| 1 | Schedule \"A\" Part-I :- |
| 2 | Supply, Installation, Testing and commissioning in repair of Microprocessor based Multi-loop, True Peer to-Peer Networkable Addressable Fire Alarm Control Panel for 2 loop LCD display expandable upto 5 loop , 1000 event plus 1000 alarm log historyevents. The panel shall be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work with, 240 volts AC power supply, automatic battery charger, 2 x 12 Volts, DC sealed lead acid batteries sufficient for 24 hours normal working and 01 hrs in alarm condition. The fire alarm system shall comply with requirements of NFPA Standard 72 for The system shall be electrically supervised and monitor the integrity of all existing conductors Panel and detector, MCP and modules shall be of same make as approved by the GEas per requirement all as directed. Make- Edwards, Simplex, Honeywell, Mohinder, Kidde & IFC-Johnson |
| 3 | Supply, installation, testing and commissioning in repair Addressable Manual Call Point (Pull down/Break Glass Type) The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device. |
| 4 | Supply, installation, testing and commissioning in repair of addressable type Hooter cum Flasher flame proof type, rated at 75 dB at 3 metre for Audible annunciation and 75cd flashing at 1 Hz for visual indication with and including Control Module, complete all as specified and directed. Notes : The hooter shall be Central Mining Research Institute and Petroleum & Explosives Safety Organisation approved (ii) The Control Module shall be UL Listed |
| 5 | Supply & fix in repairsAddressable Multi-criteria Photo-Thermal and smoke Detector with sensitivity range of 0.5 to 4.0% obs/ft. The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches The detector shall be designed to meet UL Design criteria combination Complying with and type certified to EN-45 Addressable IS: 11360 |
| 6 | Supply and fixing in repairs 12V DC-7AH Battery along with suitable connection complete all as specified and directed |
| 7 | Supply and Laying in repair 2 Core 15 Sqmm copperconductor, Gl armoured, FRLS cable confirming to IS 1554 (Part-1) in casing capping trenched/fixing along wall/floor/ceilling with and including Gi saddles, clamps, Nylon cable ties etc complete all as specified and directed. |
| 8 | Supply, installation, testing and commissioning of FM approved and UL listed intelligent monitor module in repair , with built-in type identification automatically identifying the device as addressable monitor module to the FCAP, to supervise a circuit of dry-contact input devices, viz. flow switch of sprinkler line, powered directly by two-wire SLC loop, high noise immunity, SEMS screws with clamping plates for ease of wiring, direct-dial entry of addresses, LED indicators, etc. complete all as specified and directed by the Engineer-in-charge. |
| 9 | Supply, installation, testing and commissioning of FM approved and UL listed addressable control module in repair to provide FACP a circuit for notification appliances (e.g. Horns, Strobes, Horn Strobes, etc.) having built-in type identification, integral LED indicators, high noise immunity, SMES screws with clamping plates for wiring ease, direct-dial entry of address, etc. complete all as specified and directed by engineer-in-charge.(Power shutdown to all lifts other than Fire lifts in case of fire alarm). |
| 10 | Supply, installation, testing and commissioning of FM approved and UL listed intelligent Short circuit isolator in repair , with built-in type identification automatically identifying the device as addressable fault isolator module to the FCAP, to supervise a circuit of dry-contact input devices, viz. flow switch of sprinkler line, powered directly by two-wire SLC loop, high noise immunity, SEMS screws with clamping plates for ease of wiring, direct-dial entry of addresses, LED indicators, etc. complete all as specified and directed by the Engineer-in-charge. |
| 11 | Supply, installation, testing and commissioning SITC of response indicator consisting of red LED in a suitable galvanised steel junction box with mounting accessories. |
| 12 | Supply and fixing in repair paddle type flow switch (Swifzer/ Danfoss) on pipes with welded socket including stainless steel paddle suitable to pipe dia 150 mm to 25 mm testing and commissioning etc complete.Note : Rate is inclusive of cable from flow switch to panel |
| 13 | Supply, installation, testing & commissioning in repair 24VDC power supply unit for sounder cum strobes. The unit shall have in built battery charger & sufficient back of 24 hours in stand by & 30 mins in alarm condition. The power supply unit shall be monitored by fire alarm panel. |
| 14 | Schedule \"A\" Part-II :-Comprehensive maintenance including all repair/ replacement and preventive maintenance / servicing of fire alarm system and its connected components consisting of addressable type fire alarm panel, addressable type detector, manual call point, contol module, monitor module, response indicator, short circuit isolator, flow switch, batteries, cables and other components connected to fire fighting system by OEM throughout 12 months on all days including sunday and holiday for period of 1 years after expiry of defects libality period (24 Months) as shown below and all as specified and directed by AGE/ GE. |
| 15 | First year after expiry of defects libality period |
| 16 | Second year after expiry of defects libality period |
| 17 | Third year after expiry of defects libality period |