| 1 | Dismantling of asbestos cement corrugated or semicorrugated /fibre sheets in roof covering complete all as specified and directed by Engr-in-charge complete all as specified and as directed. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws completeall as specified and as directed by engineer-in-charge.(Make-JSW(Pragati+AZ70),Tata Blue) |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscompleteall as specified and as directed by engineer-in-charge.(Make- JSW(Pragati+AZ70),Tata Blue) |
| 4 | Demolition of brick work built in cement mortarincluding all quoins arches, pillars etc but including ashalr facing dressed stone work and precast concrete articles complete all as specified and as directed |
| 5 | Demolition of cement conc (un reinf) in ground floor and pavings not exceeding 15 cm thick above or below ground level complete all as specified and as directed |
| 6 | Taking down cement or cement lime plaster of any description on brick or stone walls, etcincl raking out joints hacking for keys srubbing down with water etc complete all as specified and as directed |
| 7 | Taking down chowkats or frames with Shutters( without taking off the shutter from the frame ) of area n.exc 1.50 Sqm each and removing from site complete all as specified and as directed |
| 8 | Taking down chowkats or frames with Shutters( without taking off the shutter from the frame ) of area exc 1.50 Sqm but n.exc 4.00 Sqm & removing from site complete all as specified and as directed |
| 9 | M&L brick work , with sub class \"B\" bricks built in cement mortar 1:6 straight or curved on plan exc 6mtr mean radius, using old size bricks complete all as specified |
| 10 | Material and labour for rendering 15 mm thick on fair face of brick work or concrete surfaces in cement mortar 1:4 and finishing the surfaces even and fair mixed with liquid water proofing compound as per manufacturer\"s instruction complete all as specified and directed. Note: Water proofing compound shall be measured & paid separately. |
| 11 | Material and labour for rendering 10 mm thick on internal surface of brick work or concrete surfaces in cement mortar 1:6 and finishing the surfaces even and fair without using extra cement complete all as specified and directed. |
| 12 | S&F Door closer hydraulically regulated, designation No. 3, universal type,aluminium extruded section suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site. |
| 14 | M&L 18-20 mm th machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, over 20 mm th screed or bedding layer in CM 1:6 complete all as specified and directed by Engineer-in Charge. |
| 15 | All as per itemabove but as in skirting over 10mm th rendering in CM 1:4 complete all as specified and directed by Engineer-in Charge. |
| 16 | S&F anodised aluminium framepowder coated with minimum thickness of powder coating 50 micron for doors, windows, ventilatorswith one or more rebates including joining cleat for fixing, hinges etc. complete all as specified. complete all as specified and directed. Note:- Prelaminated partical board and sheet glass/wiremesh shall be measured and paid for separately. Make:- INDAL/HINDALCO/JINDAL or equivalent as per IS. |
| 17 | S&F anodised aluminium door shutters, powder coated aluminium section weighing 0.55 Kg/m ncluding necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, 2 Nos tower bolt of size 200 mm, hinges, anodised aluminum snap beading screws etc with chowkhat complete all as specified. |
| 18 | S & F for Anodised aluminium window and ventilator shutters,Powder Coating (minimum thickness of powder coating 50 micron) side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats,hook and eye closure,Each door having 02 Nos D type handles, 02 Nos aluminium tower bolts 300 mm size, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 19 | S&F 5.5 mm thick sheet glass selected quality and glazing with oil putty in squares n exc. 0.5 Sqm in each pane with solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, complete all as specified and as directed |
| 20 | S&F 5.5 mm thick sheet glass selected quality and glazing with oil putty in squares exc. 0.5 Sqm in each pane with solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, complete all as specified and as directed |
| 21 | S&Fgalvanized mild steel wire cloth 0.56mm dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staple complete all as specified and as directed by engineer-in-charge. |
| 22 | S&F 9 mm th Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame workcomplete all as specified and as directed by engineer-in-charge. |
| 23 | M&L PCC1:4:8 type D-2using 40 mm graded stone agg as in mass filling and sub base. |
| 24 | M&L preparing surfaces ofnewwalls and applying two coats of oil bound distemper over a coat of primercomplete all as specified |
| 25 | M&L preparing surfaces new of walls and applying two caots of cement base paint over a coat of primercomplete all as specified incl preparation of surfaces. |
| 26 | M&L for 300X300X 25 mm th chequered cement concrete tiles coloured with grey cement andpigmentas in floor etc over 20mm th screedbed in CM 1:6 complete all as specified and directed by Engineer-in Charge. |
| 27 | M&L for 75 mm th cement conctype C-2, 1:3:6 as in plinth protectionwith using 40mm graded stone aggregate etc all as specified. |
| 28 | Dismantling wall andCeiling boards any thickness, including cover fillets complete all as specified and as directed. |
| 29 | M&L for 12mm thick perforated particle board/tiles for insulation and accoustic purpose 60X60CM in size fixedin frame work /grid complete all as specified and as directed |
| 30 | M & L forGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed by Engineer-in-Charge. |
| 31 | Taking down carefully surface aluminium or copper point wiring onTW Batten/in conduit/ with PVC casing-caping/conduit(light, fan, socket, or power) complete and making good the disturbed surface of wall/celling etc including taking down fitting such asswitches, ceiling roses, pendants, regulators, sockets, light fittings etc and removing material from site and taking credit as per schedule of credit complete all as specified. |
| 32 | M & L for concealed Point wiring complete with 1.5 Sqmm (nominal area)1100 volts grade single core PVC insulated FR-LSH multistranded copper conductor cable in and including medium grade duty PVC conduit not less than 20 mm(wall thickness 1.5 mm ) including fitting & accessories, with sunken galvanized pressed steel terminal boxes with 3 mm thick laminated baklite (Hylum/Anchor) sheet top cover for mounting switch, socket etc for one light/fan/bell point controled by one switch and(Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm. stranded copper conductor with green FRLSH PVC insulating earth common earth dolly, complete all as specified. |
| 33 | All as per above item Serial No.2 One socket outlet 6 amp controlled by one switch on the same board with other switches |
| 34 | All as per above item Serial No. 2 One socket outlet 6 amp controlled by one switch on indepdendent board |
| 35 | All as above item No 02 but M & L Point wiring with 1100 volts grade single core PVC insulated FRLSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm diaISI marked with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for one 16 amp socket outlet controlled by one switch on independent board complete. |
| 36 | S & F switch piano flush button single pole one way 5/6 amp complete. |
| 37 | S & F switch piano flush button single pole one way 16 amp complete. |
| 38 | S & F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete. |
| 39 | S & F socket outlet2 in 1, 3 pin16 amp flush type complete. |
| 40 | Supply and fixing of LED lights fitting 1 x 20 W, 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complect as specifiedMake : Havells/ Crompton / Bajaj/Philips/ Orient Electric |
| 41 | S & F ceiling rose65x50mm 3 terminals polycarbonate body complete. |
| 42 | Supply and fixing fan regulator electronic step type and making connection complete all as specified and as directed. |
| 43 | S & F for MCB DB SPN 8 waydouble door IP 43 complete prewired including Bus Bar with earth bar and neutral bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed .Make: Legrand/Havells/Indoasian /Siemens/Schneider |
| 44 | Supply and fixing MCB\"s single pole and neutral 32 Amps, 240 Volts,10 KA rapturing capacity \"B\" curve.complete all as specified & directed. Make :Legrand/Havells/Indoasian /Schneider/L&T |
| 45 | Supply and fixing MCB\"s single pole 6 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity \"B\" curve.complete all as specified & directed. Make :Legrand/Havells/Indoasian /Schneider/L&T |
| 46 | Earthing completewith galvanised steel earth plate electrode 60x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate no. 3 connected to earthing test point all as specified or indicated including testing on complection., earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around includingtop and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm (top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregatewith 1 nos MS handles of 8mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2020) testing on completion complete all as specified. |
| 47 | S&F repair ,40 mm bore GI tubing \"light garde \"in trenches on pole for protection of cables complete all as specified & directed by Enginner-in Charge . |
| 48 | Supply ,laying and testing cable XLPE insulated ,PVC sheathed ,PVC bedded ,galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 16 sq mm 2 corewhile taking down the old cable complete all as specified and directed by engr in charge. |
| 49 | Excavation in trenches in Soft/disntegrated not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of GI pipe etc or soil for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in Soft/loose of soil complete all as specified & directed by Engr-in-Charge. |
| 50 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/loose soil, all as specified & directed by Engr-in-Charge. |
| 51 | Removing excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point soft /loose soil all as directedby Engr-in-Charge. |
| 52 | M&L for sand cushioning with 8 cm sand beneath the cable and 15 cm above the under ground cable below the sand and gently punning the sand above the cable upto10 cm to cushioning to cable complete all as directed by Enginner-in-charge .(Note : The payment will be made for the 18 cm ) |
| 53 | Supply and fix common burnt clay building brick Sub class B designation75 and laying it perpendicular along the length of the cable all as specified and directed. |