Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SH : Museum Building |
| 2 | SH : I : EARTH WORK. |
| 3 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 4 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 5 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 6 | SH :- II:CEMENT CONCRETE WORK. |
| 7 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 8 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 9 | Providing and laying damp proof course 38 mm thick with cement concrete 1 : 2 : 4 (1cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size). |
| 10 | SH : III:R.C.C.WORK |
| 11 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) 1 : 1: 2 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size) |
| 12 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) 1 : 1: 2 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size). |
| 13 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1: 2 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size) |
| 14 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 15 | Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers bands and facias up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding the 6 mm to give a smooth and even surface but excluding the cost of centering, shuttering and reinforcement with M25 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size). |
| 16 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M25 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size). |
| 17 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 18 | b)Columns, pillars, posts and struts etc. |
| 19 | c)Lintels, beams, girders, bressumers and cantilevers etc. |
| 20 | d)Suspended floors, roofs, landings shelves and their supports balconies and chajjas (3.5m height). |
| 21 | e)Stairs (excluding landing) except spiral stair cases. |
| 22 | Reinforcement of RCC work including bending, binding and placing in position complete.a)Cold twisted bars. |
| 23 | SH : IV: BRICK WORK. |
| 24 | Random rubble masonry with hard stone in foundations and plinth in cement mortar 1 : 6(1 cement : 6 fine sand) including levelling up with cement concrete 1 : 6 : 12 (1 cement :6 coarse sand : 12 stone aggregate 20 mm nominal size) at plinth level. |
| 25 | Extra for random rubble masonry with hard stone in superstructure above plinth level and up to floor two level including levelling up with cement concrete 1 : 6 : 12 (1 cement : 6 coarse sand : 12 stone aggregate/shingle 20 mm nominal size) at window sills, ceiling level and the like.. |
| 26 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 27 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 28 | SH : V : WOOD WORK |
| 29 | Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.a) 40 mm thick including anodized aluminum butt hinges with necessary screws. |
| 30 | Providing and fixing anodised aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections of approved make confirming to IS : 733 and IS : 1285, anodised transparent or dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt, etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle. Aluminium snap beading for glazing/panelling, CP brass/stainless steel screws, all complete as per architectural drawings and the direction of engineer-in-charge. |
| 31 | Bed & Other Door Shutters:- Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mmfor styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 5mm shall be flat and 20 mm shall be tapered in 45 degree on the inner sideto form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer\"s specification & drawing. a) 30 mm thick plain PVC door shutters |
| 32 | Providing and fixing louvers 50 mm wide in grooves in clerestory windows frames excluding the cost of frames.f) Glass sheet 3 mm thick |
| 33 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 34 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.a)Plain Grill. |
| 35 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a)250 x 10 mm |
| 36 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a)125 mm |
| 37 | Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia wooden curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. (a) Timber class - A IV |
| 38 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a)300 x 16 mm |
| 39 | SH : VI : STEEL WORK. |
| 40 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 41 | Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. b) In Tees, Angles and Channels |
| 42 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 43 | SH:VII:FLOORING |
| 44 | Providing and laying polished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorptions less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.a)Size of Tile60x60 cm |
| 45 | Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: B) Medium Shade using 50% white cement , 50% ordinary cement. |
| 46 | SH : VIII : FINISHING |
| 47 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 48 | 6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand). |
| 49 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 50 | SH : IX : ROOFING |
| 51 | Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand).a)75 mm diameter pipe |
| 52 | Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10 cm x 10 cm x 10 cm of 1 : 2 : 4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc.a)75 mm diameter pipe |
| 53 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement: 2 fine sand).(A) CI Plain bend a) 150mm diameter |
| 54 | Providingand fixing Durashine zinc-Aliminunium alloy coated (TATA Bluescope building product) sheet roofing fixed with nessary fasteners and lapping method as described by the manufactured inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafteres and trusses. |
| 55 | Providingand fixing Durashine zinc-Aliminunium alloy coated (TATA Bluescope building product) sheet ridges fixed with nessary fasteners and lapping method as described by the manufactured inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafteres and trusses. |
| 56 | SH:X:DRAINAGE |
| 57 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 58 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.a)100 mm dia S W pipe |
| 59 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.a)100 mm dia S W pipe |
| 60 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design |
| 61 | SH : XI: WATER SUPPLY. |
| 62 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a)15mm nominal bore. |
| 63 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a)15mm nominal bore. |
| 64 | Providing and fixing brass bib/pillar cock of approved qualitya)15mm nominal bore. |
| 65 | Providing and fixing brass stop cock of approvedquality.a) 20mm nominal bore. |
| 66 | SH:XII:SANITARY INSTALLATION |
| 67 | Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.a) WC pan with white plastic seat and lid. |
| 68 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 69 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 70 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 71 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).a)750 x 20 mm |
| 72 | Providing and fixing sand cast iron cast/iron (spun) soil, waste and vent pipes.b)100 mm dia. |
| 73 | Providing and fixing sand cast iron heel rest sanitary bend.b)100 mm dia. |
| 74 | Providing and fixing sand cast iron single equal plain junction of required degreea) 100 x 100 x 100 mm |
| 75 | Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a)100mm inlet and 100mm outlet. |
| 76 | Providing and fixing toilet paper holder. (a) CP Brass |
| 77 | Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm |
| 78 | SH : XIII MISCELLANEOUS |
| 79 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth |
| 80 | Providing and fixing hydraulic door closer of approved brand and manufacture IS : 6315 marked, for doors including fixing etc. complete as per the direction of Engineer-in-charge. |
| 81 | SH : XIV SEPTIC TANK (2 Nos) |
| 82 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 83 | Extra for every additional lift of 1.50 m or part thereof for earth work in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock. |
| 84 | Concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering. |
| 85 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 86 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 87 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 88 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 89 | Centring and shuttering including strutting, propping etc. and removal of form work for:a)Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height) |
| 90 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 91 | 12 mm thick cement plaster 1:3( 1 cement : 3 fine sand) |
| 92 | Neat cement punning |
| 93 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. a) 40 mm thick. |
| 94 | SH : XV EXTERNAL WATER SUPPLY |
| 95 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 50 mm nominal bore |
| 96 | SH : Resturant |
| 97 | SH : I : EARTH WORK. |
| 98 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 99 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 100 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 101 | SH :- II:CEMENT CONCRETE WORK. |
| 102 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 103 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 104 | Providing and laying damp proof course 38 mm thick with cement concrete 1 : 2 : 4 (1cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size). |
| 105 | SH : III:R.C.C.WORK |
| 106 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) 1 : 1: 2 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size) |
| 107 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) 1 : 1: 2 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size). |
| 108 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1: 2 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size) |
| 109 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 110 | Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers bands and facias up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding the 6 mm to give a smooth and even surface but excluding the cost of centering, shuttering and reinforcement with M25 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size). |
| 111 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M25 (1 cement : 1 coarse sand : 2 stone aggregate 20 mm nominal size). |
| 112 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 113 | b)Columns, pillars, posts and struts etc. |
| 114 | c)Lintels, beams, girders, bressumers and cantilevers etc. |
| 115 | d)Suspended floors, roofs, landings shelves and their supports balconies and chajjas (3.5m height). |
| 116 | Reinforcement of RCC work including bending, binding and placing in position complete.a)Cold twisted bars. |
| 117 | SH : IV: BRICK WORK. |
| 118 | Random rubble masonry with hard stone in foundations and plinth in cement mortar 1 : 6(1 cement : 6 fine sand) including levelling up with cement concrete 1 : 6 : 12 (1 cement :6 coarse sand : 12 stone aggregate 20 mm nominal size) at plinth level. |
| 119 | Extra for random rubble masonry with hard stone in superstructure above plinth level and up to floor two level including levelling up with cement concrete 1 : 6 : 12 (1 cement : 6 coarse sand : 12 stone aggregate/shingle 20 mm nominal size) at window sills, ceiling level and the like.. |
| 120 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 121 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 122 | SH : V : WOOD WORK |
| 123 | Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.a) 40 mm thick including anodized aluminum butt hinges with necessary screws. |
| 124 | Providing and fixing anodised aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections of approved make confirming to IS : 733 and IS : 1285, anodised transparent or dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt, etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle. Aluminium snap beading for glazing/panelling, CP brass/stainless steel screws, all complete as per architectural drawings and the direction of engineer-in-charge. |
| 125 | Bed & Other Door Shutters:- Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mmfor styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 5mm shall be flat and 20 mm shall be tapered in 45 degree on the inner sideto form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer\"s specification & drawing. a) 30 mm thick plain PVC door shutters |
| 126 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.a)Plain Grill. |
| 127 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a)250 x 10 mm |
| 128 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a)125 mm |
| 129 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a)300 x 16 mm |
| 130 | SH : VI : STEEL WORK. |
| 131 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 132 | Providing and fixing of readymade stainless steel railing as per the direction of Engineer-in-Charge |
| 133 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 134 | SH:VII:FLOORING |
| 135 | Providing and laying polished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorptions less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.a)Size of Tile60x60 cm |
| 136 | Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: B) Medium Shade using 50% white cement , 50% ordinary cement. |
| 137 | SH : VIII : FINISHING |
| 138 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 139 | 6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand). |
| 140 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 141 | SH : IX : ROOFING |
| 142 | Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand).a)75 mm diameter pipe |
| 143 | Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10 cm x 10 cm x 10 cm of 1 : 2 : 4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc.a)150 mm diameter pipe |
| 144 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement: 2 fine sand).(A) CI Plain bend a) 150mm diameter |
| 145 | Providingand fixing Durashine zinc-Aliminunium alloy coated (TATA Bluescope building product) sheet roofing fixed with nessary fasteners and lapping method as described by the manufactured inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafteres and trusses. |
| 146 | Providingand fixing Durashine zinc-Aliminunium alloy coated (TATA Bluescope building product) sheet ridges fixed with nessary fasteners and lapping method as described by the manufactured inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafteres and trusses. |
| 147 | Providing and fixing 3 mm thick hard board sheet ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately). |
| 148 | SH:X:DRAINAGE |
| 149 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 150 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.a)100 mm dia S W pipe |
| 151 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design. a)100 mm dia S W pipe |
| 152 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design |
| 153 | SH : XI: WATER SUPPLY. |
| 154 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a)15mm nominal bore. |
| 155 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a)20mm nominal bore. |
| 156 | Providing and fixing brass bib/pillar cock of approved qualitya)15mm nominal bore. |
| 157 | Providing and fixing brass stop cock of approvedquality.a) 20mm nominal bore. |
| 158 | SH:XII:SANITARY INSTALLATION |
| 159 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) Long Pan patten WC Pan |
| 160 | Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.a) WC pan with white plastic seat and lid. |
| 161 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) One urinal basin with 5 Litres CI automatic flushing cistern |
| 162 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 163 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 164 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 165 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).a)750 x 20 mm |
| 166 | Providing and fixing sand cast iron cast/iron (spun) soil, waste and vent pipes.b)100 mm dia. |
| 167 | Providing and fixing sand cast iron heel rest sanitary bend.b)100 mm dia. |
| 168 | Providing and fixing sand cast iron single equal plain junction of required degreea) 100 x 100 x 100 mm |
| 169 | Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a)100mm inlet and 100mm outlet. |
| 170 | Providing and fixing toilet paper holder. (a) CP Brass |
| 171 | Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm |
| 172 | SH : XIII MISCELLANEOUS |
| 173 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth |
| 174 | Providing and fixing hydraulic door closer of approved brand and manufacture IS : 6315 marked, for doors including fixing etc. complete as per the direction of Engineer-in-charge. |
| 175 | SH : XIV SEPTIC TANK (1 Nos) |
| 176 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 177 | Extra for every additional lift of 1.50 m or part thereof for earth work in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock. |
| 178 | Concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering. |
| 179 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 180 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 181 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 182 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 183 | Centring and shuttering including strutting, propping etc. and removal of form work for:a)Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height) |
| 184 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 185 | 12 mm thick cement plaster 1:3( 1 cement : 3 fine sand) |
| 186 | Neat cement punning |
| 187 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. a) 40 mm thick. |
| 188 | SH : XV EXTERNAL WATER SUPPLY |
| 189 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 50 mm nominal bore |
| 190 | SH : LandScaping |
| 191 | SH:- RCC Boundary Wall with brick infill panels |
| 192 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 193 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 194 | Providing and laying in foundations and plinth cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 195 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 196 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost ofcentring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 197 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 198 | Centring and shuttering including strutting, propping etc and removal of form work for :Foundation Footing, base of colum etc |
| 199 | Lintel Beam girder bressumer and cantilever etc. |
| 200 | Column, piller post and strut etc |
| 201 | Reinforcement of RCC work including bending, binding and placing in position complete.Tar/TMT steel |
| 202 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 203 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 204 | Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.b) In Tees, Angles and Channels |
| 205 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 206 | Colour washing such as green, blue or buff on new work (two or more coats) including a base coat of white washing with lime to give an even shade. |
| 207 | SH : Pathways |
| 208 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 209 | Providing and laying in foundations and plinth cement concrete 1 : 2 : 4(1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 210 | Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: B) Medium Shade using 50% white cement , 50% ordinary cement. |
| 211 | SH : Drainage / Service Conduits |
| 212 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.i) Ordinary SoilA) Manual Means(i) upto 3m depth |
| 213 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical SpecificationsPCC Grade M15 |
| 214 | Laying Reinforced cement concrete pipe NP2/prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets .a) 300 mm dia |
| 215 | Sh : Manholes |
| 216 | Providing, excavation, construction and fixing of brick masonry manhole size 1.20 m length × 1.20 m width × 1.50 m depth using 2nd class bricks in cement mortar 1:5 (1 cement : 5 fine sand), foundation concrete M7.5 (1:4:8 mix - 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 300 mm thick, brick walls 230 mm thick, inside plastering 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement, RCC top slab 150 mm thick in M15 (1:2:4 mix - 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) reinforced with 8 mm dia MS bars @150 mm c/c both ways, including 600×600 mm CI/MS frame & cover (heavy duty), making inlet/outlet channels in CC 1:2:4 (20 mm aggregate), backfilling, all labour, materials, curing, testing for watertightness as per standard PWD/NBCC drawing and direction of Engineer-in-Charge, complete in all respects. |
| 217 | SH : Cement CementPavement Road |
| 218 | Excavation in Hilly Area in Ordinary Rock by Manual Means (Excavation in Ordinary Rock using Manual Means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.) |
| 219 | Granular Sub-Base with coarse Graded Material (Table : 400-2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC ,and compacting with vibratory roller to achieve the desired density, complete as per clause 401)for grading-I material |
| 220 | Preparation of sub grade (Preparation of sub grade by excavating earth to an average depth of 22.50cm, dressing to camber and consolodating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50m.) |
| 221 | Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc .and rerolling the sub grade. |
| 222 | Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.) |
| 223 | Separation Membrane of impermeable plastic sheeting 125 micron thick |
| 224 | Cement concrete pavement (Construction of un-reinforced, dowel jointed plain cement concrete pavement over a prepared sub base with 43 grade cement @400kg per cum, coarse and fine aggregate conforming to IS383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continous operation including provision of contraction, expansion, construction and longitudinal joints, joints filler, separation memberance, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing) |
| 225 | [SH: Iron gate] |
| 226 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 227 | Boulder Soling in foundation and plinth ramming, consolidating and dressing complete. (Dry rubble Flooring) |
| 228 | Re-filling excavated earth in plinth including watering, ramming, consolidating and dressing complete. |
| 229 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 230 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 231 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 232 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 233 | b)Columns, pillars, posts and struts etc. |
| 234 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Tar/TMT steel |
| 235 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 236 | White washing with whiting on new work (three or more coats) to give even shade. |
| 237 | SH :Electrical Works |
| 238 | SUB HEAD I :- INTERNAL WIRING |
| 239 | Point wiring in PVC conduit, with modular type switch :-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 240 | Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 241 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cableetc. as required. |
| 242 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 243 | Circuit / Sub main wiring in PVC conduit :-Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 244 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 245 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 246 | 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 247 | 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 248 | S/F light plug point Modular Type Accessories :-Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 249 | S/F power plug point modular Type Accessories :-Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 250 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 251 | SUB HEAD II :- DISTRIBUTION BOARDS & MCB\"sSupplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as Required.Single pole |
| 252 | Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).6 Way (4 + 18), Double Door |
| 253 | 8 Way (4 + 24), Double Door |
| 254 | Supplying and fixing following way, Single Pole and Neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).8 Way Double door. |
| 255 | S/F DP MCB IsolatorSupplying and fixing following Rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required.40 Amps |
| 256 | S/F 4P MCB IsolatorSupplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required.63 Amps |
| 257 | S/F DP (RCCB)Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as Required.40 Amps |
| 258 | SUB HEAD III :- TELEPHONE, TELEVISION & DATA SYSTEM (socket,wiring & conduting only) |
| 259 | S/F MODULAR BOXES, BASE & COVER PLATE :-Supplying and Fixing Following Size/ Modules, GI Box Alongwith Modular Base & Cover Plate for Modular Switches in Recess etc. as Required.1 or 2 Module (75 mm x 75 mm) |
| 260 | S/F MODULAR TYPE SWITCH / SOCKET :-Supplying and Fixing Following Modular Switch/ Socket on The Existing Modular plate & Switch Box including connections But Excluding Modular Plate etc. as required.Telephone Socket outlet. |
| 261 | TV Antenna socket outlet. |
| 262 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm. |
| 263 | 25 mm. |
| 264 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, Unarmored Telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 265 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 266 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable |
| 267 | SITC Modular Type Computer jack RJ 45 ISI mark 1 Module on existing Mounting plate and box Complete. |
| 268 | SUB HEAD IV :- INTERNAL LIGHTING FIXTURES & FANSNOTE : SELECTION OF LIGHT FIXTURE IS TENTATIVE FINAL SELECTION IS DONE BY ARCHITECT ONLY |
| 269 | Supply of 40W LED Linear Light with all accessories as required. |
| 270 | Supply of 43W (2x2) LED Light (Recessed) fitting suitable for 43 Watt LED Light with all accessories as required. |
| 271 | Supply of RecessedMounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc.as required. (Technical Data - System power 12W, CRI ≥80, Power Factor ≥0.95, System Luminous Efficacy ≥94). |
| 272 | Supply of RECESS Mounted Energy Efficient, LED Luminaires18W LED DOWN LIGHT (Round)Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc.as required. (Technical Data - System power 18W, CRI ≥80, Power Factor ≥0.95, System Luminous Efficacy ≥90) |
| 273 | Supply,of Linear & Compact 10W Mirror Light with Decorative Grey Caps, Polycarbonate Body & Ribbed Opal Diffuser. (Technical Data - System power 10W, CRI ≥80, Power Factor ≥0.95, System Luminous Efficacy ≥100). |
| 274 | Supply of LED LuminairesBATTEN20W LED Tube Light of Box Type Prewired Indoor Luminairewith Energy Efficient Electronic Ballast, with End Caps Complete as Required.(Technical Data - System power 20W, CRI ≥80, Power Factor ≥0.95, System Luminous Efficacy ≥100) |
| 275 | Supply of LED LuminairesBATTEN40W LED Tube Light of Box Type Prewired Indoor Luminairewith Energy Efficient Electronic Ballast, with End Caps Complete as Required.(Technical Data - System power 40W, CRI ≥80, Power Factor ≥0.95, System Luminous Efficacy ≥100) |
| 276 | Supply of Bulk Head Luminaire, heat resistant Glass cover . suitable for 10W to 15W LED or Equivalent. (Technical Data - System power 10W, CRI ≥80, Power Factor ≥0.95, System Luminous Efficacy ≥80) |
| 277 | SUPPLY FANS &EXHAUST FANS |
| 278 | Supply of Following sweep exhaust fan with guard suitable operation on single phase 230 V, 50Hz. AC Supply, with lowers / shutters in the existing opening. 300 mm sweep 900 rpm |
| 279 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as Required. |
| 280 | Installation of Exhaust fan in the existing opening, including making good the damage, Connection, Testing, Commissioning etc. as Required.Upto 450 mm sweep |
| 281 | Fixing Louvers / Shutters for Exhaust Fan: Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes. |
| 282 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing |
| 283 | UPS SYSTEMUNINTERRUPTED POWER SUPPLY (UPS) - 20 KVA |
| 284 | Supply of 20Kva Online UPS, IGBT UPS(Transformer-less Design).Supply of SMF Batteries (12Volt VRLA, 46Ah, 34 Numbersto provide 15 Min Backup in total for 20 kva UPS at 0.8PF and ECV=1.7V.Fully rated Inbuilt static switch at the inverter output and 100% rated Inbuilt static switch at the static bypass line integrated in UPS module.Supply of Local Accessories (like Cabling Between UPS and the Battery onsidering Cable Routing ,Battery Interlinks ,Battery Rack etc).Backfeed protection at Mains & Bypass(Inbuilt / External).Installation and Commissioning of 20 kVA UPS, Battery and Accessories. |
| 285 | Supply , installation , testing and commissioning 100A FP MCBin metal sheet enclosure with ON/OFF, RYB Indication lamps for Incoming of UPSComplete in All Respect as Required. |
| 286 | SUB HEAD VI : DISTRIBUTION PANELS |
| 287 | MAIN DISTRIBUTION PANEL - Suppy , installation, testing, Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioningof1.6/2mm CRCA sheet steel fabricated cubical type Main L.T. Panel floor mounting Extensible Type, dust & vermin proof, front operatedconstruction, enclosure class - IP 42,As per IEC 60439 after proper treatment with 9 tank process with top/bottomremovable gland plates, as required, double compression type cableglands,earth bus, hinged and lockable doorsto achieve dust and vermin proofcomplete with all inter connectionssmall wiring by min. 1.5-2.5 sq. mm. FR copper wires, ckt labels etc.The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable as required.All MCCB\"s shall be Ics = 100% Icu, with rotary handle & pad locking arrangement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified for all MCCB\"s breakers is Ics value (service rating).INCOMER: 315 AMP FP MCCBBUS BAR :400 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient Temperature.OUT GOINGS:1 No 63 AMP 4P MCB (UPS Panel)1 No 125 AMP 4P MCCB (LOWER GROUND FLOOR PANEL 1)1 No 125 AMP 4P MCCB (LOWER GROUND FLOOR PANEL 2)1 No 125 AMP 4P MCCB (GROUND FLOOR PANEL)1 No 100 AMP 4P MCCB (Lift PANEL)1 No 63 AMP 4P MCB (VENTILATION)1 No 100 AMP 4P MCCB (FIRE FIGHTING)1 No 63 AMP 4P MCB (PLUMBING)1 No 63 AMP 4P MCB (EXTERNAL LIGHTING DB)4 No 125 AMP 4P MCCB (Spare)1 No 63 AMP 4P MCB(Spare)complete panel as above and complete |
| 288 | GROUND FLOOR PANEL |
| 289 | Design, manufacture, supply, installation, testing and commissioning of Floor Mounting Distribution Panel cubicle type panel fabricated out ofCRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ completewith aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid.INCOMER:125 AMP FP MCCBBUS BAR :160 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient Temperature.OUT GOINGS:4 No 63 AMP 4P MCB (DB\"s)2 No 63 AMP 4P MCB(Spare)complete panel as above and complete |
| 290 | LOWER GROUND FLOOR PANEL 1 |
| 291 | Design, manufacture, supply, installation, testing and commissioning of Floor Mounting Panel cubicle type panel fabricated out ofCRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ completewith aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid.INCOMER:125 AMP FP MCCBBUS BAR :160 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient Temperature.OUT GOINGS:4 No 63 AMP 4P MCB (DB\"s)2 No 63 AMP 4P MCB(Spare)complete panel as above and complete |
| 292 | FIRSTFLOOR PANEL 2 |
| 293 | Design, manufacture, supply, installation, testing and commissioning of Floor Mounting Panel cubicle type panel fabricated out ofCRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ completewith aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid.INCOMER:125 AMP FP MCCBBUS BAR :160 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient Temperature.OUT GOINGS:3 No 63 AMP 4P MCB (DB\"s)3 No 63 AMP 4P MCB(Spare)complete panel as above and complete |
| 294 | UPS PANEL |
| 295 | Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out ofCRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ completewith aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid.INCOMER:1 Nos 63 AMP FP MCB (Thru Bypass Switch 10 kva UPS) Including UPS BYPASS SWITCHBUS BAR :100 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.OUT GOINGS:4 No 40 AMP 4P MCB (DB\"s)2 No 40 AMP DP MCB(SPARE)complete panel as above and complete |
| 296 | SUB HEAD VII : CABLES & ACCESSORIES |
| 297 | SUPPLY OF L.T. CABLE: |
| 298 | Supplying of Following Sizes of 1.1 KV Grade MulticoreAluminium Conductor XLPE Power Cable Insulated armoured cable conforming to IS:7098 (Part - I) or as per Relevant IS Code complete with all Amendments etcand should be NABL certified as required.3.5 C X 120 Sq.mm Al. XLPE arm. |
| 299 | 3.5 C X 50 Sq.mm Al. XLPE arm. |
| 300 | 3.5 C X 35 Sq.mm Al. XLPE arm. |
| 301 | 3.5 C X 25 Sq.mm Al. XLPE arm. |
| 302 | LT CABLE LAYING |
| 303 | Laying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV Grade of Following Size Direct in Ground Including Excavation, Sand Cushioning, Protective Covering and Refilling the Trench etc. as required.Upto 35 sq. mm |
| 304 | Above 35 sq. mm and upto 95 sq. mm |
| 305 | Above 95 sq. mm and upto 185 sq. mm |
| 306 | LT CABLE JOINTING & END TERMINATION |
| 307 | Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required.3½ X 25 sq. mm (28mm) |
| 308 | 3½ X 35 sq. mm (32mm) |
| 309 | 3½ X 50 sq. mm (35mm) |
| 310 | 3½ X 120 sq. mm (45mm) |
| 311 | SUB HEAD VIII : CABLE TRAYS |
| 312 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement)150 mm width X 50 mm depth X 1.6 mm thickness |
| 313 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 314 | SUB HEAD IX : MISCELLANEOUS ITEMS |
| 315 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 316 | SITC of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M) |
| 317 | SITC of First aid box as approved by Indian red cross conforming to IS : 2217. |
| 318 | SITC of CO2 Fire Extinguishers 4.5 kg capacity complete in all respect ISI : 15683 marked. |
| 319 | SITC of Fire Bucket stand made of M S angle suitable for and with 4 Nos Fire Buckets of 9.5 Ltrs capacity. |
| 320 | SUB HEAD X : EARTHING |
| 321 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required..(BODY EARTHING) |
| 322 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.. (NEUTRAL EARTHING) |
| 323 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 324 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 325 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 326 | SUB HEAD XI : LIGHTNING CONDUCTOR |
| 327 | Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, G.I tube, having single prong at top with 85mm dia 6mm thick G.I base plate including holes etc. complete as required. |
| 328 | Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (for horizontal run) |
| 329 | Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (for vertical run ) |
| 330 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 331 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 332 | SUB HEAD XII : EXTERNAL ELECTRIFICATION |
| 333 | Supply , Installation, Testing & Commissioning of Integrated Post Top Lantern With 40W LED Lampincluding Pole &connection with 3 x 2.5 sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. |
| 334 | Supply, Installation, Testing and Commissioning of Hybrid 28 Watt Solar Street Light luminaire with 6 Mtr Octagonal Pole & inbuilt SCC made IP65 & with MPPT (Maximum Power Point Tracking) which provides about 25% more charging efficiency by utilizing maximum energy harvested by solar PV modules. System should designed to withstand highly corrosive atmosphere and heavy wind loads. The modules are certified for industry standards IEC61215, IEC61730 (safety class 1 & 11), IEC61701 along with 6 Mtr. octagonal pole with 100 AH lead acid battery & 125 Wp solar panel Total lumen output should not less than 3100 lumen Complete with all Accessories & Control Gears etc. |
| 335 | Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing laid in ground including cost of digging upto required depth, 150 mm sand all around the cable, brick protection and back filling, clamped to wall with suitable clamps including saddles fixing bolts, Connection Testing and commissioning as Required.2x6 sqmm |
| 336 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm |
| 337 | Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing trenches/pipes, cable trays, ducts, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning as Required.2x6 sqmm |
| 338 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 339 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 core 2.5 sq.mm (for 6 Poles) |
| 340 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 341 | SUB HEAD XIII : PSS |
| 342 | 200 KVA PSS :-The 11kV Package Sub-Station shall be consisting of following HT SWITCHGEAR11kV 630Amps 21KA for 3 Sec. SF6 insulated Non-Extensible Compact switchgear (RT-2) consisting of One No. Fixed Manual Vacuum Circuit Breaker as incoming cum outgoing in SF6 insulated robotically welded stainless steel enclosure with motorised spring charge. Ingress Protection IP67, with series trip, self- powered microprocessor based numerical over current relay (IDMTL + Inst.) protection .Interconnection between HT switchgear and transformer shall be using 1Cx3x240 sq.mm Al. unarmoured XLPE CableProtection CT of ratio- 50/1A 2.5VA 5P10Mechanical position indicator. Switch ON/OFF/EARTHED.Voltage presence IndicationManometerOperating HandleHT Switchgear shall be capable for cable termination of 3C x 240 sq.mm unarmoured Al XLPE Cable.TRANSFORMER200KVA, 11KV/433V, Dyn11, 3 Phase, 50 Hz, Mineral oil filled Copper wound hermetically sealed transformer without conservator type of design & Top normal porcelain Bushings for HT & LT with on load tap changer of rating +5% to -15% @1.25% (16 step , 17 position) along with RTCC having insulation class A, Temp Rise in Oil/Winding shall be 40/45o C respectively.Losses shall be as per IS:1180 Energy Eff. Level-2Max Total Losses at 50% Loading : 1860 WattsMax Total Losses at 100% Loading : 5300 WattsImpedance: %Z - 4.5% (IS Tol.)Oil & Winding temperature indicator with alarm & trip contactsLVS PANEL - 400AMPS ALUMINUM BUSBAR433V LT Indoor panel with 400Amps Aluminium Bus bars (100% for Phase and 50% for Neutral), Fabrication using 1.5/2mm CRCA sheet steel, Ingress protection IP2X/4X, complete with internal wiring consisting of following.INCOMER FROM TRANSFORMER - 200KVA315Amps, 433V, 4P, 50Hz, 50KA, Manual Draw Out type Microprocessor base MCCB with over current, short circuit & earth fault protection.Resin Cast CT-315/5A,10VA, Accuracy CL-1.0RYB, ON-OFF-TRIP IndicationAmmeter with Selector Switch & Voltmeter with Selector Switch CL-1.0 |
| 343 | INCOMER FROM DG SET - 125KVA250Amps, 433V, 4P, 50Hz, 50KA, Motorised MCCB with over current, short circuit & earth fault protection.Resin Cast CT-400/5A,10VA, Accuracy CL-1.0RYB, ON-OFF-TRIP IndicationAmmeter with Selector Switch & Voltmeter with Selector Switch CL-1.0BUSCOUPLER315Amps, 433V, 4P, 50Hz, 50KA, Manual Draw Out type Microprocessor base ACB with over current, short circuit & earth fault protection.INTERLOCKINGElectrical Interlocking betweenincomers and bus coupler and it should have auto start and auto trip facility for Automatic Operation of The Breakers With Manual Over Rid FacilityAPFC PANEL (70KVAR)70 kVAr @440V MPP Standard Duty type capacitor bank200 Amp, 3P, 433V, 36kA Microprocessor base MCCB with O/L, S/C & E/F Protection. (APFC Incomer)OUTDOOR ENCLOSUREOutdoor type enclosure having construction of Galvanised Sheet Steel. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP34 degree of protection for Transformer compartment. The enclosure exterior shall be Powder coated (Color -RAL-1001-Cream). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment.Interconnection & EarthingInterconnection Between HT switchgear & Transformer using 1Cx3Rx240Sq.mm XLPE Al Single core cable & Interconnection between Transformers to LT switchgear using Aluminium bus bars. Internal earthing connections including Transformer Neutral by using 50x6 mm GI Strips.complete panel as above |
| 344 | SUB HEAD XIV : HT CABLE |
| 345 | HT CABLE AND ACCESSORIES Supply of H.T. CableSupply & Testing of following 11 KV( UE) grade multicore Aluminium conductor XLPE insulated cable, insulation screening withextruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required.3 C x 240 Sq. mm11 KV (UE) |
| 346 | H.T. Cable Laying-DSR ITEMH V CABLE LAYINGLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm |
| 347 | H.T Termination: DSR ITEMSupply and making Indoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV (UE) grade as required.3 C x 240 Sq.mm ( 11KV UE ) |
| 348 | Supply and making Outdoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV ( UE )grade as required.3 C x 240 Sq.mm ( 11KV UE ) |
| 349 | Supply and Making Straight Through Cable Jointing With Cast Resin Compund, Including Ferrule & Other Jointing Materials for Following Size of 3 core, XLPE Aluminium conductor cable of 11KV ( UE )grade as required.3 C x 240 Sq.mm ( 11KV UE ) |
| 350 | SH :Fire Alarm and Fire Fighting System |
| 351 | Fire Detection System - Control Panel ;Addressable fire control panel with 4/8/16 zones capacity. 24V DC power supply with battery backup. LCD display for real-time monitoring and alarm status. IP65 rated enclosure (stainless steel or powder-coated mild steel). Remote monitoring capability via GSM/Ethernet modem. Automatic dialer for emergency SMS alerts. Multi-site monitoring from central station. Compatible with addressable detectors and call points. Self-diagnostic fault display. Manual override switches for system operation. Fire alarm relay outputs for triggering sirens and suppression systems. Compliant with IS 2189:2008 Indian fire alarm standards. Dimensions: 600x500x200 mm. Installation bracket and wiring included. |
| 352 | Fire Detection System - Addressable Smoke Detectors ; Optical smoke detectors with addressable signal transmission. Coverage area: 60 sq.meters per detector. Response time: <30 seconds to visible smoke. IP65 rated housing for humidity and dust resistance. LED indicator for detector status (green normal, red alarm). Automatic sensitivity compensation for dust/dirt accumulation. Self-diagnostic capabilities with open circuit detection. 24V DC powered with integral circuit. Flush-mounted ceiling installation with minimal aesthetic impact. Test button for functional verification. Compliant with IS 3576 and European EN 54-7 standards. Detector spacing: One unit per 60 sq.m or as per zone plan. Spares: 2 extra detectors supplied for future replacement. |
| 353 | Fire Detection System - Rate-of-Rise Heat Sensors ; Thermal rate-of-rise heat detection sensors. Activation temperature: 58°C + rate-of-rise sensitivity (≥8°C per minute). Ideal for kitchens, boiler rooms, engine rooms where smoke detection unsuitable. Compensated thermistor design to account for ambient temperature. Address-based signal output for integration with fire panel. IP65 rated enclosure for harsh environments. Rapid response to fire initiation before temperature exceeds danger levels. Self-testing diagnostic capability. Response time: <30 seconds at rated temperature rise. Installation: Ceiling or wall-mounted in high-risk areas. Compliant with IS 3576 and EN 54-5 standards. Spare element: Replacement cartridges available for maintenance. |
| 354 | Fire Detection System - Manual Call Points ; Emergency break-glass manual call points for occupant-initiated alarm activation. Wall-mounted installation at height of 1.4m ±0.2m as per standards. Red colored durable ABS plastic enclosure with \"BREAK GLASS\" label in English/Hindi. Glass tube element (tempered, anti-splinter type) easy to break with minimum force. Addressable signal output to fire panel with location ID. 24V DC powered with integrated circuit. Internal sounder (85 dB) confirms button activation. Reset button with key lock to prevent unauthorized resets. Breakage counter to track actuations. Installation locations: Near stairs, exits, corridors, and high-traffic areas (minimum 1 per 500 sq.m). Compliant with IS 2189:2008 standards. Accessories: Flush/surface mounting bracket, wiring terminal block. |
| 355 | Fire Detection System - Alarm Bells & Sirens ;Electric alarm bells: 8 units of 85-90 dB audible alarm bells for zone-based distribution. Solenoid-operated vibrating bells with continuous operation capability. 24V DC powered with high-current capacity. Weather-resistant housing for indoor/outdoor installation. Flash strobe coordination available (synchronized with visual alarm). Electronic sirens: 2 units of 95-100 dB multi-tone electronic sirens for primary alarm. Pulse/wail/steady-tone modes selectable via fire panel control. 24V AC or DC powered. Compact design for aesthetic building integration. Sound pressure level: Sufficient coverage for 200 sq.m building. Strategic placement: At least 1 siren per 30 meters of building length. Bell placement: One per floor minimum. Weatherproof junction boxes for all electrical connections. Compliant with IS 2189:2008 sound output requirements. |
| 356 | Fire Suppression System - Portable Fire Extinguishers ABC Type ; 6 kg dry powder multipurpose fire extinguishers for general fires (Classes A, B, C). Suitable for paper, wood, flammable liquids, and electrical fires. Monoammonium phosphate dry powder agent: effective, non-toxic, leaves minimal residue. Effective range: 3-4 meters when properly discharged. Pressure gauge: visual indicator for charge status (green/yellow/red zones). ISI certified (IS 15683:2016 compliance) and third-party certified. Robust steel cylinder construction with corrosion-resistant coating. Safety pin and tamper seal to prevent unauthorized discharge. Mounting: Wall-mounted brackets with quick-release mechanism on all floors and key areas. Expiry: 5-year standard validity from manufacture. Service interval: Annual hydrostatic testing and refill. Accessibility: One extinguisher per 50 sq.m or per fire code requirement. Training: Pictorial usage instructions printed on each unit. |
| 357 | Fire Suppression System - Portable Fire Extinguishers CO2 Type ; 2 kg CO2 (carbon dioxide) fire extinguishers for electrical and precision equipment fires. Ideal for server rooms, control panels, electronic systems where water damage unacceptable. Non-corrosive, leaves no residue, safe for sensitive equipment. Effective range: 1-2 meters with horn delivery system. Double-wall horn construction: insulated to prevent operator hand burn from cold discharge (-78°C). Pressure gauge with color-coded zones (green normal, yellow caution, red replace). ISI certified (IS 15683:2016 compliance). Lightweight aluminum cylinder for easy handling. Safety pin and tamper seal. Mounting: Wall-mounted in server rooms, electrical panels, generator areas. Discharge nozzle: Specialized funnel design for directed CO2 application. Weight: 2-2.5 kg operational. Service interval: Annual inspection, 2-yearly hydrostatic test. Expiry: 5-year standard validity. |
| 358 | Fire Suppression System - Fire Hose Reel Assembly ; Semi-automatic fire hose reel assembly with 30 meters × 19mm diameter hose. Hose material: LSZH (Low Smoke Zero Halogen) for safety in enclosed spaces. Pressure rating: 14 bar working, 21 bar burst capacity. Reel construction: Robust mild steel or aluminum frame with corrosion-resistant coating. Manual deployment: Hose pulls out smoothly with controlled tension mechanism. Nozzle types: Detachable spray/jet combination nozzle (6-meter spray pattern in spray mode, 10-meter jet stream in jet mode). Quick-disconnect coupling: 3/4\" BSP thread for rapid connection/disconnection. Pressure gauge: In-line gauge to monitor hose pressure (0-25 bar range). Shut-off ball valve: Between reel and nozzle for flow control. Mounting: Wall-mounted or floor-standing on dedicated cabinet with instruction signage. Hose storage: Protected from UV and mechanical damage. Installation locations: Corridors, main halls, critical zones (max 30m travel to any point). Compliant with IS 3844:2015 hose reel standards. Maintenance: Annual inspection, pressure testing, hose replacement every 5-7 years. |
| 359 | Fire Suppression System - Automatic Sprinkler Heads ; Automatic fire sprinkler heads with pendent/upright orientation options. Activation temperature: 68-79°C (color-coded glass bulb for visual identification). Spray pattern: 95-110 LPM (liters per minute) at 3.5 bar operating pressure. Orifice size: 10-15mm diameter for adequate water distribution. Coverage area: 12-15 sq.meters per sprinkler head. Response time: Fast-response characteristics (<60 seconds to activation). Deflector design: Concentric rings for uniform water distribution and foam compatibility. Material: Corrosion-resistant bronze or nickel-plated brass body. Connection: 1/2\" NPT or BSP threaded inlet with removable strainer basket. Recessed installation: Flush with ceiling for aesthetic appearance. Spare elements: 2 extra bulb cartridges per 10 sprinklers for quick replacement. Compliant with IS 7439 and EN 12259 sprinkler standards. Installation: Grid pattern throughout building with calculated spacing based on hazard classification. Testing: Factory hydrostatic test at 50 bar before dispatch. |
| 360 | Fire Suppression System - Sprinkler Pipes & Fittings; GI/CPVC piping network for complete sprinkler system distribution. Total piping length: 150-180 meters covering entire building. Pipe diameter: 20mm main line, 15mm branch lines, 12mm risers (calculated per flow requirements). GI (Galvanized Iron) pipes: 3.2mm wall thickness, Class B medium pipes, 100mm cutting length. CPVC (Chlorinated Polyvinyl Chloride) option: Non-corrosive, lightweight, smooth bore for higher flow capacity. Pressure rating: 14 bar working, 21 bar hydrostatic test per IS 1239. Fittings: Brass or MS (mild steel) elbows, tees, reducers, caps, unions, ball valves. Main isolation valve: 20mm NRV (Non-Return Valve) at tank outlet with gate valve. Zone isolation: Solenoid-operated zone control valves (1-2 zones per floor). Strainer basket: 100-150 micron at main inlet to prevent pipe clogging. Vertical risers: Expansion loops every 3-4 meters to accommodate thermal expansion. Drain valve: At lowest point for periodic system flushing and maintenance. Pressure test: Entire system pressure-tested at 21 bar for 24 hours minimum. Supports: Wall clamps and hangers every 1-1.5 meters for proper pipe support. Documentation: Schematic drawing showing all connections, valve locations, and zones. |
| 361 | Fire Suppression System - Kitchen Hood Suppression System ; Wet chemical automatic suppression system for commercial kitchen hood/duct fires. System capacity: 25-40 liters of potassium acetate-based suppression agent. Activation method: Automatic via fixed thermal fusible link (60°C activation) + manual pull-down handle for override. Nitrogen pressure cartridge: Pre-charged at 10-12 bar for agent discharge. Agent delivery: Direct nozzle discharge onto cooking surface and suppression of grease fires within 5 seconds. Agent specifications: Biodegradable, non-toxic, leaves minimal residue for rapid cleanup. Cooling effect: Agent cools cooking oil below reignition temperature (>300°C). Pressure relief valve: 0.5 bar setting to prevent over-pressurization. Hose assembly: 2-3 meters stainless steel armored hose from agent cylinder to hood nozzle. Nozzle design: Wide spray pattern for even coverage of cooking area. Manual reset: After discharge, system requires manual agent cartridge replacement (not automatic reset). Mounting: Horizontal installation above cooking range, under-hood position. Visual indicators: Pressure gauge showing charge status (green/red zones). Signage: \"FIRE SUPPRESSION SYSTEM\" labels in English/Hindi with operation instructions. Compliant with IS 15105 and EN 12259-13 standards. Maintenance: Annual inspection, pressure testing, training for kitchen staff. |
| 362 | Water Supply System - Fire Water Storage Tank ; Large-capacity reinforced concrete (RCC) or mild steel (MS) underground/elevated fire water storage tank. Capacity: 100,000 liters (100 cubic meters) water storage. Tank dimensions: 10m length × 5m width × 2m height internal dimensions. RCC construction: M30 grade concrete, 300mm wall thickness, 450mm floor slab thickness, 8mm reinforcement bars (Fe500 grade) @ 150mm c/c. MS construction alternative: 6mm plate thickness for faster installation, anti-corrosion bitumen painting inside/outside. Internal baffles: 2-3 intermediate baffles for sediment settling and fuel separation (if needed for dual storage). Level indicator: Glass tube type with metal frame showing min/max levels. Magnetic float level switch: Automatic on/off signal for booster pump control. Drain valve: Bottom outlet with sediment collection chamber. Overflow outlet: Overflow pipe directed away from building with return to main tank. Inlet: 100mm main inlet with foot strainer and isolation valve. Access points: 600mm square/round access covers for internal cleaning and inspection. Earthing: Bonding lugs for electrical safety earthing (resistance <5 ohms). Foundation: 150mm RCC base, piercap walls, concrete collar for support. Ventilation: Air relief valve at top (2mm diameter) and anti-siphon valve. Labeling: \"FIRE WATER - DO NOT USE FOR OTHER PURPOSES\" signage. Hydrostatic testing: Tested at 2x working pressure for 24 hours minimum. Commissioning: Initial filling with treated water, algae inhibitor addition, pH monitoring. |
| 363 | Water Supply System - Booster Pump & Pressure Tank ; Diesel-powered booster pump system for maintaining adequate sprinkler/hose pressure throughout building. Pump specification: 150-200 LPM (liters per minute) capacity at rated speed. Head capacity: 40-50 meters equivalent pressure head (~4-5 bar). Pump type: Centrifugal self-priming pump with mechanical seal. Engine: 4-stroke diesel engine, 10-12 kW power, single-cylinder or twin-cylinder, 1500 RPM. Fuel tank: Internal 20-50 liters diesel capacity for 4-6 hours continuous operation. Hydro-pneumatic pressure tank: 500 liters capacity for pressure stabilization and intermittent supply. Pre-charge pressure: 0.9x operating pressure (typically 1.8 bar for 2 bar operating). Pressure switch: Automatic on/off at 1.5-2.5 bar differential for pump start/stop control. Relief valve: Pressure relief at 3.5 bar to prevent over-pressurization. Check valve: Non-return valve at pump discharge to prevent backflow. Pressure gauge: Visual gauge (0-5 bar range) for operator monitoring. Flow meter: Optional digital flow meter for system monitoring. Auto start capability: Optional for remote monitoring and automatic activation in fire event. Vibration isolators: Rubber mounts for pump-engine assembly to reduce noise. Noise attenuation: Silencer on engine exhaust. Service access: Easy access to fuel inlet, oil dipstick, drain valve for maintenance. Installation: Elevated platform or ground-level with anti-vibration base. Suction line: Low-friction hose from water tank with strainer foot valve. Discharge line: Pressure hose to sprinkler/hose system with pressure gauge. Commissioning: Load test for 2 hours, pressure/flow verification, operator training. Annual maintenance: Oil change, fuel filter replacement, mechanical seal inspection. |
| 364 | Installation & Commissioning - Installation Services & Labor ; Complete professional installation of fire safety system across building. Scope includes: Site preparation (area clearance, marking), excavation for underground tank (if applicable), piping layout and routing through walls/ceiling/floors, sprinkler head installation and positioning per code, hose reel mounting and testing, control panel electrical wiring and integration, booster pump installation and alignment, water tank construction/assembly, pressure testing (hydrostatic test at 1.5x working pressure), flow testing at all zones/sprinklers, FAT (Factory Acceptance Testing) of pump system, commissioning of entire system with dummy load testing. Labor force: Qualified engineers (2-3 senior technicians) + skilled workers (5-8 laborers) + electricians (2-3). Duration: 15-20 working days depending on building complexity and system scope. Equipment staging: Temporary power supply, site lighting, safety barriers, material storage. Quality checks: Pressure testing certificates, flow rate verification, noise level measurement, electrical safety tests (megger test, voltage verification). Documentation: As-built schematic drawings, test certificates, commissioning report, system operating manual. Staff training: 8-10 hour training sessions for building maintenance staff (2 batches minimum) covering system operation, emergency procedures, maintenance schedule, troubleshooting. Training manual: Printed manuals in English/Hindi with system diagrams. Final handover: Signed commissioning certificate and warranty activation. |
| 365 | Documentation & Miscellaneous - Miscellaneous Items & Documentation; Comprehensive documentation and miscellaneous safety items for fire system. Documentation includes: Technical manuals (300+ pages) covering system design, operation procedures, maintenance schedule, emergency procedures, contact details. Schematic drawings: Detailed fire system layout, sprinkler head positioning, hose reel locations, tank connections, electrical wiring, pump curve data. Test certificates: Pressure test report, flow test documentation, electrical safety test (megger report), noise verification, hydrostatic test certificates. Warranty documentation: Manufacturer warranty cards for all equipment, extended warranty options. Service record logbook: 50-page bound logbook for maintenance records, monthly inspections, annual servicing, parts replacement history. Safety signage: \"FIRE DETECTION SYSTEM\", \"EMERGENCY ASSEMBLY POINT\", \"DO NOT OBSTRUCT\", \"BREAK GLASS ALARM\" signs in English/Hindi (laminated A3/A4 size). Safety equipment: Fire blanket (1-2 units), emergency contact numbers poster (laminated), evacuation route plan (A3 size mounted at key locations), first aid kit. Tools & spares: Fire extinguisher pressure test gauge, hose wrench, system bleed valve key, spare fuses (5-10 units), replacement valve stems, hose washers, connector plugs. Consumables: Dry powder refill cartridges (2-3 units), CO2 cartridges (1-2 units), lubricating grease for valves, hydraulic oil for pressure switches. Electrical safety: Cable glands (assorted 20-30 units), terminal blocks, cable markers, warning labels (\"HIGH VOLTAGE\", \"NO SMOKING\"). Desiccant packets: Silica gel for control panel to prevent moisture accumulation. Fire system access covers: Plastic covers for hose reel storage, pump equipment, tank access points. |
| 366 | Specialized Systems - Restaurant Kitchen Hose System ; Specialized fire suppression hose system . Hose specifications: 50 meters total length of LSZH (Low Smoke Zero Halogen) hose (19mm diameter). Semi-automatic hose reels: 2 units wall-mounted reels with quick-deploy mechanism. Hydrant connection points: 3 strategically located hydrant points (3/4\" BSP thread). Hydrant valve boxes: Stainless steel recessed boxes at each location (500x500x200mm). Spray/jet combination nozzles: 3 interchangeable nozzles (spray mode 6m range, jet mode 10m range) with quick-couplers. Quick-disconnect brass couplers: 3/4\" BSP at each hydrant point for rapid hose connection. Pressure gauge: In-line gauge (0-10 bar) for operational monitoring. Flow control valve: Ball valve at each hydrant for flow regulation. Signage: Bilingual (English/Hindi) identification signs at each hydrant location. Installation features: Hose routing under false ceiling/wall conduits for aesthetic appearance, Protected from mechanical damage with cable trays, Proper slope for drainage when not in use, Support clamps every 1.5 meters. Pressure testing: Entire hose system hydrostatic tested at 21 bar for 24 hours. Commissioning: Flow test at each point, pressure drop verification, staff training for kitchen operation. Maintenance: Annual visual inspection, 5-yearly pressure testing, hose replacement every 10 years or on damage. |
| 367 | Specialized Systems - Museum Display Area Hose System (Anjaw) ; Specialized ultra-sensitive fire hose system for museum artifact display areas in Anjaw project with water damage minimization. Hose specifications: 60 meters total length of LSZH (Low Smoke Zero Halogen) hose (12mm diameter - reduced bore for controlled discharge). Semi-automatic hose reels: 2 units mounted in discrete cabinetry to match museum aesthetics. Hydrant connection points: 5 color-coded hydrant points (1/2\" BSP thread) at strategic locations throughout display halls. Hydrant valve boxes: Stainless steel or powder-coated boxes with aesthetic design (400x400x180mm). Ultra-fine mist nozzles: 5 specialized nozzles producing fine water mist spray (2-3 bar operating pressure) minimizing artifact damage while providing fire suppression coverage. Temperature-monitoring nozzles: Some nozzles equipped with thermal sensors to activate only in high-temperature fire zones. Flow metering: Pressure-reducing valves (PRV) set at 2.5-3 bar to limit water discharge volume (~30-40 LPM) compared to standard 100+ LPM. Quick-disconnect brass couplers: 1/2\" BSP at each hydrant with color-coded sleeves (red for fire use only). Stainless steel fittings: All connections in marine-grade stainless steel to resist corrosion in climate-controlled museum environment. Pressure gauge: Analog gauge with digital backup (0-5 bar range) at main supply. Flow control valve: Needle valve for precise flow adjustment at each point. Signage: Bilingual \"DISPLAY AREA - FIRE HOSE (MINIMAL WATER USE)\" signs. Installation features: Hidden routing through artifact-free corridors, Below-floor conduit installation to avoid visual obstruction, Discrete hydrant cabinetry matching museum interior design, Hose storage in moisture-resistant covers. Pressure testing: System pressure tested at 15 bar (below artifact damage threshold). Commissioning: Low-pressure flow test, nozzle spray pattern verification, museum staff demonstration (curators and security). Maintenance protocol: Quarterly visual inspection (no flow testing to minimize moisture), Annual pressure check (low-pressure only), Hose replacement every 12-15 years due to climate control environment. |
| 368 | SH:Furnishing of Essential Furniture. |
| 369 | Sofa Set: Supplying and placing factory‑made premium sofa set comprising one 3‑seater and two single‑seater sofas, internal frame of kiln‑dried hardwood with corner blocks, seat and back in high‑density polyurethane foam (minimum 32–40 kg/m³ for seat, 25–28 kg/m³ for back), no‑sag zig‑zag springs or webbing support, upholstered in commercial‑grade stain‑resistant fabric / genuine leatherette, with double‑stitched seams, ergonomic backrest, and polished solid‑wood / powder‑coated metal legs, including all accessories, complete |
| 370 | Coffee Table: Supplying, installation, testing and commissioning of 1.5 TR wall‑mounted split air conditioner, 5‑star inverter type, complete with indoor and outdoor units, copper refrigerant piping with insulation, drain pipe, mounting brackets, interconnecting wiring, initial gas charge and standard installation, of approved make (Daikin / Blue Star / Voltas / LG / Hitachi or equivalent), complete |
| 371 | Supplying and placing mid‑back revolving office chair with wheels, ergonomic design, moulded foam seat with fabric/mesh upholstery, breathable mesh or cushioned back with lumbar support, pneumatic gas‑lift height adjustment, synchro‑tilt mechanism with lock, fixed or adjustable armrests, mounted on 5‑prong nylon/metal base with twin‑wheel castors, complete as per direction of Engineer‑in‑Charge |
| 372 | Steel Almirah: Supplying, placing, and installing factory‑made steel almirah, full height approx. 1980 mm (H) × 900–965 mm (W) × 450–610 mm (D), double‑leaf swing doors, fabricated from prime quality CRCA steel sheet of minimum 0.8–0.9 mm thickness for body, doors and shelves, with fully welded construction, four adjustable shelves (5 compartments), integrated locker with separate lock, three‑way locking mechanism, ventilating slots, plastic buffers, and 7‑lever Godrej‑type lock with two keys, complete with epoxy‑polyester powder‑coated finish of minimum 40–50 microns in approved shade, including all handling and positioning. |
| 373 | Reverse Osmosis (RO) water purifier, 25 LPHDescription: “Supplying, installation, testing and commissioning of wall‑mount / counter‑top RO water purifier of minimum 25 litres per hour purification capacity, suitable for raw water TDS up to 1500–2000 ppm, max duty cycle about 150–200 litres per day, complete with multi‑stage purification (sediment filter, activated carbon filter, RO membrane, post‑carbon / taste conditioner; minimum 5–6 stages), built‑in booster pump, automatic flush, food‑grade piping, mounting brackets and connections to existing water supply and drain, including all taxes, labour and commissioning, complete as directed by Engineer‑in‑Charge.” |
| 374 | Split Air Conditioner: Supplying, installation, testing and commissioning of 2 TR wall‑mounted split air conditioner, 5‑star inverter type, complete with indoor and outdoor units, copper refrigerant piping with insulation, drain pipe, mounting brackets, interconnecting wiring, initial gas charge and standard installation, of approved make (Daikin / Blue Star / Voltas / LG / Hitachi or equivalent), complete |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail