| 1 | Excavating over areas, n exc1.5 m deep and getting out soft/loose soil (Black cotton soil) complete all as specified and directed. |
| 2 | Excavating over areas,exc1.5 m deep and getting out soft/loose soil (Black cotton soil) complete all as specified and directed. |
| 3 | Removing excavated material exc. 1.5 Km but n exc. 5Km and depositing where directed. |
| 4 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 5 | M &L for Plain cement concrete in foundation filling type D-2 1:4:8 (40mm graded aggregate) and mass concrete complete all as specified and directed. |
| 6 | S&F for TMT bars 10mm dia and over, cut to length, bent to shape required including craking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed. |
| 7 | All as per item No 6 but 5mm dia and over up to and including 10mm dia in stirrups complete all as specified and directed. |
| 8 | M&L for RCC(Nominal Mix) Type B-1, 1;2:4 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; linth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 9 | M&L for RCC (Nominal Mix) Type B-1, 1:2:4 (20mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span and other similar bands, etc.complete all as specified and directed. |
| 10 | M&L for RCC (Nominal Mix)Type B-1, 1;2:4 (20mm graded aggregate) inColumns, pillars, piers, postsand struts complete all as specified and directed. |
| 11 | M & L Brickwork with fly ash bricks old sizestraight or curved on plan exc 6m mean radius built i inCM (1:6) all as specified. |
| 12 | M & L rough finishedFormwork to surfaces of concrete flat sides of concrete foundations, footing , bases of columns, raft and raft beams , sides and soffits if any of foundation and plinth beams and similar work complete all as specified and directed. |
| 13 | M & L rough finished Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed. |
| 14 | M & L rough finished surfaces of concrete form work square or rectangular to sides of pillars, posts, struts, columns and stanchions circular on plan complete all as specified and directed. |
| 15 | S & F rolled mild steel roof trusses (framed), trussed, purlins, rails and fastenings and heavy bracket framing, confirming to Fe 410-W (E-250) including distance pieces, cleats, etc., complete all as specified and directed. |
| 16 | S&F Pre -painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall,fixed with self tapping screwed as specified and directed by EIC. |
| 17 | S&F for Pre-painted galvalume aluminium zinc coating GI based plain/ridge steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 18 | M&L for 15 mm thick rendering in CM (1:4) on fair faces brick/concrete surface finished even & smooth without using extra cement complete mixed with WPC @ 3% by weight of cement all as specified and directed by EIC.Note : WPC shall be measured & paid separetely. |
| 19 | M&L for rendering 15mm thick on other thanfair faces of brick work or concrete surface in cement mortar 1:6 to be finished even smooth with out using extra cement as directed andspecified by engineer in charge. |
| 20 | M&L for applying two coat of distemper oil emulsion over 3mm thick wall care putty on wall, a coat of suitable primer on newly plastered surfaces on wall after necessary preparation of the surface, complete all as specified and directed. |
| 21 | M&L Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed. |
| 22 | M & L for preparation of new steel surface of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer completeall as specified and directed by Engineer in charge. |
| 23 | Supply only integral water proofing compound complete all as specified and directed. |
| 24 | M&L 100mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in sub base of floors complete all as specified. |
| 25 | M &L 25mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) in sub base complete all as specified. |
| 26 | Glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surfaces complete all as specified and directed. |
| 27 | M & L forNon - skid Colour Ceramic tiles 7 to 8 mm thick area of eachtile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchset and jointed over and including 15 mm thick screed bed in CM(1:4), inneat cement slurry andpointed in white or colourecement to match complete all as specified and directed. |
| 28 | M & L for Machine cutkota stone slab flooring 20-25mm thick over and including 15 mm thick screed bed in CM (1:4), cement screedbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completeand including complete all as specified and directed. cement to match |
| 29 | S & FPressed steel frames for doors of size 105x60 mmwith one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete, as specified, supplied and fixed complete all as specified and directed. |
| 30 | S & F 30mm thickFlush shutters, solid core construction,with particle board coreand plywood face panels, commercial type on both sidescomplete all as specified and directed. |
| 31 | S & F for anodised aluminium door shutter fixed with rubber gasket,stopper cleats, handles etc complete for aluminium frame of size 65mm x 38mm x 1.55mm and section of bottom and lock rail shutter frame of 45mm x 45mm x 1.55mm with and including panels of 5mm thick / frosted glass, and all necessary fittings complete all as specified and as directed by EIC. |
| 32 | S & F mild steel medium weight cold rolled butt hinge100mm size complete all as specified and directed. |
| 33 | S & F for Aluminium handles, cast type, anodised of 150mm sizecomplete all as approved complete all as specified and directed. |
| 34 | S & F Aluminium anodised, barrel tower bolts of extruded section and fixed(200mm long) complete all as approved complete all as specified and directed. |
| 35 | S&F for Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as approved complete all as specified and directed. |
| 36 | S&F in vitrious china wash basin, white flat back size 550X400mm including waste, chain & plug and poreclain stopper and bracket etc. Complete including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium plated for WHB etc. with long screwed shanks and fly nuts,flange end bedded in red lead cement including 32mm dia waste pipe fitted complete all as specified and directed. |
| 37 | S&F Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed fittedbore of trap 40mm complete all as spd and directed. |
| 38 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washerscomplete all as specified and directed. |
| 39 | S&F GI tubing medium grade with all fitting and fixed to wall ceiling or laid in floor etc complete of 20 mm bore pipe complete all as specified and directed. |
| 40 | All as per itemNo 39 but 15 mm bore complete all as specified and directed. |
| 41 | S&F15mm borestop/angle valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed by Engr-in-Charge. |
| 42 | S&F , 15mm bore, bib taps, fancy typechromium plated with crutch or butterfly handle, screwed down, screwed for iron pipeall as directed by EIC. |
| 43 | S&F 15 mm dia pillar tap fancy type with capstan heads chromium plated secrewed down, high pressure with or without lettered \"Hot or Cold with long sereuled shanks and fly nuts screwedfor iron pipe and fixed all as directed by EIC. |
| 44 | S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 45 | S&F 75/110 mm dia outlet PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 46 | M&L PVC(SWR) pipes 110mm dia single socketed, in any length with rubber ring joints,laid in trenches or fixed to wall complete all as specified and directed. |
| 47 | M&L PVC (SWR) bend any radius 110mm dia complete all as specified and directed. |
| 48 | M&L PVC(SWR) Tee any radius 110mm dia |
| 49 | S&F PVC(SWR) P trap of 110mm dia complete all as specified and directed. |
| 50 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as spd and directed. |
| 51 | S & F PVC connections suitable for 15 mm dia pipe with PTMT nut of lenth 450 mm complete all as specified and directed. |
| 52 | S&F 15mm diastop valvesfancy type,chromium plated complete all as specified and directed. |
| 53 | S &F shelf of PTMT Fixed with and including CP Brass screw and wooden/plastic cleaps complete all as specified and directed. |
| 54 | S & F CP tubular towel rail, 20 mm dia, D Type, 60 cm long between flanges complete all as speccified. |
| 55 | S&F Curtain rod, mild steel, chromium plated with fixing brackets,stops, rollers etc, complete all as specified. |
| 56 | M& L Providing and fixing Gypsum Board 12mm thick (size 600X600 mm) in ceiling perforated finish ,fixed with screw as per manufacturers instructionsfixed or laid over and including /Aluminium framework with screws all incld Anodised aluminium snap grid frame work for false ceiling incld suspended wire 3mm dia @1200mm c/cincldHangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm longand expansion hold fasteners 12.5mm dia. 40mm long complete all as specifiedall as specified as speicified and directed. |
| 57 | M & L powder coated anodised aluminium(sliding/hanging type) windows/ventilator with three track bottom track size 92 X 29.5 X 2mm thick, side & top track frame size92 X 29.5 X 2mm thickand shutter aluminium anodised 39 X 20 X 2 mm thick incl,with grill necessary aluminium fittings likejointing cleats, glazing cleats, rubber packing, anodised aluminium snap beading, screws etc with 5mm thick tinted/plain glass inpanels incl all fittings & fixture complete all as specified and directed. |
| 58 | M&L for preparing new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paintsover and incl a coat of pink primer all as specified and directd. |
| 59 | Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr depth for foundation etc or for column footings, manholes etc not exceeding 10 Sqm on plan and not exc 1.5 mtr in depthand getting out in soft/Loose Soil complete all as specified and directed. |
| 60 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out,all as specified and directed by Engr in Charge. |
| 61 | Removing excavated materialexc. 250 m but n exc. 500m and depositing where directed. |
| 62 | M &L for Plain cement concrete in foundation filling type B-2 1:2:4 (40mm graded aggregate) and mass concrete complete all as specified and directed. |
| 63 | S & F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, confirming to Fe 410 - W (Gde - E 250 - quality B)including distance pieces, cleats, etc., complete all as specified and directed. |
| 64 | S & F Plates (plain) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of FE 410-W (Gde-E-250) as directed byEngr in Charge. |
| 65 | S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 66 | S&F20mm borestop/angle valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed by Engr-in-Charge |
| 67 | M&L75mm thickPCC 1:3:6, type C-2 using 40 mm graded stone aggregate as in plinth protection complete all as specified and directed. |
| 68 | M&L for hardcore of gauge not exceeding 63mm,deposited, spred and levelled in layer not exceeding 15cm thick, watered and rammed to true surface complete all as specified and directed. |
| 69 | M & L forMachine pressed precast concrete interlocking paver block any shape and size with grey cement no pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 70 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 71 | M&L 150 mm dia (internal) Reinforced concrete pipes, class NP3, laid and jointed complete with collars all as specified and directed |
| 72 | M&L for concrete bed in PCC 1:3:6 type C2 (using 20 mm graded stone aggregate) to drain pipes includingpacking under,and haunchingagainst the sides of pipes, after they are laid andtested for 150 mm dia (internal) of NP3 pipes complete all as specified and directed (Pipes shall be measured & paid separately). |
| 73 | M&L for brick work with sub- class \"B\" , straight or curved on plan exc., 6m mean radius built in cement mortar 1:4complete all as specified and directed. |
| 74 | M&L point wiring with one light point or one fan point controlled by one switch with cables 1.5 sqmm HFFR copper multistranded conductor in Stove enamelled steel concealed conduit. |
| 75 | Supply and fix flame proof rotary type with termination box in LM6 16A single pole 250 volt complete all as directed.. |
| 76 | Supply and fixing Flame proof weather proof LED ceiling light fitting 45 watt 2 feet x 1 feet complete all as per Shyaam cat part No - SSPL/1233 or equivalent as approved. |
| 77 | Supply and fixing Flame proof weather proof Exhaust fan with louvers 300mm complete all as per Shyaam cat part No - SSPL/MT/140 or equivalent as approved. |
| 78 | Supply and fixing Flame proof weather proof Ceiling fan with regulator 1200mm single phasecomplete all as per Shyaam cat part No - SSPL/CF/193 & SSPL/2C/1010 or equivalent as approved. |
| 79 | Supply and fixing Flame proof weather proof distribution board SPN 4 way with incoming MCB 2 pole 16/25 amps - 01 Nos and outgoing MCB 1 pole 6/10 amp - 02 Nos complete all as per Shyaam cat part No - SSPL/CS/174 or equivalent as approved. |
| 80 | Supply and fixing Flame proof weather proof 3 way / 4 way junction box 100mm dia complete all as per Shyaam cat part No - SSPL/JB/105 or equivalent as approved. |
| 81 | Earthing complete with galvanisedearth plate electrode 60 cm x 60cmx 6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth lead wire 4.0 mm dia by means boltsand nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge.CI cover with frame etc including necessary excavation in any type of strata , returning, fillingremoval of soil outside MD land ,filling ofcharcoal andsalt complete all as shown in electrical plate No. 5 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. |
| 82 | Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPEinsulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size 6 Sqmm x 2 core |
| 83 | Supply and fixing gavonised iron pipe light grade including all fittings laid in trenches of size 40mm bore. |
| 84 | Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth and getting out in any type of soil for laying of cable, pipes etc. all as specified and directed. |
| 85 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 86 | Returning, filling inincluding spreading, levelling, watering and well ramming in layers not exceeding25 cm in soft/loose soil complete all as specified and directed. |
| 87 | M & L for providing dry river sand as in sand cusioning for underground cable protection including punning down sand in layers complete all as specified & directedNote: Only punned thickness of sand shall be considered for measurement purposes |
| 88 | Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 113 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed. |
| 89 | Cutting existing steel tubings for altrations or additions including screewing existiong pipe line and inserting Tee 40 x 25 x 40mm. |
| 90 | Supply and fixing gavonised iron pipe medium grade including all fittings laid in trenches of size 25mm bore. |
| 91 | Supply and fixing gun metal globe or gate valves with iron wheel head of size 25mm screwed both ends for iron pipe and fixed. |