| 1 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material out of ACTREC premises with lead and lift,. Valid gate pass complete as directed and instructed. |
| 2 | Providing & Applying one / two coatsof primer & thereafter two coats of paint as mentioned First quality to the required colour scheme and as per manufacturers instructions / specificationsto the walls, beams, columns, ceilings, partitions doors etc. including thoroughly scrapping the existing surface with sand papers, removing old paint, filling up crevices and levelling with waterproofputty / plaster of paris of necessary to obtain smooth surface etc. complete job including removal of stains, painting spots on floors,aluminium window frame & glassetc asto the entire satisfaction of engineer in charge :With Luster Paint two coats of primer and two coats ofpaint. ( Rate inclusive of scafflolding, labour charges, ladder etc.) |
| 3 | Providing and fixingsun control/black out/ tinted/ frosted films 2 mil thick film on window glasess without damaging rubber gaskets, handle , friction hinged etc complete including neccesary scafolding job is to be complited as per manufacturer\"s film specification and as directed by EIC alongwith design and writings if any. |
| 4 | REMOVING DOORS & WINDOWS:Labour charges only for carefully removing and takingoutexisting steel, doors/wooden partition/metal frame/ windows/celestory window shutters from its existing position at all floors levels and locations including chiseling around the frame hold fasts carting away debris making good the chiseled surface suitably as per the site requirement and shifting theatdismantled materials to the directed place with stacking in proper order including removing the existing fittings, fixtures locking arrangmeent and returning the same to the Department of respective maintenance unit etc. complete all as directed by the Engineer-in-Charge |
| 5 | Providing and laying Vitrified tiles in floor and walls in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600, 600 x 1200 size tiles. |
| 6 | Providing and fixing tiled powder coated metalfalse ceiling of size 595x595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of Aluminum sheet having electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 7 | Providing and fixing Below height storage unit (750mm deep) made out of 18mm thk. approved make water & termite proof Plywood. Shelves (2 nos. equally divided) made out of 18mm thk. Ply with TW lipping. All the surfaces including edges and the front shall have 1.0 mm thk. Laminate of approved make and colour as shown or directed. Shutters made out of 18mm thk Block board / Plywood .All the surfaces including edges and inside with 0.8 mm thk laminate and outside with 1 mm thk laminate of approved make and colour with joints as shown or directed. Each shutter shall have 75 mm long black oxidised brass butt hinges. Minimum 2 nos. hinges. Shutters will have magnetic catch fixed at top and bottom. 75mm wide \"C\" shaped brush steel approved handle. |
| 8 | Providign and Supplying ModularLinear Workstation 1200mm(L) x 600mm(D) 1 50mmthkFullyAluminiumTilebasepartitionsystem, dulyPowdercoated upto50micronsofheight1200mmwithheavydutylevellersatbottomhaving fabric/softboard/whiteboard/prelaminated laminate tiles. \"Rectangular\" shapeWork top of size1200x600mm,madeof 25mmthick prelaminated particleboard with pvc edgebinding supported on25mmthk. Return partition 50mm aluminum partition (Pedestal unit, Keyboard tray & cpu trolley not considered).(The entrie work station design / colour scheme to be got approved with supply of physical sample at site before supply in full qty.) complete as directed and instructed. |
| 9 | Providing and supplying the High / Medium / Low Backchair of approved make and series with Net Back, Fabricupholstred seat, ABS cantilever arms, S S Legs with Castors, Gas Lift, Syncro lift mechanism etc. and complete the same all as approved. (Sample chair to be got approved before supply in full qty.) |
| 10 | Electrical Works |
| 11 | Submain Wiring from DB to sockets |
| 12 | SITC of Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVCconduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireincluding PVC conduicts , bends , and all fixing accessories( Rate for one mtr circuit i.e.3 x 2.5sqmm wire) for power points |
| 13 | SITC Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable including surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire FOR POWER POINTS |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | Double pole |
| 16 | DP MCB Enclosure box Metal type IP 67 TYPE C MCB |
| 17 | LIGHTING |
| 18 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internalsurge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum powerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 19 | Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 36 watt |
| 20 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required. |
| 21 | 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 22 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 23 | Point wiring |
| 24 | SITC of Primary point wiring for light point/ fan point/ exhaust fan point/ call bell point with 2 x 1.5sqmm + 1 x 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed includingmedium class PVC conduit Heavy(HMS) / casing capping , with modular switch , modular plate,suitable GI box for concealled , suitable PVC box for surface, ceiling fan rose, PVC junction box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Average circuit lenght 20 mtr) |
| 25 | SITCSecondary point wiring light to light looping with 2 x 1.5sqmm + 1 x 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed includingmedium class PVC conduit Heavy(HMS) / casing capping , with modular switch, modular plate,suitable GI box for concealled , suitable PVC box for surface, ceiling fan rose, PVC junction box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. ( Average circuit length 10 Mtr ) |
| 26 | PVC Conduict pipes for LAN wiring |
| 27 | Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON |
| 28 | Supplying and erecting HMS PVC conduit 32mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON |
| 29 | Supplying and fixing following size/ modules, PVC / GI box alongwith modular base & cover plate for modular switches in surface orrecess etc. as required. • All the power socket tagging to be provided , PVC tags to be provided.• All the power sockets inside and power panel insidewiring ferruling to be done as instructed by EIC ES |
| 30 | 3 Module |
| 31 | 6 Module |
| 32 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 33 | Modular switch 6A/16A |
| 34 | Modular Socket 6A/16A |
| 35 | IT Networking |
| 36 | SITC of CAT 6 LAN cable for DATASupply ,Installation,Testing & Commisioning of of UTP 23 AWG 4 pair CAT 6 LAN Cableto TIA/ EIA 568 B.2.1.in the surface/ recessed steel/ PVC conduit as required. All the cabe to be connected in IT rack with RJ 45 connector. |
| 37 | SITC of RJ 45 connector |
| 38 | SITC of Cat 6 type I/O with RJ 45 socket with Box, faceplate and fixing screws, having the compliance/certifications for ISO 9001:2015 & ROHSSupplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/ULverification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 39 | SITC of fully loaded RJ-45 24 port Patch Panel with tool-less keystone jacks having the compliance / Certifications for ISO 9001:2015 & ROHS |
| 40 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required |
| 41 | Supplying and fixing (rack dressing) 1 meter length, UTP Patch cord of Cat 6 type in position having the compliance / Certifications for ISO 9001:2015 & ROHS. |
| 42 | Supply ,Installation, Testing & Commissioning of 3 meter length, UTP Patch cord of Cat 6 type, having the compliance/certifications for ISO 9001:2015 & ROHS |
| 43 | Telephone |
| 44 | SITC of CAT 6 LAN cable for DATASupply ,Installation,Testing & Commisioning of of UTP 23 AWG 4 pair CAT 6 LAN Cableto TIA/ EIA 568 B.2.1.in the surface/ recessed steel/ PVC conduit as required. All the cabe to be connected in IT rack with RJ 45 connector. |
| 45 | SITC of RJ 45 connector |
| 46 | SITC of Cat 6 type I/O with RJ 45 socket with Box, faceplate and fixing screws, having the compliance/certifications for ISO 9001:2015 & ROHS |
| 47 | Telephone instrument analogue type caller ID |
| 48 | Removing of existing electrical fixtures , wiring , PVC conduicts , casing cappings, LAN wiring , IT devices , Fire alarm devices ,etc as directed by EIC ES |
| 49 | Refixing of all fire alarm system devices , IT networking devices , power point an dcat 6 wirings etc as directed by eic es |
| 50 | HVAC WORKS |
| 51 | HVAC-AHU |
| 52 | Supply, Installation, Testing and Commissioning of chilled water Fan Coil Unit(Cassette Type/ Hi Wall/ Fan Coil Unit- Ceiling) complete with G.I. casing, with Side/bottom return Air Plenum (5mm PE insulation) or as per site requirement For Hi Wall Units the Casing has to be as per OEM(ABS casing) , Filter box with 8mm Nylon Filter, 3 Row Deep cooling coil with coper tube diameter is 9.52 mm and thickness 0.33 mm with hydrophilic Aluminium fins. Complete coil must be designed for standard working pressure is 1.6 MPa(16bar) and the test pressure is 3.3MPa(33bar). Unit to be provided with SS drain pan with 7mm PE insulation and +200 mm extended. Direct driven fan (three speed) motor, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with Wireless remote. It shall also have RS485 Modbus communication function for BMS control. ESP for the Fan Coil Unit be 80 Pa Minimum( In case of 3 Tr, 4 Tr and 5 Tr) or Else Specified. Units need to BIS/Euro vent Certified.The unit included withInfrared Remote Control,micro-controller, drain pump & necessary supporting arrangement with ready made Valve Station complete with butterfly Valves / Gate valves , 2 way Valves (PIBCV valve)with Actuators–Strainer. The entire skid shall be coated with Zinc-chromate primer coating and then painted with enamel paint. Price should be included for Electrical cable connection from MCB/Isolatorto Cassette unitshall be done by HVAC contractor. Pipe line require from the main header also to be considered. no additional cost given for the same. Minimum Capacity should be as follows: |
| 53 | Each Unit to be provided with Cordless Remote with Temperature display. It has to based on microprocessor operations which can realize intelligent control of room temperature. It shall also have RS485 Modbus communication function or BACnet for BMS control. (Preferably in round shape) |
| 54 | 2 TR (800CFM) Decorative Hi wall unit |
| 55 | core cutting |
| 56 | Supply, Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows, tees, reducers,sockets,u trap etc.) supports, jointinginsulated with XLPE class O tubular insulation and any other item required to make the system complete. Nominal diameters of pipein mms as indicated below: |
| 57 | 25 mm dia pipe, Insulation thickness - 6 mm |
| 58 | Dismatling of existing ducting , grill, dampers,and accessoriesetc as per instructed and as directed by OIC-ES |