| Sl. No. | Item Description |
| 1 | B/R Portion: -Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed. |
| 2 | Demolition of cement concrete (unreinforced) or tiling etc in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 3 | Dismantling/ disconnecting/ demolition of water storage tank of any type or description PVC exceeding 500 and not exceeding 1000 litres capacity complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 5 | Taking down cement plaster on brick/ stone/ concrete surfaces on wall/ ceiling surface or any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 6 | Taking down chowkhats or frames including shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each complete all as specified and as directed. |
| 7 | Taking down chowkhats or frames including shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed. |
| 8 | Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each complete all as specified and as directed. |
| 9 | Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings complete all as specified and as directed. |
| 10 | Taking down GI tubing of 25mm dia and connection and inch cleaning for refixing or removal complete all as specified and as directed. |
| 11 | Brickwork with sub class \"B\" bricks (old size), straight or curved on plan exceeding 6m in mean radius, built in cement mortar (1:6) complete all as specified and as directed. |
| 12 | 75mm thick sub base as in cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) complete all as specified and as directed. |
| 13 | PCC (1:3:6) nominal mix, type C-0 (using 12.5mm graded crushed stone aggregate) as in filling of pressed steel door frames/ chowkhats complete all as specified and as directed. |
| 14 | 75mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection laid to an outward slope of not less than (1:12), cast in panels not exceeding 2.0 Sqm areas with 6mm wide joints. The joint shall be filled with mastic filling and 10mm wide joints between the walls and plinth protection shall be filled with mastic filling and finishing cement concrete surface even and fair complete all as specified and as directed. |
| 15 | Rendering 5mm thick cement plaster (1:3) on fair faces of concrete surfaces as in ceiling, chajja, shelves etc finished even and smooth without using extra cement complete all as specified and as directed. |
| 16 | Rendering 10mm thick cement plaster (1:6) on other than fair faces of brick work or concrete surfaces and finished fair and even complete all as specified and as directed. |
| 17 | Rendering 15mm thick cement plaster (1:4) on fair faces of brick work or concrete surfaces and finished fair and even including water proofing compound complete all as specified and as directed. |
| 18 | Machine cut Kota stone slab flooring 18 to 25 mm thick laid over and including 15mm thick screed base in cement mortar (1:6), jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine complete all as specified and as directed. |
| 19 | Machine cut Kota stone slab in skirting, step dado etc, 18 to 25mm thick laid over and including 10mm thick backing coat in cement mortar (1:4), jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine complete all as specified and as directed. |
| 20 | Non skid ceramic jointless coloured tiles, 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar (1:6) complete all as specified and as directed. |
| 21 | Non skid ceramic jointless coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in skirting, dado etc set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick screed layer in cement mortar (1:4) complete all as specified and as directed. |
| 22 | Non skid ceramic jointless coloured tiles, 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar (1:4) complete all as specified and as directed. |
| 23 | Glazed ceramic coloured tiles of size 450mm x 300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc, set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and as directed. |
| 24 | 16 to 20mm thick granite black (of any type) work (tabled rubbed and polished) in steps, jambs, pillars, window cills cooking platforms and like including pointing into white cement (1:2) using marble dust with admixture of pigment to match the shade of granite laid over and including screed bed of bedding layer of mortar 15mm thick for laying floor in cement mortar (1:4) finished even and rough to receive top layer complete all as specified and as directed. |
| 25 | Pressed steel frames of size 125mm x 60mm made of 1.25mm thick mild steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate complete all as specified and as directed.Note: - PCC for filling of hollow portion shall be measured and paid for separately. |
| 26 | Pressed steel frames of size 105mm x 60mm made of 1.25mm thick mild steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate complete all as specified and as directed.Note: - PCC for filling of hollow portion shall be measured and paid for separately. |
| 27 | 35mm thick factory made second class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides. The size of rail and style as per IS-1003 (Part - I), kiln seasoned and chemically pressure treated, fitted to chowkhats complete all as specified and as directed. |
| 28 | 35mm thick second class hard wood (Sal/ Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in clause 8.24 (a) of SSR Part-I complete all as specified and as directed. |
| 29 | Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part - II complete all as specified and as directed. |
| 30 | Factory made solid PVC moulded door shutter with particle board core 28 to 30 mm thick (Stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing complete all as specified and as directed. |
| 31 | Powder coated aluminium sliding window (three track) consisting of two shutters of glazed and one shutter of flyproof complete all as specified and as directed.Note: - The items shall be included as following: -(a) Aluminium powder coated frame of section 100 x 44mm x 1.5 mm with or without rebate.(b) Aluminium powder coated window shutters of section 40 x 20mm x 1.5mm thick (Two shutter of glass and one shutter of wire mesh) including self locking catch and roller etc.(c) 4.0mm thick coloured or tinted glass glazing as in aluminium door/ window/ ventilator with aluminium hollow beading/ glazing clip (included with shutters) size 19mm x 17mm made out of 0.70mm thick hollow section weighing not less than 0.97 Kgs/ RM including rubber gasket.(d) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples. |
| 32 | Powder coated aluminium ventilator consisting of half portion fixed with 4mm frosted glass and another half portion louvers with mosquito proofing and also provision of exhaust fan complete all as specified and as directed.Notes: - The items shall be included as following: -(a) Aluminium powder coated frame of section 100 x 44mm x 1.5mm with or without rebate.(b) 4.0 mm thick coloured or tinted glass glazing as in aluminium door/ window/ ventilator with aluminium hollow beading/ glazing clip (included with shutters) size 19mm x 17mm made out of 0.70mm thick hollow section weighing not less than 0.97 Kgs/ RM including rubber gasket.(c) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples. |
| 33 | Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks or galvanized with staples including one coat of red oxide primer complete all as specified and as directed. |
| 34 | 25mm outer dia stainless steel decorative drapery rod (Model No - SS-25FL of Vista) of thickness 20 gauge with 50 mm Dia and proportionate for part there off, with stainless steel brackets (Model: - SS 25 BR, Vista) near to ends with stainless steel finials (Model: - SS-1 of Vista with adapter) for 25mm dia drapery rod at both ends complete all as specified and as directed.Note: - The drapery rod shall be projecting 150mm outer side from the closer/ opening of doors/ windows (including necessary fittings). |
| 35 | Sink with drainage board made of stainless steel 1mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and as directed. |
| 36 | Vitreous china wash basin, white flat back, size 550 x 400mm excluding taps, waste chain and plug and porcelain stopper but including vitreous China pedestal and PVC waste pipe with union, flexible suitable for wash hand basin or urinal, 32mm dia complete all as specified and as directed. |
| 37 | Pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanks and fly nuts screwed for 15mm dia bore of pipe complete all as specified and as directed. |
| 38 | 600 x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 39 | Butt hinges 100 mm long, stainless steel, medium weight and fixed complete all as specified and as directed. |
| 40 | Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed. |
| 41 | Aluminium, anodised, barrel tower bolts 200mm of extruded section and fixed complete all as specified and as directed. |
| 42 | Aluminium, anodised, handles 150mm of extruded section and fixed complete all as specified and as directed. |
| 43 | Floor door stopper of 140mm long cover plate of aluminium alloy body and tongue anodised with hard drawn steel spring, fixed in floor complete all as specified and as directed. |
| 44 | Rotational moulded polyethylene water storage tank with plastic lid cover, triple layered, cylindrical vertical with closed top hoisted and fixed in position of capacity 1000 litre including making connections complete all as specified and as directed. |
| 45 | Stop valve 20mm dia cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 46 | Ball valve 20mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed. |
| 47 | Cutting chases for concealed water tubing or concealed conduit and making good in cement mortar (1:3) of girth exceeding 10 cm and not exceeding 20 cm in brick wall complete all as specified and as directed. |
| 48 | 20mm outer dia CPVC pipe SDR 11 fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.Note: - The rate for pipe including all pipe fittings such as ends, elbows, unions, tees reducing tees, adapters, sockets, plugs, house clips as well as brass threaded fittings for all opening/ connections such as Bib taps/ Stop valve etc. |
| 49 | 25mm outer dia CPVC pipe SDR 11 fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.Note: - The rate for pipe including all pipe fittings such as ends, elbows, unions, tees reducing tees, adapters, sockets, plugs, house clips as well as brass threaded fittings for all opening/ connections such as Bib taps/ Stop valve etc. |
| 50 | Chromium plated cast copper alloy Bib tap 15mm bore long body, brass chromium plated, fancy type (long shank) with crutch or butterfly handle screwed down, screwed for iron/ PVC pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 51 | Stop valve/ Angle valve fancy type, chromium plated screwed down, high pressure with crutch or butterfly handle screwed both ends for iron/ PVC pipe or for unions of 15mm bore complete all as specified and as directed. |
| 52 | Stop valve/ Angle valve (ISI marked), fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron/ PVC pipe or for unions of 15mm bore complete all as specified and as directed. |
| 53 | Chromium plated overhead shower rose with or without swivel joints, 125mm complete all as specified and as directed.Make: - Prayag Cat Part No BS-29 or equivalent in makes as specified in Group - I of Appx \"F\". |
| 54 | Brass chromium plated towel rail 20mm dia \"D\" type 60 cm long between flanges complete all as specified and as directed. |
| 55 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed. |
| 56 | PVC connection 15mm bore with PTMT nuts of length 450mm long complete all as specified and as directed. |
| 57 | PVC (SWR) floor trap, dia of outlet in 75mm, plain excluding grating but including jointing with solvent cement fixed in repair complete all as specified and as directed. |
| 58 | Vitreous china squatting pan of pattern, long pan, \"Orissa pattern\", size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) but including provision of lime concrete complete all as specified and as directed. |
| 59 | PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle (including brackets and flush pipe PVC 32mm dia) capacity of 10 litres complete all as specified and as directed. |
| 60 | Soap dish cantabile-clear (material stainless steel finish, glossy) fixed to plugs with chromium plated brass screws complete all as specified and as directed.Make: - Prayag Cat Part No BA-155 or equivalent in makes as specified in Group - I of Appx \"F\". |
| 61 | PVC (SWR) pipes 110mm bore single socketed in any length with rubber joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and as directed. |
| 62 | PVC (SWR) pipes 75mm bore single socketed in any length with rubber joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and as directed. |
| 63 | PVC (SWR) bends of 110mm bore complete all as specified and as directed. |
| 64 | PVC (SWR) bends of 75mm bore complete all as specified and as directed. |
| 65 | PVC (SWR) junction double (double T) equal or unequal provided with access door of 110mm dia complete all as specified and as directed. |
| 66 | PVC (SWR) vent cowl 110mm bore complete all as specified and as directed. |
| 67 | Supply only water proofing compound complete all as specified and as directed. |
| 68 | Preparing of new or previously untreated surfaces of wood of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 69 | Preparation of new or previously untreated steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 70 | Complete removal of the existing roof treatment any nos of layers taken out membrane, PCC Padding/ roof, tiles etc including grabbing up of tree roots, roughening and preparation of surfaces of old concrete floor by picking, scrubbing down with steel brushes, sweeping, cleaning and washing down with water to remove dust etc and applying Home Shield PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied, water proofing membrane that is highly elastic and UV resistant with 10 years warranty. ASTM D 6083-97a Waterproofing and heat reflecting system having following key performance properties complete all as specified and as directed. (i) UV resistant, prevent yellowing and weathering. (ii) Highly elastic upto 350% and crack bridging. (iii) Excellent adhesion on porous and non-porous substrates. (iv) Tensile strength >10 N/Sqmm with Geotextile fleece. (v) Solar Reflective Index (SRI) more than 109-111 ASTM E 1980-11. System : First coat : Providing and applying primer over the prepared surface with HS PU roofkoat primer (or equivalent), Coverage : 0.2 Kg/Sqm (with 50% dilution of water), Reinforcement : Geotextile 40 gsm, Second coat : Home shield roofkoat (or equivalent), Consumption : 0.5 Kg/Sqm, Third coat : HS PU roofkoat (or equivalent), Consumption : 0.8 Kg/Sqm. System buildup - 1.5 Kg/Sqm with geotextile of 40 gsm. |
| 71 | Supply only PU Roofkoat primer complete all as specified and as directed. |
| 72 | Supply only Geotextile 40 gsm complete all as specified and as directed. |
| 73 | Supply only Home shield PU Roof koat complete all as specified and as directed. |
| 74 | Supply only HS PU Roofkoat complete all as specified and as directed. |
| 75 | Preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of primer including wall care putty white or tinted shade complete all as specified and as directed. |
| 76 | Complete removal of existing treatment on wall/ ceiling/ chajjas/ cornices etc or any surface or any description with brooming down or steel wire brushing, scrapping down with steel blade smoke root, moulds, moss and efflorscent salt and trading oil and greasy spot/ surface including scaffolding, trestle, ladder, craddles etc and protective measures, removing nails, making good holes, cracks etc and removing and replacing furniture, movable cupboard, chicks, blind etc complete all as specified and as directed. |
| 77 | Applying for 3mm thick wall care cement putty, white or tinted shade complete all as specified and as directed. |
| 78 | Applying two coats of oil bound distemper over one coat of primer, white or tinted shade, including washing floors, cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premise clean and tidy and also spreading and removing covering to doors, window floors, fittings, etc to protect them from splashes complete all as specified and as directed. |
| 79 | Preparing of old painted surfaces of steel or iron surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 80 | Preparing of old painted surfaces of wood of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 81 | Preparing newly plastered surfaces and applying three coats of white wash as in ceiling etc complete all as specified and as directed. |
| 82 | Preparing of plastered surfaces of ceiling, old decorated surfaces and applying two coats of white wash complete all as specified and as directed. |
| 83 | Preparation of newly/ old plastered surfaces of wall and applying two or more coats of 100% Premium exterior grade acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior paint applied @ 0.90 litre/ 10 Sqm over new surfaces, white or tinted shade complete all as specified and as directed. |
| 84 | Framed work such as grills, gratings etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 85 | E/M Portion: -Taking down old unserviceable copper/ aluminium point wiring concealed/ batten (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden/ iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 86 | Taking down carefully unserviceable distribution boards any type/ size with MCCBs/ MCBs/ Isolators etc and disconnecting and making good disturbed surfaces complete all as specified and as directed. |
| 87 | Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed.Note: - Wiring shall be done in proper colour coding. |
| 88 | Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed.Note: - Wiring shall be done in proper colour coding. |
| 89 | Complete point wiring with 1.5 Sqmm single core multistranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 Sqmm copper conductor flexible FRLS insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall, plastering after concealing the conduit including modular galvanised flush boxes of suitable size and white cover plate as per site requirement with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer-in-Charge for the following: - |
| 90 | Description all as per Ser item No 89.00 here-in-before but for multi 5 pin 5 amp socket on same board complete all as specified and as directed. |
| 91 | Description all as per Ser item No 89.00 here-in-before but for multi 3 pin socket outlet 5 amp socket on independent board complete all as specified and as directed. |
| 92 | Description all as per Ser item No 89.00 here-in-before but for multi 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green colour complete all as specified and as directed by Engineer-in-Charge. |
| 93 | Supply and fixing modular switch 1 way 6A, 1 module, 240 Volts ISI marked complete all as specified and as directed. |
| 94 | Supply and fixing modular socket, 6A - 5 pin combined 2 module, 240 Volts ISI marked complete all as specified and as directed. |
| 95 | Supply and fixing modular switch 1 way 16A, 1 module, 240 Volts ISI marked complete all as specified and as directed. |
| 96 | Supply and fixing modular socket 6A/16A - 6 pin combined 2 module, 240 Volts ISI marked complete all as specified and as directed. |
| 97 | Supply and fixing ceiling rose, 3 Phase/ PVC/ Polycarbonate isolated body complete all as specified and as directed. |
| 98 | Material and labour for fan regulator stepped electronic type suitable for AC, 240 Volts complete all as specified and as directed. |
| 99 | Material and labour for lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 100 | Material and labour self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500 K complete all as specified and as directed. |
| 101 | Supply and fixing LED lights fitting 1 x 10W, 220V, AC decorative box type complete with LED tube rod 10 watts driver, holder and power factor >0.95, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4\" ft long) complete all as specified and as directed. |
| 102 | Supply and fixing LED lights fitting 1 x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4\" ft long) complete all as specified and as directed. |
| 103 | Supply and fixing LED light fittings 1 x 9W/ 1 x 10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 104 | Supply and fixing in replacement distribution board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB\"s and should be IP-43 protected with copper bus bars, neutral links, earthing bar complete all as specified and as directed including taking down old unserviceable distribution board/ MCB any type complete all as specified and as directed.Notes: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 Volts with adjustable thermal settings.(ii) MCB\"s shall be measured and paid separately.(iii) TPN distribution board and MCCB should be of same make. |
| 105 | Supply and fixing 415V, 10 KA \"B\" curve MCB TPN 63 Amp capacity in each distribution board complete all as specified and as directed. |
| 106 | Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 Volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCB\"s should be of same make. |
| 107 | Supply and fixing in replacement SPN 40 to 63 Amps rating 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning all as specified and as directed. |
| 108 | Supply and fixing in replacement 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed. |
| 109 | Supply and fixing in replacement metal body exhaust fan 450mm made of sturdy Engineering plastic complete with louvers, shutters, voltage 230 V, 50 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and as directed.Note: - Contractor will deposit old unserviceable fan to MES store yard for their further action. |
| 110 | Supply and fixing in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and as directed.Note: - Contractor will deposit old unserviceable fan to MES store for their further action. |
| 111 | Supply and fixing in replacement Ceiling fans, BLDC motor tech complete with blades, down rods, hanging hooks and accessories, 230 V, 1200mm sweep, suitable for working on fan regulator, minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete with fixing arrangement complete all as specified and as directed.Note: - Contractor shall deposit old unserviceable fan to MES store yard. |
| 112 | Supply and laying for replacement of unserviceable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated and PVC outer sheathing with aluminium stranded conductor, armoured cable 25 Sqmm 4 core cable conforming to IS-7098 Part - I (1988) with latest amendments of sizes complete all as specified and as directed. |
| 113 | Excavation in trenches not exceeding 1.5m in width and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 114 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed. |
| 115 | Removal of excavated surplus material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 116 | Material and labour for cutting of bituminous road/ floor/ culvert/ PCC hard standing for laying of pipe/ cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling/ with material and watering, well ramming/ compacting and making good with PCC (1:2:4) type B-1, 100 mm thick complete all as specified and as directed. |
| 117 | Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nuts, bolts, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 precast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal etc complete all as shown in electrical plate No 3 of SSR Part - I and testing on completion complete all as specified and as directed. |