| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 2 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and directed |
| 3 | Dismantling of wall andceiling boards(fibre, pulp, insulationetc.) or insulation boards/ slabs/ blankets, any thickness including cover filletscomplete all as specified. |
| 4 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. |
| 5 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) |
| 6 | Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each but with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engr-in-charge. |
| 7 | Dismantling timber scantlings 40 sq.cm and over in section, in any positions as in framed work. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 9 | M & L for Virified Ceramic tilesLight shed 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed . |
| 10 | M & L for Virified Ceramic tilesLight shed 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, on walls in dado/skirtting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed . |
| 11 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 12 | M & L for chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick, set, jointed and pointed in neat cement slurry over 20mm thick screed bed in cement mortar 1:4 as in floors with grey cement and pigment complete all as specified and directed. |
| 13 | S&F Pre-painting galvatume aluminum zinc coating GI based corrugatedsteel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed |
| 14 | S&F Pre-painting galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed |
| 15 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. |
| 16 | M&L for Precast cement concrete block masonry 1:3:6 type C1 with solid block exc 10cmin width and setting in cement morter 1:6 complete all as specified and ditected by Engr-in-Charge. |
| 17 | M & L for 12 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smoth without using extra cement complete all as specified and directed. |
| 18 | M&L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surface and finishing the surface even and smooth without using extra cement secified and directed by Engr-in-charge. |
| 19 | M & L for preparation of surfaces of new plaster surface of wall and applying two coats of oil emulsion distemper over a coat of chalk whiting , on plastered surfaces, preparatory to distempering complete all as specified and directed. |
| 20 | M & L for preparing newly plastered or previously untreated walls surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 21 | M&L for preparation of surfaces of old plaster surface of wall and applying two coat of cement base paint complete all as specified and directed. |
| 22 | S & F II class hard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamferred, put together with glue pinned at joints. complete all as specified and directed by Engr In Charge. |
| 23 | S & F 35 mm thick factory made second class hard wood, kiln seasoned and chemically pressure treated plain framed, panelled shutter (Two panel) with lock rail and panel of 9 mm BWP Commercial ply or 12 mm veneered particle board with commercial face veneers on both faces or 10 mm bison panel. |
| 24 | S & F II class hard wood Plain, framed, pannelled shutters 35 mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers etc completeas specified. |
| 25 | S&F butt hinges, medium weight, cold rolled mild steel, size 100mm. |
| 26 | S&F 150mm barrel tower bolts, stove enamelled black, with bright bolt.complete all as specified and directed by Engr In Charge. |
| 27 | S&F MS pressed handles, oval type, stove enamelled black size of 125mm. |
| 28 | M&L for galvanised M S Wire cloth of 0.56 mm nominal dia of wire and average width of aparture 1.18 mm fixed with tinned tack for galvanized wire staple complete all as specified & directed. |
| 29 | M&L for 5.5mm thick sheet glass in squares exceeding .50 Sqm in each pane with oil putty in complete all as specified & directed. |
| 30 | Material & labour for two coats of synthetic enamelled paint over a coat of pink primer on new wooden surfaces exc 10cm width or girth including preparation of surfaces.complete all as specified and directed by Engr In Charge. |
| 31 | Material & labour for two coats of synthetic enamelled paint over a coat of red oxide on new steel surfacesexc 10cm width or girth including preparation of surfaces.complete all as specified and directed by Engr In Charge. |
| 32 | M & L for removing of old paint by paint remover or burning off by blow lamps and cleaning with scrapers, any number of coats and any width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 33 | S & Frolled mild steel in Joist, channel, angle, or tee sections, fixed independently,without connecting plates, etc. (cut to ordinary lengths i.e. Within 20mm of the length indicated)conforming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified. |
| 34 | S & F bands, straps, supports or stays for rain water, ventilating pipes, including bolts if required as in wind tie using MS flat iron (40x6)mm and similar work confirming to Fe 290 (Gde-E-165) complete all as specified. |
| 35 | M & L 6 mm thick Ply wood, grade BWR, type BB fixed with screws to timber frame work inceiling etc complete all as specified and as directed. |
| 36 | S & F Second class hard wood plain fillets, wrought, square, rectangular or triangular in section, secured with screws, cross sectional area exceeding 3 and not exceeding 6 Sq. cm |
| 37 | Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches ,ceiling rose, pendent holder, sketch fitting & regulator etc. includingmaking good to the disturbed surfaces of wall, roofand floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 38 | Taking down unserviceable submain wiring and service cablealongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site. |
| 39 | Taking down unserviceable main switches, DBs with MCB SP/Isolators by unscrewing form board complete all as specified and directed by Engineer-in-Charge |
| 40 | M&L for point wiring using approved colour coding as per IS with using approved coper coding as per IS 1.5 Sqmm multistranded,1100 volt grade copper conductor cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulatedstranded copper conductor cable for continuous earthing in & incl PVC casing capingwith accessories having ISI mark fixed on wall surfaces / ceilingincluding provision PCV Box on top for fixing switches sockets etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 41 | Point wiring complete with 1.5 sqmm single core PVC insulated with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi standed copper conductor drawn through and including non metallic rigid PVC conduit with all conduit accessories (concealed)/ Casing and caping and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS box concealed in walls with 3 mm thick bakelite sheet ISI marked top cover with brass screws and cup washers for housing the switches, socket outlets, fan regulators etc forOne light /Exhaust Fan point controlled by one switch, all as specified and as directed. |
| 42 | All as per Srl item No 40 here-in-before but controlled with one 3 pin socket outlet 15 Amp onthe independent board with other switches with cables 2.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 43 | All as per Srl item No 41 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board withcable 2.5sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 44 | All as per Srl item No 40 here-in-before but controlled with one 3 pin socket outlet 5 Amp onthe independent board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 45 | All as per Srl item No 41 here-in-before but controlled with one 3 pin socket outlet 5 Amp onthe independent board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 46 | All as per Srl item No 40 here-in-before but controlled with one 3 pin socket outlet 5 Amp onthe same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 47 | All as per Srl item No 41 here-in-before but controlled with one 3 pin socket outlet 5 Amp onthe same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 48 | Supply and fixing ofswitch piano flush type 16 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 49 | Supply and fixModular switch 1 way 16A, 1 module, multipurpose flush type, ISI markedcomplete all as specified and as directed. |
| 50 | Supply and fixSocket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI markedcomplete all as specified and as directed. |
| 51 | Supply and fixing of socket outlet 3 pin 16 Amp 2-in-one230 Volt flush typecomplete all as specified and directed by Engineer -in-Charge. |
| 52 | Supply and fixSocket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI markedcomplete all as specified and as directed. |
| 53 | Supply and fixing of socket outlet 3 pin 6 Amp 2-in-one230 Volt flush typecomplete all as specified and directed by Engineer -in-Charge. |
| 54 | Supply and fixModular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete. |
| 55 | Supply and fixing ofswitch piano type 6 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 56 | M&L Ceiling rose, 3 terminal with ISI markall as specified and directed by Engr-In-Charge. |
| 57 | Supply and fixing recessed mounting 20 W 3000K 2x2 panel luminaire with high performance LEDs suitable for mounting with Grid ceiling Round incl driver complete fitting , all as specified and directed by Engr-in-Charge. Make: Crompton / Havells / Wipro |
| 58 | Supply andfixing surface & wall mounted LED 20W tube light fitting batten 4 feet, mirrorlite slim type with extruded aluminium housing alongwith 20W LED lamp PC body with all accessories all as specified and directed by Engg-in-Charge. Make: CromptonCat No. LDSLRP20-CDL |
| 59 | Supply andfixing surface & wall mounted LED 10W tube light fitting batten, mirrorlite slim type with extruded aluminium housing alongwith 10W LED lamp PC body with all accessories all as specified and directed by Engg-in-Charge. Make: CromptonCat No. LDLL-05-CDL |
| 60 | Material and labour forlamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. Make : Anchor/leader/havells |
| 61 | Supply and fixing9 watts LED backup lamp of 4 hours backup, with auto switch on mechanism in case of power failure, works as regular 9w lamp in normal mode and a 4w lamp in backup mode all as specified and directed by Engg-in-Charge. Make: Havells |
| 62 | Supply & Fixing bulk head light with 10 W LED Lamp complete. Make Bajaj Cat No BIBWP 10W LED or equivalent of Wipro and CG/Philips |
| 63 | S&F in replacement PVC exhaust fan, Single Phase 250mm sweep, with louvre complete all as per specified and directed by Engineer-in-Charge. Make - Havells |
| 64 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 3 module ISI markedcomplete all as specified and as directed. |
| 65 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 6 module ISI markedcomplete all as specified and as directed. |
| 66 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 8 module ISI markedcomplete all as specified and as directed. |
| 67 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 3 moduleISI markedcomplete all as specified and as directed. |
| 68 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 6 moduleISI markedcomplete all as specified and as directed. |
| 69 | Supply and fixing ofsheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge |
| 70 | S&F SPN 40 Amp,10 KA complete all as specified and directed by Engineer-in-Charge |
| 71 | S&F MCB SP 6 Amp to 32 Amp, 10 KA complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply,fixing, Testingwater heater storage type with multifunctional safety valve, electric operated 230 V, Single Phase complete including one no of heating element, automatic, thermal cut out, fusible plug, anti vacum sys, built in presser release valve,thermostat, rust proof powder coated body, indicator lamps and all safety advices as per E-in-C\"s Branch technical instructions and ofcapacity 25 liters including provn of grouting bolts in walls including piller cock , pvc connection ect and making good disturbed surfaces. Make : CG/Racold/Havells/Bajaj/indoand all as specified and directed by Engineer-in-charge . |
| 73 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 16 sqmm two core aluminium solid conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular |
| 74 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3connected to earthing testing pointall as specified or indicated including testing on completions. |
| 75 | Schedule of Credit |