| 1 | Demolation of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing the debris outside the defence land complete all as specified and as directed |
| 2 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as directed. |
| 3 | Dismantlingtimber in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 5 | Dismantling of Wallandceilingboards(fibre, pulp, insulation, etc.) or insulationboards/slabs/ blankets, any thickness, including cover fillets. |
| 6 | Dismantling plain or corrugated steel sheeting any thickness, complete all as specified and directed. |
| 7 | Dismantling timber scantlings 40 sq. cm and over in section, in any position, unframed work |
| 8 | Taking down chowkhats or frame exc 1.5 sqmtrbut n.exc 4 sq m(without taking off shutters from frames), complete all as specified and directed. |
| 9 | Taking down chowkhats or frame n.exc 1.5 sqmtr (without taking off shutters from frames), complete all as specified and directed. |
| 10 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard /dense soil |
| 11 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point of any type of soil. |
| 12 | Returning/filling in including spreading, levelling, watering and well ramming in layers n exc 25 cmin hard/dense soil. |
| 13 | Excavating over areas, nexe 1.5 deep and getting out hard soil |
| 14 | Excavating over areas, exe 1.5 and nexe 3mdeep and getting out hard soil. |
| 15 | Excavating over areas, nexe 3 m and nexe 4.5m deep and getting out hard soil. |
| 16 | Excavation in trenches n,exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in hard/dense soil. |
| 17 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads |
| 18 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. → |
| 19 | M & L for second class hard wood Plain fillets cross sectional area n exc 3 sq cmsquare, rectangular or triangular in section, clean sawn, secured with nails or brads. |
| 20 | M & L for Second class hard-wood in scantlings, clean sawn timber unframed and fixed. |
| 21 | M&Lsecond class hard wood plain fillets.square, rectangular or triangular in section, clean sawn, sectional area exc 13 sq cm and n exc 25 sq cm secured with nails |
| 22 | M & L for plain cement concrete Type - D2 (1:4:8) ( using 40mm graded stone aggregate) as mass concrete complete all as specified and as directed |
| 23 | M&L for 40 mm thick cement concrete 1:2:4 type B1 ( using 20 mm graded stone aggregate) as in floor /sub base coat. |
| 24 | M&L for 75 mm thick 1:3:6 type C2 ( using 40 mm graded stone aggregate) as plinth rotection./paving/footpath. |
| 25 | M&L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as cement concrete in Sub-base floors, sub-bases floors and pavings etc complete all as specified. |
| 26 | M&L for 10mm thick rendering in CM (1:6) over block/concrete wall surfaces finished even and smooth without using extra cement. |
| 27 | M&L for 15 mm thick rendering in CM (1:4) in two layers on fair faces of Concrete surfaces of walls mixed with LWPC by weight of cement as per manufacturer instrution, finishing the surface even and smooth complete.(LWPC measured and paid saperately) |
| 28 | M&L for 15 mm thick screed bed in CM 1:6 for laying floor tiles . |
| 29 | M&L for 4mm thick plywood, (3 Nos of ply)grade BWR, type BB, fixed with nailsto timber frameworkin ceiling |
| 30 | M&L for 6mm thick plywood, (5 Nos of ply)grade BWR, type BB, fixed with nailsto timber framework. |
| 31 | M&L for cover fillets of tempered hard board6mm thick, 40mm widefixingwith screws in ceiling, flat or sloping complete all as specified and as directed |
| 32 | M&L for hard core of gauge n.exc 63mm (broken stone and boulders), deposited, spread and levelled in layers nexc 15 cm thick, watered and rammed to a true surface. |
| 33 | M&L for MS TMT bars10mm dia and over, cut to lenth, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 34 | M&L for MS TMT bars 05mm dia and over, upto and including 10 mm dia in stirrups, spaces and binders. |
| 35 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete. |
| 36 | M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete |
| 37 | M&L for precast cement concrete solid building blocks (1:3:6), type C-1, 10 cm thick (with plain or interlocking joints as directed) setting in cement mortar (1:4), complete, laying inner side of wall. |
| 38 | M&L for preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome complete all as specified and directed. |
| 39 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound destemper,over a coat of primer complete all as specified and directed. |
| 40 | M&L for prepration of new wooden surfaces exc.10cm in width or girthand applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 41 | M&L for reinforced cement concrete (Nominal mix) (1:2:4) type B1 (using 20mm graded aggregate) as in slab supported on walls, beam and columns in floor, roof, landing, balcony, canopies, deck slab and in shelves and like |
| 42 | M&L for re-inforced cement concrete (nominal mix) 1:2:4 type B-1(20mm graded aggregate) as in columns ,pillars,piers,posts and struts complete. |
| 43 | M&L for re-inforced cement concrete (nominal mix) 1:2:4 type B-1 (20mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete. |
| 44 | M&L for re-inforced cement concrete (nominal mix) 1:2:4 type B-1 (20mm graded aggregate) as in foundations,including rafts,plinth beams,bases for columns,etc;basement slabs,under-reamed piles and mass concrete. |
| 45 | M&L for Virified Ceramic Dark shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchinclscreed bed with CM (1:6) 15mm thick for laying floor tiles complete all as specified and directed. |
| 46 | M&L forNon skid coloured ceramic colouredtiles 7 to 8mm thick Square/rectangular) area of each tile exc 0.11 and nexc .18 sqm in flooretc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match inclscreed bed with CM (1:6) 20mm thick for laying floor tiles complete all as specified and directed. |
| 47 | M & L for 350 x 250 x 7 mm/450 x 350 x 7 mm thick glazed coloured ceramic tiles on vertical surface of wallset and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. (Make; Kajaria/ Orient/ Bell/ Johnson/ Somany). |
| 48 | M & L for Non-skid ceramic coloured tiles 7 to 8 mm thick ( square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match. |
| 49 | M&L Second class hard wood clean swan timber framed work as in scantling. |
| 50 | Preparing of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 51 | S & F30 mm thick flush shutters,solid core construction with block board core and plywood face panel, commercial type on both sides, complete all as specified and directed. |
| 52 | S & Ffor droppery rod with Aluminium, tubular rail 20mm dia as in curtain rails, with fixing brackets, stops, rollers etc . Note brackets will be measured and paid seperately. |
| 53 | S & F 150mm size extruded aluminium alloy handles, fabricated type, anodised. |
| 54 | S & F 15mm Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms). |
| 55 | S & F 15mm Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts,screwed for iron pipe and fixed |
| 56 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frameshall be covered with heat moulded plain colour PVC \"C\" channelhaving a PVC sheet strip of 20mm width stuckinside with solventcementfor stiles and plain colour PVC sheets for top rail, lock & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frameat siteas per specification & drawing. |
| 57 | S & F in repairs for Aluminium anodised bracket powder coated or approved make for fixing droppery rod fixed in repairs |
| 58 | S & F plain Sheet glass 3mm thk , ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane |
| 59 | S & F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets. |
| 60 | S & F Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete. |
| 61 | S & F vitreous China squatting pan, ‘Orissa\" pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete. |
| 62 | S & F Vitreous Cliina wash basin, wlhite, flat back, size 550x400 irun (for Hospilal use) excluding taps, waste, chain and plug and porcelain stopper but including cutting for and pinning in ends of brackets or erecting stand |
| 63 | S & FWaste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms) |
| 64 | S& F PVC connections 15 mm size, 450 mm long with PTMT nuts |
| 65 | S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 66 | S&F 15mm Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm-125gms) |
| 67 | S&F 2ndclass HW plain solid straight chowkhats and frame wrought framed rebated on the soild rounded or chamfered put together with glue pinned at joints, complete all as specified and directed. |
| 68 | S&F 300mm long aluminium anodized sliding door bolt with hasp and staple (bolt type and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sectionsor cast alluminium alloy complete all as specified and as directed. |
| 69 | S&F 30mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of windowsas specified in SSR Part I, Section 8, clause 8.24 (b); but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars,any numbers supplied and fitted to chowkats |
| 70 | S&F 35mm thick 1st class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats |
| 71 | S&F 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats |
| 72 | S/F 35 mm thick flush shutters,solid core construction with block board core and plywood face panel, one side commercial type and other side with decorative face veneer with lipping/frame to match , complete all as specified and directed. |
| 73 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 74 | S&F for 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed , complete all as specified and directed. |
| 75 | S&F in repairs GI wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with screws or GI staples complete. |
| 76 | S & F 3- layer PP-R Polypropylene random copolymer) of size 25 mm outer dia concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/wall with all connected fittings as required at site all as directed and specified. |
| 77 | S.&.F PP-R Gate valves (brass insert) 25 mm dia as per requirement of the site. |
| 78 | S&F PP-R Gate valves 20 mm outer dia of pipes (brass insert) as per requirement of the site |
| 79 | S & F 20mm 3-layer PP-R P o l y p r o p y l e n e random copolymer concealed pipes SDR 7.4PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc |
| 80 | S&F PVC (SWR) bends any radius with access door, 110mm dia. |
| 81 | M&L 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement |
| 82 | S&F PVC (SWR) junction single, (single T) equal or unequal, 75mm dia. |
| 83 | Supply and fix 4 mm thick sheet glass, ordinary quality and glazing with oil putty in squaresn.exceeding 0.50sqm in each pane , complete all as specified and directed. |
| 84 | Supply and fix Aluminium anodized barrel tower bolts of extruded section, 150 mm long, complete all as specified and directed. |
| 85 | Supply and fix Aluminium anodized barrel tower bolts of extruded section, 200 mm long, complete all as specified and directed. |
| 86 | Supply and fix Aluminium handles, cast type, anodized, 150 mm size , complete all as specified and directed. |
| 87 | Supply and fix mild steel butt hinges, medium weight, cold rolled 100 mm size , complete all as specified and directed. |
| 88 | S&F Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms). |
| 89 | S&F Rotational mounded polythene water storage tank of 1000 ltrs capacity,(multilayered, cylindrical, vertical with closed top) hoisted and fixed in position as specified in SSR Pt-I. |
| 90 | S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying and fixing in opening as per specification and drawing. |
| 91 | Suppiled only liquid WPC |
| 92 | Supply and fix Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifie |
| 93 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 94 | U & W of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete. |
| 95 | Use & waste of form work to side and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilivers, shelves including supports, overhangs etc, also splays betweennfloors and beams etc, rough finished flat surfaces of concrete. |
| 96 | Use & waste of form work to sides of pillars, posts, struts,piers, columns and stanchios rough finished square, rectangular or polygonal surfaces of concrete. |
| 97 | Use and waste for flat formwork to soffits of suspended slab such as roof slab, landings and similar work not exc 200mm thick (horizontal or sloping) |
| 98 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 99 | M/L for point wiring in casing caping with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing caping with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: One light/fan point controlled by one No piano type switch5 Amps single pole one way |
| 100 | All as per item No 99 One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board. |
| 101 | All as per item No 99 One socket outlet 5/3 pin 6 AMPS controlled by one switch onindependent board. |
| 102 | All as per item No 99above but one 3 pin socket out let 15/16 Ampswith three Nos single core unsheathed PVC insulatedcable multistranded copper conductor of size 2.5 sq mm for phase,neutral & earth continuity conductor. |
| 103 | Supply and fixing LED lights fitting 1x 18W, 4 feet, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 104 | M&L Switch Piano Flush button single pole one way 5/6 Amp. |
| 105 | M&L Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal |
| 106 | M&L Switch socket combination 2 in 1, 6A flush type |
| 107 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for battern fittings complete. all as specified and directed by as engineer-in-charge. |
| 108 | M&L ceiling rose surfacebakelite 65mmx50mm 100watt three terminal. |
| 109 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300msweep with, blades, and frame and louvers |
| 110 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 4 way with 200 Amps rated bus bar 240 volts double door (Metallic) typeincluding taking down old Distribution Board and MCBs all as specified and directed . |
| 111 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type including taking down old unserviceable MCB DB with MCBs. |
| 112 | S&F for sub mainwiring with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistandard and incl drawn through and including PVC Casing caping including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly Including taking down old unserviceable sub main wiring and making good of existing surface.Note:-(i)One run of PVC Casing caping, two run of 6 sq mm copper conductor & one run of 6.0 sq mm copper conductor is measured as one unit. |
| 113 | S&F MCB SP 6 to 32 Amps 240 volts \"C\" series, 10 KA, 50 Hz including connection in the DB and testing/commissioning.Make:- As approved Make of DB |
| 114 | S&F MCB SPN 32 Amps 240 volts \"C\" series, 10 KA, 50 Hz.Make:- As approved Make of DB |
| 115 | S&F DWC Pipe 63/50mm size all as specified and directed by Engr-in-Charge. |
| 116 | S&F LED Bulb 9 watt cat part noLED ADORE 9W B22 WW 2 STAR LAMPcomplete all as specified and as directed by engineer-in-charge. |
| 117 | S&F high density polyethylene pipes (HDPE) of pressure rating 6Kgf/cm2 laid in trenches of size 50mm dia all as specified and directed by Engr-in-Charge. |
| 118 | Supply and laying or fixing or passing through pipeXLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm 2 core complete all as specified and directed by Engineer in charge. |
| 119 | Supply and laying or fixing or passing through pipeXLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade of size 16 sqmm 2 core complete including taking out old unserviceable cable all as specified and directed by Engineer in charge. |
| 120 | M & L forXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 Core. |
| 121 | M & L for Galvanised iron strip of size 32 x 6mm buried in ground fixed on wall above porcelain insulator all as directed and specified. |
| 122 | Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edgeof the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized GI wire 4.0 mm asearthing lead by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and provision of concrete pit in PCC (1:3:6) type C1, pre-cast including RCC (1:2:4) type B1, cover slab54 cm x 54 cm x 5 cm, reinforced with 8 mm diaTMT bars @ 150 mm c/c both ways, one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil, dismantling and taking out old earthing plate and necessary testing complete all as shown on electrical plate No 5 of SSR Part –I (2009). |
| 123 | Supply and fixing LED light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 124 | Supply and fixing in repair LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as specified. |
| 125 | Supply, installation, commissioning and testing diesel engine driven, water cooled with L3 cold starting kit silent Generating Set60 KVA /48 KW capacity, 1500 RPM, suitable capacity of 74.8BHP to give output 48 KW with electronic governor, 3 phase, 415 volts, 50 Hz, power factor 0.8 applicable for supplying power to varying electrical load for unlimited hours with 10% over load capacity,complete with manual starting system including common base plate, floor mounted with anti vibration pads, factory asembled complete fitted in acoustic enclosure (sound proof canopy of authorised OEM of manufacturer\"s of DG set ) approved by National Physical laboratory as per CPCB latest norms/regulation, including PCC foundatin/platform for generating set as per manufacture\"s instruction, completeincluding accessories, equipment control panel etc and confirming to condition under IS-4722 BS 5514/2613/5000/10001/10002/13664 complete all as specified and as directed and comprising with the following :-Alternator :- 48 KW output at 0.8 PF AC 3 phase 4 wire 415 volts 50 C/S, brush less, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces, class \"H\" insulation with IP-23 protection and voltage regulation +/- 1.5% as per IS-4722 or BS 5514 Diesel engine : Diesel engine multi cylinder 4 stroke, water cooled electric start suitable capacityto drive above alternator independently, coupled directly through flexible coupling, cold starting, speed of DG set from No load to full load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and residential silencer mufflers etc for continuous operation and standard accessories, sump preheaters etc |
| 126 | Item no 125 Continue:- Control panel :- The standard control panel consisting of control cubical fabricated sheet steel construction indoor type suitable for the followings-(i) Gen set controller microprocessor based multifunctional with LED display for engine water temperature, Lub oil pressure, Engine RPM, Engine shut down display, total Hours run and suitable for protection against high water pressure, low lub oil pressure, over speed and battery charger failure. (ii) Digital multifunctional meter with LED display suitable to display all electrical parameters of individual phase such as Voltage, current, frequency, KVA, KW, power factor and having RS 485 communication port complete with appropriate CTs and control wiring. (iii) MCCB 4 pole 415 volt AC of suitable capacity not less than 63 Amps all as required complete with copper bus bar all as per standard engineering practice and as per manufacturer recomendations. (iv) HRC fuses for protection as per standard engineering practice and manufacturer recommendations for protection of meters etc. Electric Starter Equipment :- The equipment will comprise the followings:- (i) Start Stop push button. (ii)Maint free Battery duly initial charged & Battery lead of adequate capacity. (iii) Starter motor (iv) Starter gearing. (v) Alternator/ dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut. Invertor cum battery charger ofsuitablecapacity for 60 KVA DG Set to work on 230 volts 50 Hz AC supply system for charging of DG set batteries externally when DG set is off position.Note :- (a) Cost of maintainance free batteries as per recoomondations of manufacture shall deemed included in unit rate quoted by contractor(b) Cost of PCC foundation as per reccomondations of manufacturar shall deemed included in unit rate quoted by contractor.(d)All necessary equipments, consumables and T&P required for successful completion of the test shall be arranged by the contractor and cost for the same shall deemed included in unit rate quoted by contractor. |