| 1 | Supply of materials |
| 2 | Supply of one run Aluminium Conductor (solid upto 10 sq.mm & stranded for balance), XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type ST2 Outer Sheathed power cable of 1.1 kV grade (A2XWY) of following size as per IS-7098(part 1)2011. (cost for 1 Meter) 4 core X 35 Sq.mm A2XFY with factory made clamp |
| 3 | Supply of one run Aluminium Conductor (solid upto 10 sq.mm & stranded for balance), XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type ST2 Outer Sheathed power cable of 1.1 kV grade (A2XWY) of following size as per IS-7098(part 1)2011. (cost for 1 Meter) 4 core X 25 Sq.mm A2XFY with factory made clamp |
| 4 | Supply of one run Aluminium Conductor (solid upto 10 sq.mm & stranded for balance), XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type ST2 Outer Sheathed power cable of 1.1 kV grade (A2XWY) of following size as per IS-7098(part 1)2011. (cost for 1 Meter) 4 core X 16 Sq.mm A2XFY with factory made clamp |
| 5 | Supplying end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required )4 X 35 sq. mm (32mm) |
| 6 | Supplying end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required )4 X 25 sq. mm (28mm) |
| 7 | Supplying end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required )4 X 16 sq. mm (28mm) |
| 8 | Supply following way, vertical type three phase and neutral (VTPN), sheet steel, 415V MCB double door distribution board on surface with dust protected,duly powder coated, inclusive of 100 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required. (without MCB and incomer) 4 way (8 + 12 ) |
| 9 | Supply following way, horizontal type three pole and neutral (TPN), sheet steel, MCB double door distribution board , 415 V, on surface complete with 100A fully insulated tinned copper bus bar, srouded neutral bar, earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator).4 way (8 + 12 ) |
| 10 | Supply following way, single pole and neutral (SPN), sheet steel, 230V MCB double door distribution board on surface complete with 100A fully insulated tinned copper bus bar, srouded neutral bar earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator).12 way |
| 11 | Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable in surface / recessed with 20mm medium class, ISI marked PVC conduit / casing and capping, with one way modular switch, modular plate, suitable size modular PVC/GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable (Green) etc. as required. Note: Upto 5Mtr length from Switch board to point |
| 12 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point (without independent switch) with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable with 20mm Medium class, in surface / recessed ISI marked PVC conduit/ casing and caping, and earthing the point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable etc. as required. Note: Upto 5 mtr length in between two adjacent points. Excluding the cost of first point |
| 13 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, 650V, copper conductor, single core cable in surface / recessed with 20/25/32mm medium class, ISI marked, PVC conduit/casing and capping as required.2x1.5 sq.mm + 1x1.5 sq.mm earth |
| 14 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, 650V, copper conductor, single core cable in surface / recessed with 20/25/32mm medium class, ISI marked, PVC conduit/casing and capping as required.2x2.5 sq.mm + 1x2.5 sq.mm earth |
| 15 | Supplying of 10 SWG Copper wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required.(cost for 1 Meter) |
| 16 | Providing 25x3 mm Copper strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. (cost for 1 Meter) |
| 17 | Maintenance free Earthing -Providing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 20mm with copper bonding thickness of 250 microns with with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. Universal Clamp should be exothermic moulded along with earth rod. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances The mineral compound is required to have minimum 20 Kg of the total composite. If using chemical compound min 37.5 Kg is required. Polypropylene & Polyethylene Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 170mm with a weight bearing capacity of 50KN. |
| 18 | Supply of surface mounted 18W, 1700- 2100 lumen output, 230V AC, single phase, 50 Hz, 1200 mm length, T5 LED tube integral light fittings with extruded plastic body complete accessories including inbuilt LED drive, LED tube etc. as required.18-20W 4F/1200mm |
| 19 | Supply of BLDC Ceiling fan with regulator, 230V, 50Hz, 5 star rating complete accessories as required. 1200 mm sweep, 28- 35 W |
| 20 | Supplying following size modular PVC box on surface mode as required.6 Module |
| 21 | Supplying following size modular PVC box on surface mode as required.3 Module |
| 22 | Supplying following size Modular Switch on existing modular switch box/cover including connections etc. as required.1 Module, 1 Way, 5/6A |
| 23 | Supplying following size Modular Switch on existing modular switch box/cover including connections etc. as required.1 Module, 1 Way, 15/16A |
| 24 | Supplying following size Modular Socket on existing modular switch box/cover including connections etc. as required.2 Module, 5 Pin, 6A |
| 25 | Supplying following size Modular Socket on existing modular switch box/cover including connections etc. as required.2 Module, 3 Pin, 6/16A |
| 26 | Supplying following Modular base & cover plate on existing modular PVC/GI box.6 Module |
| 27 | Supplying following Modular base & cover plate on existing modular PVC/GI box.3 Module |
| 28 | Supply single pole blanking plate in the existing MCB DB complete etc. as required. |
| 29 | Supply 10A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 30 | Supply 16A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 31 | Supply 25A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 32 | Supply 25A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole |
| 33 | Supply 32A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Three Pole |
| 34 | Supply 32A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole |
| 35 | Supply 63A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Four Pole |
| 36 | Supply following rating, double pole (single phase and neutral), 240 V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 37 | Supply following rating, four pole (three phase and neutral), 415V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 38 | Supply following rating, four pole (three phase and neutral), 415V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A |
| 39 | Installation charges |
| 40 | Laying and clamping of one run Aluminium/Copper Conductor, XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type Outer Sheathed power cable of 1.1 kV grade of following size on wall surface as required (including supply of GI saddle/ M.S flat clamp, iron screw, fastener), spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.upto 35 Sq.mm A2XFY with factory made clamp |
| 41 | Making end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required )4 X 35 sq. mm (32mm) |
| 42 | Making end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required )4 X 25 sq. mm (28mm) |
| 43 | Making end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required )4 X 16 sq. mm (28mm) |
| 44 | Fixing following way, vertical type three phase and neutral (VTPN), sheet steel, 415V MCB double door distribution board on surface with dust protected,duly powder coated, inclusive of 100 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required. (without MCB and incomer) 4 way (8 + 12 ) |
| 45 | Fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB double door distribution board , 415 V, on surface complete with 100A fully insulated tinned copper bus bar, srouded neutral bar, earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator).4 way (8 + 12 ) |
| 46 | Fixing following way, single pole and neutral (SPN), sheet steel, 230V MCB double door distribution board on surface complete with 100A fully insulated tinned copper bus bar, srouded neutral bar earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator).12 way |
| 47 | Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable in surface / recessed with 20mm medium class, ISI marked PVC conduit / casing and capping, with one way modular switch, modular plate, suitable size modular PVC/GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable (Green) etc. as required. Note: Upto 5Mtr length from Switch board to point |
| 48 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point (without independent switch) with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable with 20mm Medium class, in surface / recessed ISI marked PVC conduit/ casing and caping, and earthing the point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable etc. as required. Note: Upto 5 mtr length in between two adjacent points. Excluding the cost of first point |
| 49 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, 650V, copper conductor, single core cable in surface / recessed with 20/25/32mm medium class, ISI marked, PVC conduit/casing and capping as required.2x1.5 sq.mm + 1x1.5 sq.mm earth |
| 50 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, 650V, copper conductor, single core cable in surface / recessed with 20/25/32mm medium class, ISI marked, PVC conduit/casing and capping as required.2x2.5 sq.mm + 1x2.5 sq.mm earth |
| 51 | Laying of 10 SWG Copper wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required.(cost for 1 Meter) |
| 52 | Fixing 25x3 mm Copper strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. (cost for 1 Meter) |
| 53 | Maintenance free Earthing - fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 20mm with copper bonding thickness of 250 microns with with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. Universal Clamp should be exothermic moulded along with earth rod. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances The mineral compound is required to have minimum 20 Kg of the total composite. If using chemical compound min 37.5 Kg is required. Polypropylene & Polyethylene Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 170mm with a weight bearing capacity of 50KN. |
| 54 | Installation of surface mounted 18W, 1700- 2100 lumen output, 230V AC, single phase, 50 Hz, 1200 mm length, T5 LED tube integral light fittings with extruded plastic body complete accessories including inbuilt LED drive, LED tube etc. as required.18-20W 4F/1200mm |
| 55 | Installation of BLDC Ceiling fan with regulator, 230V, 50Hz, 5 star rating complete accessories as required. 1200 mm sweep, 28- 35 W |
| 56 | Fixing following size modular PVC box on surface mode as required.6 Module |
| 57 | Fixing following size modular PVC box on surface mode as required.3 Module |
| 58 | Fixing following size Modular Switch on existing modular switch box/cover including connections etc. as required.1 Module, 1 Way, 5/6A |
| 59 | Fixing following size Modular Switch on existing modular switch box/cover including connections etc. as required.1 Module, 1 Way, 15/16A |
| 60 | Fixing following size Modular Socket on existing modular switch box/cover including connections etc. as required.2 Module, 5 Pin, 6A |
| 61 | Fixing following size Modular Socket on existing modular switch box/cover including connections etc. as required.2 Module, 3 Pin, 6/16A |
| 62 | Fixing following Modular base & cover plate on existing modular PVC/GI box.6 Module |
| 63 | Fixing following Modular base & cover plate on existing modular PVC/GI box.3 Module |
| 64 | Fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 65 | Fixing 10A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 66 | Fixing 16A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 67 | Fixing 25A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 68 | Fixing 25A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole |
| 69 | Fixing 32A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Three Pole |
| 70 | Fixing 32A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole |
| 71 | Fixing 63A rating, 240/ 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Four Pole |
| 72 | Fixing following rating, double pole (single phase and neutral), 240 V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 73 | Fixing following rating, four pole (three phase and neutral), 415V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 74 | Fixing following rating, four pole (three phase and neutral), 415V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A |