| 1 | Dismantling interlocking tiles includingh servicable tile to store and rubbish off the premises complete all as specified and directed. |
| 2 | Demolition of cement concrete in ground floors and paving n exc. 1.5cm thickness (Below or Above ground level). complete all as specified and directed. |
| 3 | Excavating over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed. |
| 4 | M & L for PCC 1:4:8 Type D-2 ( using 40mm Graded stone agg) as in foundations, filling and mass concrete complete all as specified and directed. |
| 5 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished surface of concrete complete all as specified and directed. |
| 6 | M&L for Reinforced cement concrete (Design Mix M-25) (using 20 mm graded sdtone agg ) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 7 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 8 | Description all as per ser item No 7 above but 5mm dia and over upto and including 10mm dia in stirrups,spacers and binders cutto lengthbent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed. |
| 10 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 11 | M&L for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W(Gde-E-250)quality-B complete all as specified and directed. |
| 12 | M&L for mild steel rag or lewis bolts 20mm dia , screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised,exc 15cm and n exc 30cm long complete all as specified and directed. |
| 13 | M & L for two coat of synthetic enamel painting over a coat of red oxide zinc chrome primer on new steel surface over 10cm width or girth incl preparation of surface complete all as specified and directed. |
| 14 | M & L for 75mm PCC 1:4:8 Type D-2 ( using 40mm Graded stone agg) as in sub base floor finished even and roughcomplete all as specified and directed. |
| 15 | M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern approved by GE conforming to IS 15658-2006as in footparth, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sandcomplete all as specified and directed. |
| 16 | M&L for providing, fabricating, assembling and erection of prestressed Tensile Membrane Fabric in desired profile as per conceptual drawing, with Serge Ferrari PRECONTRAINTTX-30 TypeIII or MEHLERVALMEX*MEHATOP*NFR 1000-Type III or SATTLER PRO-TEX Polyplan Architecture Type-III Art.659 or equivalent, having minimum Tensile strength (Warp/Weft) 5600/5400N/50 mm & minimum tear strength (Warp/Weft) of 700 / 650 N, high concentrated PVDF top coating and PVDF coated on bottom side, polyester fabric and should be weldable having a minimum weight of 1050 gm/sqm with a minimum 10 years warranty etc. of approved colour, over steel structure frames (underneath steel structure shall be paid separately) with all fittings and fixtures. Complete asper Drawing/Detail & as perparticular/ technicalspecifications and asper the directionsof Engineer- in charge. NOTE: Rate includes cost of fabric including IGST/GST/Import Duty/Custom Duty, transportation to site, designing, patterning, forming, cutting, fabrication, hot weld stitch of fabric, assembling and installation with GI strands, flashing, hardware, EPDM gasket, studs and other required accessories and fittings complete including lifts up to all heights, tools & plants, and necessary scaffolding etc. required for all operations in all. Nothing extra shall be paid on account of the above-mentioned elements over the quoted rates. Actual surface area of the fabric shall be measured for payment purpose/Colour of fabric will be Beige or White. |
| 17 | S&F MS heavy frame structure as per approved drawing complete in all aspects with duco paint (as per approved sample). Structural Steel Work Providing, Fabricating, Assembling, painting, hoisting, erecting and placing in position MS Built-up section/Tubular Structure Rolled section & plates confirming to IS 2062 minimum required grade E250, Tubular Structure:- made from Steel hollow sections, TATA/SAIL/RINLPaint/Primer of approved make with one or two coat of DECO Primer and paint as per standard. MS Section details are as follows :-(i) MS Vertical Pole Pipe169 OD with 5mm thickness(ii) MS Running Pipe114 OD with 4 mm Thickness(iii) Ms Purlin Pipe 89 OD with 3mm Thickness(iv) MS Base Plate 350 x350 x12 mm thickness(v) MS support Pipe Apollo 89 OD with 3mm Thickness(vi) Accessories Aluminum Strip, Nut bolts wire Plates with SS Wire fitting |
| 18 | Note For item No 16 & 17: (i) All Architectural drg/ structural drawings shall be submitted by the contractor for approval of accepting officer before commencement of work. Contractor shall not be allowed to commence the work without approval subject drawing and material approved for the same. (ii)Nothing shall be paid extra to the cotractor for preparing Architectural drg/ structural drawing including approval from Accepting Officer.(iii)The complete structure to be painted with one coat epoxy primer, two coat of epoxy paint and one coat of Deco spray paint on steel work at all locations prepared(iv) Accessories Aluminum Strip, Nut bolts wire Plates with SS Wire fitting(v) Lifts up to all heights, tools & plants, and necessary scaffolding etc. required for all operations in all, Complete asper Drawing/Detail & as perparticular/ technicalspecifications and asper the directionsof Engineer- in charge.Nothing extra shall be paid on account of the above-mentioned elements over the quoted rates |
| 19 | Material & Labour for point wiring for one light controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for flush type switch with cover plate, cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green) |
| 20 | Supply and fixing switchpiano,flushtype single pole, one way 5 Amps 3 pin, ISI marked for the same board complete all as specified and directed. |
| 21 | Supply and fixing ceiling rose, 3 phase/PVC/polycarbonate, isolated body type complete all as specified and directed. |
| 22 | Supply and fixing of tube light fitting 1x 20 watts 4 feet with LED batten with aluminium housing and integrated electronic driver in cluding LED tube light white colour complete including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 23 | Supply and layingof XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 10 Sqmm2 core with aluminium conductor laid in trenches/pipes, fixed topoles/walls with suitable saddle complete all as specified and directed. |
| 24 | S & F DB with sheet metal enclosure 240 volts, 4 way with 200 Amp rated bus bar single pole & neutral dsingle door type for MCBs including mounting work as required in positioncomplete all as specified and directed. |
| 25 | Supply and fixing rating 240V, 10KA \"B\"curve miniature circuit breaker (MCB) SPN and current carrying capacity 323 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 26 | Supply and fixing rating 240V, 10KA \"B\"curve miniature circuit breaker (MCB) SP and current carrying capacity 5-32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |