| 106 | Supply and fix MCB 6 - 32A, 10 KA, single Pole, \"C\" curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge. |
| 107 | S&F Exhaust fan made of steel body AC single phase , 230V of size 450 mm sweep complete with louvers , frame, shutters and blade . |
| 108 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 109 | Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to and including galvanized earth lead wire 4mm dia by means of GI bolts, nuts, check nuts and washers and connected other end to main board duly protected by GI pipe 15mm bore, medium grade, earth plate surrounded by packed layer of coal dust and common salt 15cm thick all around bottom and top watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate No. 3 of SSR Part – I and connecting to earthing test point, main switch board and testing on completion including CI cover, frame and PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in earthing pit with CI cover and frame including necessary earth works etc, all as specified and directed by Engineer - in – Charge.Note:-1. PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner. |