| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. |
| 2 | Dismantling of floor,hearth or wall tilling including cement mortor bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 3 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed |
| 4 | M&L for 50mm thick PCC 1:2:4 type B-2 using 40mm graded stone aggregate as levelling course laid and compacted in slope, in floor including rough finished with out using extra cement. complete all as specified and directed. |
| 5 | M & L for Virified Ceramic tiles 7-8mm thick light shed (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floor laid over and including 15 mm thick screed bed in CM 1:6 as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 6 | M & L for non skid coloured ceramic tiles 7 to 8mm thick square / rectangular area of each tile exc 0.11 Sqm but not exc 0.18Sqm as in floor laid over 15 mm thick screed bed in CM 1:6 as in floor etc. set and jointed in neat cement slurry and pointed in coloured cment to match colour tiles complete all as specified. |
| 7 | M & L for Glazed ceramic colouredtilesin vertical surface 350x250x7mm/ 450x300x7mm thick, set and jointedin neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in cm 1:3 complete allas specified. |
| 8 | M & L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick set, jointed and pointed in neat cement slurry over 15mm thick screed bed in CM 1:6 as in floors complete all as specified. |
| 9 | Material and labour for 18-20mm thick granite (of any type),machine cut and machine polished, and moulded as in steps, jambs, pillar, counter WHB, floor, etcover and including 10mm thick in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite, complete all as specified. |
| 10 | M&L for 80mm thick coloured machine pressed precast concrete interlocking paver block glossy finished any size and shape conforming to IS 15658-2006 , M-35 Grade with grey cement and pigmentover sand filling including 50 mm thcik sand cushioningcomplete all as directed. |
| 11 | Taking down chowkats or frames not exc 1.5 sqm each with shutter (without taking off shutter from the frame) and removing complete all as specified and directed by Engr-in-charge. |
| 12 | Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each but with shutter (without taking off shutter from the frame) and removing to storecomplete all as specified and directed by Engr-in-charge. |
| 13 | S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube supplying & fixing in opening as per specified & drawing. |
| 14 | S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C\" channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 15 | Cutting holes in brick walls exc 1/2 brick & n exc full brick built in cement mortar for inserting hold fasts, cutting and preparation of brick wall for insertion of doors, windows & ventilator and making good dismantled portion in cement mortar 1:3 etc complete. |
| 16 | S&F pressed steel frame size (105 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hold fast hinges, lock strike plate, etc complete as specified. |
| 17 | Supplyand fixing factory made flush shutters 40 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, ISI marked complete all as specified. |
| 18 | S & F 35 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars) chamfered or rounded,fitted with cut and mitred beads for securing glass etc., sizes of members of shuttersas specified in SSR Pt I Section 8, clause 8.24 (a) |
| 19 | M&L Aluminium powder coated (powder coated of requried colour) three track sliding windows frame top & sides of size 92x31.75x1.50 mm (section No 20831), bottom size 92x31.75x1.50mm (section No 20832) and shutter top & bottom of size 40x18x1.55mm (section No 20736) and sides (handle) of size 40x18x1.55mm (section No 20738) and lock side shutter frame of size 40x18x1.45mm ( section No 20737)\" with including and fixing rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including & fixing stainless steel wire mesh 0.36mm nominal dia of wire with 1.40mm average aperture and fixed with stainless steel wire staples and including and fixing 5mm thick glass with necessary rubber beading gasket etc including necessary plaster, painting ,cill and making good to disturbed portion all as specified and as directed. |
| 20 | S&F aluminium powder coted ventilator louvers type frame top and bottom of size 31x42x1.60mm(sec no-20558) rectaular tube of size 40x20x2 mm (sec no-14019 and middle verticalof size 42x46.20x1.60mm sec(20560) and clip for fixing wiremesh and glass of size 19x17.30x0.90mm (sec no-19360)thick including and fixingstainless steel wire cloth 0.36mm niminal dia of wire and 1.40mm average width of aperature and fixed with stainless steel wire staples and supply and fixing 5mm thick louvers with blades of 100 mm heavy duty with neccessary rubber beading ,gasket etcincluding necessary plaster, painting ,cill and making good to disturbed portion complete all as specified and directed. |
| 21 | S&F aluminium anodised grill of 7.00mm dia square, rectangular, triangular and circular shape aperture n. exc 7 cm in length or width fixed with H or F channel complete all as specified and directed |
| 22 | S & FStainless steel wire cloth, 0.63 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed |
| 23 | S & F 100 mm long extruded mild steel anodised Butt hinges with galvanized mild steel and fix complete all as specified and directed |
| 24 | Supply& fixing Aluminiumbarrel tower bolt of 150mm long stove enamelled black withbrightbolt complete all as specified and directed by Engr-in-charge. |
| 25 | S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts oftruded sections or cast-aluminium alloy and fixed complete all as specified anddirected by Engr-in-charge. |
| 26 | Supply& fixing Aluminium alloy pressed handle oval type stove enamelled black of 125mm long fixed with screw to shutter complete all as specified and directed by Engr-in-charge. |
| 27 | Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed |
| 28 | M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed. |
| 29 | M&L for two coats of synthetic enamel paint (first quality) on steel surfaces over a coat of red oxide primerincludingpreparation of new steel surfaces of any description not otherwise described over 10 cm width or girth, complete all as specified. |
| 30 | M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint (first quality) over red oxide complete all as specified and directed. |
| 31 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed. |
| 32 | Material & labour old size brick work with sub class \"B\" bricks in CM 1:6 brickstraight or curved on plain exeeding 6m mean radius complete all as specified and directed. |
| 33 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc. |
| 34 | M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) and finished even and smooth (without using extra cement) complete all as specified and directed. |
| 35 | M & L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement) complete all as specified and directed |
| 36 | Material and Labour for 5mm thick cement plaster in CM (1:3) to ceiling surfaceand finished the surface even and smooth without using extra cement complete all as specified. |
| 37 | M & L for preparation of surfaces ofwall & concrete surface and applying 1 mm thick wall care putty including preparation complete. |
| 38 | M&L for preparation of new plastered or unplasteredsurfaces of wall andapplying two coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper complete. |
| 39 | M&L preparation of new plastered or unplastered surfaces of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over& including 1 mm thick of cement base putty complete all as specified and directed. |
| 40 | M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 41 | M & L for preparation of old plastered surfaces of ceilings and applying one coat of white wash complete all as specified and directed. |
| 42 | M&L for 50mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed. |
| 43 | S&Fin repair bib tap 15 mm bore fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete. |
| 44 | S&F in repair angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe. |
| 45 | S&F in repair15mm dia pillar taps cast copper alloy chromium plated ,screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks & fly nuts screwed for iron pipe (bore of pipe 15mm) |
| 46 | S&F in repair CP brass tubular towel rail 20 mm dia D type 60 cm long between flanges complete. |
| 47 | S&F in repair for 15 mm bore fancy type Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixedcomplete all as specified and directed |
| 48 | S&F for in repair Brass chromium plated shower rose 125mm size Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union |
| 49 | S&F in repair of stainless steel soap dish, of standard size and shape complete. |
| 50 | S&F in repair vitereous china wash basin, white flat back,size 550x400 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, incl 32 mm diabrass CP waste fittings (coupling)including32 mm waste pipe complete all as specified and directed |
| 51 | S&Fin repair vitreous china wash down water closet pan (Pedestal pattern)white including fixing bolt and plastic water closet seat white closed pattern with flat bottom cover with MS chromium plated hinging devices to matching colour complete all as specified and directed |
| 52 | S&F in repair of cabinet mirror of selected quality glass, mounted pvc board including shelf assembly complete all as specified and directed |
| 53 | S&Fin repair 10 Ltr capacity PVC valveless shyphonic action type low level flushing cistern white with inlet, ball valve, float valve and handle incl bracket and flush pipe of low level of 32mm dia fixed to wall complete. |
| 54 | S & F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 55 | S&Fin repair PVC connection 15mm size with PTMT nut of length 450mm complete all as specified and directed |
| 56 | Taking down AC/PVCpipes (including all fittings), with spigot and socket ends and lead joints including burning out joints of 100/75 mmdia pipe complete all as specified and directed |
| 57 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete. |
| 58 | M/L PVC(SWR) bend of110mm dia of any radius etc complete all as specified and directed |
| 59 | M/L PVC(SWR) Tee of110mm dia etc complete all as specified and directed |
| 60 | S&F PVC (SWR) multi floor trap, plain with grating with or without waste hole including jointing with solvent cement 75mm dia etc complete |
| 61 | S&F in repair C.P. grating 100mm square/round with or without hole complete all as specified and directed |
| 62 | S&F in repairs stainlesssteel toilet paper holder fixed with wooden gutties and screws to wall surfaces complete all as specified and directed |
| 63 | S&F in repairs mild steel, chromium plated curtain rod 20mm dia with holder/bracket, stops, rollers etc complete all as specified and directed |
| 64 | S & F in repairs 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 65 | M&L for complete removal of existing water proofiing treatment from top of roof (flat of sloped) and canopies / chajjas of building including demolition of PCC any thickness and removal of debries out side Md land completer all as specified and directed. |
| 66 | M&L Water proofing treatment on \"Non approachable / non accessible and approachable roof\" surface (Horizontal, sloped& Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete(i) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm.(ii)Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces.(iii) Laying /unrolled over the bitumen coated surface, APPbasedpolymericmembraneminimumweighing3kg/sqmandminimum3mmthickreinforced with polyster non wove fabric (wt. notless than 150 gms/sqm)land on primed surfaceby forced application complete all as specified with 100 mm over laps shall be sealed by flame as per manufacturers instruction.(iv)Applying two coats of bituminous aluminium paintincluding preparation complete. |
| 67 | M&L for PCC 1:2:4 type B0 (Using 12.50 mm graded stone aggregate) as in roof padding / kerbs / sunken slab etc complete all as specified and directed. |
| 68 | M&L 10 mm thick rendering on roof surfaces / concrete surface in CM 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) complete all as specified and directed. |
| 69 | Supply only integral water proofing compound of approved brand/make. |
| 70 | Dismantling water tanks of capacity exc 250 & n exc 500 litres and removing to store all as specified and directed. |
| 71 | S&F500 Ltrs capacity PVCRotational Moulded polyethylene water storage tanks (Cylindrical vertical with closed top)double layer hoisted and fixed in position all as specified. |
| 72 | S&F in repair ball valve/float ballhigh pressure of PTMT 20mmwith epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimume weight 210 gm etc all as specified and directed. |
| 73 | S&F in repair 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed. |
| 74 | S&F in repair 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed. |
| 75 | Taking upor down steel tubing and connections with all fittings for 15 mm bore GI tubing complete all as specified and directed |
| 76 | Taking upor down steel tubing and connections with all fittings for 20 mm bore GI tubing complete all as specified and directed |
| 77 | Supply and fixing steel water tubing of 15 mm bore, medium grade galvanized with provision of all new fittings as required, laids in floor , wall and on ceiling, complete all as specifiedand directed . |
| 78 | Supply and fixing steel water tubing of 20 mm bore, medium grade galvanized with provision of all new fittings as required, laids in floor , wall and on ceiling, complete all as specifiedand directed . |
| 79 | M&L for preparation of old plastered or decorated surfaces of wall andapplying two coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper including complete removal of the existing treatment |
| 80 | M&L preparation of old plastered or decorated surfaces of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over& including 1 mm thick of cement base putty including complete removal of the existing treatment. complete all as specified and directed. |
| 81 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete. |
| 82 | S&F PVC (SWR) bends any radiusprovided with access door of 75 mm dia complete all as specified and directed |
| 83 | Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent , regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 84 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully Metal clad Box/SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 85 | Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 86 | Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and keeping at site under safe custody or deposit to MES store yard of AGE (I) Pachmarhi complete all as specified and as directed. |
| 87 | Taking down exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan and keeping the same at site under safe custody or deposit to MES store yard of AGE (I) Pachmarhi complete all as specified and as directed. |
| 88 | Taking down ceiling fan of any sweep complete with down rod,motor,blades etc.after disconnecting all necessary electrical connections from ceiling rose to fanand keeping the same at site under safe custody or deposit to MES store yard of AGE (I) Pachmarhi complete all as specified and as directed. |
| 89 | Taking down existing single phase electric energy meter of any type /size/ capacity after disconnecting all necessary electrical connections and keeping the same at site under safe custody for refixing the same in its original location including necessary electrical connections or deposit to MES store yard of AGE (I) Pachmarhi complete all as specified and as directed. |
| 90 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts gradeISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches,including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly includingcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 91 | (a) One light point controlled by one, one way switch 5 Amps |
| 92 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 93 | (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 94 | (d)One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 95 | (e) One bell point controlled by one, bell switch 5 Amps |
| 96 | Description all as per item No 91 here in before butusing 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor FRLSH cable of multistranded PVC insulated unsheathedas earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 97 | Description all as per item No 91 here in before butusing 4.0 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of4.0 sq mm copper conductor FRLSH cable of multistranded PVC insulated unsheathedas earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 98 | S & Ffor ceiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete. |
| 99 | S & Ffor modular switch piano flushtype, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 100 | S & Ffor modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 101 | S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 102 | S & Ffor modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 103 | S & Ffor modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 104 | S & Ffor Bell push modular 6 Amps single module complete all as specified. |
| 105 | S & Ffor lamp holder, PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed. |
| 106 | S & Ffor Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 107 | S & Ffor modular type TV Socket out let complete all as specified and as directed. |
| 108 | M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 109 | S & F for sheet metal enclosure MCBDBTPN4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 110 | S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 111 | Supply and fixing 415V 10KA \"C\" curve miniature circuit breaker (MCB) ofTP 40 To100 Amps current carrying capacity in the DB complete with connection testing and commissioning. |
| 112 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 113 | S & Ffor MCB Single pole rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 114 | S & Ffor metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Ampsincluding removal of old unserviceable one complete all as specified and as directed complete. |
| 115 | M&L for re-fixing only the serviceable water Heater storage type (Geyser) vertical/ Horizental type of capacity 25/50 Ltrs, electrically operated, AC 230 Volts including 04 Nos of hold fashner nuts required suitable size fixed in brick wall, PVC connection pipe hot & cold complete all as specied and directed |
| 116 | Labour only for refixing the celing fan obtained from item No 6 above with replacement of unsv3 corePVC insulatedPVC sheated 3 core multistrandedcopper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including Servicing / over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spray Gun including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed. |
| 117 | S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL Retro fit lamp,in B-22 cap complete all as specified and directed |
| 118 | S & F for Decorative wall mounted, chmpage gold finish fixture and made out of polycarbonate with unbreakable globe suitable for LED bulb and provosion of LED bulb 9 watts complete all as specified and as directed. |
| 119 | S & F forLED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fitting complete all as specified and as directed. |
| 120 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 121 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired andnecessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. |
| 122 | Labour only for fixing of old serviceable exhaust fan of 230 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan basecompelte all as specifiedand directed. |
| 123 | S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connectionsincludingcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster complete all as specified and directed. |
| 124 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |
| 125 | S & F for Highly efficient LED Re-chargeableBulbs, 9/10 W, used as a ready replacement for existing GLS/CFL Retro fit lamp,in B-22 cap complete all as specified and directed |
| 126 | Schedule of credit amount of Rs. 74,638.30 to be deducted during AOC |