| 1 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-charge |
| 2 | M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed . |
| 3 | Taking down cement plaster from brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed byEngineer-in-Charge. |
| 4 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces ion cement mortar 1:4 finishing the surface even and smooth ( without using extra cement) in two layers with WPC complete all as specified.(WPC measured separately). |
| 5 | M&L for rendering15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed byEngineer-in-Charge. |
| 6 | M&L for rendering5mmthick in cement plaster 1:3 on ceiling surface finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-charge |
| 7 | Supply only integral water proofing compound compete all as specified. |
| 8 | M&L for preparation of new plaster surface of ceiling and applying 1mm thick of wall putty, complete all as specified and directed. |
| 9 | M&L for preparation of newly plastered surfaces on wall/roof projections including facia, cornices etc and applying exterior water proof wall care putty @ 1Kg (undiluted) per sq mtr of average thickness 1mm or 2mm over the prepared plastered wall/ceiling surfaces, one or more coats and grinding the puttied surfaces with mechanical grinder for make the surface even and smooth for receiving primer and applying Two or more coats of 100% Premium acryli smooth exterior emulsion paint having VOC less than 50 gm/litre and UV resistane , Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives & Color stay technology, excellent dirt pickup resistance @ 1.67 litre/10 Sqm diluted with water as per manufacturers instructions over and including priming coat of exterior primer applied @ 0.9 litre (undiluted) /10 Sqm over new putyy surfaces of wall/ceiling complete all as specified and directed.Note : Paint using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed. |
| 10 | M&L for prepration of new plastered surfaces of ceiling and applying two coats of OBD complete all as specified and directed byEngineer-in-Charge. |
| 11 | Prepration of old surfaces of ceiling and applying one coats of OBD complete all as specified and directed byEngineer-in-Charge. |
| 12 | M&L for applying one coat of wall putty of minimum 2 mm thickover & above wall surface complete treated surface complete all as specified and directed. |
| 13 | M&L for preparation to new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed . |
| 14 | M & L for preparation of old/new surfaces of wall and applying minimum 1mm thick wall care putty over prepared surface and rubbing it with mechanical sander (having mechanical vaccum mechanism) to achive the surface even and smooth for further application of finishes with a coat of primer complete all as specified and directed. |
| 15 | M&L for applying two coats of oil bound distemper on treated old/new wall surface over complete all as specified and directed. |
| 16 | M&L for applying one coats of oil bound distemper on treated old treated wall surface over complete all as specified and directed. |
| 17 | M&L for Complete removal of existing treatment on external wall/roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour with mechanial sander having RPM of 1500 - 2700 rpm, with internal dust extraction system for clean enviornment and preparation of old plastered/srapped surfaces of wall/ceiling by filling cracks by external wall putty/crack fill paste and applying exterior water proof wall care putty @ 1Kg (undiluted) er sq mtr of average thickness 1mm or 2mm over the prepared plastered wall/ceiling surfaces, one or more coats and grinding the puttied surfaces with mechanical grinder for make the surface even and smooth for receiving primer and applying Two or more coats of 100% Premium acryli smooth exterior emulsion paint having VOC less than 50 gm/litre and UV resistane Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives & Color stay technology, excellent dirt pickup resistance @ 1.79 litre/10 Sqm diluted with water as per manufacturers instructions over and including priming coat of exterior primer applied @ 0.9 litre (undiluted) /10 Sqm over old/new putyy surfaces of wall/ceiling complete all as specified and directed.Note : Paint using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed. |
| 18 | M & L for applying Two or more coats of Acrylic Interior Emulsion paint, of approved manufacturer, of required shade and colour over a coat primer complete, as per manufacturer\"s specification complete all as specified and directed.Note- 1. Application of Primer and distemper to be carried out through Roller (Mechanical means)Makes: Nerolac-Little Master(Beauty), Berger-Bison Lite, Asian- Tractor emulsion spark.Note- 1. Application of Primer and distemper to be carried out through Roller (Mechanical means)2. Wall care putty (if required at site before application of above painting in certain portion ) shall be done and same shall be measured and paid seperately under serial item No 02 |
| 19 | Preparation of old decorated surfaces of wall and applying one coat of Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)complete all as specified and directed |
| 20 | Preparation of old decorated surfaces of wall and applying Two coats of cement base paint complete all as specified complete all as specified and directed byEngineer-in-Charge. |
| 21 | M&L for preperation of old painted wooden ceiling surfaces/joinery, wall and applyingone coat of synthetic enamel paint complete all as specified and directed byEngineer-in-Charge. |
| 22 | M&L for complete removal of existing wooden surface and preperation of old treatedwooden ceiling surfaces/joinery, wall and applyingtwo coat of synthetic enamel paint complete all as specified and directed byEngineer-in-Charge. |
| 23 | M&L for preperation of old painted steel surfaces and applyingone coat of synthetic enamel paint over 10 cm in width or girth complete all as specified and directed byEngineer-in-Charge. |
| 24 | M&L for complete removal of existing steel surface and preperation of old treated steel surface any type of surface like ceiling, wall, roof, projectioned surfaces and joinery applyingtwo coat of synthetic enamel paint complete all as specified and directed byEngineer-in-Charge. |
| 25 | French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood fillerone or more coats on old work complete all as specified and directed byEngineer-in-Charge. |
| 26 | Notes :- Amount of Credit Schedule for Schedule \"A\" Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum |