Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in foundation in dry ordinary soil (loam clay or sand) including lift up to 1.5 meter and lead up to 30 meter and including back filling, watering and ramming of excavated earth into the trenches or into the space between the structure and the sides of foundation trenches or into the plinth with removal and disposal or surplus earth as directed by the Engineer-in-charge up to a distance of 30M from the foundation trenches:(Building) |
| 2 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 4 | Providing and laying in position cement concrete of 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level |
| 5 | Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)excluding the cost of centering and shuttering - All work up to plinth level |
| 6 | Providing and laying in position ready mixed or site batched design mix Cement Concrete of M25 grade with minimum cement Content of 330 kg /cum for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works upto plinth level |
| 7 | Providing and laying in position ready mixed or site batched design mix Cement Concrete of M25 grade with minimum cement content of 330 kg /cum for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above plinth level upto floor V level |
| 8 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 13 | Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more. for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above plinth level. |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks in Cement mortar 1:4 (1 cement : 4 coarse sand) of class designation 7.5 in foundation and plinth in |
| 15 | Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level. |
| 16 | Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 17 | 40 mm thick damp proof course with cement concrete consisting of 1 part cement 1.5 parts approved coarse sand and 3 parts approved 20mm down graded stone grit and including water proofing material etc. complete. |
| 18 | Provinding & Applying a coat of residual petroleum bitumen og Grade VG-10 of approved quality using 1.7 kg/sqm on DPC after cleaning the surface with brushes and finally with piece of cloth lighty soaked in kerosene oil. |
| 19 | 12mm thick plaster with cement mortar in proportion of 1:4 cement and sand 1.00 fineness modulous over brick work minimum thickness not to be less than 1 cm including supply of 1 material labour and T&P etc. required for proper completion of work for all floors. |
| 20 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) External Plaster height upto 10m from ground level |
| 21 | Providing and fixing Stainless steel SS grade 304, curtain rod 25 mm dia 1.20 mm thick fixed with SS screws and PVC sleeves etc., wherever necessary complete : |
| 22 | Providing Sal wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 23 | Providing and fixing M.S. grills Fixed to openings /wooden frames with rawl plugs screws etc. of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished seamless type tubes |
| 25 | Providing and fixing stainless steel ( Grade 304) GATE made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the waist slab with suitable arrangement as per approval of Engineer-incharge, |
| 26 | Providing and fixing aluminium work for For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 microndoors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 27 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width |
| 28 | Providing and fixing stainless steel (SS 304 grade) 255 X 19 mm adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. |
| 29 | Providing and fixing Powder coated minimum thickness 50 micron aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. |
| 30 | Providing and fixing Powder coated minimum thickness 50 micron aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge |
| 31 | Providing and fixing 35 mm thick flush door shutters including ISI marked Stainless Steel butt hinges with necessary screws ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 32 | Providing and fixing 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 33 | S/F of 4cm. Thick C.P teak wood fully glazed window shutters I/c supply and fixing of wooden cheats and stops and fittings including painting two coats of black Japan on all iron fittings if necessary including fixing the panes (5mm thick ). |
| 34 | Providing and fixing With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . |
| 35 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading |
| 36 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 37 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 38 | Providing and fixing SS sliding door bolt of size 200x16 mm with necessary screws etc. complete : |
| 39 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 40 | Providing and fixing SS tower bolt (plate type) size 200x10 mm with necessary screws etc. complete : |
| 41 | Providing and fixing 125mm SS handle 125 mm, with necessary screws etc. complete : |
| 42 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete |
| 43 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg and door width upto 701 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 44 | Finishing with Epoxy paint On steel work (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete |
| 45 | French spirit polishing Two or more coats on new works including a coat of wood filler |
| 46 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 48 | Distempering on New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litrewith 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 49 | Finishing walls with textured exterior paint of required shade on New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 50 | P/F Ist quality ceramic glazed wall tiles confirming to IS:15622 of approved wake, in all colour shades except burgundy. Bottol greeen, black of any size on walls over 12mm thick bed of cement mortar 1:3 and joining with grey cement slurry @ 3.3 kg/sqm including painting in white cement including supply of all material, labour and T&P etc. required for proper completion of work to be provided in toilets upto 2.1 M height. |
| 51 | P/F Rectied Glazed ceramic floor tiles of size 300x300mm of 1st quality confirming to IS:15622 in colour white Ivory, Grey fume red brown laid on 20mm thick cement mortar 1:4 including grouting the joints with white cement and matching pigments etc. Complete including supply of all completion of work of floor of toilets. |
| 52 | Providing and laying Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 53 | Providing and laying Vitrified tiles of Size 600x600 in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 54 | Grouting the joints of flooring tiles of Size 600x600 mm having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 55 | Providing and laying Vitrified tiles of Size 600x600 (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 56 | Providing and laying Glazed Vitrified tiles Matt/Antiskid finish of size 600X600mm in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 57 | Providing and injecting chemical emulsion on bottom surface and sides and the back fill in immediate contact with the foundation structure and vertical surface of the sub structure of each side @ 2 litres/Sqm specified with chlorpyrephos E.C 20% with 1% concentration for preconstruction anti termit treatment and creating a chemical barrier under and around foundation walls , column, pits back fill earth junction of wall and floors external perimeter of building surrounding pipe under apron etc. |
| 58 | Providing and laying water proofing treatment to vertical & orizontal surface of sunken slabs as per following. 1st course of cement slurry @ 4-4 kg./sqm mixed with water proofing compound as per IS 2645 rounding off the junction Iind course 0 mm cement plaster 1:3 (Cement : coarse sand) plaster founding off the junction, IIIrd course applying bot bitumen @ 7 kg. & IV th course pasting 4.00 micron polythene sheet over bitumen with 100mm overlap at junctions including cost of all material labour, T&P required for proper completion of work. |
| 59 | [Providing and laying integral cement base water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved Ly Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approve by Engineer-in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surfacewith trowel with neat cement slurry and making pattern of 300x300 mm square 3 mmdeep. (e)The whole terrace so finished shall be flooded withwater for a minimum period of two weeks for curingand for final test.\"All above operations to be done inorder and as directed and specified by the Engineerin-Charge : With average thickness of 120 mm andminimum thickness at khurra as 65mm. With average thickness of 120 mm and minimumthickness at khurra as 65 mm. |
| 60 | Stainless steel SS grade 304, brackets ( curtain rod) 25 mm dia 1.20mm thick |
| 61 | Wiring point for light /fan point / exhaust fan point with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, modular type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 62 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 63 | Wiring point for two ways light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire and two number two way modular type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 64 | Wiring point for light/ Power plug with 2x4 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe along with 1 no 4sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire . |
| 65 | Wiring points for Call bell with 1.5 sqmm.FRLSH PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire and piano type bell push or 2pin socket etc.complete in all respects.as directed including matching colour wash. |
| 66 | Supply fixing and concealing of 20mm dia. of medium class PVC conduit pipe with PVC acessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required including cost of all material,labour and T & P etc required for proper completion of work. |
| 67 | Supply & wiring of submains with two number 2.5 sq.mm FRLSH PVC insulated single core copper conductor cable in PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. |
| 68 | Supply & wiring of submains with two number 4 sq.mm FRLSH PVC insulated single core copper conductor cable in PVC conduit with 1 Number 4 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. |
| 69 | Supply & wiring of submains with two number 6 sq.mm FRLSH PVC insulated single core copper conductor cable in PVC conduit with 1 Number 6 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. |
| 70 | Supply & wiring of submains with two number 10sq.mm FRLSH PVC insulated single core copper conductor cable in PVC conduit with 1 Number 6 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. |
| 71 | Supply and Fixing of LED Batten Light with batten suitable for up to 36 watt complete including tube etc. on surface complete in all respect. CAT-AAA |
| 72 | Supply & fixing of Call Bell Of Approved Make on matching polished MDFEG board brass including connection etc. as required. |
| 73 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 74 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 75 | Supplying and fixing of one number 8 SWG G.I. wire in 15mm dia G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P other material required for proper completion of the work as directed at site. |
| 76 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 77 | Supply and fixing of 5 Amp to 32 Amp rating, 240/415V ,10KA \"C\" Curve miniature circuit breaker suitable for inductive load of single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 78 | Supplying and fixing following rating, 40Ampdouble pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 79 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T & P etc required for proper completion of work. |
| 80 | Installation of exhaust Upto 450 mm sweep fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 81 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 82 | Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
| 83 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 84 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only. The minimum clearances between bus bars shall be as follows Phase to phase - minimum 20mm ,Phase to neutral-minimum 15mm CUBICAL PANEL BOARD ( MCCB TYPE ) MAIN L.T.PANEL Incoming : one (1) No.100Amp. TPN MCCB-1No. Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. & One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.& One (1) Set of Phase Indication Lamp. us Bar :One (1) No.100 A, TPN aluminimum bus bar of suitable length Outgoing :Phase indication lamps on each outgoing to be provided.& 63 Amp. MCCB- 2 No.OR outgoing as per site requirment(AS/SLD) |
| 85 | Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules. |
| 86 | Supplying, installation, Testing & Commissioning of LED 8 to 10 wattRecessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) |
| 87 | Wiring point for H.P.M.V./ Sodium Vapour lamp with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. |
| 88 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 50 Watt. Confirming to IP 66 protection complete in all respect. CATT AAA |
| 89 | Supplying and fixing 6 way (4 + 18), Double door way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 90 | Supplying and fixing 150x75mm x 65 mm size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 91 | Supplying and fixing 200mm x 75 mm size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 92 | Providing and fixing 110mm diameter on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. |
| 93 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. Dia 110x110mm |
| 94 | Providing and fixing unplasticised 110mm -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 95 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 96 | Providing, fixing, jointing and testing in position of ISI marked 110 mm dia UV stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382. |
| 97 | Providing and fixing 15 mm nominal dia Pipes Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 98 | Providing and fixing 25 mm nominal dia Pipes Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 99 | Providing and fixing 32 mm nominal dia Pipes Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 100 | Providing and fixing stainless steel grating of approved quality & colour |
| 101 | Providing and fixing 15mm nominal bore 45 cm long unplasticised PVC connection pipe with brass unions. |
| 102 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
| 103 | Providing and fixing 25mm dia nominal bore gun metal gate valve with wheel of approved quality. |
| 104 | Providing and fixing 32mm dia nominal bore gun metal gate valve with wheel of approved quality. |
| 105 | Providing and fixing 15mm dia nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 106 | Providing and placing on terrace Circular Tank (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 107 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 108 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 109 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 110 | Providing and fixing (White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer )wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 111 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm |
| 112 | Providing and fixing P.V.C. 32 mm Flexible pipe waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 113 | Providing and fixing PTMT towel rail 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour |
| 114 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board 510x1040 mm bowl depth 250 mm as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required |
| 115 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 116 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes 80mm to 300mm diameter. |
| 117 | Providing, fixing, jointing and testing in position of ISI marked 160 mm dia UV stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382. |
| 118 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) all-round S.W. pipesincluding bed concrete as per standard design : 150mm diameter S.W. Pipe |
| 119 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 120 | Providing and laying 80mm thick factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 121 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. (M.D. -10- Circular shape 500mm internal diameter) |
| 122 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks |
| 123 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 124 | Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 125 | 5 KW off-Grid Roof top solar Power Plant including inverter, single phase with internal MPPT efficiency-99.9%, 120V, Input Voltage range-108-144V , Output Voltage range -230+2%, Battery (12V,150AH)-8 nos . Fitted at Fabricated M.S Dipped galvanized fixed structure with columns,beam and purlines, Angles and Z-section and Nuts & Bolts Designed to with stand wind speed upto 150km/hr. Completion of Work as directed by Engineer-in-charge. |
| 126 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail