| 1 | Surface dressing not exceeding 15 cm deep and getting outin soft/loose soil complete all as specified and directed. |
| 2 | Excavation in trenches n.exc 1.50m wide and n exc 1.5m depth for foundation etc or for shafts, wells, etc and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Description all as per ser item No 02 above but for each additional 1.50m or part thereof in depth beyond the first 1.50m and getting out in Hard/Dense soil complete all as specified and directed. |
| 4 | M&L for cement concrete 1:4:8 type D-2 (40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed. |
| 5 | M&L formwork for sides of concrete foundations, footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 6 | M&L formwork for sides of columns etc and similar work; vertical or to batter complete all as specified and directed. |
| 7 | M&L for formwork to sides and soffits of floor or roof beam, beam hauchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc complete all as specified and directed. |
| 8 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 9 | Description all as per ser item No 08 above but 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders. |
| 10 | M & L 40mm thick Damp proof course to horizontal or vertical surfaces in cement mortar 1:2:4 Type B-0 including necessary formwork |
| 11 | M & L applying evenly a coat of blow type bitumen at the rate of 1.50kg per square metre and blinding with clean dry sand @ 0.05 cu.m per sq. m complete all as specified and directed. |
| 12 | M&L for RCC (design mix) M-30 (20mm graded aggregate) in foundation, including rafts, footing, foundation beams, plinth beams; bases for columns, etc.; basement slabs, underreamed piles and mass concrete complete all as specified and directed. |
| 13 | M&L for RCC (design mix) M-30 (20mm graded aggregate) in Columns complete all as specified and directed. |
| 14 | M&L for RCC (design mix) M-30 (20mm graded aggregate) in beams, cantilevers, bressummers, linlets over 1.5m span complete all as specified and directed. |
| 15 | M&L forRCC (design mix) M-30, Type B1 by using 20 mm graded stone aggregate in slabs supported on walls, in septic tank , soakage well ,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 16 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 mtr mean radious built in CM 1:4 complete all as specified and directed. |
| 17 | M&L brick work with sub class \"B\" brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 18 | M&L for brick work with sub class \"B\" bricks in one brick thick honey comb walling built in CM 1:4 complete all as specified and directed. |
| 19 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6 mtr mean radius old bricks laid dry for brick bats, complete all as specified and directed by Engr-in-charge. |
| 20 | Returning filling incl spreading leveling watering and well rammings in layers n exc 25cm complete all as specified and directed. |
| 21 | Removal of surplus soil n exc 50m and depositing where dirtected at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 22 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates FE 410 W (Gde- E- 250) quality- A. |
| 23 | M & L compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, etc.FE 410 W (Gde- E- 250) quality- A. |
| 24 | S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe 410 -W (Gde- E- 250) quality- A, complete all as spd and directed. |
| 25 | M & L for new steel Surfaces of any description, not otherwise descri-bed, over 10cm width or girth of applying Two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 26 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of an colour having tensile strength of 550 Mpa asinroofcovering/cladding to wall, fixed with self tapping screws as specified |
| 27 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 28 | M&L for glazed ceramic coloured tile for vertical surfaces of size 300x200x6mm thick , set and jointed in neat cement slurry and pointed in white or colour cement to matched including 10mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 29 | Moorum / Red Bajari filling in floor or pavings, laid in layers n. exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 30 | M&L for hardcore of gauge broken stone or boulder n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 31 | M&L for 75mm PCC 1:4:8 type D2 (40mm graded aggregate) as in sub base complete all as specified and directed. |
| 32 | M&L for 25mm PCC 1:2:4 type B0 (12.5mm graded aggregate) as in floor complete all as specified and directed. |
| 33 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 34 | M&L for Rendering 10mm thick on fare faces of brick work or concerete surfacec in CM 1:6, finish even and smooth without using extra cement complete all as specified and directed. |
| 35 | M&L for Rendering 10mm thick on fare faces of brick work or concerete surfacec in CM 1:4, finish even and smooth without using extra cement complete all as specified and directed. |
| 36 | S&F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed. |
| 37 | S&F for sheet glass 3mm thick ordinary quality and glazing with oil putty/beads in square n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 38 | S&F for solid PVC solid door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, in opening as per specification & drawing complete all as specified and directed. |
| 39 | S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom raols. M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail: panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed. |
| 40 | M&L 16mm outer dia for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as pecified and directed. |
| 41 | M&L 20mm outer dia for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as pecified and directed. |
| 42 | M&L for vitreous China squatting pan, `Orissa\" pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and directed (Make : Hindware or equivalent) |
| 43 | M&L for PVC valveless, syphonic action type, flushing cistern, 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets and including flushing pipe 32 mm dia of bore, high density polyethylene pipes of pressure rating 6 kg/sqcm complete all as specified and directed |
| 44 | S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed |
| 45 | M&L for 15mm dia of bore stop valves, fancy type, chromium plated, screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed. |
| 46 | M&L for 110mm PVC (SWR) pipes, single socketed, in any length, with rubber rings joints, laid in trenches or in floors completed all as specified and directed |
| 47 | M&L for 75mm PVC (SWR) pipes, single socketed, in any length, with rubber rings joints, laid in trenches or in floors completed all as specified and directed |
| 48 | M&L for 75mm dia of bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed |
| 49 | M&L for 110mm PVC (SWR) bends any radius complete all as specified and directed |
| 50 | M&L for 110mm dia PVC (SWR) vent cowl complete all as specified and directed |
| 51 | M&L for 110mm dia of bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed |
| 52 | M&L for 75mm dia of bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed |
| 53 | M&L for 20mm dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 54 | S&F grating doom 100mm diaof PTMT (Minimum weight 25 gms) complete all as specified and directed. |
| 55 | S&F 1000 litre capacity, double layered rotational moulded polythylene water storage tanks ISI marked (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed by Engineer-in-Charge. |
| 56 | M&L for preparation of new plastered surface and applying two coat of cement base paint externally complete all as specified and directed. |
| 57 | M&L for preparation of new plastered surface and applying two coat of distemper oil emulsion OBD white or tinted in wall internally complete all as specified and directed. |
| 58 | M & Lanodised aluminium snap grid frame work size of grid 605 x 605mm for false ceiling all as specified and directed. |
| 59 | M & L for providing and fixing gpsum board 12mm thick in ceiling fixed with screw as per manufactures instructionscomplete all as specified and directed |
| 60 | S&F in repair fancy type long shank bib taps cast copper alloy chromium plated with crutch or butter fly handle screwed down screwed for iron pipe 15mm bore complete alll as specified and directed. |
| 61 | S&F 150mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 62 | S&F 100mm long Extruded aluminium alloy handles, fabricated type., anodised complete all as specified and directed. |
| 63 | M&L for 100mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed |
| 64 | S&F grating doom 100mm diaof PTMT (Minimum weight 25 gms) complete all as specified and directed. |
| 65 | M & L for 100mm thick cement concrete type C2 (1:3:6) (using 40mm graded aggregate) |
| 66 | M & L for 50mm thick sand filling under floors or in foundation incl watering and consolidation |
| 67 | M & L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and directed. |
| 68 | Providing, cement concreteTyoe B-1 using 20mm graded aggregate (1:2:4)in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not providedfor in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 69 | M&Lfor 75 mm thickPCC 1:3:6 type C2 using 40 mm graded stone aggregate as inplinth protection/foot path etc. |
| 70 | Cutting chases, pinning in brickwork and making good to facings where required and pointing in cement mortor 1:3 to enda or edges of landings, steps, cillis, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc.. and making good, cutting not exc 10cm girth complete all as specified and as directed. |
| 71 | M&L for Lagging to pipes used in internal water supply or plumbing all around with, 25mm thick bonded mineral wool pre-formed mineral wool pre-formed \"SNAP ON\" pipe sections of density 144 kg/cum confirming to IS 9842 on pipe of internal dia 20mm complete all as specified and as directed. |
| 72 | M&L for 15 mm thick cement plaster in cement mortar 1:4 on bricks or concrete suface and finished even and smooth without using extra cement all as specified and directed. |
| 73 | Preparing new plastered surface of walls and appyling three coats of white wash all as specified and directed. |
| 74 | M&L for Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection 50mm thick, finished even ans smooth without using extra cement all as specified and directed. |
| 75 | S&F structural steel works as in roof trusses, purlings crane gantires, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) incl distance pieces, cleants plate etc complete all as specified and directed. |
| 76 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed by the Engineer-in-Charge |
| 77 | Supply only chain link MS galvanisd fencing, any size or type complete all as specified and as directed by the Engineer-in-Charge |
| 78 | Material & labour for point wiring complete with singlecore 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLSH)drawn through and including PVC surface conduit 19/20 mm bore (ISI marked) and accessories , terminated in and including pressed steel terminal boxes with plastic laminated backlite sheet top cover 3 mm thick (hylum)fixed with nickel polished screws with washers, earth continuity PVC cable(FRLSH), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly for One light point/Fan poink/Exhaust fan controlled by one way switch 5 Amps complete all as specified and directed complete all as specified. |
| 79 | Description all as per ser item No 78 above but socket out let 3 pin, 5 Amp on independent board. |
| 80 | Description all as per ser item No 78 above but with 2.5 sqmm copper conductor cable for socket out let 3 pin, 15 Amp on independent board with other switch. |
| 81 | Supply and fixing Switch piano, flush type 5 Amps, 240 V One Way complete all as specified and directed. |
| 82 | Supply and fixing switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 83 | Supply and fixing switch socket combination 16 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 84 | Supply and fixing Ceiling Rose 3 terminal size 50 x 65 mm surface type complete all as specified and directed. |
| 85 | S&F 1x20 W LED 6000K (4 ft) decorative ultra slim sqare profile linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, extruded aluminium body heat shrink, provided for efficient dissipation and integrated electronic driver complete with lamp. |
| 86 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers |
| 87 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 88 | Supply and fixing of Single Pole and Neutral, Single Door, 240 V, 4 way Sheet Metal Enclosure for MCBs complete all as specified and directed. |
| 89 | Supply and fixing of SPN 32 Amp, 240V, 10KA \"C\" curve miniature circuit breaker (MCB) complete with connection testing and commissioning. |
| 90 | Supply and fixing of SP 5 to 32 Amp, 240V, 10KA \"C\" curve miniature circuit breaker (MCB) complete with connection testing and commissioning. |
| 91 | M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 92 | M&L for river sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after laying and streching the cable, complete all as specified and directed by Engr-in-Charge.Note :- For payment purpose punned thickness shall be measured |
| 93 | M/Lfor brickwell burntlocallyavailablesubclass \"B\" laid over sand cushioningtocableintrencheskeepingwidthofbrickparalleltothelengthofcable complete allasspecifiedanddirected. |
| 94 | M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 Core complete allasspecifiedanddirected. |
| 95 | Notes :- Amount of Credit Schedule for Schedule \"A\" Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. |