| 1 | Boring holes 5m deep in soil for single under reamed piles and getting out and disposal of soil to a distance of n exc 50m (dia of pile 300mm) |
| 2 | Excavation in trenches, n exc 1.5m wide and n exc 1.5 m in deep for foundation etc and getting out in soft/loose soil. |
| 3 | Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil in softloose soil.. |
| 4 | M&L PCC 1:4:8 type-D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete/ sub base of floors. |
| 5 | M&L 40mm thick damp proof course to horizontal or vertical surfaces including necessary form work in plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) complete all as specified and directed. |
| 6 | M&L for sand filling under floors or in foundations including watering and consolidation. |
| 7 | M&L for hard core of gauge n.exc 63 mm deposited, spread and levelled in layers n.exc 15 cm thick with broken bricks, watered and rammed to a true surface complete all as specified. |
| 8 | M&L 100 mm thick PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in floor, finishing cement concrete surface even and fair complete all as specified and direced. |
| 9 | M&L for Brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and direced. |
| 10 | M&L reinforced cement concrete (M-25 Design mix) (using 20 mm graded stone aggregate) in foundation, footing, foundation beams, plinth beams, bases for columns, pedestal, under reamed piles, mass concrete, etc complete. |
| 11 | M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in columns, pillars, posts, struts etc complete. |
| 12 | M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete. |
| 13 | M&L RCC reinforced cement concrete (M-25 Design mix) (20mm graded aggregate) as in beams, cantilevers, bressmummers, lintels over 1.5 m span |
| 14 | M&L Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for flat rough finished surfaces of concrete. |
| 15 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete. |
| 16 | M&L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished square, rectangular or polygonal surfaces of concrete complete all as specified and direced. |
| 17 | Form work to edges of concrete flats, treads, breaks in floors window cills, concrete railing, openings in concrete walls, floor and roofs n exc 20 cm wide and side of RCC/PCC bands in walls, horizontal or sloping and similar work complete all as specified. |
| 18 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as spd and as directed. |
| 19 | S&F Mild Steel, TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopinbg for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and direced. |
| 20 | Same as item No 20 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders. |
| 21 | M&L 15 mm thick rendering in two layers (10mm & 5mm) on fair faces of brick/concrete surfaces in cm (1:4) with WPC (WPC measured & paid separetely) finished even and smooth (Without using extra cement) complete all as spd and as directed. |
| 22 | Supply only liquid water proofing compound, ISI marked complete all as specified and direced. |
| 23 | M&L 15 mm thick rendering on fair faces of brick /concrete surfaces in cm (1:6), finished even and smooth (Without using extra cement) complete all as specified and direced. |
| 24 | M&L rendering 5mm thick in CM 1:3 on concrete surfacves/ chajja/ ceiling, etc finished even and smooth without using extra cement complete all as specified and direced. |
| 25 | Preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and direced. |
| 26 | M & L for preparation of newly plastered surfaces of wall & concrete and applying 3mm thick wall care putty including preparation complete. |
| 27 | M&L for preparation of newly platered surface of walls and applying two coat of Oil Bound Distemper of any light shade over a coat of primer complete all as specified and directed. |
| 28 | M&L for prepration of new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and direced. |
| 29 | Preparing surfaces of new wood and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and direced. |
| 30 | M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in floor/plinth protection laid in suitable panels finished even and fair all as spd. 6mm Joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 gde and three part of sand (all by weight) complete. |
| 31 | M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.18 sqm & not exceeding 0.38 sqm in floors etc set & jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) ccomplete all as specified and direced. |
| 32 | M&L for glazed ceramics coloured tiles of size 450x350x7mm thick on vertical surfaces such as skirting/dados/wall, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces over and including 10mm thick rendering in CM (1:4) complete all as specified and direced. |
| 33 | Antitermite treatment of soil under existing floors using emulsion @ one litre per hole,300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand )to match the existing floors. |
| 34 | S&F steel windows with side hung shutter incl box type butt hinges with bow handle, steel peg stay, tower bolts (each shutter having two tower bolts 100mm long) complete with glazing bars dovetailed or welded completev all as spd and as directed |
| 35 | Same as item No 34 above but without glazing bars. |
| 36 | S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165. |
| 37 | S & F of pressed steel frame of size 125 x 60mm for doors with one or more rebates complete all as specified and direced. |
| 38 | S & F 30 mm thick flush shutters solid core construction with block board core and plywood face complete all as specified and direced. |
| 39 | M&L PCC 1:3:6 type C-1 as in filling in holes of hold fasts. |
| 40 | S&F Mild steel works as in hold fasts, clamps plain angle cleats for securing purlins to wood trusses complete all as specified and direced. |
| 41 | S&F Galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and direced. |
| 42 | S&F 100 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin and fixed type B-21 complete all as specified and direced. |
| 43 | S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and direced. |
| 44 | S&F Aluminium handles, cast type, anodized 150 mm size ISI Marked complete all as specified and direced. |
| 45 | S&F aluminum alloy anodised sliding door bolts with hasp & staple & fixing clips of sheet cast extruded section & fixing bolts & sliding bolts of extruded section 300 mm long. |
| 46 | S&F floor door stopper 140 mm overall length of cover plate of aluminium alloy body and tongue, |
| 47 | Roughing surface of old concrete by picking, sweeping, cleaning & washing down with water to remove dust etc complete all as specified and direced. |
| 48 | M&L brushing neat cement slurry with 3 kg of cement per square meter complete. |
| 49 | M & L average thickness 25mm for plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) with maintaining slope of roof complete all as specified and direced. |
| 50 | M&L for 15 mm thick screed bed in CM 1:4 with water proofing compound @ 200ml /50kg of cementor as per manufacturer\"s instruction finished surface even and smooth without using extra cement including taking down of complete existing cement plaster etc complete all as specified. (Note: WPC will be measured & paid for separately). |
| 51 | M&L for water proofing treatment on non approachable/non accessible roof surface horizontal and vertical surfaces in following sequence through manufacturer/authorized applicator of the manufacturer complete all as specified and directed:- (i) Properly cleaning and drying concrete surfaces. (ii) Applying a coat of oxidized bitumen based solvent primer @ 0.3 Kg/sqm. (iii) Applying evenly tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/sqm. (iv) Laying unrolled over the bitumen coat surfaces polymeric water proofing membrane, hyperplas standard weight not less than 3 Kg/sqm with 100 mm over laps shall be sealed by flame as per manufacturer instruction. (v) Applying a coat of aluminium paint @ 100 gm/sqm over and including a coat of hot air blown grade bitumen of grade 85/25 @ 1.2 Kg/sqm duly sanded over polymeric membrane complete. NOTE:- The polymeric water proofing membrane shall be extended upto parapet walls and inserted in walls by cutting groove and making good with cement mortar 1:3 as directed. |
| 52 | S&F cabinet mirror, box type of size 19\" x 21\" of colour as approved and fixed to wall complete all as specified and direced. |
| 53 | Dismantling of floor, walls, roof tiles including cement mortar bedding but not backing and rubbish off permises complete all as specified and direced. |
| 54 | M&L for joint free non skid ceramic colouredtiles 7 to 8 mm thick(square / rectangular) area of each tile exc 0.18 sqm & not exceeding 0.38 sqm as on skirting/dadoetc set & jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and direced. |
| 55 | M&L 25 mm thick plain cement concrete (1:2:4), type B-0, using 12.50 mm graded aggregate as in floors including finishing the surface rough & even for receiving kota/tiles complete all as specified and direced. |
| 56 | M&L for machine cut kota stone slab flooring 20-25mm thick over and including 20mm thickscreed bed in cement mortar 1:6 laid and jointed with cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. |
| 57 | M&L for machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado etc laid over and including 15mm thick rendering in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete. |
| 58 | Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete. |
| 59 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level)all as specified and directed |
| 60 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for insertion of hold fast ,coping lintels ,plinth course, cills etc , incl necessary form work etc all complete. |
| 61 | Taking down cement plaster on wall/ceiling/roof etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 62 | Taking down chowkats or frame with shutters of any description (without taking off shutters from the frames) n. exc 1.5 Sqm eachall as spd. |
| 63 | Sameas item No62abovebut exc 1.5 Sqm and n.exc. 4 Sqm each. |
| 64 | S & F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkhats for doors etc complete. |
| 65 | S&F steel ventilators with top hung shutters including hinges, steel peg stay complete. |
| 66 | S&F mild steel, 150 mm long ordinary helical door spring incl roller and roller plate complete |
| 67 | S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed all as spd. |
| 68 | S&F 100 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified. |
| 69 | S&F small fitings of 2nd class hard wood door, window stops and the likenot exc 200 cucm each including MS butt hinges, medium weight, cold rolled 50mm long all as spd. |
| 70 | S&Fin repair GI wire cloth 0.56 mm nominal dia of wire and average width of aperture 1 mm and fixed with stainless steel wire staple complete all as specified. |
| 71 | S& Fin repair 18/19 mm thick Prelaminatd particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work |
| 72 | S&F 100 mm long hasp & staple aluminium anodised wire type,incl bolt to hinge plate and fixed with screw complete. |
| 73 | S&F 100 mm dia extruded brass handle, fabricated type polished fixed to board complete all as specified and directed. |
| 74 | M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete. |
| 75 | M&L for for preparation of newly plastered surfaces of ceiling and applying 2 mm thick wall care putty including preparation of new surfaces complete all as specified and directed. |
| 76 | M&L for applying 2applying two coat of oil bound distemper on ceiling over a coat of primer on prepared surfaces including rubbing with sand paper complete all as specified and directed. |
| 77 | M&L Preparing old painted surfaces of walls, chajjas etc by washing rubbing down and stopping and applying two coat of cement base paint white or tinted complete all as specified as directed. |
| 78 | M&L for Two coats of elastomeric cementatious coating Pidifin 2k of pidilite or equivalent in fosroc, sika, STP on exposed brick surface after complete removal of old plaster surface complete all as per manufacturer instructions and as directed. |
| 79 | Dismantling of Wall Panelling/ false ceiling board ,fiber insulation board any thickness including woodencover fillets/ aluminiumframe work as directed . |
| 80 | S&F Anodised aluminium snap grid frame work for false ceiling, Size of grid 605 x 605mm all as specified |
| 81 | S&F 6mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws |
| 82 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 83 | M&L for wall lining of PVC hollow sheet 5-7 mm thick consisting of 20 mm MS hollow square tubes grid and fixed with screws complete all as directed. Make- Syntex/Rajshree |
| 84 | 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on the wall to make PVC frame as per specification . |
| 85 | S/F steel work in tubular trusses incl spl shaped washer etc. Complete using ERW or induction built welded tubes confirming. |
| 86 | M&L Cutting holes into or through brick walls built in cement mortar/cement lime mortar superficial area n.exc. 150 Sqcm and making good in cement mortar (1:3) or PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate ) as required. |
| 87 | Dismantling of asbestos cement(corrugated/ semicorrugated etc)sheets in roof covering. |
| 88 | Excavation in post holes(or similar holes ) each not exc 0.5 Cum in soft/loose soil getting out, returning filing in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 89 | M&L for hollow rolled mil steel structure steel work in tabular square/ rectangular tursses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 complete all as specified and as directed. |
| 90 | M&L for pre painted galvalume sheet aluminium zinc coating GI based corrugated steel sheet with curved type 0.5mm thick on an colour having tensile strength of 550 Mpa as in roof covering / ridge/ cladding to wall fixed with self tapping screws as specified complete all as specified and directed. |
| 91 | M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete. |
| 92 | M&L for preparing old painted surfaces of walls, chajjas etc by washing rubbing down and stopping and applying two coat of cement base paint white or tinted complete all as specified and directed. |
| 93 | M&L rubber moulded coloured chequred tiles 20cm x 20cm x 20-22mm thick /30cmx30cmx25 mm thick set, jointed and pointed in neat cement slurry in floors (with grey cment and pigments) over and including 20 mm thick screed bed or bedding of cement mortar 1:6 complete al as specified and directed. |
| 94 | M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit \"medium grade\" ISI marked including all conduit accessories for concealed wiring for one light/fan/call bell / exhaust fan point controlled by one, one way switch, including concealed pressed steel terminal box of required size not less than 2.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting& making good disturbed surface & applying finishes to match existing surfacecomplete all as specified and directed. |
| 95 | Same as item No94 above but one 3/5 pin socket outlet5 amp on same board with other switches. |
| 96 | Same as item No. 94 above but socket 5 amp on independent board. |
| 97 | Same as item No. 94 above but socket out let 3/6 pin 15 Amp with 2.5 sq mm size copper conductor for power point on indipendent board. |
| 98 | S & F for switch piano, flush type, 5 amps, single pole ,one way , 230 voltcomplete all as specified and directed. |
| 99 | S & Ffor2/3 pin, 5 Amp/ 6 Amp , socket outlet, flush type, 2 in 1complete all as specified and directed. |
| 100 | S&F switch socket combination 2 in 1, 6 pin 16 Amps multipurpose type 240 volts complete all as specified and directed. |
| 101 | S&Fstepped type electronicfan regulator flush typeAC 230 volt suitable for any type of ceiling fan complete all as specified and directed. |
| 102 | Supply & Fixing ceiling rose surface backlite 65X20 mm two to three terminals complete. |
| 103 | Supply & Fixing lamp holder PVC / Ploycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 104 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 8 way. |
| 105 | S & F in replacement of MCB SPN 32 Amps240 volts, 10 KA, \"C\" curve. |
| 106 | S & F in replacement of MCB SP 5 to 32 Amps240 volts, 10 KA, \"C\" curve. |
| 107 | Supply & Fixing in replacement LED lamps 7 W |
| 108 | Supply and fixing LED lights fitting 1x 20W, 220V,AC integrated type including driver, Extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser , 4 ft,2000lm,voltage protection range 140V -270 V,NW 4000K ,,connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 109 | Supply and fixing integral LED bulkhead luminaire, 10 W, 230 Volts, IP 65 protection decorative surface mounted , complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size. |
| 110 | Supply & fix ceiling fan having copper winding motor, complete with electronic type regulator and accessories 230 V,50 Hz AC ,1200 mm sweep. BEE 5 star rated.Make Bajaj Model Elegance 1200 mm or equivalent model of make as specified and directed. |
| 111 | Supply and laying, jointing and testingXLPE insulated extrudedPVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 10 Sqmm 2 core. |
| 112 | M&L earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth wire 4 Sqmmas earthing leadsby means of bolts, nuts, check nuts and washers properly jointed as shown on drawings and including excavation, earth work.GI pipe light grade15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common saltPCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -Iand conected to earth test point including testing complete all as secified and directed. |
| 113 | Taking down existing old U/S street light fitting of any type and make & capacity complete all as specified and directed . |
| 114 | Taking down existing old us street light bracket with clamp complete all as specified and directed. |
| 115 | Takingdown existing old defectiveLTPanel / FP Box by disconnectiing its all elecetrical connections and by dismantlling foundation complete all as specified and directed. |
| 116 | Excavation in trenches n.exc. 1.5 m deep and n.exc.1.5 m wide in any type of soil and forming bottom surfaces for laying of cable/ foundation of pole scomplete all as specified and directed. |
| 117 | Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and ditected. Note: Punned down thickness of sand shall be measured for payment purposes. |
| 118 | Supply & laying bricks for protection of cable sub class \"B\"laid dry flat across the cable with width equal to the length of whole brickscomplete all as specified and ditected. |
| 119 | Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed. |
| 120 | Removal surplus soil at a distance n. exc. 50 m and deposited where diredted at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed. |
| 121 | Boring, holes for inserting of 50/80 mm bore GI pipe under the road/hard standing or any other location not less than 1200 mm deeep complete all as specified and ditected. |
| 122 | M & L GI pipe 20 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 123 | M & L GI pipe 40 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 124 | M & L GI pipe 50 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 125 | Supply, laying, jointing and testing in replacementXLPE insulated extruded PVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 16 sq mm 4 core. |
| 126 | All as per item No 13 above butsize 10 Sqmm 4 core. |
| 127 | Supply laying fixing or passing through pipe 1100 Voltage grade heavy duty cable with PVC insulated and sheathed aluminium conductor comfirming to relevent IS size 6 sqmm 2 core unarmoured and connecting to system complete all as specified and directed. |
| 128 | Supply and fix in replacement FRP , hot press moulded SMC pole box 270X225X135 mm comprising of 100 Ams aluminium bus bar 4 strips ( IP 55 protection ) with one MCB SP 6 Ams to be fixed inside the box and box will be clamped at bottom of the pole with FI clamps (duly painted ) , nut bolt washers of required size.Make - SINTEX ,Model GSJB-3126 or any other make as approved by GE. |
| 129 | S & F bracket made with GI tube light grade (not less than 1.2 RM) in length of40 mmbore size and fixed to the LT pole with the help of two Nos FI Clamps of size 50X6 mm with nut bolt and washers,complete all as specified and directed. |
| 130 | Supply and fix roadway luminaire LED light fittings of 60 watts and including necessary electric connection with 2.5 Sqmm twin core Copper conductor unarmoured cable, complete all as specified and directed. MakeBajaj /CG/Philips /Havells. |
| 131 | Same as item No.130 above but of 70 watts . |
| 132 | Same as item No. 130 above but of 90 watts . |
| 133 | Dimolation and dimantling of PCC (unreinforced) as coping of pole any description and in any position. |
| 134 | M&L for plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregateas in coping , including necessary form work complete all as specified and directed. |
| 135 | Preparation of old painted steel surface and painting of steel tubular pole upto 09 M long applying two coats of aluminium paint on complete poles including cross arms and writing of numbers on pole with black paint in 40 mm font size of letters including surface dressing all around the poles approximetely 01 Sq Mtr area complete all as specified and directed at site. |
| 136 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: Three-phase load of 12-15KW;contactor Rating 32Amps; MCB(TP) Rating 32Amps. MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs (Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. Model no NAVDEEP--54-12KW3P |
| 137 | M&L earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth strip of32X6 mmas earthing leadsby means of bolts, nuts, check nuts and washers besidebrazing at all joints as shown on drawings and including excavation, earth work.GI pipe light grade40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common saltPCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -Iand conected to earth test point including testing complete all as secified and directed. |
| 138 | Supply & Fixingsplit type air conditioner of capacity 1.5 TR 5 star rating (dual inverter) and EER 3.2. with cordless remote control unit and in built air ioniser ,plasma filter for better indoor air quality,suitable for wall mounted,single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existingafter commissioning as required at site, making necessary connectionsandM & Lfor unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer,testing of AC complete all as specified and directed. |
| 139 | Supply and fixing wall mounting voltage stabilizer for automatic operation single phase naturally air cooled indooor type and designed for input voltage between 130 volt to 280 volts with outputvoltage stabilized at 230 V +/- 2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 4 KVAcopper wound complete all as specified and directed. |
| 140 | Supply & fixing factory made,universal bracket / wall mounting stand ,made with galvanized structural steel,high strenth,weather proof,powder coated,modular construction and not less than 5 Kg and suitable for 1.5 TR capacity split type AC. |
| 141 | M & L for power/sub main wiring with two runs of single core 4.0 sqmm size and one run of single core 4.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed.( Note - two runs of 4.0 Sqmm single core copper conductor and one runs of 4.0 Sq mm copper conductor shall be measured as one unit length.) |
| 142 | Supply & fixing earth plug enclosure (plug and socket ) with and including one single pole MCB, 20 Amps. |