Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of Cement concrete in ground floors and pavings n.exc 15 cm thickness below or above ground level) and removing debris out of MOD land. Complete all as specified and directed by Engr-in-charges. |
| 2 | Demolition of Cement concrete (including cutting of reinforcement if any) in any description and any position not otherwise specifically provided for and removing debris out of MOD land. Complete all as specified and directed by Engr-in-charges. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises Complete all as specified and directed by Engr-in-charges. |
| 4 | M&L for 18-20mm thick Udaipur green marble machine cut in washbasin platform laid over 10mm thick screed bed in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including polishing and rounding the edges Complete all as specified and directed by Engr-in-charges. |
| 5 | M&L for 25 mm thick cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) to receive floor finishes etc Complete all as specified and directed by Engr-in-charges. |
| 6 | M&L for ceramic colour tiles in vertical surface of size 350 X 250 x 7/450x300x7 mm thick, jointless type, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with and including 10 mm thick rendering in CM (1:4) for receiving the tiles, Complete all as specified and directed by Engr-in-charges. |
| 7 | M&L of 18-20mm thick machine cut KOTA stone slab as in floor (size not less than 580mm x 580mm) , treads, steps etc(Single piece for steps), machine cut, laid over cementand jointed with grey cement slurry with pigment to match the shade of the slab, incl rubbing and Mirrorpolishing all as specified as in floors over and including 15mm thick in screed bed in CM (1:6). Complete all as specified and directed by Engr-in-charges. |
| 8 | M&L of 18-20mm thick machine cut KOTA stone slab riser of step , skirting, dado etc(Single piece for steps), machine cut, laid over cementand jointed with grey cement slurry with pigment to match the shade of the slab, incl rubbing and Mirrorpolishing all as specified including backing coat of 10mm thick in CM (1:4). Complete all as specified and directed by Engr-in-charges. |
| 9 | M&L for non skid coloured ceramic tiles 6 to 8 mm thick ( square, rectangular ) area of each tiles exc 0.11 sqm but n exc 0.18sqm as per IS 13712 Grade II(a) , in floor etc overand including 15mm thick screed bed in CM (1:6) Complete all as specified and directed by Engr-in-charges. |
| 10 | Taking down cement plaster on stone masonry RCC surfaces, dado surfaces etc completeincl racking out joints, hacking for key scrubbing down with water Complete all as specified and directed by Engr-in-charges. |
| 11 | M&L for 15mm thick rendering in CM 1:6 on stone masonry finished even and smooth without using extra cement Complete all as specified and directed by Engr-in-charges. |
| 12 | M&L Rendering 10 mm thick in CM (1:4) on concrete surfaces on ceiling / facia /RCC Chhaja etc all as directed & finished even & smooth without using extra cement Complete all as specified and directed by Engr-in-charges. |
| 13 | Raking out joints/pointing to square rubble masonryJodhpur type regular coursed built in cement mortar Complete all as specified and directed by Engr-in-charges. |
| 14 | M&L for Keyed pointing to square rubble masonryJodhpur type regular course in CM 1:3 Complete all as specified and directed by Engr-in-charges. |
| 15 | M&L for preparation of new plastered surface and applying two coats of oil bound distemper, over and incl a layer of primer with1mm thick wall care putty to get even and smooth level finish on new plastered surface Complete all as specified and directed by Engr-in-charges. |
| 16 | M&L for three coats of white wash including preparation of new surfaces as on ceilings Complete all as specified and directed by Engr-in-charges. |
| 17 | M&L for one coat of white wash including preparation of old surfaces as on ceilings Complete all as specified and directed by Engr-in-charges. |
| 18 | M/L two coat of cement based paint on old plastered/ unplastered surfacesincluding preparation Complete all as specified and directed by Engr-in-charges. |
| 19 | M/L two coat of cement based paint on new plastered/ unplastered surfacesincluding preparation Complete all as specified and directed by Engr-in-charges. |
| 20 | Taking down chowkat with shutters (without taking off shutter from frame) size area n.exc1.50 sqm each Complete all as specified and directed by Engr-in-charges. |
| 21 | Taking down chowkat with shutters (without taking off shutter from frame) size area exc 1.5sqm but n.exc4.0 sqm each Complete all as specified and directed by Engr-in-charges. |
| 22 | S&F PVC door frame wooden finish of size 50mmx 47mm made out of 5mm plain color PVC sheet reinforced with MS square tube. Complete all as specified and directed by Engr-in-charges. |
| 23 | M/L for PCC 1:2:4 type B1 Mix using 20mm graded stone aggregate as in bed block for hold fast , filling in frame including necessary form work Complete all as specified and directed by Engr-in-charges. |
| 24 | Taking down of steel window and ventilators Complete all as specified and directed by Engr-in-charges. |
| 25 | S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete with glazing bars and cooler opening , dovetailed or welded. Complete all as specified and directed by Engr-in-charges.Note.1 :Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same. Note 2: Glazing, guard bar wire cloth & painting will be measured & paid separately |
| 26 | S&F of Box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete with glazing bars,Note : Glazing, guard bar wire cloth & painting will be measured & paid separately Complete all as specified and directed by Engr-in-charges. |
| 27 | S&F of Box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete without glazing bars, Note : Glazing, guard bar wire cloth & painting will be measured & paid separately Complete all as specified and directed by Engr-in-charges. |
| 28 | S&F of Mild steel guard bars, grills, grating, and similar work and welded to window frames, door frames (made up of angle), balcony railing confirming to FE 290, gde E-165 etc Complete all as specified and directed by Engr-in-charges. |
| 29 | S&F galvanised mild steel wire cloth 0.56mmnominal dia of wire and average width ofaperature 1.18 mm. Complete all as specified and directed by Engr-in-charges. |
| 30 | S&F factory made PVC shutter 30 mm thick (style)consisting of frame made out of MS tube for top and bottom rails. MS frmae shall be covered with heat moulded plain color PVC channel having a PVC sheet for top rail of 20mm width width stuck in side with solvent cement for stiles and plain color PVC sheet for top rail lock rail on other side and as gap insert for top rail and bottom rail. Paneling of plain color PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and jointed together with slovent cement Complete all as specified and directed by Engr-in-charges. |
| 31 | M & L for pressed steel door frames (105X60 mm)for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates, PCC etc, Complete all as specified and directed by Engr-in-charges. |
| 32 | M & L for pressed steel door frames (165X60 mm)for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates, PCC etc, Complete all as specified and directed by Engr-in-charges. |
| 33 | M&L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides if one face is covered with decorative face veneer with lipping/frame to match Complete all as specified and directed by Engr-in-charges. |
| 34 | S & F 35mm thick factory made second class hardwood glazed and Skelton door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009section 8 clause 8.24 (a) and Complete all as specified and directed by Engr-in-charges. |
| 35 | S &F of Stainless steel butt hinges medium weight, cold rolled of size 100 mm size. Complete all as specified and directed by Engr-in-charges. |
| 36 | S &F of mild steel butt hinges medium weight, cold rolled of size 100 mm size. Complete all as specified and directed by Engr-in-charges. |
| 37 | S&F of mild steel barrel tower bolt 200 mm long stove enamelled black with bright bolt Complete all as specified and directed by Engr-in-charges. |
| 38 | S&F Mild steel pressed handles 150mm size, oval type, stove enamelled black, pattern and design as approved by Engr-in-charge. Complete all as specified and directed by Engr-in-charges. |
| 39 | S&F of mild steel sliding door bolt 300 mm long stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on stapple plate. Complete all as specified and directed by Engr-in-charges. |
| 40 | Hacking out old broken glass (any thickness , size , quality or description ) from metal frame incld punching or drilling out old glazing pins /spring clipsand provding and fixing new ones. Complete all as specified and directed by Engr-in-charges. |
| 41 | S&F for3 mm thick plain sheet glass ordinary quality & glazingwith oil putty in square n exc 0.50sqm ineach pane. Complete all as specified and directed by Engr-in-charges. |
| 42 | S&F for4 mm thick figurred , pin headed glass ordinary quality & glazingwith oil putty in square n exc 0.50sqm ineach pane. Complete all as specified and directed by Engr-in-charges. |
| 43 | M & L for prep of the new surfaces of steel & applying two coats of syn enamel paint over one coat of red oxide primer over 10Cm width or girth Complete all as specified and directed by Engr-in-charges. |
| 44 | M/L for two coat of synthetic enamel paint on new wooden surface including preparation of surface, over 10Cm width or girth Complete all as specified and directed by Engr-in-charges. |
| 45 | Taking up or down GI steel /CPVC water tubing 15 mm bore and connection, including cleaning for refixing or remove to site. Complete all as specified and directed by Engr-in-charges. |
| 46 | Taking up or down GI tubing/CPVC 20/25 mm bore and connection, including cleaning for refixing or remove to site. Complete all as specified and directed by Engr-in-charges. |
| 47 | Supply, laying, testing & commissioning of20 mm outer dia CPVC pipe,SDR-11, with all fitting (eblow, socket,tee with internal thread of brass) fixed to wall, ceiling or laid on floor, with CPVC solvent, complete all as specified and as directed by Engr-in-Charge. |
| 48 | Supply, laying, testing & commissioning of25 mm outer dia CPVC pipe,SDR-11, with all fitting (eblow, socket,tee with internal thread of brass) fixed to wall, ceiling or laid on floor, with CPVC solvent, complete all as specified and as directed by Engr-in-Charge. |
| 49 | M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 10 cmand nexc 20 cm girth, complete all as specified and as directed by Engr-in-Charge. Complete all as specified and directed by Engr-in-charges. |
| 50 | S&F in repair of bib cock 15mm dia, chromium plated copper alloy fancy type, screwed for iron pipe or for brass ferrule Complete all as specified and directed by Engr-in-charges. |
| 51 | S&F in repair Fancy type Chromium plated shower roses 125mm size with arm, with or without swivel joints, 15mm bore, including fixing to steel pipe or union. Complete all as specified and directed by Engr-in-charges. |
| 52 | S&F in repairs angular stop valves cast copper alloy chromium plated(ISI marked) screwed down high pressure fancy type screwed both ends for 15mm bore of iron pipe or union Complete all as specified and directed by Engr-in-charges. |
| 53 | S&F stop valves cast copper alloy (ISI marked) CP screwed down high pressure with crutch or butterfly handle screwed both ends for 20mm bore of iron pipe or union and fixed in repair Complete all as specified and directed by Engr-in-charges. |
| 54 | S&F Pillar taps 15mm bore , cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe. Complete all as specified and directed by Engr-in-charges. |
| 55 | S&F 600mmx450mm bevelled edge mirror of selected quality glass 5.5 mm thick, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers Complete all as specified and directed by Engr-in-charges. |
| 56 | M&L for 75mm outlet diameter UPVC nahani trap, with CP Mild steel grating (with or without hole) including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) using 20mm graded stone aggregate. Complete all as specified and directed by Engr-in-charges. |
| 57 | S&F tubular towel rail 20mm dia brass chromium plated `D\" type 60cm long with bracket and fixed Complete all as specified and directed by Engr-in-charges. |
| 58 | S&F in repairs decorative type curtain rod stainless steel finishofpipe 22 to 25 mm diawith best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs Complete all as specified and directed by Engr-in-charges. |
| 59 | M&L for 7.5CM thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:3 or cement mortar 1:4, Complete all as specified and directed by Engr-in-charges. |
| 60 | S&F of Vitreous China wash basin size 450 x 300mm with padestal, white, flat back, including CP waste coupling, waste pipe, PVC Connection 300 mm long, brackets Complete all as specified and directed by Engr-in-charges. |
| 61 | S&Fin repair vitreous china squatting Pan, Orissa Pattern of size 580X440mm white with integral foot rests and cast iron `P\" or `S\" trap front or back fixed in repairs Including connection to trap etc and provision of cement concrete bedding and making good to floor Complete all as specified and directed by Engr-in-charges. |
| 62 | S&F in repair vitreous ware wash down water closet [Pedestal Pattern], white [ETWC]including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and \"P\" or \"S\" trap connecting to drain pipe and flushing pipe etc.,& provision of cement concrete making good to as existing floor, complete all as specified and as directed by Engr-in-Charge. |
| 63 | Dismantaling of cast iron/pvc soil waste & vent pipes 100/110 mm dia incl all fittings etc Complete all as specified and directed by Engr-in-charges. |
| 64 | Dismantaling of cast iron/pvc soil waste & vent pipes 75 mm dia incl all fittings etc Complete all as specified and directed by Engr-in-charges. |
| 65 | Supplying and laying of 75 mm dia UPVC pipes SWR& Plain UPVC SDR 11 fittings in trenches Complete all as specified and directed by Engr-in-charges. |
| 66 | Supplying and laying of 110 mm dia UPVC pipes SWR& Plain UPVC SDR 11 fittings in trenches Complete all as specified and directed by Engr-in-charges. |
| 67 | Supplying and laying of 75 mm dia UPVC pipes SWR fittings on walls / ceiling or laying in floors Complete all as specified and directed by Engr-in-charges. |
| 68 | Supplying and laying of 110 mm dia CPVC pipes SWR fittings on walls / ceiling or laying in floors Complete all as specified and directed by Engr-in-charges. |
| 69 | S&F 75 mm bore UPVC bends any radius with oval acess door Complete all as specified and directed by Engr-in-charges. |
| 70 | S&F 110 mm bore UPVCbends any radius with oval acess door Complete all as specified and directed by Engr-in-charges. |
| 71 | S&F for 100mm dia UPVC cowls, diminishing pieces or tapers (larger bore measured) Complete all as specified and directed by Engr-in-charges. |
| 72 | Supply and fixing in repair PVC valve less symphonic action type flushing cistern 10 ltrs capacity low level with inlet, ball valve, float and handle Including bracket fixed and Complete all as specified and directed by Engr-in-charges. |
| 73 | S&F 32mm bore low or high density polyethylene waste pipes (LDPE) of pressure rating 6Kg/Sqm fixed complete to walls, ceiling or floors etc Complete all as specified and directed by Engr-in-charges. |
| 74 | S&F in repair 15mm bore PVC connection (for Flushing cistern & HWB) 600mm long best qualitywith PTMT nuts Complete all as specified and directed by Engr-in-charges. |
| 75 | M&L 40 mm thickPCC (1:2:4) type B1 using 20mm graded stone aggregate as in floor , hard standing flooring finished even and smooth without using extra cement Complete all as specified and directed by Engr-in-charges. |
| 76 | M&L for25 mm thick Sand stone slabs in plinth protection, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointedcement mortar 1:4 over 15mm thick screed bed in CM 1:6 over and including PCC (1:3:6) type C2, (using20mm graded stone aggregate) as in plinth protection, 50 mm thick, finishing the surface even and fair Complete all as specified and directed by Engr-in-charges. |
| 77 | Taking down of existing damaged / loosened cement concrete/ brick tiles from roof / terrace to a depth of average 50 mm including taking down of existing APP membrance if any , cleaning with water and depositing of debris to a distance not exceeding 50m Complete all as specified and directed by Engr-in-charges. |
| 78 | M&L for carrying out water proofing treatment forroofs in the following stages -(i) Rendering 15 mm thick in 1:4 mixed with integral water proofing liquid all as per manufacturer\"s instructions over concrete surfaces finished even and smooth with using extra cement. (ii)First coat of bitumen primer confirming to IS 3384 @0.300 Kg/ Sqm over plastered surafces(iii)Secondlayer of 3.0 mm thick APP modified polymeric membrane with centre core of Single non woven polyster reinforcementandhaving weight 3 Kg/ Sqm with mineral gravel finish on top complete laid with blown type bitumen grade 85/25 @ 1.20 Kg/ Sqm Complete all as specified and directed by Engr-in-charges.Note- WPC shall be measured and paid separately. |
| 79 | M&L for PCC 1:2:4 Type B-0 (using 12.5mm graded stone aggregate ) average 40mm thick, well compacted with \"V\" shaped groove of 10 mm deep filled with mastic bitumen. Size of PCC panel with groove shall not exceeding 0.40 Sqm Complete all as specified and directed by Engr-in-charges. |
| 80 | Dismantling existing water tank of capacity not exc 1000ltrs and removing from site. Complete all as specified and directed by Engr-in-charges. |
| 81 | S&F rotational moulded polyethylene water storage tank ISI Marked (cylindrical vertical with closed top) white, hoisted and fixed in position all as directed of capacity 1000 ltrs a Including 20mm bore brass ball valve high pressure with polythene float Complete all as specified and directed by Engr-in-charges. |
| 82 | Supply only integral water proofing compound (ISI marked). Complete all as specified and directed by Engr-in-charges. |
| 83 | Demolition of stone masonry /block walling built in cement mortar Complete all as specified and directed by Engr-in-charges. |
| 84 | M&L for squarred rubble walling Jodhpur type regular coursed well bonded, bedded and solidly hearted built in cement mortar 1:6 Complete all as specified and directed by Engr-in-charges. |
| 85 | M&L for precast cement concrete solid building blocks type B1 1:2:4 (20mm graded stone aggregate) or slabs 10cm thick (with plain or interlocking joints as directed) setting in 1:4 cement mortar, Complete all as specified and directed by Engr-in-charges. |
| 86 | M&L for providing precast cement concrete type B-1 1:2:4 (using 20mm graded stone agg) as in kerb stone etc (of any section as approved) with plain faces , including chamfers,weathering, throating etc and setting in cement mortar 1:4 Complete all as specified and directed by Engr-in-charges. |
| 87 | M&L 75 mm thick PCC (1:4:8) type D2 using 40mm gradded stone aggregate as in sub base. Complete all as specified and directed by Engr-in-charges. |
| 88 | M&L for 25mm thick Sand filling to be used as a cushion under paver block. Complete all as specified and directed by Engr-in-charges. |
| 89 | S&F machine made precast cement concrete blocks (interlocking paves) colour rubberised 60mm thick with 6mm top layers of anti abrasive material Comforming to IS 15658-2006 of M-35 grade. The interlocking joints shall be filled with fine sand . Complete all as specified and directed by Engr-in-charges. |
| 90 | Taking down carefully cement conc /spalled out concrete fromRCC roof projections, ceiling ,sunsheds, chajja, beams, etc upto cover depth by chipping out lightly including necessary scafolding etc Complete all as specified and directed by Engr-in-charges. |
| 91 | M&L for fixing TMT bars 10mm dia & over by way of stitching ( welding ot tieing with existing reinf) incl drilling holes etc & securing ends in walls etc Complete all as specified and directed by Engr-in-charges. |
| 92 | M&L for cleaning the existingreinf of slabs , chajjas etc& applying a coat of SIKA RUSTOFF 11 to remove the loose rust particles etc & throughly cleaning the surface. Complete all as specified and directed by Engr-in-charges. |
| 93 | M&L for applying a coat of bond coat made with cement slurry(1 part cement to 1.5 -2 parts water)mixed with admixtureLATEX POWERmixed @5 Kg per 50 kgof cement & applying to the conc surfaces @ 200 gm/sqm to obtain tack. Complete all as specified and directed by Engr-in-charges. |
| 94 | M&L for 15 -20 mm thick rendering in CM 1:1:2 using1 part of cement 1 part 2-3 mm screenings of stone agg & 2 parts coarse sandof over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPERadmixture @ 100 gm /50kg of cement & finishing the surface even & rough to receive final rendering coat. Complete all as specified and directed by Engr-in-charges. |
| 95 | M&L for 5 mm thick rendering in CM 1:3 on ceiling & finishing the surface even & smooth w/o using extra cement Complete all as specified and directed by Engr-in-charges. |
| 96 | M&L for 10-15 mm thick rendering in CM 1:3 over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPERadmixture @ 100 gm /50kg of cement & finishing the surface even & smooth Complete all as specified and directed by Engr-in-charges. |
| 97 | S&F GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/fascias, wall, ceiling etc. Complete all as specified and directed by Engr-in-charges. |
| 98 | S&F MS chromium plated peg set of five fixing with wall Complete all as specified and directed by Engr-in-charges. |
| 99 | M&L for making of Number Plaque (diamond square 30cmx30cmx20mm thick plaster plaque in CM 1:3 finished smooth using extra cement duly painted in three coats of black synthetic enamel paint including priming coat) including takingdown existing plastered number plaque Complete all as specified and directed by Engr-in-charges. |
| 100 | M&L for Forming letters, figures etc. by cutting \"V\" grooves in new lime, cement plaster (each of 12cm of height) Complete all as specified and directed by Engr-in-charges. |
| 101 | M&L for Writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high Complete all as specified and directed by Engr-in-charges. |
| 102 | Excavation in trenches not exc 1.50m wide and not exc 1.50m depth and getting out in soft/loose soil ext complete all as specified and directed by Engr -in- Charge. |
| 103 | M&L for salt glazed stoneware drain pipes 150mm dia (internal) grade \"A\" laid in trenches and jointed in CM(1:1) including taking down old u/s pipe Complete all as specified and directed by Engr-in-charges. |
| 104 | S&F Reinforced concrete pipes of 150mm dia, class NP2, laid and jointed complete with collars Complete all as specified and directed by Engr-in-charges. |
| 105 | M&L for cement concret (1:3:6) type C-2, using 40mm graded stone aggregate bed to drain pipe 150 mm dia including packing under and haunching against the pipe after they are laid including necessary formwork Complete all as specified and directed by Engr-in-charges. |
| 106 | Returning, filing in including, levelling,watering and well ramming in layers not exc 25cm thick each Complete all as specified and directed by Engr-in-charges. |
| 107 | Removing excavated material to a distance not exc 50m depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engr -in- Charge. |
| 108 | Removing of existing filling in sunken floor of wc/bath/kitchen and repair to sunken floor with 15 mm thick plastering in CM 1:3 of internal surface with PC than painting with bitumen 30/40 over a coat of bitumen primer putting 50 micron polythene than filling with pcc 1:5:10type E-1 using 40mm graded stone aggregate and inserting 50 mm bore GI water pipe light grade spout Complete all as specified and directed by Engr-in-charges. |
| 109 | M&L for PCC 1:3:6 type C1 using 20 mm graded stone agg as in filling under pressed steel door frames & hold fasy blocks etc Complete all as specified and directed by Engr-in-charges. |
| 110 | S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor Complete all as specified and directed by Engr-in-charges. |
| 111 | S&F PVC door seal fixed at door to cover the gap between floor and door Complete all as specified and directed by Engr-in-charges. |
| 112 | M&L for MS Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 Complete all as specified and directed by Engr-in-charges. |
| 113 | Taking down carefully aluminum/copper point wiring (light/fan/ socket/ power) complete including fittings such as switch, socket, ceiling roses light fittings etc andand making good disturbed surface of wall Complete all as specified and directed by Engr-in-charges. |
| 114 | Taking down carefully UNSV main switch and DB\"s including MCBs of any size make, type and capacity and depositing Complete all as specified and directed by Engr-in-charges. |
| 115 | M&L for point wiring complete for one light point /fan point / bell point controlled by one 1-way switch/ bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, Complete all as specified and directed by Engr-in-charges. |
| 116 | All as per srl item No. 115 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board. Complete all as specified and directed by Engr-in-charges. |
| 117 | All as per srl item No. 115 here-in-before but for one socket outlet 3 pin, 5 Amps on same board. Complete all as specified and directed by Engr-in-charges. |
| 118 | All as per srl item No. 115 here-in-before but with 4 sq mmFRLS copper wire with 4 Sqmm FRLS copper earth wire for 3 pin socket 15 amp independent or other suitable pointComplete all as specified and directed by Engr-in-charges. |
| 119 | All as per item No 115 above but one light point controlled by two 2-way switches complete all as specified and directed by Engineer-in-charge. |
| 120 | S&F in replacement Modular switch 6 Ampsone way 240 V Complete all as specified and directed by Engr-in-charges. |
| 121 | S&F in replacement Modular switch 16 Ampsone way 240 V Complete all as specified and directed by Engr-in-charges. |
| 122 | S&Fin replacement Modular socket out let 2/3 pin combined 6 Amps 2 module Complete all as specified and directed by Engr-in-charges. |
| 123 | S&Fin replacement Modular socket outlet in repair 2/3 pin, 6/16 Amps socket outlet 240 volts 2 module Complete all as specified and directed by Engr-in-charges. |
| 124 | S&F in replacement Modular switch 6 Amps2 way 240 V Complete all as specified and directed by Engr-in-charges. |
| 125 | S& F Modular type regulator 2 module A/C 240 Volts Complete all as specified and directed by Engr-in-charges. |
| 126 | S&F of Ceiling rose, two to three terminals, bakelite body, 230 volts, Complete all as specified and directed by Engr-in-charges. |
| 127 | S & F in replacement Lamp holder, PVC/Polycarbonate type with 12 watt LED Bulb andback plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge. |
| 128 | S&F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size Complete all as specified and directed by Engr-in-charges. |
| 129 | S&F in replacement of LED light fitting 1 X 20/22 watt (4 feet), decorative ultra slim type, with inegral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, Complete all as specified and directed by Engr-in-charges. |
| 130 | S&F in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection Complete all as specified and directed by Engr-in-charges. Note:-The cost supplying and fixingiron bracket 32 mm bore with necessary nut bols ,clamp etcis included in quoted rate. |
| 131 | Taking downexhaust fan, steel body/ PVC Body AC single Phase. 230V of size 250/300m sweep with, blades, and frame and louvers and keep in safe custody for refix after complete of work by making all necessary connection. Complete all as specified and directed by Engr-in-charges. |
| 132 | Taking down and refixing the Ceiling fan after repair work (i.e celaning, oiling, greasing, blade leveling etc) complete with down rod and 3 core 1.5 sg mm copper conductor cable from ceilingrose to fan complete with all accessoriesComplete all as specified and directed by Engr-in-charges. |
| 133 | S&F in replacement Single poleenclosure with a two pin and earth plug and socket complete 240V with one single pole MCB 20 \"C-curve ampComplete all as specified and directed by Engr-in-charges. |
| 134 | S&F in replacement MCCBDB\"s Vertical TPN (Vertical DB) 4 way, 415 V with rated bus bar, Suitable for Flush Mounting and Surface Mounting/ Concealed in wall with provision and including 125 Amp MCCB of 4P, 25 KA as Incomer, IP 54 Protection. Complete all as specified and directed by Engr-in-Charge. Note :- Rate of MCCB 125 Amp deemed to be included in above quoted rate. |
| 135 | S&F in replacement TPN DB, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way (Concealed flush to wall), 415 volts with bus bar rating 250 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, Complete all as specified and directed by Engr-in-charges.Note : 1.Blank plates will be included on the quoted rates.2. All wires to be properly connected with copper lugs.3.MCB will be measured and paid separately. |
| 136 | S&F in replacement Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 08 way (Concealed flush to wall), 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, Complete all as specified and directed by Engr-in-charges. |
| 137 | S&F in replacement 415 V 10KA \"C\" curve miniature circuit breaker (MCB) three pole(TP) of 25 to 63 Amp current carrying capacity in theDB complete with connection testing and commissioning Complete all as specified and directed by Engr-in-charges. |
| 138 | S&F in replacement 415 V 10KA \"C\" curve miniature circuit breaker (MCB) four pole(TPN) of 40 to 100 Amp current carrying capacity in the TPN DB complete with connection testing and commissioning Complete all as specified and directed by Engr-in-charges. |
| 139 | S&F in replacement 240V 10KA \"C\" curve miniature circuit breaker (MCB) Double pole(SPN) of 32 Amp current carrying capacity in the DB complete with connection testing and commissioning Complete all as specified and directed by Engr-in-charges. |
| 140 | S&F in replacement 240V 10KA \"B\" curve miniature circuit breaker (MCB) Single pole(SP) of 40 Amp current carrying capacity in the DB complete with connection testing and commissioning Complete all as specified and directed by Engr-in-charges. |
| 141 | S&F in replacement 240V 10KA \"C\" curve miniature circuit breaker (MCB) Single pole(SP) of 5 Amp to 32 Amp current carrying capacity in the DB complete with connection testing and commissioning Complete all as specified and directed by Engr-in-charges. |
| 142 | Taking down existin submain wiring and M&L concealed type sub mainwiringalongwithearthwire with size of 4x10.0 Sq mm and 1x10.00 sq mm earthcontinuity conducorand connected to earth dolly ,PVC FRLS insulated single core multi stranded copper conductor cable drawn into and incl PVC concealed conduit of suitable size withallaccessoriesandfittings like bends.crossesetc. Complete all as specified and directed by Engr-in-charges.Note: 5 runs of 16 sqmm cable and one run of PVC concealed conduit shall be measured as one unit length. |
| 143 | Taking down old sub main wiring and M&L for concealed sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : Tworun of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cableincuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces. Complete all as specified and directed by Engr-in-charges. |
| 144 | All as per srl item no. 143 here-in-before but with 2 run of 4.0 sq mm FRLS copper wire with one run 4 Sqmm FRLS copper cable as earth wire. Complete all as specified and directed by Engr-in-charges. |
| 145 | Supply, laying, testing and commissioning of LT UG cable, XLPE insulated, PVC sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 50 sqmm 3.5 core, suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, Complete all as specified and directed by Engr-in-charges.Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it.2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items. |
| 146 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm under ground cables for protection Complete all as specified and directed by Engr-in-charges. |
| 147 | M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to under ground cableComplete all as specified and directed by Engr-in-charges. |
| 148 | M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, Complete all as specified and directed by Engr-in-charges. |
| 149 | Supply & laying for pipe galvanised medium class including all fittings of size 25 mm dia laid in trenches or fixed in any indicated situation Complete all as specified and directed by Engr-in-charges. |
| 150 | Supply and fix Gun metal gate valve 25 mm dia complete all as specified and directed by Engr-in- Charge |
| 151 | M&L for Cutting the existing water supply DI/GI pipe line 80/50 mm dia and taking branch connection of 25 mm dia pipe including insertingTee of suitable sizecomplete all as specified and directed by Engr-in- Charges. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail