Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface dressing n exc 15 cm deep getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose of soil complete all as specified and directed. |
| 3 | Excavation in trenches, n exc 1.5 m wide and exc 1.5 m but n exc 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m but n exc 3.00 m in depth and getting out in soft/ loose of soil complete all as specified and directed. |
| 4 | M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 5 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed. |
| 6 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all specified and directed. |
| 7 | M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 8 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 9 | M&L PCC (1:4:8) type D-2 in foundation filling and mass concrete complete all as specified and directed. |
| 10 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 11 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified and directed. |
| 12 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for Columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 13 | Formwork to sides of pillars, posts, struts, piers, columns and stanchion square, rectangular on plan or polygonal etc complete all as specified and directed.. |
| 14 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for beams, cantilevers, bressummers, lintels, lintel beam, roof beams etc complete all as specified and directed. |
| 15 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams etc complete all as specified and directed.. |
| 16 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed. |
| 17 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc complete all as specified and directed.. |
| 18 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, thick etc complete all as specified and directed. |
| 19 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for chajja, sun shed etc complete all as specified and directed. |
| 20 | Formwork to chullah hoods, chajjas, troughs and similar items including edge etc complete all as specified and directed. |
| 21 | M/L 100mm thick PCC (1:4:8)type D2 (using 40 mm graded stone aggregate) as in sub base of floors etc complete all as specified and directed. |
| 22 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 23 | M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and bindersincluding mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. complete all as specified and directed. |
| 24 | M&L coloured Non - Skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.. |
| 25 | M&L coloured Glazed ceramic tiles in vertical surface 300x 450 x 7 mm thick on vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. |
| 26 | M&L Vitrified Ceramic tiles 10 mm thick light shed (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 27 | All as per item no 26 here-in before but on vertical surface as in skirting/ dado etc complete all as specified and directed. |
| 28 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stonefor window window cills in one piece including 15 mm thick screed bed in CM (1:6) etc complete all as specified and directed. |
| 29 | M&L Brickwork with sub- class ‘B’ bricksstraight or curved on plan exc 6 m mean radius built in cement mortar(1:6) complete all as specified and directed. |
| 30 | M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar(1:4) complete all as specified and directed. |
| 31 | M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) on wall using with liquid water proofing compound@ 200 ml/50 kg per bag of cement or as per manufacturer instruction finishing the surfaces even and smooth without using extra cement complete all as specified and directed.. NOTE : Water proofing liquid will be measured and paid separately. |
| 32 | M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 33 | M & L for rendering 5 mm thick on fair faces of bricks/concrete surface in cement mortar (1:3) on RCC surfaces, celings, sides of beams, columns finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 34 | M&L Rendering 10 mm thick in cement mortar 1:4 on concrete surfaces for WPT with liquid water proofing compound@ 200 ml/50 kg per bag of cement or as per manufacturer instruction finished even and smoothwithout using extra cement over roof / sunken slab /wall complete all as specified and directedNOTE : water proofing liquid will be measured and paid separately complete all as specified and directed. |
| 35 | M&L for Water proofing treatment on \"Non approachable / non accessible roof\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer all as specified and directed complete(i)Applying approved bituminous based primer conforming to IS : 3384-1995 @ 0.3kg/Sqm to be applied on top surface of prepared surface till the surface is properly impregnated.(ii) Laying APP (Atactic polypropylenePolymer Modified pre fabricated membrane) water proofing membrane of weight not less than 3 kg/sqm with minimum 100mm side overlap along the length from downward to upward completely sealed with torch application/hot blown lamps.(iii)Applying two cots of bituminous based aluminium paint @ 0.3kg/Sqm complete all as specified and as directed. |
| 36 | Supply only water proofing compound (liquid), ISI marked complete all as specified and directed. |
| 37 | Material and labour for preparation of new plastered surfaces of wall and applying two coats of Birla white wall care putty, JK wall care putty or equivalentto make entire surface free from undulationsall as specified & directed. |
| 38 | M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified & directed. |
| 39 | M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed. |
| 40 | M&L for preparation of new plastered surfaces of wall and applying two coats of anti fungal (Appex) painting over a coat of alkali resistant primer complete all as specified & directed. |
| 41 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 42 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 43 | M & L for 75 mm thick PCC 1:3:6 type C-1 using 40mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge all as specified and directed. Note: 10mmwideand 75mm deep joints shall be made at 3 mtr interval andat each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3 complete all as specified and directed. |
| 44 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 45 | M/L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 46 | M/L 25 mm thick PCC (1:2:4)type B0 (using 12.5 mm graded stone aggregate) as in sub floor of floors etc complete all as specified and directed. |
| 47 | S&F powder coated Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified. |
| 48 | S&F powder coated aluminium Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 49 | S&F powder coated aluminium Anodised aluminium door shutters ready to receive wire mesh/glass, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed. |
| 50 | Supply & Fixing in repair 4.8 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with beads in square exc. 0.5 sqm in each pane complete all as specified and directed. |
| 51 | S&Faluminium sheet powder coated of thickness not less than 5mm thick to be in sealed as panel in aluminium door including fixingcomplete all as specified and directed. |
| 52 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made . |
| 53 | Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance indimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 54 | M&L Anodised aluminium grills DG-104 powder Coating(minimum thickness of powder coating 50 micron) to, windows, ventilatorsincluding necessary channels, screws etc. complete all as specified and as directed. |
| 55 | S&F Aluminium anodised barrel tower bolt extruded section and fixed of size 150 mm complete all as specified and directed. |
| 56 | S & F SS butt hinges 100 mm medium weight colled rolled fixed complete all as specified and directed |
| 57 | M&L for aluminium 300 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or aluminium alloy and fixed complete all as specified and directed. |
| 58 | S & F 150mm long aluminium handles cast type, anodised complete all as specified and as directed |
| 59 | M & L preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 60 | M & L Sheet glass 4.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 61 | M & L figured glass, pin headed 4.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 62 | S & F One piece floor mounted Vitreous China EWC (Corium 220 size 690x390x770mm) of Make Cera with integrated Flushing Cistern, Soft closing seat cover and necessary Nut/Bolts for fixing or equivalent all as specified and directed by Engineer in Charge |
| 63 | S&F countertop wash basin white 460mmx460mm size and round square with vanity complete all as specified and directed |
| 64 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commercial plywood & aluminium angle frame and fixed to wooden plugs with chromium plated brass screws washers complete all as specified and directed. |
| 65 | S&F PVC (SWR) floor trap 75mm , plain with CP grating including jointing with solvent cement complete all as specified and directed. |
| 66 | S&F 450mm long PVC connection of approved quality with brass check nuts at both ends for 15mm bore pipe complete all as specified and directed. |
| 67 | S&F PVC(SWR) bends for 110mm dia PVC pipes with rubber ring joints complete all as specified and directed |
| 68 | S&F PVC (SWR) pipes 110 mmsingle socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 69 | S&F PVC (SWR) pipes 110 mmsingle socketed inany length withrubber ring joints fixed to wall complete all as specified and directed. |
| 70 | S&F PVC (SWR) pipes75 mm single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 71 | S&F PVC bends for 75 mm bore complete all as specified and directed. |
| 72 | S&F PVC (SWR) 110 mm bore junction single, (Single T) equal or unequal complete all as specified and directed. |
| 73 | S&F PVC (SWR) 75 mm bore junction single, (Single T) equal or unequal complete all as specified and directed. |
| 74 | S&F PVC (SWR) vent cowl 110 mm bore complete all as specified and directed. |
| 75 | S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and directed. |
| 76 | S&F Rotational moulded polythene water storage tanks, double layered (Cylindrical vertical with closed top) of capacity 1000 lit, hoisted and fixed in position as in repair complete all as specified. |
| 77 | S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s .and fixed to dia of pipe 20mm as in repairs, complete all as specified and directed. |
| 78 | S&F Stop valve cast copper alloy 20 mm screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe of bore 20mm fixed as in repairs complete all as specified and directed. |
| 79 | S&F Angle stop cock fancy type, brass chromium plated with CP wall cap 15 mm bore after taking down of old brass stop valve complete all as specified. |
| 80 | S&F Bib tap cast copper alloy chromium plated, fancy type, with capstain head handle screwed down screwed for iron pipe and fixed to 15mm bore pipe after taking down of old brass bib tap complete all as specified. |
| 81 | S&F Steel water tubing medium grade 15mm bore galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 82 | S&F20mm bore medium grade galvanized steel tubes with all fittings and fixed to wall and celing or laid in floors etc complete all as specified and directed. |
| 83 | M&L for cutting chasis, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing and making good cutting not exc 10cm girth complete all as specified and directed |
| 84 | S&FCP towel rail 600 mm long fixed with and including chromium plated brass screws and wooden / plastic cleats complete all as specified and directed. |
| 85 | S&FSalt-glazed stoneware gully traps, square or round mouthed, tvpe \"P\" size of gully trap 150x150mm complete all as specified and directed. |
| 86 | S&Fglass shelf with CP railings 600 mm long fixed with and including chromium plated brass screws and wooden / plastic cleats complete all as specified and directed. |
| 87 | S&Ftoilet paper holder with flat recessed type stainless steel complete all as specified and directed. |
| 88 | S&F Vitreous China Urinal, Half stall type, white including, flush pipe and waste pipe. Complete all as specified and directed. |
| 89 | M&L for Damp proof course 25 mm thick in cement concrete with WPC 1:2:4 to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. |
| 90 | M&L for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m complete all as specified and directed |
| 91 | M&L for Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m complete all as specified and directed |
| 92 | Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising ofPVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 93 | Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thickcomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 94 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steelwire staples. |
| 95 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 96 | S&F 15mm dia Pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed |
| 97 | M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, benching of manholes, lightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 98 | Excavating in post holes (or similar holes) in hard dense soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed |
| 99 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed |
| 100 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed |
| 101 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed |
| 102 | S & F in repair 20mm Dia Aluminium alloy anodised curtain rod decorative fancy type with brackets complete all as specified. |
| 103 | Removing Excavated soil exceeding 250 M but not exceeding 500M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 104 | Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigmentconfirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and directed. |
| 105 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth, in hard/dense soil and getting out for foundation etc. complete all as specified and directed. |
| 106 | PCC 1:3:6 type C-2 using 40mm graded stone aggregate) as in foundation & mass concrete bed of manhole etc. complete all as specified and directed. |
| 107 | Brick work with sub class \"B\" bricks straight or curved on plan, exe 6.0M mean radius built in cement mortar 1:4 as in wall of manholes complete all as specified and directed. |
| 108 | M & L forPCC 1:3:6 type C-1 using 20mm graded stone aggregate) as in coping etc. including necessary form work complete all as specified and directed. |
| 109 | S&F for PVC (SWR) pipe of 150 mm internal dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 110 | M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate) as in bed of drain pipes, laid to falls including packing under, haunching against the sides of pipes after they are laid, jointed and tested for 150mm bore pipe complete all as specified and directed. |
| 111 | M & L forRCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in precast cement concrete, manhole covers including all use of forms, moulds or machine moulds and setting the blocks, slabs etc in cement mortar 1:4,complete all as specified and directed. (Reinforcement shall be measured and paid separately under respective item of schedule \"A\") |
| 112 | M&L Septic Tank, excavation in hard/dense soil, foundation in PCC 1:2:4 type B-2 brick work in CM 1:4, including RCC 1:2:4 type B-1 partition wall and RCC slab covers including RCC precast manhole cover having 6mm plate embedded all round/ fiber reinforced cover with angle iron frame, vent shaft and sludge chamber etc complete for 10 users complete all as specified and directed and shown on drawing No TD -217 sheet 1/7 to 7/7. |
| 113 | M&L for Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 m dia X 3.00m of effective depth 3.00 mtr complete all as specified and shown on drawing No TD - 309 sheet 1/4 TO 4/4. |
| 114 | Supply & Fixing point wiring for one light point/ fan (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS)PVC cable drawn into & including medium grade PVC conduit (not less than 20mmouter dia ) with all fittings and accessories fixed concealed(including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) andsunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washersincluding one continuous run of PVC insulated (green colour) 1.5 Sqmm multistrandedcopper conductor cable earth wire and connected to earth dolly complete all as specified and directed Note:- wiring shall be done in colour coding as directed by Engineer in charge. |
| 115 | All as per item No.114 here-in-before but one socket outlet 5 Amps on the same board. |
| 116 | All as per item No.114 here-in-before butone 3 pin socket outlet 5 Amps independent. |
| 117 | All as per item No.114 here-in-before butone bell point controlled by one bell push switch. |
| 118 | All as per item No. 114 here-in-before but with 2.5 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 5/15 Amps socket. |
| 119 | All as per item No. 114 here-in-before but with 4 Sq mm two single core and 4 Sq mm one single core as earth wire for AC Point. |
| 120 | S&F ceiling rose surface bakelite3 terminal with base plate complete all as specified and directed. |
| 121 | Supply & Fixing lamp holder (dome type) PVC insulated body with cord grip cap for angle/battern fitting complete all as specified and directed. |
| 122 | Supply & fixing BellAC 230 volts, 50 Hz single pole complete all as specified and directed. |
| 123 | Supply and fixing of following rating of modular type ,white polycarbonate, switches, sockets, fan regulator suitable for250V, AC, 50Hz.Electrical supplyand as directed by Engr-in-Charge. |
| 124 | (a) 6 Amp one way switch |
| 125 | (b) 6 Amp 2/3 Pin combined socket shuttered |
| 126 | (c) Modular Switch 1 way 16 Amp, 1 Module |
| 127 | (d) Modular Switch socket combination 16Amp, 6 Pin, 3 Module |
| 128 | (e) Stepped type electronic fan regulator modular, 120W-2 module |
| 129 | (f)6 Ampbell push switch modular type |
| 130 | Supply and fixing of following sizes of modular front plates, white with frame on existing boxes complete as required. |
| 131 | (a) 2 Module |
| 132 | (b) 3 Module |
| 133 | (c) 4 Module |
| 134 | (b) 6 Module |
| 135 | (c) 8 Module |
| 136 | Supply and fixing anodised rust proof 18 SWG MS box, flush type offollowing sizes (to be of same make as modular switches and sockets)to berecessed in wall/gypsum partition complete as required :- |
| 137 | (a) 75mm x 105mm x 50mm deep (1-2 Module) |
| 138 | (b) 75mm x 105mm x 50mm deep (3 Module) |
| 139 | (c) 75mm x 105mm x 50mm deep (4 Module) |
| 140 | (d) 75mm x 210mm x 50mm deep (6-8 Module) |
| 141 | Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive ofjunction/terminal boxes, all fittings and accessories fixed concealed with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DBincluding cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existingold sub main wiring complete all as specified.Note :1 The cost of earth wire is included in the quoted rates. 2.Two run of 6 sqmm, one run of 6 sqmm and one run of PVC conduit will be measured as one unit ie one running metre” |
| 142 | Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type(warm/milky white as required on site) with high efficiency PMMAdiffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make Havells/Phillips/Bajaj/C&S Note:- Contractor shall submit 2 year warrantee of material from manufacturer alongwith purchase voucher. |
| 143 | Supply and fixing LED lights fitting 1x 20W (warm/milky white as required on site), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and life of tube light not less than 50,000 hours.completeall as specified and directed..Make Havells cat pat LUMILINEBS20WLED865SPCWH or equivalent of phillips/wippro/Bajaj/Surya complete Note:- LED tube light shall be purches to get minimum 2 year warrantee of material from manufacturer. |
| 144 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper cable of suitable size complete |
| 145 | Supply & Fixingsheet metal enclosure for DBs(double door type)single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 146 | Supply & Fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 40 TO 63 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 147 | Supply & Fixing 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of single pole 5 to 32 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 148 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge. |
| 149 | S&F sheet metal enclosure with socket plug top and MCB single pole and netural enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp 240 Volts complete all as specified and directed. |
| 150 | S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells cat pat HEXAFT10WLED857SSYMBOPC or equivalent cat part in makephillips/wippro/Bajaj & C&S .Note:- Contractor shall submit 2 year warrentee of material from manufracturer alongwith purchase voucher. |
| 151 | S & F exhaust fan made of sturdy Engineering plastic type ISI Mark, copper winding of sweep 300 mm size completewithlouvers including cutting opening through brick/stone /PCC block wall, making of holes and grouting of suitable size of nuts and bolts for 300 mm exhaust fan and making good dismantled portion and making connection with wire of suitable size and connecting accessories complete all as specified and directed. |
| 152 | M&L for earthing complete with galvanized sheet earth plate electrodes 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanized Iron/ steel of size 75x75x25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed. |
| 153 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross section area 16 Sqmm 2core laid in trenches or passing through pipes/ducts and incl the disturbance surface of road making good with using PCC complete all as specified and directed. Including taking down old LT U/G Cable from trenches/protection pipe etc complete. |
| 154 | M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed.. Note :-Thickness of sand cushioning shall be measured after punning. |
| 155 | M&L for brick sub class \"B\" for protection of cable comlete all as specified and directed. |
| 156 | Supply and Fixing steel tube Light grade galvanised 50 mm bore with all fittings for protection of UG cable under road/culvert and fixing on wall with saddle, screw complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail