Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | B/R Portion: -Dismantling AC corrugated, semi corrugated sheets in roof covering complete all as specified and as directed. |
| 2 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/ slabs/ blankets, any thickness any type including cover fillets complete all as specified and as directed. |
| 3 | Dismantling timber scantling in fillets, posts, rafters, purlins etc under 40 Sqcm in section complete all as specified and as directed. |
| 4 | Dismantling stone slabs laid dry and tiles of any description or thickness in floors, aprons etc. and rubbish off the premises complete all as specified and as directed. |
| 5 | Dismantling wrought iron or mild steel work as in wind tie, grill grating, cooler stand etc complete all as specified and as directed. |
| 6 | Demolition of brick work/ stone masonry built in cement mortar including all quoins, arches, pillars, but excluding pre-cast concrete articles complete all as specified and as directed. |
| 7 | Demolition/ breaking of drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar and taking out of trenches and removing the debris from the site all as spceified of 150mm/ 200 mm dia pipe including demolition of cement concrete haunching etc complete all as specified and as directed. |
| 8 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 9 | Taking down chowkhats or frames not exceeding 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed. |
| 10 | Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed. |
| 11 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 12 | Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed. |
| 13 | Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed. |
| 14 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. |
| 15 | Excavation in trenches, not exceeding 1.5m wide not exceeding 1.5m in depth, for foundation, etc, or for shafts, wells cesspits, manholes, pier holes, etc not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in hard/ dense soil complete all as specified and as directed. |
| 16 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed. |
| 17 | Removal of surplus excavated soil to a distance exceeding 250 m and not exceeding 500m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 18 | Brick work with sub class \"B\" old size brick straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 19 | 75mm thick cement concrete (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in floor/ plinth protection laid in suitable panels finished even and fair all as specified. 6mm joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three parts of sand (all by weight) complete all as specified and as directed. |
| 20 | Cement concrete type C-2 (1:3:6) (using 40 mm graded crushed stone aggregate) as in surface channels complete all as specified and as directed. |
| 21 | Providing 75 mm thick plain cement concrete (1:4:8) mix, type D-2 (using 40mm graded crushed stone aggregate) as sub base floor complete all as specified and as directed. |
| 22 | Providing cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 23 | Reinforced cement concrete (nominal mix) (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 24 | 10 mm thick rendering in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 25 | 15 mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces with WPC finished even and smooth without using extra cement complete all as specified and as directed. |
| 26 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPs as in roof covering fixed with self tapping screws or L-type or J-type or cranked hook bolts complete all as specified and as directed. |
| 27 | Providing and fixing in position suspended false ceiling system using \"E\" grid suspended ceiling grid system. The size of grid shall be 600 x 600mm with GI frame work, main runner 39 x 24mm, cross tee 29 x 24mm and wall angle 22.2 x 22.2mm using 4mm thick high pressure stream cured non primered classic/ designer variant E-Board ISI Marked IS No 14862-2000. Fibre cement \"E\" Board to be placed in the grid of \"E\" grid suspended ceiling grid system duly suspended by 4mm dia GI bar hangers from the purlins of the roof with butterfly clips. All electric fittings fixed with ceiling and refixing the same in position after replacing the ceiling complete all as specified and as directed. |
| 28 | Powder coated aluminium three track sliding type glazed window, shutter with 5mm thick plain sheet glass fixed open track section 100 x 38 x 1.4 mm having three track (two of 5.50 mm thick glass and one of stainless steel wire cloth of 0.56 mm dia and 1.18 mm aperture) with members of window shutters of section 38 x 12mm including aluminium grill 75 mm x 5.50 mm thick pitch diamond shape, wire gauge and grill shall be fixed with the help of 40 mm aluminium flat and other standard Bombay sliding section including all necessary fiber wheel rollers suitable handle to facilitate sliding and all necessary jointing cleats glazing clips, rubber packing, Aluminium snap beading etc complete all as specified and as directed. |
| 29 | Aluminium powder coated aluminium door shutters with frame (frame sections not less than 3mm thick, shutter sections not less than 2mm thick. Bottom half panel filled with 8 mm thick prelaminated particle board and top half portion covered with 5.5mm thick frosted glass including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 no\"s in each door, hinges, anodised aluminium snap beading, screws, two way floor door spring, mortise lock with keys etc. complete all as specified and as directed. |
| 30 | Aluminium powder coated partition made out of aluminium frame sections not less than 3.0 mm thick and shutter/ middle sections not less than 2.0 mm thick, including all necessary accessories. The bottom half of the partition shall be fitted with 8 mm thick prelaminated particle board (both sides decorative laminate) fixed with appropriate aluminium snap beading. The top half shall be glazed with 5.5 mm thick frosted glass, fixed using glazing clips and neoprene/ rubber packing complete all as specified and as directed. |
| 31 | 12mm thick frosted toughened glass as in partitions and similar work including cutting to shape rounded corners, drilling holes fixed to wall with two pairs of stainless steel clamp to wall clamp complete all as specified and as directed. |
| 32 | Supply and fixing in repair curtain rod of stainless steel 20mm dia and side caps fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screws complete all as specified and as directed by Engineer-in-Charge. |
| 33 | Supply and fixing in repair 18mm thick single layered HDHMR board one side white balanced and other exterior side with 0.9 mm thick decorative sunmica type 1 coloured textured finish board density more than 850 Kg / cum smooth finished fixed in cupboard and jointed together with necessary adhesive complete all as per directions by Engineer-in-Charge, manufacturer’s specification complete all as specified and as directed. |
| 34 | Structural steel section work as in roof trusses (framed), post, trussed, purlins, rafters, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections or mild steel tube pipe) and rolled steel section work as in main and cross beam, purlin, rafter, tubular poles, including distance pieces, cleats etc Fe-410W (Grade E-250) quality including shop coat of primer complete all as specified and as directed. |
| 35 | Mild steel framed works such as grills, framed guard bars, etc and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed. |
| 36 | TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns and binding with and including mild steel wire annealed not less than 0.9 mm dia conforming TMT bars complete all as specified and as directed. |
| 37 | Description all as per Ser item No 36.00 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups dia complete all as specified and as directed. |
| 38 | Form work to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished complete all as specified and as directed. |
| 39 | Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and as directed. |
| 40 | Preparation of new surface and applying two coats of oil bound distemper over new plastered surface over 1 mm thick putty complete all as specified and as directed. |
| 41 | Preparation of new surface and applying two coats of exterior emulsion/ weather proof paint over a coat of primer over and including 1mm thick putty on plastered surface complete all as specified and as directed. |
| 42 | Complete removal of existing surface and preparation of old surface and applying two coats of exterior emulsion/ weather proof paint over a coat of primer over and including 1 mm thick putty on plastered surface complete all as specified and as directed. |
| 43 | Complete removal of existing surface and preparation of old surface and applying two coats of oil bound distemper over 1 mm thick putty complete all as specified and as directed. |
| 44 | Provision of roof treatment with elastometric water proofing membrane all as given below:-(a) Taking down existing water proofing treatment and cleaning roof surface by washing and rubbing etc. and removing the material retrieved to a distance not exceeding 500 m where directed.(b) M&L for plastering 10mm thick in cement mortar (1:3) using 100% coarse sand on roof surface including water proofing compound as per manufacturer\"s instructions and as directed by Engineer-in-Charge.(c) Applying one coat of primer of acrylic reinforcement liquid elastometric water proofing membrane with UV resistant properties and solar reflective properties (3:1 water dilution) on prepared surface with roller and allowed to dry.(d) Supply and applying two coats of undiluted thick coat of acrylic reinforcement liquid applied elastometric water proofing membrane with UV resistant properties and solar reflective properties before first coat insert smart care roof tape corner/ joints and allow it to dry then apply further second coat complete all as specified and as directed.Note: - Every coat time gap should be minimum 6 hrs and thickness of each coat 2-3mm. |
| 45 | Non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm screed bed cement mortar (1:6) complete all as specified and as directed. |
| 46 | Vitrified tiles any colour 10 mm thick (square/ rectangular) polished as in floor, area of each tile not exceeding 0.36 Sqm etc set and jointed over neat 5-6 mm thick approved polymer modified tile adhesive of appropriate grade as per manufacturer\"s instructions and laid with 3-4mm spacer, spacer gaps to be filled with approved epoxy grout and including screed bed or bedding layer of mortar 15 mm thick cement mortar (1:6) for laying floor finishes complete all as specified and as directed. |
| 47 | Description all as per Ser item No 46.00 here-in-before but in vertical surfaces with fixed with 3-4 mm spacer set and jointed over neat 5-6 mm thick approved tile adhesive polymer modified tile adhesive of appropriate grade as per manufacturer\"s instructions and provided with 3-4mm spacer, spacer gaps to be filled with approved epoxy grout and including plastering 10 mm thick cement mortar (1:4) complete all as specified and as directed. |
| 48 | Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster (1: ½: 2) (1 cement : ½ coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings complete all as specified and as directed. |
| 49 | 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills cooking platforms and like in cement mortar (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite including taking down old complete all as specified and as directed. |
| 50 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness and size/ shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 51 | Providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and as directed. |
| 52 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 53 | Modular auto concealed soft closed hinges 35mm, 160 degree size fixed to cupboard complete all as specified and as directed. |
| 54 | 304 grade stainless steel handle 100mm fixed to cupboard complete all as specified and as directed. |
| 55 | Magnet catcher 50 mm size for kitchen cupboard shutter complete all as specified and as directed. |
| 56 | GI spout 25mm dia light grade, fixed to walls complete all as specified and as directed by Engineer-in-Charge. |
| 57 | Supply and fixing in repair chromium plated brass bib taps with wall flange 15mm fancy type chromium plated cast copper alloy with quarter turn handle and wall flange complete all as specified and as directed. |
| 58 | Supply and fixing in repair 15 mm bore sawn neck pillar cock cast copper alloy, chromium plated with angular knob fixed to 15mm dia pipe complete with all fittings complete all as specified and as directed. |
| 59 | Supply and fixing in repair Single lever Wall mixer 3 in 1 system with provision of over head shower complete with 115mm long bend pipe on upper side connecting legs and wall flanges (without over head shower) including all fittings and fixed complete all as specified and directed. |
| 60 | Supply and fixing in repair chromium plated brass stop/ angle valves 15mm bore fancy type chromium plated with quarter turn handle and wall flange complete all as specified and as directed. |
| 61 | Supply and fixing in repair Overhead shower 200 x 200mm square shape single flow (ABS body chrome plated with grey face plate) with rubit cleaning system including shower arm 450mm long including all fittings and fixed complete all as specified and as directed. |
| 62 | Supply and fixing in repair fancy type brass chromium plated towel ring round with round flange including necessary fittings complete all as specified and as directed. |
| 63 | Supply and fixing in repair Vitreous china Water closet pedestal pattern cascade type with in built flushing cistern and seat cover with complete fitting all as specified and as directed. |
| 64 | Supply and fixing in repairs Stop cock, chromium plated fancy type screwed down high pressure, with crutch of butterfly handle, screwed both ends for iron pipe of size 15mm dia bore complete all as specified and as directed. |
| 65 | Supply and fixing in repair for 15mm bore chromium plated sink mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and as directed. |
| 66 | Supply and fixing in repairs two way cock/ two way angle cock with wall flange matt chrome finish complete all as specified and as directed. |
| 67 | Supply and fixing in repair 500 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position and including dismantling of water tank complete all as specified and as directed. |
| 68 | Supply and fixing in repair PVC connection 15mm bore and for 600 mm long with brass or PVC nuts and PVC washer complete all as specified and as directed.Makes: - Prima Cat Part No PCD-1274 or equivalent in makes as specified in Group - I of Appx \"F\". |
| 69 | Supply and fixing in repair PVC waste pipe 32mm bore complete all as specified and as directed.Makes: - Prima Cat Part No PCD-1283 or equivalent in makes as specified in Group - I of Appx \"F\". |
| 70 | Supply and fixing in repair for fancy type brass chromium plated toilet paper holder with flap including all fittings and fixed complete all as specified and as directed. |
| 71 | Supply and fixing in repair chromium plated 125mm soap dish in position complete all as specified and as directed by Engineer-in-Charge.Make: - Prima Cat Part No PDX-4501-G or equivalent in makes as specified in Group - I of Appx \"F\". |
| 72 | Supply and fixing in repair Cabinet mirror plastic body for toilet of size 450 x 600mm with 4mm thick looking mirror complete all as specified and as directed.Makes: - Prima Cat Part No PCD-1631 or equivalent in makes as specified in Group - I of Appx \"F\". |
| 73 | Supply and fixing fancy type decorative pattern with selected quality glass 5.5mm thick bevelled edge fixed on wall with 4 No\"s 15mm dia stainless steel mirror button stud complete all as specified and as directed. |
| 74 | 15 mm dia galvanized pipes medium grade with all fittings and fixed complete wall and ceiling or laid in floors complete all as specified and as directed. |
| 75 | 20 mm dia galvanized pipes medium grade with all fittings and fixed complete wall and ceiling or laid in floors complete all as specified and as directed. |
| 76 | Supply and fixing in repairs 125 mm chromium plated stainless steel grating with or without waste hole complete all as specified and as directed. |
| 77 | Supply and fixing in repair stainless steel kitchen plate rack made out of not less than 0.63mm thick stainless steel sheet of size 750mm x 600mm x 250mm of approved pattern complete all as specified and as directed. |
| 78 | Supply and fixing in repair health faucet (hand shower) with 1 mtr flexible tube with hot and cold water supply wall hook, bracket etc complete set of superior quality complete all as specified and as directed. |
| 79 | Supply and fixing in repair glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket, guard and railing 60cm long complete all as specified and as directed. |
| 80 | Supply and fixing in repair Vitreous china under counter type wash basin oval size 555 x 425 x 195mm including all fittings complete all as specified and as directed. |
| 81 | Supply and fixing in repairs Vitreous chinaware wash hand basin white, flat back of size 550 x 400 mm excluding tap but including brackets fixing to wall and two No\"s 10mm dia 100mm long nut and bolt over brackets and chromium plated waste coupling complete all as specified and as directed.Makes: - Hindware (Ist Quality)/ Parryware (Super fine)/ Cera (Ist Quality), Cera Cat Part No CLAIR S2040157 or equivalent in makes as specified in Group - I of Appx \"F\". |
| 82 | Supply and fixing in repairs 20 mm dia gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe complete all as specifed and as directed. |
| 83 | Supply and fixing in repair mild steel peg set of six power coated as approved by GE complete all as specified and as directed. |
| 84 | Supply and fixing in repair brass chromium plated towel rail 20 mm dia \"D\" type 60 cm long between flanges complete all as specified and as directed. |
| 85 | Supply and fixing in repair sinks with drainage board made of stainless steel 1 mm thick in kitchen with plugs, washers and waste coupling, waste pipe, including bedding in cement mortar on wall including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460 mm, bowl size 410mm x 330mm x 160 mm complete all as specified and as directed. |
| 86 | Concrete bed to 150 mm bore pipe (1:4:8) in type D-2 (using 40mm graded crushed stone aggregate) including haunching against the sides of pipe complete all as specified and as directed. |
| 87 | Supply and fixing and laying 150 mm thick reinforced concrete pipes class NP-2 laid and jointed complete with collars as in trenches complete all as specified and as directed. |
| 88 | Supply and fixing in repairs perforated precast 100 mm thick M-30 RCPC manhole cover, min 800 to 900 mm dia/side of clear opening circular/ rectanuglar and including collar frame set and including lifting hook (02 No\"s) complete fixed in position over existing manholes complete all as specified and as directed by Engineer-in-Charge. |
| 89 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement complete all as specified and as directed. |
| 90 | 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, bends, Tees complete fixed to walls at any height complete all as specified and as directed. |
| 91 | 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, bends, Tees complete laid in trenches or in floors complete all as specified and as directed. |
| 92 | 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, bends, Tees complete fixed to walls at any height complete all as specified and as directed. |
| 93 | 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, bends, Tees complete laid in trenches or in floors complete all as specified and as directed. |
| 94 | PVC (SWR) bends 110 mm radius complete all as specified and as directed. |
| 95 | 110 mm PVC (SWR) junction single (T) equal/ unequal complete all as specified and as directed. |
| 96 | PVC (SWR) bends/ shoes any radius of 75 mm dia complete all as specified and as directed. |
| 97 | PVC (SWR) bends any radius provided with access door of 110mm dia complete all as specified and as directed. |
| 98 | Description all as per Ser item No 97.00 here-in-before but 75 mm dia complete all as specified and as directed. |
| 99 | PVC (SWR) vent cowl of radius of 75 mm dia complete all as specified and as directed. |
| 100 | Supply and fixing in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 complete all as specified and as directed. |
| 101 | Supply and fixing Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roof for 75 mm bore pipe complete all as specified and as directed. |
| 102 | Supply and fixing Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roof for 100mm bore pipe complete all as specified and as directed. |
| 103 | Supply and fixing in repair Dressing table for ladies alongwith sitting stool with side drawer both side two no\"s each overall size at bottom will be 2.00 x 0.60 x 0.40 mtr with mirror size of 5.5mm thick 0.40 x 1.50mtr fixed on wooden frame. All work carried out with 18mm thick HDMR Board alongwith hardware and sliding channels complete all as specified and as directed. |
| 104 | E/M Portion: -Taking down old unserviceable copper/ aluminium point wiring concealed/ batten (light, fan, socket or power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden/ iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed. |
| 105 | Material and labour in replacement for Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 3 run 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall after cutting chases. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed.Note: - Wiring shall be done in proper colour coding. |
| 106 | Material and labour for complete point wiring for light/ fan point with 1.5 Sqmm two single core multistranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 Sqmm copper conductor flexible FRLS insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall, plastering after concealing conduit, including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer-in-Charge for the following: - |
| 107 | Description all as per Ser item No 106.00 here-in-before but for multi 5 pin 5 amp socket outlet on same board complete all as specified and as directed. |
| 108 | Description all as per Ser item No 106.00 here-in-before but for multi 3 pin socket outlet 5 amp socket on independent board complete all as specified and as directed. |
| 109 | Description all as per Ser item No 106.00 here-in-before but for multi 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green colour complete all as specified and as directed. |
| 110 | Supply and fixing modular socket, 6A - 5 pin combined 2 module, 240 Volts ISI marked complete all as specified and as directed. |
| 111 | Supply and fixing modular switch 1 way 6A, 1 module, 240 Volts ISI marked complete all as specified and as directed. |
| 112 | Supply and fixing ceiling rose, 3 Phase/ PVC/ polycarbonate isolated body complete all as specified and as directed. |
| 113 | Supply and fixing modular switch 1 way 16A, 1 module, 240 Volts ISI marked complete all as specified and as directed. |
| 114 | Supply and fixing modular socket 6A/16A - 6 pin combined 2 module, 240 Volts ISI marked complete all as specified and as directed. |
| 115 | Material and labour in replacement for lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 116 | Material and labour in replacement self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed. |
| 117 | Supply and fixing in replacement LED light fittings 1 x 20 W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.90, 100 Lumen/Watt, 6500K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4\" ft long) with LED rod 20 watt, 230 Volts, 50 Hz complete all as specified and as directed. |
| 118 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 119 | Supply and fixing LED light fitting mirror type with high output diffuser 2 ft, 10 watt, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 120 | Supply and fixing ceiling fans complete with blades, down rods suitable for working on electronic regulator and accessories, 230 V, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 121 | Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250mm complete all as specified and as directed. |
| 122 | Supply and fixing exhaust fan, steel body AC single phase, 230V of size 300mm sweep with blades and frame and louvers complete all as specified and as directed. |
| 123 | Supply and fixing LED light fitting 1 x 9W/ 1 x 10 W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 124 | Supply and fixing modular bell push 6A, 1 module complete all as specified and as directed. |
| 125 | Supply and fixing buzzer, Ding Dong AC, 230 Volts, single pole complete all as specified and as directed. |
| 126 | Supply and fixing electric water heater, storage type steel body with inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and as directed. |
| 127 | Material and fixing for fixing of 4 Nos rawl plug of suitable size (4\" - 6\") nuts and bolts for hanging of geysers on wall complete all as specified and as directed. |
| 128 | Material and labour for tubing GI \"medium grade\" with all fittings laid on floor/ wall of size 15mm dia complete all as specified and as directed. |
| 129 | Supply and fixing angle valves, fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, fancy type, screwed both ends for iron pipe or for unions and fixed for 15mm dia of pipe complete all as specified and as directed. |
| 130 | Supply and fixing CP connection of size 15mm dia, SS braided with nuts of length 600 mm long (hot series braided, threaded and cold series) complete all as specified and as directed. |
| 131 | Supply and fixing bib tap cast copper alloy (CP) with crutch or butterfly handle screwed down, chromium plated for iron pipe for brass ferrule of size 15mm bore complete all as specified and as directed. |
| 132 | Material and labour for cutting to existing GI pipe of size 25/ 20/ 15mm dia in position for addition/ alteration or insertion of TEE for branch connection complete with cutting, threading and jointing/ fixing including GI fitting as per site requirement complete all as specified and as directed. |
| 133 | Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 Volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCBs should be of same make. |
| 134 | Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 Volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCBs should be of same make. |
| 135 | Supply and fixing and fabrication security light bracket made out of 32mm light grade GI tubing suitable for 35 watt LED light grade upto 1.2 mtr length, bend to shape suitable with necessary mild steel clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed. |
| 136 | Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed. |
| 137 | Supply and fixing modular fan step regulator, 120 W - 2 module complete all as specified and as directed. |
| 138 | Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolts, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 precast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20 mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part - I and testing on completion complete all as specified and as directed. |
| 139 | Supply and fixing in replacement SPN 63 Amp rating 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed. |
| 140 | Supply and fixing in replacement 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amp complete with connection, testing and commissioning complete all as specified and as directed. |
| 141 | Supply, laying for replacement of unserviceable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated and PVC outer sheathing with aluminium stranded conductor, armoured cable 25 Sqmm 4 core cable conforming to IS-7098 Part - I (1988) complete all as specified and as directed. |
| 142 | Supply and laying dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trenches complete all as specified and as directed. |
| 143 | Supply and laying dry bricks over cable as mechanical protection laid flat with width equal to length of brick with sub class \"B\" bricks complete all as specified and as directed. |
| 144 | Material and labour for GI pipe \"light grade\" for passing of cable through road/ on wall/ on pole with fixed clamps, nuts, bolts for cable protection of size 80mm dia complete all as specified and as directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy