| Sl. No. | Item Description |
| 1 | Electric work |
| 2 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 3 | Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR - Cat 6, Un-sheilded Information Outlet |
| 4 | Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR - Single Aperture |
| 5 | Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick withearthingterminal andadjustablefloatingclampinrecess/surfacesuitablefor modular accessoriesas required.All asper preapproved byEngineer incharge. Foradditional technicalparameters ofproducts/work , refer Annexure\"A\"attachedwiththis BSR . - 1-2 Module |
| 6 | Supply,Drawing and Testing, of stranded Single mode(9/125µm) glass optic fiber cable, as per latest ammendmentsofTIA/EIA568/ISO/IEC,constructionofLSZHoutersheathcable, cableshouldbeusedforLANandWANbackbones, .WithitsLSZHsheathingthesecables shouldbeidealforindoor/outdoor installationsinexistingMS/PVC/HDPEConduits/slotted channelswithferrulingatbothendsfor identificationcompleteinallrespect.Allasperpre approvedbyEngineer incharge. Foradditional technicalparametersofproducts/work , refer Annexure \"A\" attached with this BSR 12 Fiber |
| 7 | Supply, Installation, & Testing of 19\" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable adapters for ST/E-2000/SC/LC/MT RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .- LIU 12 Ports |
| 8 | Supply, Installation,&Testingof19\"1URackMounted/surfacemountedaluminum/CRCA 1.2mmpowder coated,multimodeglassFiberOpticCablePatchpanel/LIU loadedwith flangless/screwable adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removableTopplatewithpushbuttons, thereshouldbeasplicetrayinstalledinthePatch panel/LIUwhichcanhandlethefibercores,splicetrayshouldbePC+ABSmaterial, itshould includeaccessories likemountinghardware, gormetts, heat shrink tubes/sleevs, screws, nutstoinstallthepanelforrack/wallmountapplicationsasperrequirementcompleteinall respect.AllasperpreapprovedbyEngineerincharge. Foradditionaltechnicalparameters of products/ work , refer Annexure \"A\" attached with this BSR . Mode LIU 6 Ports |
| 9 | Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS1/OS2)madeofglassfiberopticwithLSZHjacket,F82.0x4.1mm,yellow, singlemode G652.D(9/125µm(OS1,OS2) MountedonbothsideswithST/E-2000/SC/LC/MT-RJ/PC typeDuplex connectors inacc.with IEC61754-20. Zirconia (ceramic) ferrulewithaPC polishedendfacegeometry,connectorsshouldbetunedinaccordancewithIEC61755-3-1 andqualifiedinacc.withIEC61753-1forcategoryU(uncontrolledenvironment,duplexclip and white plasticdustcover, should comply todeltaIL |
| 10 | Fiber Fusion Splicing with OTDR Testing of Fiber Single/ Multi mode (per splice) of glass Fiber Optic Cable including cleaning the cable and making splice as per standard practice complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR |
| 11 | Supply , Installation, Testing and Comissioning of Hot pluggable Small FormFactor Pluggable (SFPModule), 1000BASE-SX, 1.25/2.125G Fiber Channel, LC Type Duplex Connector,850nmlasertransmitter,Shouldsupportdistanceupto500mon50/125umof data rate upto 2.125Gb/s onbi-directional data links. Should also support industrial temperature,shouldhavemetalenclosurefor lowerEMI.ThetransceivershouldbeROHS Compliant. (ForEachMMFiber)all switches&relatedFibermodulesshouldbeof same make&categoryforseamlessintegrationwitheachotherofEnterpriseclass,completein all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR |
| 12 | Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communicationenclosure(Rack)madefrompowdercoated(60to80Micron)CRCAsheet, front sturdy sheet steel frame folded fromonepieceandweldedwithminimum5mm toughenedglass door,VerticalMountingRail 1.6MMwith \"U\"Marking ,withAll round protectivechannelonthedooraperture, lock integratedonfrontdoor, topandbottom coverwithcableentryprovisionwithglandplates, integratedsidewalls,2pairof19\"angles withwallmountingprovisiononwall.Accessories like:1Noof19\"1UHorizontal Cable manager,1Noof90cfm230VACFanwith1mtslongcable,mountinghardware,1Noof 19\"1U,mountablesocketstripswith5nosof5Auniversalsocketswith2mtslongpower chordforsupplyingpower toswitches, fansetcalongwithearthcontinuitykit, indicator, mouldedpowersupplycable.fixingonwallwithSuitableAnchorfastner etcasrequired.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR 6 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 13 | S&F followingsizes (dia.) of ISImarked virginmaterial MMS ( IS:9537 P- III ) 25MMPVCconduit alongwith ISI marked (IS:3419-1988) accessories as required in recess including cutting thewall, coveringconduitandmakinggood thesameas required. 25 mm |
| 14 | SITC of 8port Giga Switch with dual uplink: unmanaged switch; 8X10/100/1000mbps Base-T 2*10/100/1000Base T(Uplink) or 2*1000Base-X(uplink): Consumption per Port: |
| 15 | Supply, installation, testing and commissioning of 100 kVA Online Double Conversion UPS system with minimum 5 minutes battery backup at full load Parameter Specification UPS Type Online Double Conversion (VFI) Rated Capacity 100 kVA / Minimum 80 kW Input Voltage 415 V ±15%, 3 Phase + Neutral + Earth Input Frequency 50 Hz ±5% Input Power Factor ≥ 0.99 Input THDi < 5% Output Voltage 415 V ±1%, 3 Phase + Neutral Output Frequency 50 Hz ±0.1%Output Power Factor ≥ 0.8 (Preferred 0.9) Output THDv < 2% (Linear), < 5% (Non-linear)Efficiency (Online Mode) ≥ 94% Efficiency (ECO Mode) ≥ 98% Bypass System Inbuilt Static Bypass & External Maintenance BypassUPS Technology IGBT based PWM Rectifier & Inverter Battery Type SMF / VRLA Maintenance Free Backup Time Minimum 5 minutes at full load DC System Voltage Approx. 384 V DC (as per OEM design) Battery Accessories MS Powder Coated Battery Rack, DC MCB, Interconnecting Cables Protections Over/Under Voltage, Overload, Short Circuit, Thermal, Battery Protection Monitoring LCD Display for Input/Output, Load %, Battery Status & Alarms Communication RS-232 / USB, SNMP Card (Optional) Operating Temperature 0°C to 40°CRelative Humidity Up to 95% Non-condensing Standards IS/IEC 62040, IEC 61000 Installation Scope Supply, Installation, Testing, Commissioning, Earthing & Trial Run Warranty 3 Years Comprehensive Onsite Warranty Preferred |
| 16 | Providing and fixing of commercial RO water purifier including Inbuilt Purification capacity-150-200 litre/hour, Ro+uv+uf +tds djuster.,suitable for borewell water.Installation Type Wall Mounted. |
| 17 | Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler with hermetically sealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick) and tank (0.5 mm thick) , stainless steel water tray,minimum two nos Brass Chrome plated faucets and suitable drainage system complete in all respect with required height MS fabricated and Painted Angle iron frame ( Cost of frame to be paid Extra )complete in all respect of the following capacity. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs |
| 18 | SITC of IR lP Based 5 MP Dome camera . 1/2.8” Progressive CMOS, ICR, lR2560(H)x1920(V):25fps(P) , 2.8/3.6 mm lens (As per site requirement) i- 26a, H265/MJGEG, dual-stream, I 20dB PDR or beiter, 3D DQ BLC, lR minimum 30 mtr, Provision for Support on-board storage up to 256 GB (SD card no\" included), intrusion detection, Line crossmg detection, Motion detection, Dynamic anal7sis› Alarm should be trigger on {Tampering alarm, Network disconnect, IP address conflict, Storage exception), secwity feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard tc support ONV£F (PROFILE S, PROFILE G), Metal Housing, Vandal-proof housing IP 67, DC I 2V & PoE, Complete with Junction box for cable management Oeratint Conditions : 20 °C - 50 °C or better. Model should be : CE, BIS,/UL,FCC,ROHS compliance. The CCTV OEM shoed have CMMt Level 5 or above or equivalen setup certification. The CCTV OEM shouid have its offioe and servicc/ support center in RajasthanAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure ”A\" attached with this BSS |
| 19 | Supply, Installation, Testing & Commissioning of 5 MP Varifocal Bullet Network Camera complete with all required specification and supporting accessories. -1/2.7 inch Progressive Scan CMOS, 2592 × 1944 at 25fps, 2.8 mm Fixed lens, 0.003 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, BLC, HLC, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage including SD Card up to 256 GB , IP67, Alarm 1 inputs, 1 outputs, Audio 1 inputs, 1 outputs, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Region entrance detection, Region exiting detection, Scene change detection, Face capture, Video tampering, audio exception detection, False alarm reduction through human and vehicle target classification based on deep learning CE, FCC, BIS certified |
| 20 | Supply, Installation, Testing A Commissioning of 16 ch NVR Pre-licencfl, NVRsupports upto 40 TB HDD Support, I6ch IP inputs; ; Support ANR tectinology 320mbps incoming bandwidth, supports up to I2MP full channel recordin8; supportH.265 compression; l6ch syncronised playback @1080p; support 3rd party caméras ONVIF type; 4K output; minimum 04 sATA HDD Slots; each slot should supppori upio IOTB HDD; Dual gigabit self adoptive Ediemct interface; serial inteface; USB interface; (all cameras and Storage-NVà should be of same mie tot the smooth functioning of the system).complète with mounting accessories & junciion box (to tie provided by OEM) for cable management. Model should be Cenificatcs of CompJiance: UL, CE/FCC, BIS. The CCTV OEM should have CMMI Level S or aboie or equivalent setup certification. The CCTV OEM should have its office and service/ support center in RajasthanAll as per pre approved by £ngineer in charge for additional techriical parameters of products/ work , refer Annexuic \"A\" aitached with this BSR |
| 21 | Supply. Installation, Testing & Commissioning of of 3.5\" 6 TB SATA ,USB 3.0Surveillance Hard Disk .All as per pre approved by Engineer in charge. For addiüonal technical pararneters of produets/ york , rater Arinexun ”A\" aliachedWith this BSR |
| 22 | Supply, Installation, testing and coinmissioning of BIS compliancc Professionalseries Diagonal Screcn sÎze 43\" LED with Résolution 3.840 x 2,160 (4K UHD) along with Static (Panel) Conoast Ratio (1300:1) or better with viewùig angle o 178/178 degree with response time of 8ms along with fmMl fn 2.0 - 2 nos., USB 2.0 2 nos., RS 232- 1 nos., Rf 45- I Nos. with Built in Speairer(10W + l0W, ) with high speed processor and andrnid or other reputated operationg system along with 4 GB RAM along with all audio and video decoder, Stand-by / sleep / off mode power 0.5 wa+t, All as per pro approved by Engineer in charge. For additional technicai parameters of products/ worf , inter Annexwe •A” attached with this BSR |
| 23 | supply installation testing & commissionin 8-Port 10/100/1000Mbps PoE+ Switch with 2Giga Uplink Connector 8 x 10/100/1000BASE-T RJ45 auto MDI/MDIX ports 2 x 10/100/1000BASE-T RJ45 auto MDI/MDIX ports 2 x 1000 Base-X SFP Slots PoE+ Port 8 x 10/100/1000Mbps PoE. Distance vary the module Thermal Fan Fanless Design LED indicators Power Indicator: PWR(green). Network Indicator: Link(yellow) PoE+ Working Indicator: PoE+(green) Switch Architecture Store and Forward Transmission model IEEE802.3X full-duplex with Duel SFP |
| 24 | SITC of Media Convertor for support of CCTV System Designed to convert 1000BASE-LX fiber to 1000Base-T copper media or vice versa Works at 1000Mbps in Full-Duplex mode for both TX port and FX port Supports auto MDI/MDIX for TX port and provides switch configuration of Force/Auto transfer mode for FX port Extends fiber distance up to 15km (9.3 miles)Easy-to-view LED indicators provide status to monitor network activity easily External power supply. Wave Length: 1310nm. Max Power Consumption:1.8W Complete in all respect with all required accessories .Test report / certificates of manufacturer which are to be needed is to be submitted by contractor.Make : make is to be approved by deparment |
| 25 | Supplying and fixing of 24 Port Network Switch 10/100/1000 switch with 2 GIGA Uplink Port Make : D-link/Netgear/Cisco/HP/Zyxel |
| 26 | Supply, Drawing and Testing, of stranded Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 6 fiber |
| 27 | Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569 Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 28 | Supply, Installation, & Testing of 19\" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Multi Mode LIU 6 Ports |
| 29 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 20 mm |
| 30 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 3x 1.5 sq.mm |
| 31 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 32 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 1 x 4.0 sq.mm |
| 33 | Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Poles with Octagonal Cross Section 4 Mtr. |
| 34 | Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. Pole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr. |
| 35 | Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Minimum lumen output 4000 lm Post top Luminarie |
| 36 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 37 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade |
| 38 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating |
| 39 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Four pole MCB (With B/C curve tripping Characteristics) 80 A rating |
| 40 | SITC of Outdoor LED sign board with LOGO on size of min. 24*8 feet including sub component :- ACP sheet of 3 MM thickness, Acrylic sheet of 3 MM rising of 2.5 inches with male and female option . Best quality LED modules with three year warranty having 170 degree viewing angle with 100 LM with complete water and dust proofing . M S angle and iorn framing etc as required |
| 41 | Civil work |
| 42 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil |
| 43 | Dismantling upto 1.5m in foundation and/or 1.5m above ground level including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material, and stacking serviceable material within a lead of 1000m. [MoRTH Specification clause 202] Dry Rubble Masonry |
| 44 | Dismantling upto 1.5m in foundation and/or 1.5m above ground level including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material, and stacking serviceable material within a lead of 1000m. [MoRTH Specification clause 202] Carriage of material Earth ,Sand ,Lime ,Morrum,manure or sludge |
| 45 | Providing and laying in position cement concrete including curing, compaction etc.complete in specified grade excluding the cost of centering and shuttering -All work up to plinth level. 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size). |
| 46 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers(if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix/Design Mix Providing M-25 grade concrete by using min 410kg of cement per cum instead of M-20 grade design mix. |
| 47 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 48 | Providing and fabricating reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo- mechanically Treated bars (Conforming of relevent IS code) For Fotting 12mm RCC Qty x 7850x 2.0% RCC Qty x 7850x 2.0% |
| 49 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation,footings, strap beam,raft,bases of columns etc. GF Footing F1 [2.10 X 2.10] |
| 50 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 115.2 |
| 51 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. Random rubble dry stone Kharanja under floor. |
| 52 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors,roofs,landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchor blocks, sills,chhajjas,lintel, beam,plinth beam etc. |
| 53 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors,roofs,landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchor blocks, sills,chhajjas,lintel, beam,plinth beam etc. Columns, pillars, posts and struts etc. |
| 54 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design MixProviding M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix. |
| 55 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M25 grade Nominal Mix / Design Mix Providing M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix. Roof beams and slab and tank top and bootom |
| 56 | Brick work with clay flyash F.P.S. brick (IS 13757- 1993) of class designation 75 in superstructure above plinth level upto floor five level in:Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 57 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish : 20mm thick. |
| 58 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish : 20mm thick. 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) |
| 59 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab from 2001 to 5000 Sqcm |
| 60 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : Ist course of applying cement slurry @4.4 Kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water. proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.. IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area. IVth course of 400 micron thick PVC sheet.(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 61 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). |
| 62 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 63 | Providing and fixing aluminum work for doors,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately). For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 64 | Providing and fixing aluminum work for doors,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium For fixed portion Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 65 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) |
| 66 | Providing and applying white cement based putty over plastered surface to prepare the surface evenand smooth complete |
| 67 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 68 | Providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machine complete on 20 mm thick bed of cement sand mortar 1 : 4. |
| 69 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail