| 1 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 X 2.5 sq. mm (DSR 2025 - Item no.1.17.12) |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.4 X 4 sq. mm + 2 X 4 sq. mm earth wire (DSR 2025 - Item no.1.14.8) |
| 3 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (DSR 2025 - Item no.1.14.3) |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C (DSR 2025 -Item no.1.10.3) |
| 5 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door(DSR 2025 Item no.2.4.1) |
| 6 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door(DSR 2025 Item no.2.3.1) |
| 7 | 12 way, Double door(DSR 2025 Item no.2.3.3) |
| 8 | Supplying and fixing following rating, triple pole, 415 volts,\"C\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DBomplete with connections, testing and commissioning etc. as required. 63A |
| 9 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,\"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBomplete with connections, testing and commissioning etc. as required.Single pole (DSR 2025 Item no.2.10.1) |
| 10 | Single pole and neutral(DSR 2025 Item no.2.10.2) |
| 11 | Triple pole and neutral (DSR 2025 Item no.2.10.5) |
| 12 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (DSR 2025 Item no.2.11) |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch(DSR 2025 -Item no.1.24.1) |
| 14 | 3 pin 5/6 A socket outlet(DSR 2025 -Item no.1.24.4) |
| 15 | 15/16 A switch (DSR 2025 -Item no.1.24.3) |
| 16 | 6 pin 15/16 A socket outlet(DSR 2025 -Item no.1.24.5) |
| 17 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm)(DSR 2022 -Item no.1.27.6) |
| 18 | 3 Module (100mmX75mm)(DSR 2022 -Item no.1.27.2) |
| 19 | Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. 4 x 25 sq.mm |
| 20 | 4 x 16 sq.mm |
| 21 | 4 x 10 sq.mm |
| 22 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) (DSR 2025 - Item no. 11.1.34) |
| 23 | 4 X 16 sq. mm (28mm) (DSR 2025 - Item no. 11.1.33) |
| 24 | 4 X 10 sq. mm (25mm) (DSR 2025 - Item no. 11.1.32) |
| 25 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. upto 35 Sq.mm(Clamped with 1 mm thick saddle)(DSR 2025 item no.10.7.1) |
| 26 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. upto 35 Sq.mm(DSR 2025 item no.10.3.1) |
| 27 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia(DSR 2025 item no.15.13.3) |
| 28 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.(DSR 2025 item no.13.37) |
| 29 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm(DSR 2025 item no.10.5.1) |
| 30 | Supplying and fixing hot press molded SMC Box of size 300 x 200 x 105mm with suitable clamps to the wall/pole/truss/GI Pipe with connector bar etc. as required. |
| 31 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (DSR 2025 -Item no.2.18) |
| 32 | Supplying, installation, Testing and commissioningof40 watt LED LED Well Glass fitting of Environmental friendly, energy saving long life corrosion resistant, vertical/horizontal surface mounting pressure die-cast aluminium well glass luminaires with high power LED as light source and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required |
| 33 | Supplying, installation, Testing and commissioningof70 watt LED LED Well Glass fitting of Environmental friendly, energy saving long life corrosion resistant, vertical/horizontal surface mounting pressure die-cast aluminium well glass luminaires with high power LED as light source and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required |
| 34 | Supplying, installation, testing andcommissioning of Industrial Box type Luminaire batten suitable for single T8 LED Tube on wall/truss for fixing LED tube and using department supplied LED tubes including connection, testing as required. |
| 35 | Supplying,installation,Testing&CommissioningofStreetlightLEDfixture powdercoatedpressurediecastaluminiumbody withdriver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5KVL,N,EasperIEC61000-4-5, Driverefficiency >85%,THD< 10%asperIEC 61000-3-2,P. F.≥0.95,IP-66,IK-10,CRI>70, undervoltageandovervoltageprotection,EMI EMCAsper CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry)ofminimum 50000BurningHourswith 70%ofinitial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K/6500°K(Asper ANSIBin),SDCM (Standard Deviation Colour Matching) <5,Maximumpowerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standardcomplete inallrespecti/cexternal connectionswith1.5sq.mm FRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120lm/Watt output LM79 & LM80 Test report andalltestingrequiredforLED fixtures as per BISshall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkof aluminiumhousing such that LED junction temperature shall not rise above 90°C).72Watt (DSR 2025 -Item no.8.12.13) |
| 36 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%,suitable for operation withregulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019fani/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor singlecorecableandearthingetc.asrequired.1200mm,service value≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) (DSR 2022 Item no.9.2.3) |
| 37 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (DSR 2025 Item no.5.4) |
| 38 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (DSR 2025 -Item no.5.15) |
| 39 | Providing and fixing of Concrete baseMounted Feeder Pillar of size 135 x 120 x 30 cm with 2 mm CRCA Sheet with doors, Bus Bar Size 40 x 4 mm Alumunium, Earth Bar25 x 4 mm Copper, Door Earthing 2.5 mm Flexible Copper, Painting Powder Coating with provision for one incoming 125 A 4 pole 36 kA MCCB extended rotary handle, ELR with CBCT, three outgoing 63 A 4 pole 36 kA MCCB and one outgoing 63A 4 pole isloator extended rotary handle inclusive toggle switch, indicator lights, protection MCBs, multi function meter etc., complete as required. |
| 40 | Credit value of followingdimantled obselete/unserviceable materials.Dismantled scrap wire of Al.conductor cable. |
| 41 | Dismantled Panel Boards, MS conduits, DBs etc., at the site of the work as required |
| 42 | Dismantled Street lights/Flood lights |
| 43 | Dismantled tubelight fittings |