| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 2 | Dismantling timber scantlings in unframed work 40 sq. cm and over in section fixed in any position complete all as specified and as directed. |
| 3 | S&F Rolled sections of grade Fe 410W (Gde E-250)as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 4 | M&L for Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide zinc chrome primercomplete all as specified and as directed. |
| 5 | Dismantling AC corrugated or semi corrugated etc sheets /Mangalore pattern tiles of any description in roof coverings complete all as specified and as directed. |
| 6 | M&L for Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of anycolour having tensile strength of 550 Mpa as in roof covering/ cladding towall, fixed with self tapping screws complete all as specified and directed.Note:- Rate shall be inclusive of making good disturbed portion with two coats of OBD. |
| 7 | S&FPre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as on roof covering/ridgesfixed with self tapping screws complete all as specified and directed. |
| 8 | M&L for cement concrete Type B1 1:2:4 (using 20mm graded crushed stone aggregate) as incopings and the like ncluding weathering,slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 9 | M&L for precast cement concrete block masonry exc. 10 cm width with solid blockC1 (1:3:6) (using 20 mm graded cushed stone aggregate) and settingin cement mortar (1:6) complete all as specified and as directed. |
| 10 | M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM (1:6) even and smooth without using extra cement complete all as specified and as directed. |
| 11 | M&L for preparation of new plastered or un- plastered surfaces and walls including cornices, pilasters etcand applying two Coats of cement base paint over a coat of cement primer complete all as specified and as directed. |
| 12 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 13 | Providing and fixing tiled false ceiling of size(600x600)mm in true horizontal level suspended on interlocking T-24Grid of hot dipped galvanized corrosion free becase of the zinc coating 120GSM sections. It consists of main\"T\" runner of size 24x32x0.3x3000mm, cross\"T\" ofsize 24x32x0.3x1200mm, secondary cross\"T\" of size 24x32x0.3x600mm and PPGI wall angle of size 24x24x0.4x3000mm. The GI powder coated wall angle24x24x0.4x3000mm fixed along the perimeter of the ceiling to Walls, partitions or columns etc.,with wooden screws at 300mm centers placed at 600mmc/c. is fixed with Rawl Plug 08x45mm creating 1200mmx1200mm grid. Main-T runners 24x32x0.3x3000mm are then suspended at 1200mmc/c from ceiling using 2mm GIwire. The cross T sections of 24x32x0.3x1200 mm is interlocked between the main T at 600mm center to centert of or magrid of 1200x600mm and then secondary cross \"T\"24x32x0.3x600mm is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross Tees at the ends having length more than 600mm are to be supported independently. Finally the PVC tiles of size 595x595x8mm having PVC lamination infront side & Aluminum foil back on rareside need to be layed on the above grid frame. The PVC tile has humidity resistance RH 90%, Break strength of>160N, Fire resitance of Class AG3, 8624-1997 and NRC-0.15. Note : Colour of false ceiling shall be approved GE. (Make Diamond or Armstrong/Ramco Hilux/Saint Gobain Gyproe) |