| 1 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exc 15cm thickness (below or above ground level), complete all as specified and as directed. |
| 2 | M&L for 25 mm thick PCC type B0 (1:2:4) using (12.5 mm graded stone aggregate) as in flooring, complete all as specified and as directed. |
| 3 | M& L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection finished even and smooth w/o using extra cement, complete all as specified and as directed. |
| 4 | M& L for 100 mm thick PCC 1:4:8 type C-2 using 40 mm graded aggregate as in sub base, complete all as specified and as directed. |
| 5 | M&L 10 mm thickVirified Ceramic tiles light shade (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over andincl 15mm thick screed in CM(1:4), complete all as specified and as directed. |
| 6 | S&F in repair 2nd class softwood in scantling clean swan timber framed and fixed to the position including dismantling, complete all as specified and as directed. |
| 7 | Dismantling timber scantlings in fillets, rails,posts rafters,purlins etc under 40 sqcm in section unframed work, complete all as specified and as directed. |
| 8 | M&L for plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails exc 13 Sqcm but n. exc 25 sqcm in section, complete all as specified and as directed. |
| 9 | S&F 3mm thick Sheet glass ordinary quality and glazing with oil putty in square not exceed 0.5 sqm in each pane including, complete all as specified and as directed. |
| 10 | S&F in repair Harrison rails 20mm aluminium alloy,chromium plated with fixing brackets,stops,roller etc, complete all as specified and as directed. |
| 11 | Dismantling of wall and celling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness inlcuding cover fillets, complete all as specified and as directed. |
| 12 | S&F2nd classsoftwoodboarding, fixed with nails in any situation (except flooring and skirting) Planed one side and edgestongued and grooved or rebated on wall of 10-15mm, complete all as specified and as directed. |
| 13 | S&F 2nd classsoftwoodboarding,fixed with nails in any situation (except flooring and skirting) Planed one side and edgestongued and grooved or rebated on ceiling 10-15mm, complete all as specified and as directed. |
| 14 | M&L plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails not exc 3 sqcm in section, complete all as specified and as directed. |
| 15 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, complete all as specified and as directed. |
| 16 | S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 GSM, complete all as specified and as directed. |
| 17 | S&F Plain galvanised mild steel sheeting 0.80 mm thick, with zinc coating 275GSMgalvanising as in ridges, valley gutters etc(length and girth as fixed), complete all as specified and as directed. |
| 18 | Applying two coats of synthetic enamel painting to new steel surfaces based exc. 10 cm width/girth over one coat of red oxide primer including new or previously untreated surfaces including filling with filler where reqd, complete all as specified and as directed. |
| 19 | Taking down chowkats or frames but with shutters (without taking off shutters from the frame) exc 1.5 Sqm and n.exc 4.00 sqm, complete all as specified and as directed. |
| 20 | Taking down chowkats or frames but with shutters (without taking off shutters from the frame) not exc 1.5 Sqm, complete all as specified and as directed. |
| 21 | S&F 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed. |
| 22 | S&F 2nd class soft wood glazed and skeleton shutters 35 mm thick , open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and as directed. |
| 23 | S&F Glazed and skeleton shutters thickness 30 mm, (2nd class softwood), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Sectionspecified 8 clause 8.24(b) , complete all as specified and as directed. |
| 24 | S&F Aluminium anodised, barrel tower bolts 100 mm of extruded section and fixed, complete all as specified and as directed. |
| 25 | S&F Aluminium anodised, barrel tower bolts 150 mm of extruded section and fixed, complete all as specified and as directed. |
| 26 | S&F Aluminium alloy, anodised, sliding door bolt 200 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed. |
| 27 | S&F M S Butt hinges 100 mm medium weight, cold rolled mild steel, complete all as specified and as directed. |
| 28 | S&F M S Butt hinges 75 mm medium weight, cold rolled mild steel, complete all as specified and as directed. |
| 29 | S&F Aluminium handles 100 mm , cast type,anodised, complete all as specified and as directed. |
| 30 | S&F Aluminium handles 150 mm , cast type,anodised, complete all as specified and as directed. |
| 31 | M&L two coats of synthetic enamel paint over and incl a coat of pink primer including preparation of surface on new wooden sruface over 10 cm width or girth, complete all as specified and as directed. |
| 32 | Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed. |
| 33 | S&F Softwood 2nd class Clean sawn with butt joints eaves boards 20 mm thick, complete all as specified and as directed. |
| 34 | M&L Softwood 2nd class Weather boarding, 25 mm thick, wrought both sides, V-jointed to give 20mm laps and fixed, complete all as specified and as directed. |
| 35 | M&L Preparation of old wooden surface of any description and applying over a coat of primer, two coat of synthetic enamel paint, not otherwise described,over 10cm width or girth, complete all as specified and as directed. |
| 36 | M&L Creosote preparing surfaces of wood and wood based materials, and wood based materials, new or old, of any description and girth, not otherwise described and treated with, complete all as specified and as directed. |
| 37 | M&L for rubber moulded coloured durapaved heavy dutytile 10-12 mm thick ( std size ) set, jointed and pointed in neat cement slurry in floors with grey cement with pigment over and incl 15 mm thick screed bed in CM (1:6), complete all as specified and as directed. |
| 38 | Demolition of brick work, PCC block masonary, stone masonary or boulder masonry built in cement mortar, complete all as specified and as directed. |
| 39 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:6), complete all as specified and as directed. |
| 40 | M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6), complete all as specified and as directed. |
| 41 | M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4), complete all as specified and as directed. |
| 42 | M&L for preparation of new surfaces of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint, complete all as specified and as directed. |
| 43 | M&L for6 mm thick Plywood in repair, grade BWR, type BB, fixed with screws to timber frame work fixed with nailsto timber frame work on walland wall etc, complete all as specified and as directed. |
| 44 | M&L for 6 mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work fixed with nailsto timber frame work on ceilingand wall etc, complete all as specified and as directed. |
| 45 | M&L for Hardcore of broken stone of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15cmthick, watered and rolled/rammed to a true surface, complete all as specified and as directed. |
| 46 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc |
| 47 | M&Lfor point wiring inPVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqmm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor. |
| 48 | (a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 49 | (b) One 3 pin 5 Amp switch socket outlet on independent board |
| 50 | (c)One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 51 | M&Lfor point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 2.5 Sqmm as earth continuity conductor. |
| 52 | S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed |
| 53 | S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed |
| 54 | S&FSocket outlet 2 in 1, 3 pin, 5 Amps, flush type,complete with gang box, complete all as specified and as directed. |
| 55 | S&F Switch socket combination 2 in1, 3 pin,5 Amps and 15 Amp flush type complete with gang box, complete all as specified and as directed. |
| 56 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 57 | S&F in repairs Distribution Board, SPN 8 Way, Single door, complete all as specified and as directed. |
| 58 | S & F in repairs MCB,DP 63Amps 240 VoltsB curve, complete all as specified and as directed. |
| 59 | S & F MCB Single pole 6-32A Amps 240 Volts C Curve, complete all as specified and as directed. |
| 60 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 61 | S&F LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 62 | S&F LED Lamp 12 W, complete all as specified and directed. |
| 63 | S&F Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and directed. |
| 64 | S&F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet, complete all as specified and as directed. |
| 65 | Supply & fixing in repair capacitor 1.5/2 mfd suitable for 1200mm sweep ceiling fan, complete all as specified and as directed. |
| 66 | M & L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm diaPVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed.Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing capping shall be measured as one RM |
| 67 | Supply and fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectionalarea 16 Sqmm 2 core, complete all as specified and as directed. |
| 68 | Taking down & dismantling the ceiling fan from site and removing its allied smaller parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, split pins, screws, nuts and spring washers complete including, flexible chord of 24/ 0.20mm with neccessary connector (for blade/ body) as required after rewinding complete all as specified and as directed. Note : Spares used and rewinding shall be measured and paid separately under relevant item |
| 69 | M&L in repairs for Earthing complete with galvanizedsteel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, RFR and removal etc |
| 70 | Note:- Schedule of credit Rs 1,06,471.60will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. |