| 1 | Demolition of cement concrete(unreinforced ) in ground floors and pavings not exceeding 15cm thickness(below ;or aboved ground level) all as specified and directed. |
| 2 | M & L For 50mm thick Cement concrete type D 2, 1:4:8 (using 40 mm gradedstone aggregate) in sub base of flooring/ hard standing. |
| 3 | M&L for Granolithic concrete 1:1:2 floor topping 25mm thick; laid over cement concrete subfloors etc. and finished to an even and fair surface complete all as specified and directed. |
| 4 | All as per item No 3 above laying granolithic topping in treads, risers, skirtings, etc. n exc 30cm in width or height complete all as specified and directed. |
| 5 | M&L for Dusting surfaces of granolithic concrete with carborundum powder complete all as specified and directed. |
| 6 | M&L for 22mm Aluminium dividing strips, 1.5mm thick, inserted in position conform to design complete all as specified and directed |
| 7 | Dismantling stone slab and tiles of any description and thickness as in floor including cement mortar bedding and rubbish off the premises complete all as specified and directed. |
| 8 | M&L 18-20mm thick machine cut kota stone slab flooringover cement screed base laid and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 9 | M& L For 18-20 mm thick ,Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platformsand like in cement screed 10 mm thick in CM 1:6 including pointing in white cement (1:2) usingmarble dust with admixture of pigment to match with shade of granite etc complete all as specified and as directed.. |
| 10 | M&L machine cut cuddappah stone slab 18-20mmthick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 11 | Rounding to edges of stone slabs , such as insteps, cooking platform, and other similar situation complete all as specified and directed. |
| 12 | M&L 75 mm thick PCC type C2 1:3:6 in plinth protection all as specified cement concrete even and smooth without using extra cement complete all as specified and directed. |
| 13 | M&L for along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron all as specified and directed. |
| 14 | M&L treatment of soil under plinth protection using emulsion @ one litre per hole, 300 mm apartincluding drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors |
| 15 | Dismantling plain or corrugated steel sheeting any gauge thickness including Nanital or similar pattern roof covering complete all as specified and directed. |
| 16 | S & F For pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed. |
| 17 | All as item no 16 above, except sheets complete all as specified and directed. |
| 18 | S & F For Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley, gutters etc. complete all as specified and directed. |
| 19 | S&F For 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with J or L hooks and washer in roof, wall etc. complete all as specified and as directed |
| 20 | S&F for1 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed)with grade of zinc coating 275. |
| 21 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc. Complete all as specified and as directed. |
| 22 | S&F Framed work such as roof trusses(framed), trusses purlins, crane gantries , rails and fastenings and heavy bracket framing(beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W(Gde E-250) Quality A complete all as specified and directed. |
| 23 | S&F steel work in tubular trusses including special washer etc., purlins, rafters, complete using ERW or induction butt welded tubes conforming to I.s 1161-1979 grade St.-240 complete all as specified and directed. |
| 24 | M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste including taking down complete all spd and dir |
| 25 | Dismantlingwall and ceiling boards (fibre, pulp, insulation boards/slabs/blankets, any thickness, including cover fillets |
| 26 | M & L for false ceiling with 4mm thick designer\"E\" board fixed on GI grid work with powder coated finish on exposed surface of size 0.6 x 0.6m consisting of GI angle supported on wall of size 24mm x 28 x 0.7mm main tee of size24mm x38mm x 0.7mm cross tee of size24mm x 28mm x 0.7 mm using purpose made members interlocking to each other and with 40mm x 3mm flat GI mild steel strip suspender made to shape at 1200mm c/c fixed with 3mm dia GI wireand making holes etc all as directedincluding two coats of white wash on ceiling after preparation of surfaces and as per manufacture instruction make of GI Grid work. |
| 27 | Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or offering credit as per schedule of credit all as directed. |
| 28 | All as per item No 27 herein before but 20mm bore |
| 29 | S&F 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors all as specified and directed. |
| 30 | All as per item No 29 herein before but 20mm bore |
| 31 | S & F in replacement table topvitreous china wash hand basin 480 mm dia including 15mm dia polythene connection, 32mm dia chromium plated (CP) waste coupling chain and plug waste filling union and32mm dia PVC waste pipe 90cm long, all necessary inlet outlet connections complete all as specified and directed. |
| 32 | S& F in replacement Brass CP long body Wash basin mixer for mixing hot & cold water screwed down for15 mm size iron pipe and fixedNote : The mixer should be of single lever |
| 33 | Preparationof new or previously untreated surfaces of iron of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including a of red oxide primer complete all as specified and directed |
| 34 | Preparationof old steel surfaces of iron of any description over 10 cm in width or girth and applying onecoats of synthetic enamel paint over and including a of red oxide primer complete all as specified and directed |
| 35 | Demolition of brick or stone/boulder masonary /pcc bloockmasonry, built in cement mortar including all quoins, aarches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 36 | M&L precast solid block masonry of block 1:3:6 type C-1 wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed. |
| 37 | Taking down cement plaster on brick or stone walls or concrete surface etc including raking out joints, hacking for key scrubbing down with water all as specified and directed. |
| 38 | M&L rendering 10 mm thick on stone masonary surfaces in CM 1:6 finished even and smoth over and including dubbing out average 10mm thickon irregular face of walls in CM 1:6 complete all as specified and directed. |
| 39 | M&L rendering 10 mm thick on stone masonary surfaces in CM 1:4 finished even and smoothover and including dubbing out average 10mm thickon irregular face of walls in CM 1:6 complete all as specified and directed. |
| 40 | M&L rendering 10 mm thick on concrete surfaces in CM 1:6 finished even and smoothcomplete all as specified and directed. |
| 41 | M&L preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over one coat primer on walls complete all as specified and directed. |
| 42 | M&L Preparation of newly plastered or unplastered surfaces on wall surfaces and applying two coats of cement base paint completeall as specified. |
| 43 | M&L complete removal of existing treatment and applying 3mm thick Birla wall care putty and applying two coat of Oil Bond distermper white or tinned over an coat of primer on walls, etc all as specified and directed. |
| 44 | All as per item No 43 above but two coat of cement base paintwithout wall care putty erc. complete all as specified and directed. |
| 45 | Taking down carefully copper/aluminium point wiring (light, fan,bell, socket or power) complete, including fixture and fittings such as switches, Ceiling rose,pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking creditand making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately. |
| 46 | Taking down ceiling fan any size or any type complete all as specified and directed. |
| 47 | Taking down old and unsrevicable Lt panel Any type and any capacitymaking good the disturbed surface all as directed specified and directed. |
| 48 | Taking down old and unsrevicablemain incoming MCB DB TPN/SPN,Industrial Socket, main switch including MCCBs/MCBs and making good the disturbed surfacecredit for above items should be made as per conditions separately. all as directed specified and directed. |
| 49 | Taking down carefully unserviceable Sub main wiring of any size and type, removing material from for taking credit and making good the disturbed surfaces of walls, ceilings etc |
| 50 | M&L for point wiring for light/fan/Bell with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick and not less than 20mm width PVC casing/capingwith all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly inclPVC Modular box surface type with PVC Modular white plate coverfor mounting fittings such as switches, sockets, fan regulators,etc complete all as specified and directed as following :- |
| 51 | (a) One light point controlled by one one way switch. |
| 52 | (b) One fan point controlled by one way switch and one regulator. |
| 53 | (c) One 3 pin switch socket outlet 6A on independent board. |
| 54 | (d) One 3 pin socket outlet 6A on same board with other switches |
| 55 | All as per item No. 49 above but with cable size 2.5 sqmm for switch socket outlet point 16 A on independent board including 2.5 FRLHS cable sqmm PVC insulated unsheathed copper earth continuity conductor as earth wire and connected to earth dolly complete all as specified and directed. |
| 56 | M&L sub main wiring with Two run single core PVC insulated unsheathed stranded copper conductor cable ofsize 4 sq mm drawn through and including heavydutyPVC conduit 25 mm or higher dia as required at site ,totally concealed in walls /floors/ceilingetc including all conduit accessories /fitting/junction box/inspection covers etc of heavy grade, ISI markedwith 4 Sqmm PVC insulated unsheathed stranded copper conductor as a continuous earth wire connected to earth dolly complete all as specified.Note : (i) Two run single core cable and one run of earth copper conductor and heavydutyPVC conduit will be measured and paid as one unit length. |
| 57 | M&L sub main wiring with four run single core PVC insulated unsheathed stranded copper conductor cable ofsize 6 sq mm drawn through and including heavydutyPVC conduit 25 mm or higher dia as required at site ,totally concealed in walls /floors/ceilingetc including all conduit accessories /fitting/junction box/inspection covers etc of heavy grade, ISI markedwith 6 Sqmm PVC insulated unsheathed stranded copper conductor as a continuous earth wire connected to earth dolly complete all as specified.Note : (i) four run single core cable and one run of earth copper conductor and heavydutyPVC conduit will be measured and paid as one unit length. |
| 58 | All as item No 53 above but the size of single core PVC insulated unsheathed stranded copper conductor cable 10sqmm.Note : (i) four run single core cable and one run of earth copper conductor and heavydutyPVC conduit will be measured and paid as one unit length. |
| 59 | S&F switch Modular, one way 6 amps, 1 module withcomplete all as specified and directed. |
| 60 | S&F switch Modular, one way 16 amps, 1 module withcomplete all as specified and directed. |
| 61 | S&F socket modular 6A, 2/3 pin combined 2 module with complete all as specified and directed. |
| 62 | S&F insocket modular 6A/16A, 2/3 pin combined 2 module with completeall as specified and directed. |
| 63 | S&F in modular fan regulator step type 120W, 2 module with complete all as specified and directed. |
| 64 | S & F ceiling rose, 3 phase PVC/polycarbonate isolated body, surface bakelite 65 x 50 mm, 3 terminal incl PVC square blockcomplete all as specified and directed. |
| 65 | Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. |
| 66 | Re-Fixing ceiling fan (M.D. supply) any size and any type, after cleaning and connecting up including provision of cable from ceiling rose or connector to fancomplete all as specified and directed. |
| 67 | Supply and fixing 24 Watt suspended architectural LED luminire provide soft -light and glare free symmetrical iiiuminationwith continuous mounting cap and suspension wire gear.complete all as specified and directed. Make Halells Cat Part no- RADIANTEDLPS24WLED840 WH1200SD. or equivalent of Bajaj/ Phillips/ Crompoton CG/Shakti/Wipro. |
| 68 | M &L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings |
| 69 | S & F LED Bulb 9 watt Make- Shakti /Wipro/ Havells/ CG and equivalent Complete all as specified and directed. |
| 70 | S & Fsheet metal enclosures MCB SPN- DB-08 way 230 V double door flush typewith 100A ratedbus bar complete all as specified and directed. |
| 71 | S & F 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single pole and neutral (SPN) with current carrying capacity of 32Amp in the MCB DB complete with connection testing and commissioningall as specified and directed. |
| 72 | S & Fsheet metal enclosures 415 Volt Triple pole and earth encolsure with a three pin and earth plug Top with socket complete with one 32Amp triple pole MCB complete all as specified and directed. |
| 73 | S & F 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity 6 to 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 74 | Supply & fix LEDfitting for Bldg security, 35 Watt230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 / 66 protection complete. including conncting with 1.5 sq mm copper condector 3 core flexible cable from fitting connector to ceiling rose and fixon wall with clamps & nut bolts and necessary GI bracket made of 32 mm light grade GI pipe of 1 mtr lenth with necessary bending complete all as specified and directed |
| 75 | M&L for earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. streep of size 25X4 mm diaby means of bolts,nuts and check nuts and washers of galvanised steel, GI pipe 15 mm dia light grade pipe for protection of GI earth lead wire both to be provided to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including PCC chamber made up of PCC 1:3:6 type C1 & RCC Chamercover of size 540x540x100 mm made with 1:2:4 Type B1 using 6 mm round MS bar & 8 mm MS bar for handle ,20 mm dia medium grade G.I. watering Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing including getting out old earthing material complete all as specified and directed. |
| 76 | M&L for Earth continuity conductor or main earthing lead25x4mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc |
| 77 | Supply , laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl using suitable clamp of cross sectional area3.5 core 35 Sqmmin and including taking out old one all as specified and directed. |
| 78 | All as per item 73 above but of the size 3.5 core 50 Sqmm |
| 79 | S&F on wall / Roof/surfacePVCwiring duct G1 of size 40 mm width and 60 mm height Cat part no -TBWDN40X60LG1 and equivalent make, suitable XLPE Cable complete all as specified and directed. |
| 80 | Supply, installation, testing and commissioning weather and vermin proof factory made CPRI approved LT feeder pillar box,indoor cubicle/KIOSK typetotally enclosed outer cage made out of 2.0 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 45 cm below ground level and 60 cm above roundsuitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.2 x 1.0 x 0.5 Mtr (approx) including connecting the following:- |
| 81 | (a) Aluminiumbus barrectangular 600 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01 job.(b)MCCB 400 Amps, 4P, 415 Volts, 50 Hz ,36 KA - 01 No ( Incoming) (c)Spreader link for Above MCCB - 01 Nos(d)Volt meter - 01 Nos(e) Ammeter - 01 Nos(f) Volt meter selector switch - 01 Nos(g) Amp meter selector switch - 01 Nos(h) CT 400/5A, Tape wounded - 03 Nos(i)RYB LED Indicator Lamp - 03 Nos |
| 82 | (j)Volt meter 0-500 Volt with selector switch(k) 6A,SP,MCB -03 NosAS OUTGOING(a) 160A 4P 25KA MCCB -07 Nos(b) Sepreader link For above MCCB - 01 Nos(c) Earth bus (d)Provision of cubicle to accommodate the above mentioned accessories.(e)Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable. |
| 83 | Supply, installation, testing and commissioning weather and vermin proof factory made CPRI approved LT feeder pillar box,indoor cubicle/KIOSK typetotally enclosed outer cage made out of 2.0 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 45 cm below ground level and 60 cm above roundsuitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.0 x 08 x 0.4 Mtr (approx) including connecting the following:- |
| 84 | (a) Aluminiumbus barrectangular 400 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01 job(b)MCCB 125 Amps, 4P, 415 Volts, 50 Hz ,25 KA - 01 No ( Incoming) (c)Spreader link for Above MCCB - 01 Nos(d)Volt meter - 01 Nos(e) Ammeter - 01 Nos(f) Volt meter selector switch - 01 Nos(g) Amp meter selector switch - 01 Nos(h) CT 125/5A, Tape wounded - 03 Nos(i)RYB LED Indicator Lamp - 03 Nos |
| 85 | (j)Volt meter with selector switch(k) 6A,SP,MCB -03 NosAS OUTGOING(a) 63A TPN 16KA-08 Nos(b) MCB SPN 63 Amp -02 Nos(c) Sepreader link For above MCCB - 08 Nos(d) Earth bus(e)Provision of cubicle to accommodate the above mentioned accessories. (f)Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable. |
| 86 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |