Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 3 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 4 | Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed. |
| 5 | M&L Pre- paintedhot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screwscomplete all as specified and as directed. |
| 6 | M&L Pre- paintedhot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specifiedcomplete all as specified and as directed. Note:To be executed for provision of ridges and hips. |
| 7 | S&F false ceiling of designer tile ivory painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or Electra) in true horizontal level. Suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaced between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturer’s instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at centre of size 4mm depth and 4.5mm width including dismantling of old ceiling of any description complete all as specified and as directed. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 9 | M & L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to grade Fe-410-W (Gde E 250) for fixing complete all as specified and as directed. |
| 10 | S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed. |
| 11 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 12 | M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 13 | M & L for Roof treatment of RCC Roof Slab/Parapet Wall over roof in following steps :Surface Preparation: Clean all concrete surfaces free of laitance, dust, dirt, cavities, projecting nibs etc.by grinder and wire brush. Grease should be cleaned using a chemical degreaser and washed with clean water and allowed to dry. Remove all protrusions from concrete surfaces using a fine hair broom finish. Remove moss and lichen manually and treat the surface with a fungicide. Wash the surface thoroughly with clean water and allow it to dry. Standing water must be removed to prevent subsequent compromise of waterproof properties. For undulation of the existing slab shall be rectified with Shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar Renderoc SP40. Provide and Apply single coat of Lime mortar shall be applied at 1:3 ratio (Lime : sand) admixed with SBR based compound with 5-9 Liters Nitobond SBR Latex for additional layer of waterproofing, repair the covings, pot holes and any unevenness on Lime terrace roof. All around on the roof, at the parapet wall junction, an angular fillet of 50 mm X 50 mm. Free flow precision grout Conbextra GP2 poured within the leak-proof form work in accordance with the mix ratio as recommended in the technical data sheet of the manufacturer and then be sealed with an epoxy putty NITOCOTE VF. The surface is rendered to give aesthetic & visual surface finish complete all as specified and as directed. |
| 14 | Providing and carry out waterproofing treatment to sound, moisture free concrete surface using Nitoproof 600PF - Liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks upto 2 mm. System includesproper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., and application of Nitoproof WB Primer, Water dispersible epoxy primer followed bytwo coats of Nitoproof 600PF coverage @ 2.0 kg/m2to achieve 1.5 mm WFT in two coats followed by laying of separation layer of 120 gsm non-woven geotextile layer before carry out protection screed etc. complete including all tools and tackles as per manufacturer’s specification. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises etc. complete as per design, drawing & instructions of EIC. Cost of 120 gsm non-woven geotextile and 75mm Screed concrete shall be paid separately. |
| 15 | Supply & Laying Geotextiles of 120 Gsm over the waterproofing coating to avoid damage during screed casting. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by EIC. |
| 16 | Supply & laying of maximum 75 mm thick (at RW outlet) protective screed/Plaster over the waterproof coating at proportion of 1:2:4 admixed with suitable integral waterproofing compound conforming IS 2645:2003 @ 200ml per bag of cement and reinforced with PP fibres with proper slope towards RW pipes. Green stage saw cutting on the screed will be done in panels (3mt X3mt) with a groove size of 10mm X 15mm. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by EIC. |
| 17 | Demolition ofplain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level)complete all as specified and as directed. |
| 18 | M&L for PCC 1:4:8Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 19 | M & L for PCC 1:2:4, type B0 (using 12.5 mm gradedcrushed stone aggregate) as in benching and coping, pole coping,cills, hold fasts, fixing of post, water trough etc. includingnecessary formwork (straight or curved) complete all as specified and as directed. |
| 20 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for all as specified and as directed. |
| 21 | M & L for precast RCC cover slab,1:1.5:3 type A-1,(Using 20 mm graded crushed stone aggregate ) as in drain/manhole cover slab etc., and set in cement mortar 1:4 including necessary form work complete all as specified and as directed. |
| 22 | M & L for mild steelTMT bars 10 mm dia and overcut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 23 | Demolition of brick or stone masonry work built in cement mortarincluding all quoins, arches, pillars etc complete all as specified and as directed. |
| 24 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 25 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 26 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 27 | M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 28 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thickmixed with water proofing compound @ 200Mlper bag(50Kg) of cement or as per manufacture\"s instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note :Water proofing compoundwill be measured and paid separately as \"Supply only\". |
| 29 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 30 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces using Airless Paint Primer Sprayer using smart technique, on newly plastered surface of wall, cornices complete all as specified and as directed . |
| 31 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm using Airless Paint Primer Sprayer using smart technique on old surfaces of wall including complete removal of existingold treatmentincluding, preparation ofsurfacesof wall, cornicesby wire brushing, rubbing down complete all as specified and as directed . |
| 32 | M & L for preparation of newly plastered surfaces of wallsand applying one coat of alkali resistant primer over a coat of 1.5mm thick (average) wall care putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil bound distempercomplete all specified and as directed. |
| 33 | M&Lfor complete removal of existing finishes/treatment of wall and applying two coat ofoil bound distemper over one coat of primer including 1.5mm thick(average) wall care putty complete all as specified and as directe. |
| 34 | M&Lfor complete removal of existing finishes/treatment of wall and applying two coat ofoil bound distemper over one coat of primer complete all as specified and as directe. |
| 35 | M&L for preparation of old decorated surfaces of wall and applying one coat of oil bound distemper using roller techniquecomplete all as specified and as directed. |
| 36 | M&L for preparation of old decorated surfaces of ceiling and applying one coat of oil bound distemper using roller techniquecomplete all as specified and as directed. |
| 37 | M & L for Smart Care Hydrock, Xtreme is a single component, ready-to use, film forming interior waterproofing solution that provides best-in-class solution to interior waterproofing problems like dampness and efflorescence leakages on account interior or exterior plumbing issues, nahani traps, chajjas, rain drains, sanitary drains etc. Identify internal live leakage with the help of thermal imaging and take appropriate preparation steps for plumbing repair, cracks in windows or exterior walls, drains etc.Surface should be in SSD condition prior to the application of SmartCare Hydroloc Xtreme. Application: a) Apply first coat of SmartCare Hydroloc Xtreme at 10% dilution with a forced coverage of 2.98 to 3.36 sq.m/L from skirting to the affected area, covering an additional one ft distance across all sides of affected area. Allow it to dry for 6-8 hrs. b) Apply Second coat of SmartCare Hydroloc Xtreme (no dilution) with coverage of 2.98 to 3.36 sq.m/L perpendicular to first coat. Allow it to dry for 6-8 hrs all as specified and directed by Manufacturer instructions and as guided by Eng-in-charge. |
| 38 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing complete all as specified and directed. |
| 39 | M&L for 25 mm thick PCC 1:2:4, type B-0, (using 12.5 mm graded crushed stone aggregate) as in levelling Course, floor/paving ect and finished the surface even and fair complete all as specified and as directed. |
| 40 | M&L for colouredjoint free non-skidceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid in floors etc.over and including 15 mm thick screed bedin cement motar 1:4, setand jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles,complete all as specified and as directed. |
| 41 | M&L for coloured joint free non skid ceramictiles 7 to 8mm thick (square / rectangular )area of each tiles exc 0.18 sqm but not exceeding 0.38 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with colouredtilesover and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 42 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 43 | M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thickrenderingincement mortar 1:4 complete all as specified and as directed. |
| 44 | M&L for Granite (of any colour) tile 19-20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone with grinding and polishing over and including 15 mm thick screed bed in cement mortar 1:4 including dismantling of oldtile of any description complete all as specified and as directed. |
| 45 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and as directed. |
| 46 | M & L for green marble work 18mm to 20mm thick (table rubbedand polished)in steps,jambs,pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over and including 10 mm thick rendering in cement mortar (1:3) including rubbing and polishing complete all as specified and as directed. |
| 47 | Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqmeach (without taking off shutters from frame) complete all as specified anddirected. |
| 48 | Taking down chowkats orframe with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm complete all as specified and directed. |
| 49 | Taking down shutter of any descriptionarea exc 1 sqm but n exc 2 Sqm each including builders hardwarecomplete all as specified and as directed. |
| 50 | Taking down shutter of any descriptionarea n.exc 1 sqmeach including builders hardware complete all as specified and as directed. |
| 51 | Taking down shutter of any description exc 1 Sqm n exc 2 Sqm each and refixing in the same opening after necessary repaircomplete all as specified and as directed. |
| 52 | M & L for 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints complete all as specified and as directed. |
| 53 | S & F factory made solid PVC door frameof size 40mm x 47mm made out of 5 mm thickplain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 54 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 55 | S&F HDHMR Door 32mm made from Exterior grade High density fibre (HDF) Homogeneous Board of lignocellulosic fibrous material - specifically \" Plantation Timbers\" like eucalyptus, processed through drum De-barker system to remove slug, mud, sand grit Bark & Bad Fibre to remove the big fibre and glue lumps pass through the Z shifter. Manufactured with Homogeneous core, without layers by the Mat forming technology, bonded through inhouse pre-pared glue, Continuous European pressed by 192 cylinder to control multipoint pressure and temperature for uniform density profile across length & width, European resin blow line blending for uniform distribution of Resin with fibre. Online blow detector, online thickness calibration for uniform thickness control, termite and Borer resistance, router exterior grade product with moisture Resistance, calibrated as per grade IS:12406:2003 & Eco marked labelling by ISI for environmentally friendly as per Norms of Ministry of Environment, lGBC Membership & FSC certified used for Main door, internal door of House, office and Commercial Applications outer Finishing for CNC routing Working, Painting, polishing etc. Standard Height of 7\"/8\" ft and width of 27\"/30\"/33\"/36\"/39\"/42\"45\" in thickness 30mm/32mm, size 8\"/4\" in thickness of 22/30mm for panel door and shaft door application complete all as specified and as directed. |
| 56 | S & F 30 mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided in to squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc complete all as specified and as directed. |
| 57 | M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 58 | M&Lfor preparation of old painted surfaces of wood or wood based materials of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 59 | S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 60 | S & F 75 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 61 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 62 | S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 63 | S&F 150mmsize aluminium handles, cast type, anodised complete all as specified and as directed. |
| 64 | S&F 100mmsize aluminium handles, cast type, anodised complete all as specified and as directed. |
| 65 | S & F 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionor cast aluminum alloy complete all as specified and as directed. |
| 66 | S & F floor door stopper of aluminium alloy body and tongue, overall length of cover plate 150 mm anodised with hard drawn steel spring, fixed in floors complete all as specified and as directed. |
| 67 | S & F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 68 | S & F in repairs, stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 69 | M & L for prelaminated particle board 12mm thick, exterior grade, prelaminated both side with decorative choice lamination fixed with screws to timber or aluminium frame work including dismantling of old board complete all as specified and as directed. |
| 70 | S&F 18/19mm thick solid PVC composite sheet, prelaminated on front side and plain matching dark shade laminated background as in kitchen cabinet shutters, backing, sides, top/bottom, etc, fixed with SS flush screws including necessary cutting for required shape, rebate, hinges, hooks, etc and fixing only of self closing hinges, wall hanging hooks, magnetic locks, handles, etc complete all as specified and as directed.(Notes:- (i) Necessary hinges, hooks, handles & locks shall be measured & paid separately as \"Supply Only\" under relevant item.(ii) Labour charges for \"supply only\" items are deemed to be included with quoted rates) |
| 71 | Supply only heavy duty stainless steel slip on hinges, self closing type with opening full overlay or 105°, suitable for 25mm thick shutter of maximum size 850mm x 550mm complete all as specified and as directed. |
| 72 | Supply only Ergonomically designed powder coated Aluminium anodised handle, finger pull type, suitable for 19mm thick shutter, size 14mm x 43mm complete including finish as approved complete all as specified and as directed. |
| 73 | Supply only heavy duty Slim Nickel plated Stainless steel magnetic catch (L shape) with strong earth magnet, size 11mm x 35mm x 4mm complete all as specified and as directed. |
| 74 | S&FPowder coated (minimum thickness of powder coating 50 micron) anodised aluminium frames for door, windows, ventilators, partitions etc. with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 75 | S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters (sliding type), aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc. complete all as specified and as directed. |
| 76 | S&F 4 mm thick Sheet glass, selected quality glazing with rubber beading n exc. 0.5 sqm in each pane with solar coated film 25 micron reflective type complete all as specified and as directed. |
| 77 | S&F 4mm thick Sheet glass, selected quality glazing with rubber beading n exc. 0.5 sqm in each pane with solar coated film 25 micron reflective type complete all as specified and as directed. |
| 78 | S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty or rubber beading in square n exc 0.5 sqm in each pane including hacking out old broken glass of any thickness, size quality or description complete all as specified and as directed. |
| 79 | S & F aluminium door closer (extruded section)bodyhydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and complete all as specified and as directed. |
| 80 | S & F in repairs, Harrison rails, anodized aluminium alloy with fixing brackets, stops, rollers etc complete all as specified and as directed. |
| 81 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes exc 250 & n.exc 500 litre capacity, etc complete all as specified and as directed. |
| 82 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes exc 500 & n.exc 1000 litre capacity, etc complete all as specified and as directed. |
| 83 | S and F Rotational molded PVC water storage tanks 500 litre capacity ( cylindrical vertical with closed top) hoisted and fixed in position fixed withfloat valve of PVC 20mm dia high pressure with polythene float and fly nut and 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or brass including dismantlingof oldPVC tank of any description complete all as specified and as directed. |
| 84 | S and F Rotational molded PVC water storage tanks 1000 litre capacity ( cylindrical vertical with closed top) hoisted and fixed in position fixed withfloat valve of PVC 20mm dia high pressure with polythene float and fly nut and 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or brass including dismantlingof oldPVC tank of any description complete all as specified and as directed. |
| 85 | S & F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors including dismantling of old tubing complete all as specified and as directed. |
| 86 | Cutting chases, pinning in, making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunsheds, shelves, lintel etc and cutting chases for concealed water tubing or concealed conduit wiring etc n. exc. 10 cm width or girth complete all as specified and as directed. |
| 87 | S&F in repairs, bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed. |
| 88 | S&F in repairs,stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe. |
| 89 | S&F in repairs, 15mm bore dia of concealed stop valves cast copper alloychromium plated, fancy type with long shank and cup screwed down high presure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 90 | S & Fin repairs, chromium plated wall mixer three in one system with wall flange (Provision for Overhead shower & hand shower)for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed.Make : Prayag, Cat No 9380or equivalent in or equivalent in Jaquar / Hindware/parryware |
| 91 | S & F in repairs, 125 mm, dia chromium plated, swivel type shower rose suitable for fixing 15 mm bore iron pipe complete all as specified and as directed. |
| 92 | S&F in repairs, tubular towel Rail of 20mm dia and 60cm in length, D shaped, with brass chromium platedbrackets complete all as specified and as directed. |
| 93 | S & F in repairs, toilet paper holder chromium plated fixed to wall with chromium plated brass screw complete all as specified and as directed. |
| 94 | S & Fin repairs, Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 95 | S & F600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 96 | S & F in repairs, vitreous china wash hand basin, white flat back size 550 mm x 400 mm including brackets and pillar tap, 15 mm bore chromium plated, cast copper alloy with capstan heads, 32 mm waste coupling brass chromium platedsuitable for wash hand basins, with long screwed shanks and fly nuts andPVC waste pipe,15mm dia 600mm longPVC connection pipe complete all as specified and as directed. |
| 97 | S & F inrepairs, Vitreous China SquattingPan\"Orissa pattern\" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed. |
| 98 | S & F inrepairs, vitreous china wash down water closet (padestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for padestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed. |
| 99 | S&F in repairs, 10 Litres capacity PVC valveless syphonic action type, flushing cistern, low level, white or coloured, with inlet, ball valve, float and handle including brackets,PVC connection pipe 15mm dia, 450mm long etc complete all as specified and as directed. |
| 100 | S & F in repairs,PVC connection pipe 15mm bore and600mm long with PVC PTMT nuts at each ends with rubber washers complete all as specified and directed. |
| 101 | S & F in repairs,PVC connection pipe 15mm bore and450mm long with PVC PTMT nuts at each ends with rubber washers complete all as specified and directed. |
| 102 | S & F in repairs, chromium plated waste coupling 32mm (half or full thread) complete all as specified and as directed. |
| 103 | S&F in repairs, 100 mm dia Cast ironP or S trap complete all as specified and as directed. |
| 104 | S&F in repairs, 32 mm low density polyethylene pipes (LDPE) of pressure rating 6 kgf/sqcm fixed to walls ceiling or in floor etc. complete all as specified and as directed. |
| 105 | S&F75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 106 | S&F in repairs, Grating doom 100 mm dia of PTMT (min. weight 25 gms) complete all as specified and as directed. |
| 107 | Dismantling PVC drain pipes any size and in any position including all fittings complete all as specified and as directed. |
| 108 | S&F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wallcomplete all as specified and as directed. |
| 109 | S&F 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wallcomplete all as specified and as directed. |
| 110 | S&F 110 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed |
| 111 | S&F 75 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed |
| 112 | S&F 110mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed. |
| 113 | S&F 75mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed. |
| 114 | Demolition and breaking up drain pipe (Salt glazed ware, AC or reinforced concrete) set in cement mortar for 150mm bore pipe complete all as specifiec and as directed. |
| 115 | M&L for 150mm bore salt glazed stone ware drain pipe grade \"A\" laid in trenches and jointed in cement mortar complete all as specifiec and as directed. |
| 116 | M&L for pcc 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in bed for drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 117 | Dismantling of 100mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortarcomplete all as specified and as directed. |
| 118 | S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed to wall complete all as specified and as directed. |
| 119 | Fixing Only serviceable 100mm cast iron cast waste and vent pipes obtain from dismantling of old pipes complete all as specified and directed. |
| 120 | S&F 100mm bore cast iron bends (any radios), diminishing pieces or tapers (larger bore measured) fitted with oval access doors complete all as specified and directed. |
| 121 | S&F 100mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access door complete all as specified and directed. |
| 122 | S&F 100mm bore cast iron branch piece, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access door complete all as specified and directed. |
| 123 | S&F 100mm bore cast iron cowls complete all as specified and directed. |
| 124 | S & F GI tubing 80 mm bore, medium grade with all fittings, laid in trenches including taking up/down old steel tubing with fittings complete all as specified and as directed. Note : For Item No 125 to 128 Earth work shall be measured and paid separately under respective item. |
| 125 | S & F GI tubing 50 mm bore, medium grade with all fittings, laid in trenches including taking up/down old steel tubing with fittings complete all as specified and as directed. |
| 126 | S & F GI tubing 40 mm bore, medium grade with all fittings, laid in trenches including taking up/down old steel tubing with fittings complete all as specified and as directed. |
| 127 | S&F GI tubing 25 mm bore, medium grade with all fittings and fixed complete laid in trenches including taking up/down old steel tubing with fittings complete all as specified and as directed. |
| 128 | S & F in repairs, 50mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel headscrewed both ends for iron pipecomplete all as specified and as directed. |
| 129 | S & F in repairs, 40mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel headscrewed both ends for iron pipecomplete all as specified and as directed. |
| 130 | S & F in repairs, 25mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel headscrewed both ends for iron pipecomplete all as specified and as directed. |
| 131 | Repairing of valve pit chamber after taking down cracked plaster and perforated MS cover and angle and complete with new plaster inside and of valve pit chamber of any description max upto size of 1.2 M X 1.2 M X 1 M and change of MS cover and angle. The steel surfaces shall be painted with to coats black bituminous paint over a coat of red oxide primer including complete removal of old paint complete all as specified and as directed. |
| 132 | M&L for disconnecting the submersible/centrifugal/Booster pump and motor upto 2HP to 5 HPafter disconnection of mechanical tyre coupling, suction/discharge pipe line and unbolting from foundation base plateloading/unloading the pump and motor to the vehicleand transportation to workshop for repair/replacement/rewinding with super enamelled copper conductor wires 22 gauge, maintenance and including dismantle & re-assembling the pump setting the impeller & housing for smooth running, replacement of packing gaskets etc. after repair/replacement/maintenance transportation back from workshop to site, including re-assembling the same, recoupling the pump with motor on base frame, checking the alignment with motor, testing & commissioning on completion and checking upto the satisfaction of Engr-in-Charge.Note :- [i] unserviceable spares parts of pump set like bearing, packing, is consider in quoted rate. |
| 133 | All as per item No 132 here in before but Pumpset Upto 2 HPcomplete all as specified and as directed. |
| 134 | M& L for attending external water supply complain like no water in tank, pipe line breakdown/pipe line leakage and pipe line blockage in bldgs in and including replacing of Tee, elbow, sockets, nipple & foot valve etc as per requirement in pipe line 20 to 25 mm dia including necessary excavation earth work if required complete all as specified and as directed. Note : complain like no water in tank to be attained within 3-4 hrs otherwise necessary compensation may be deducted . |
| 135 | All as per item No 134 here in before but 40 to 65 mm dia |
| 136 | All as per item No 134 here in before but 80-250 mm dia |
| 137 | Collecting the sample of water of required quantity in bottle/kit from different point submitted duly levelled the source through Engineer-in-Charge for forwarding to the test house and carrying out chemical testing of water for iron, PH value, hardness, turbidity, chloride, fluoride, arsenic test and submitting the test reportin triplicate done from NABL & ISO 17025 accredited laboratory/ National Test House/Govt. approved laboratory complete all as specified and as directed.NOTE: Sample of water shall be collected and tested quarterly. |
| 138 | Collecting the sample of water of required quantity in bottle/kit from different point submitted duly levelled the source through Engineer-in-Charge for forwarding to the test house and carrying out bacteriological test for water sample quarterly and submitting the test report in triplicate done from NABL & ISO17025 accredited laboratory / National test house/Govt. approved laboratory complete all as specified and as directed.NOTE: Sample of water shall be collected and tested quarterly. |
| 139 | M&L for taking down old rusted perforated GI water pipe line of sizes 40-80 mm and fixing with new one supplied by Dept free for fixing under Sch \"B\". Note:(1) fittings and fixtures like tee, elbow, bend, union, plug is considered in quoted rate.(2) Excavation, filling and removing will be measured and paid separately under respective item. |
| 140 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 141 | M&L for concealed point wiring with PVC insulated unsheathed multistranded FRLSH copper conductor in and including PVC conduitwith cable 1.5 Sqmm size 1100 volts grade conforming to IS:694 and terminate to flush box of required size suitable mounting modular switches and sockets including single core multi stranded FRLSH copper conductor 1.5 Sqmm PVC insulated cable as earth wire connected to earth and common earth dollydrawn in same concealed conduit for one light/fan/wall fan/exhaust fan/bellpoint controlled by one No, one way 5/6/10 Amp switch complete all as specified and as directed.Note: Cutting chases for concealed type point wiring including making good the same with plaster/putty and Modular boxes with cover plate will bedeemed to beincluded in quoted rate. |
| 142 | Allas per item serial No 141 here-in-before butfor One light point controlled by 2- two way5/10 Amps switch. |
| 143 | Allas per item serial No 141 here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on independent board. |
| 144 | Allas per item serial No 141here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on same board with other switches. |
| 145 | All as per item serial No 141 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15/20 Amp socket outlet on independent board. |
| 146 | Allas per item serial No 145here-in-before butfor One 3 pin 15/20 Amp switch socket outlet on same board with other switches. |
| 147 | All as per item serial No 145 here-in-before but with 4.0 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 4.0 Sqmm cable for 6 pin 15/20 Amp socket outlet on independent board. |
| 148 | S&F Modular switch 1 way 6/10 Amp, 1 module, single pole240 volts complete all as specified and as directed. |
| 149 | S&F Modular switch 2 way 6/10 Amp, 1 module240 volts complete all as specified and as directed. |
| 150 | S&F Modular bell push, flush type, 6/10 Amp 240 volt complete all as specified and as directed. |
| 151 | S&F Modular switch 1 way 16/20 Amp, 1 module complete all as specified and directed. |
| 152 | S&F Modular type socket shuttered type, 6/10 Amp, 2/3 Pin combined 2 module, 240V,ACISI Marked complete all as specified and as directed. |
| 153 | S&FModular socket shuttered type, 6/16 Amp or 10/20 Amp, 2/3 pin combined 2 module 240V,ACISI Marked complete all as specified and as directed. |
| 154 | S&FModular type step fan speed regulator 100/120W, 2 module, 230volts, AC, 360 degree rotation 0 to 4 steps,ISI Markedcomplete all as specified and as directed. |
| 155 | S&F lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed. |
| 156 | S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 157 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLSH cable, 1100 volts grade IS-694marked, with multistranded copper conductors andsingle core multi stranded FRLSH earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan/bell point controlled by one number one way 5 /6/10 Amp switch complete all as specified and as directed. |
| 158 | Allas per item serial No 157 here-in-before butfor One light point controlled by 2- two way5/6/10 Amps switch. |
| 159 | Allas per item serial No 157 here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on independent board. |
| 160 | Allas per item serial No 157here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on same board with other switches. |
| 161 | All as per item serial No 157 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15/20 Amp socket outlet on independent board. |
| 162 | Allas per item serial No 161here-in-before butfor One 3 pin 15/20 Amp switch socket outlet on same board with other switches. |
| 163 | S & F switch piano, flush type single pole one way 5/6 Amps 230/240 volt complete all as specified and as directed. |
| 164 | S & F switch piano, flush type single pole two way 5/6 Amps 230 volt complete all as specified and as directed. |
| 165 | S&F bell push, flush type, 5/6 Amps 230/240 volt complete all as specified and as directed. |
| 166 | S&F socket outlet 3 pin, 2-in-1, 5/6 Amps, flush type240 volts complete all as specified and as directed |
| 167 | S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type 240 volts complete all as specified and as directed |
| 168 | S & F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp or 6 &16 Amp flush type complete all as specified and as directed. |
| 169 | S & F stepped type electronic fan regulator, flush type complete all as specified and as directed. |
| 170 | S & F call bellMulti music type, 230 Volts AC single pole,ISI marked,complete all as specified and as directed. |
| 171 | S&F integral LED 4ft luminaire of CRCA / extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a 20 Watt LED with colour consistency SDCM< 5,CRI> 80 and colour temperature - 4000 to 6500K, Luminaire shall be designed to emit at least 2400 nominal lumens at a system efficacy of at-least 120 lumen/watt, power consumption should not be more than 20W (+5%). the life of fixture (including Driver): 50000 burning Hrs.@ L70B50 Lumen maintenance @ design ambient temp 50 deg C. The electronic driver used shall have a power factor >0.95 and THD < 10% suitable for an operating voltage range of 150-270V AC current Ripple<5% internal surge protection should be minimum 4KV, electrical insulation class should be Class I &driver should be of class B serviceability. The luminaire should be at least IP20 & IK02 rated. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for luminaire manufacturer along along with sample approval. The LED Luminaire & It\"s driver both should be BIS registered contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver including dismantling of old tube light fitting of any descriptioncomplete all as specified and as directed. |
| 172 | S&F integral / batten LED 2ft, 10watt 220 V, luminaire made of CRCA / extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit at least minimum 1200 system lumens at a system efficacy of at-least 120 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredit lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver including dismantling of old tube light fitting of any description complete all as specified and as directed. |
| 173 | S&F in repairs Environmentally friendly, ultra modern, energy saving, Pressure die cast housing 10 W LED bulkhead with IP66 protection and IK09 impact resistance suitable for surface and wall mounting applications comprising of high brightness LEDs complete all as specified and as directed.Make:- Philips Model : WT202W LED10S CW PSU S3 PC/WT202W LED10S NW PSU S3 PC or Havells Model HEXAFT10WLED857SSYMBOPC or equivalent Model of make Crompton /Bajaj/Wipro. |
| 174 | S&F in repairs, 15W recess mounted downlighter pressure die-cast aluminium luminaire in powder coated white finish in roundprofile with optimized heat sink for efficient heat dissipation and integrated driver complete all as specified and as directed.Make: HavellsModel : VIBETRENDRDDLR15WLED840S/VIBETRENDSQDLR15WLED840SPhilipsModel : DN296B LED15S-6500 PSE WH S2 9405/ DN496 LED15S-6500 PSU WH orequivalent model in make of Crompton/Bajaj |
| 175 | S&F in repairs , LED luminaire 600 mm x 600 mm, 36 watts, 220 Volts, AC, recessed/surface, white/warm type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver andflexible copper conductor cable of suitable size complete all as specified and as directed. |
| 176 | Taking down carefully ceiling fans at any height of any sweep/make/model after disconnecting electric connection and dismantling andopening the body of ceiling fan and examine for repairs including servicing, overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adaptor, screws, nuts, spring washers for blade/body etc and replacement of components/accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts which will be measured separately under relevant items as supply onlyincluding hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed. Including making good the existing places where required.Note: - (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only. (ii)Rewinding of fan motor, painting will be measured and paid separately under relevant item of schedule.(iii) Labour element for fixing of spare parts and removing old unserviceable items will be deemed to be included in quoted rate. |
| 177 | Allas per item serial No 176here-in-before butbutexhaust fan of PVC/metalbody 250mm sweep. |
| 178 | Allas per item serial No 176here-in-before butbutexhaust fan of metalbody 300mm sweep. |
| 179 | Supply only condenser ISI marked 230/240/250 volts AC 2.5 Mfd suitable for ceiling fan complete all as specified and as directed. Make : Usha/Asian/EPCOS/Universal. |
| 180 | Supply only capacitor 3.15 mfd,240volts 50Hzcomplete all as specified and as directed. Make : Epcos/Universal/tipcon/CG |
| 181 | Supply only ball bearing Model No 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI |
| 182 | Supply onlyball bearingModel No 6203/6204 complete all as specified and as directed. Make : NBC/SKF/SBBI |
| 183 | Taking down storage type water heater (Geyser)25 litre capacity of any make/model/type from existing wall after disconnecting of electric and water supply connections and keeping the same in safe custody for carry out repairs/replacement of unserviceable spare parts & components such as heating element, thermostat, pilot lamps with wiring, insulating glass wool, thermal cut out, pressure release valve, safety valve, apparatus plate assembly etc andexamine water tightness of inner storage tank after cleaning and renewal of rubber washer/gasket and nut, bolts and washers etcand adjust to required range of thermostat controland assembling all parts/ accessories includingfixing back in same location after connecting up of water & electric connections and testing for its satisfactory functioning complete all as specified and as directed. Note: - (i) Spares will be measured and paid separately under relevant item of schedule as supply only(ii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate. |
| 184 | Supply only heating element 2.0Kw with round/triangular base, push and clamp fixing type suitable for 25 Liters capacity geysers complete all as specified and as directed. |
| 185 | Supply only thermostat switch for 25 litre Geyser, 230 V, 30 degree to 90 degree centigradetemp range to be set at 70 degree to50 degreecenti grade suitable for water heater complete all as specified and as directed. |
| 186 | Supply only apparatus plate assembly suitable for storage type water heater (geyser) 25 litre capacity complete all as specified and as directed. |
| 187 | Supplyonly copper container suitable for Geyser 25 litre with MS collar complete all as specified and as directed. |
| 188 | S&F in repairs, heavy duty PVC connection pipe 15 mm bore dia, 600 mm long, suitable for hot & cold water supply with chromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15mm bore dia complete all as specified and as directed. |
| 189 | S&F exhaust fan of any type/size sturdy engineering plastic exhaust fan 250 mm sweep,1200 rpm, 240Volts, AC, 50Hz as approved colourand connecting of electrical connections and testing including wall cutting finishing and fixing arrangements including dismantling of old exhaust fan complete all as specified and as directed. |
| 190 | S&F in repairs, polycarbonate Plug top 15 Amps, 3 pin 240 Volts complete all as specified and as directed. |
| 191 | M&L for galvanized iron tubing 40 mm dia \"\"medium grade\"\" in any length including embedded in wall two ends duly welded MS holdfast at two ends of GI pipe and providing PCC in wall and making good distributed surfaces including dismantling of old tube complete all as specified and as directed. |
| 192 | S&F in repairs,sheet metal enclosure double door with metal type AD/DD,415 volts AC, VTPN DB, 8 way+24 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bar and MCCB incomer, and MCB SP /TP as outgoing and complete for IP54 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 193 | S&F in repairs, sheet metal enclosure double door with metal type AD/DD 415 volts AC, TPN, DB, 8way, 8+24 modules, flush mounting with 100 amps copper busbar, 2 neutral/earth bar and MCB incomer, MCB TPN/FP, and MCB SP as outgoing and complete for IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 194 | S & F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way, double door, protection class IP-43 with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed . Make :- Legrand Cat No 5076 70 or L&K Cat No DETPE004DDS or equivalent. model in Siemens / Schneider/Havells |
| 195 | S & F in repairs, single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.Make:- L&K Cat No :DESPN004DDS, or Legrand Cat No :5076 10 or equivalent model of make Siemens/Schnider/HagerABB/Havells |
| 196 | S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.Make :- Legrand Cat No 5076 11 orL&K Cat No DESPN008DDS or equivalent model in Siemens / Schneider/Havells. |
| 197 | S&FMCB four pole40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified and as directed.Make:- L&K Cat No :BB40400C to BB40630C, or Legrand Cat No 4086 81 to 4086 83 or equivalent model of make Siemens/Schnider/HagerABB/Havells |
| 198 | S&F MCBs, SPN 6 to 32 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 199 | S&FMCBs, SP 6 to 32 Amps, 10 KA, \"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 200 | S & F in repairs, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240V complete all as specified and as directed.Make:- Legrand cat No.5078 11 20A SP,2P+E/ Hager cat ref no.VYA120C / Havells Cat No.DHDPUSN020/L&T Cat No.DBMPS220SDor as approved make |
| 201 | S&F in repairs, MCCB 4 pole, 415V, 100 Amps rupturing capacity 16 KA thermal magnetic based on LT panel/feeder pillar complete all as specified and as directed. |
| 202 | M&L for Sub main wiring with 2 runs of 10 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 10 Sqmm cable and 1 run of 10 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 203 | M&L for Sub main wiring with 2 runs of 6 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 204 | M&L for Sub main wiring with 2 runs of 4 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 205 | S&F GI bracket pipe of size 40 mm dia medium grade of 1.2 metre long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixedon PCC & Steel poles/on wall surfaces and including suitable fabricate MS flat ironclamps of 30X6 mm thick-02 Nossuitable for fixing any place of poles with nuts, bolts & washers or grouting on wall etc and Including taking down old one complete all as specified and as directed. |
| 206 | S & F in repairs, LED security light of capacity 60 Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 complete all as specified and as directed. Model VISTA P 78L WH PO PC SD Make Bajaj orCat Part No. ENDURASUNDOWNNXTSL60WLEDCWPASYBOPC/ Make Havellsor equivalent in Philips/ Crompton/Wipro/Bajaj. |
| 207 | M & Lfor earthing in replacement complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cm X 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I including dismantling of old earthing complete all as specified and as directed. |
| 208 | Dismantling of old unserviceable/ ACSR conductors of any size from overhead lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and as directed. |
| 209 | Laying only LT UG cable of size 6 Sqmm 4 core to 10 sqmm 4 core complete all as specified and directed by Engr-in-charge.Note:- (i)Cable will be issued from MES store Yard for Free for Laying only under Sch \"B\".(ii) For item no 209 to 211 Earth work shall be measured and paid separately under respective item. |
| 210 | Laying only LT UG cable 25 Sqmm 3.5/4 coreto 95 sqmm 3.5 corecomplete all as specified and as directed.Note:-(i)Cable will be issued from MES store Yard for Free for Laying only under Sch \"B\". |
| 211 | Laying only LT UG cable 120 Sqmm to 185sqmm3.5 core complete all as specified and as directed.Note:-(i)Cable will be issued from MES store Yard for Free for Laying only under Sch \"B\". |
| 212 | M&L for sand cushioning with dry river sand in trenches for cushioning of underground cable including spreading, leveling, punning down the thickness of sand upto 18cm and consolidated complete all as specified and as directed.Note: Punned thickness of sand cushioning will be measured and paid. |
| 213 | M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable forprotection of LT cable complete all as specified and as directed. |
| 214 | M&L for boring of hole under roads (minimum 1m bellow the road surface) with mechanical arrangement upto 80 mm dia without disturbing the top surface of the road for passing the water pipes/UG cable across the road complete all as specified and as directed. |
| 215 | Supply and laying GI tubing 50mm bore light grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed. |
| 216 | Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed. |
| 217 | S&F cable junction box weather & fire proof out door type installation of approved size, hinged/screwed type made of SMC plastic single door with incoming and outgoing connector/terminals suitable for 6 to 16 sqmm cable along with MCB SP 6 Amp & MS Clamp complete all as specified and as directed.Make: - hensel cat No. KF 1616B as equivalent approved make in Sintex. |
| 218 | S&F in repairs, MCCB 4 pole, 415V, 250 Amps rupturing capacity 36 KA thermal magnetic based on LT panel/feeder pillar complete all as specified and as directed. |
| 219 | S&F in repairs, MCCB 4 pole, 415V, 200 Amps rupturing capacity 36 KA thermal magnetic based on LT panel/feeder pillar complete all as specified and as directed. |
| 220 | Taking out split type air conditionersindoor and outdoor units completefor repair and overhauling of capacity 1.5/2.0 TRof any make/type after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacingthe spares like relay assembly, relay contactor, capacitors, thermostat, fan motor with blades & blower fan motor with blades, unserviceable strainer air filters cum drieretc after taking down of old materials as requiredand also including connecting of refrigerant pipe, drain pipe and also charging of refrigerant gas andfixing back in its original location after satisfying testing complete all as specified and directed.Note :- (i) Spare parts will be measured and paid separately as \"Supply only\". (ii) Refrigerant gas will be measured and paid separately as \"Supply only\".(iii) Lobour charge for taking down and fixing of \" Supply only\" materials are deemed to be included with quoted rate. |
| 221 | M&L for leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in split AC upto 1.5/2TR capacity and testing complete all as specified and directed. Note:- Refrigerant gaswill be paid separately under respective item. |
| 222 | Supply only for starting capacitor of upto 80- 100 MFDfor split type air conditioners upto 2 TR capacity complete all as specified and as directed. |
| 223 | Supply only for running capacitor of upto 30-60 MFD for split type air conditioners complete all as specified and as directed. |
| 224 | Supply only fan motor with blade suitable for out door unit split type air conditioner up to 2 TR capacity (as per sample) complete all as specified and as directed. |
| 225 | Supply only blower fan motor with blade for out door unit including capacitor, single phase, 230V, 50Hz, ISI Marked for split type air conditioner upto 2 TR capacity (as per sample) complete all as specified and as directed. |
| 226 | Supply only relay assembly suitable for split type air conditioner 1.5/2.0 TR capacity (as per sample) complete all as specified and as directed. |
| 227 | S&F in repairs, swing motor of 1.5/2.0 TR capacity split type AC (as per sample) complete all as specified and as directed. |
| 228 | S&F in repairs, control circuit (PCB) device suitable for 1.5/2.0 Ton Split /Window type AC complete all as specified and as directed. |
| 229 | S&F in repairs, control circuit (PCB)device suitable for 1.5/2.0 Ton inverter type Split /Window typeAC complete all as specified and as directed. |
| 230 | S&F for rotary type sealed compressor of split type air conditioner of 1.5TR capacity including initial filling of refrigerant gas to the required pressure and testing after completion including dismantling of old unserviceable compressor complete all as specified and as directed. |
| 231 | S&F in repairs, copper tube 1/2\" dia complete all as specified and as directed. |
| 232 | S&F in repairs, copper tube 1/4\" dia complete all as specified anddirected. |
| 233 | S&F in repairs, copper tube 5/8\" dia complete all as specified anddirected. |
| 234 | S&F MS wall bracket suitable for fixing of outdoor unit of split type Air Conditioner with necessary nuts, bolts & washers and making good disturbed surfaces to match with the existing including dismantling of old wall Bracket complete all as specified and as directed. |
| 235 | Supply and topping up of refrigerant gas (R-32/R-134a or superior) suitable for split/window AC/Refrigerator/deep freezer complete all as specified and as directed. |
| 236 | Removing the old acoustic padding and supply and fix new acoustic (\"U\" form) padding with all packing material for refrigerant tubing from outdoor unit to indoor unit after dismantling copper tube and re fix again complete all as specified and as directed. |
| 237 | S&F PVC pipe 15 mm dia, ISI marked from wall to ground at any height upto 5 metrefixed with bends, tees, elbows, sockets, saddles, etc for condensed water including Taking out old unserviceable PVC drain complete all as specified and as directed. |
| 238 | Dismantling of Window /split type air conditioner of capacity complete set 1.5/2.0 TR and fixing the same toNew altered location, complete indoor and outdoor units, refrigerant tubing, MS stand, stabilizer and cable etc and testing completeall as specified and as directed. |
| 239 | Taking out window type air conditioner for servicing and overhauling of capacity 1.5/2.0 TRof any make/typeafter disconnecting of electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower and also including carrying out servicing, overhauling and charging of refrigerantgas and testing including fixing back in its original location complete all as specified and directed.Note:- (i) Spares will be measured and paid separately as supply only items (ii) Refrigerant gas will be measured and paid separately |
| 240 | M&L for leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in Window AC upto 2TR capacity and testing complete all as specified and as directed. Note:- Refrigerant gas will be paid separately under respective item. |
| 241 | S&F compressor of window type of air conditioner 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed.Make: LG/Voltas/Hitachi/LG/Blue Star. |
| 242 | S&F compressor of window type of air conditioner 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed.Make: LG/Voltas/Hitachi/LG/Blue Star. |
| 243 | Replacing the corroded outer casing with base tray sheet of the window type air conditioner of capacity upto 2 TR of any type/ make and supply and fix outer casing with base sheet made out of GI sheet suitable to window type air conditioner of capacity upto 2 TR complete all as specified and as directed. |
| 244 | Supply onlystarting capacitor 80 to 100, 100 to 120 MFD for window type air conditioner complete all as specified and as directed. |
| 245 | Supply only running capacitor 40/50/60 MFD for window type air conditioner complete all as specified and as directed. |
| 246 | Supply only relay contactor suitable for existing window type air conditionersupto 1.5/2 TR capacitycomplete all as specified and as directed. |
| 247 | Supply onlyfan motor with blade suitable for window type air conditionersupto 2 TR capacitycomplete all as specified and directed. |
| 248 | Supply only blower fan motor with blade including capacitor, single phase 230V, 50 Hz for window type air conditioner upto 2 TR capacity complete all as sepcified and as directed. |
| 249 | Taking out Refrigerator for servicing and overhauling from 165 litre to 352 litre capacity (single door/Double door type) of any make/type after disconnecting of electric connection and cleaning all the components, checking and replacing the spares like relay, capacitors, thermostat, Fused bulb and also including carrying out servicing, oiling, greasing, charging of refrigerantgas andtesting complete all as specified and directed.Note :- (i) Spares will be measured and paid separately as \"Supply only\" under relevant item. (ii) Refrigerant gas will be measured and paid separately as \"Supply only\".) |
| 250 | M&L for leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting ,soldering ,flaring work with nut ,jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in Refrigerator of size upto 352 litre cooling capacity and testing on completion complete all as specified and as directed. |
| 251 | Supply only relay assembly suitable for refrigerators of any type and capacity 165 to 352 litre complete all as specified and directed. |
| 252 | Supply only capacitor 6 to 10 mfd complete all as specified and as directed. |
| 253 | Supply onlythermostat switch for refrigerators of any capacity/ any make complete all as specified and as directed. |
| 254 | Supply onlyheating element 20 to 40 watt for refrigerators of any capacity/ any make complete all as specified and as directed. |
| 255 | S&F in repairs, condenser coil suitable for refrigerators of any type of capacity 165 to 352 litres complete all as specified and as directed. |
| 256 | S&F in repairs, cooling coil suitable for refrigerators of any type/capacity 165 to 352 litres complete all as specified and as directed. |
| 257 | S&F sealed compressor of Refrigerator upto 185 litres capacity including initial filling of refrigerant gas to the required pressure and testing including dismantling ofold unserviceable compressor complete all as specified and as directed. Make: Voltas/Kelvinator/LG/Blue star/samsung |
| 258 | S&F sealed compressor of Refrigerator 210 to 352 litres capacity including initial filling of refrigerant gas to the required pressure and testing including dismantling ofold unserviceable compressor complete all as specified and as directed. Make: Voltas/Kelvinator/LG/Blue star/samsung |
| 259 | S&F New capillary copper tube of dia 0.031\" (Inch) suitable for any type and capacity of refrigerator as per existing type/make/size including dismantling of old unserviceable tube complete all as specified and as directed. |
| 260 | S&F in repairs, anti bacterial door gasket set including magnet if required for refrigerator doors of any capacity / type/any make (As per sample) complete all as specified and as directed. |
| 261 | M&L for water, dust and direct heat proof cover of split AC outdoor unitof any description as per direction of Engineering In Charge. |
| 262 | Taking down voltage stabilizer, any make of capacity upto 5 KVA Single Phase by replacing unserviceable parts and refixing the same in working condition on existing location complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy