| 1 | SH: HOSTEL BUILDING (Earth Work) |
| 2 | Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | a) Ordinary Soil |
| 4 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 5 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 6 | SH: CEMENT CONCRETE |
| 7 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) excluding the cost of centring an shuttering in: |
| 8 | a) Foundations and plinth |
| 9 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring an shuttering in: |
| 10 | a) Foundations and plinth |
| 11 | SH: RCC WORK |
| 12 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : |
| 13 | a) 1 :1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 14 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. |
| 15 | a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 16 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 17 | a)1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 18 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 19 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with 1 : 1.5 : 3 (1 cement :1.5 coarse sand :3 stone aggregate 20 mm nominal size). |
| 20 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement:1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 21 | Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 22 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 23 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 24 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 25 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 26 | f) Stairs (excluding landings) except spiral stair cases. |
| 27 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 28 | b) Tar/TMT steel |
| 29 | SH: BRICK WORK |
| 30 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 31 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 32 | SH: STONE WORK |
| 33 | Random rubble masonry with hard stone in foundations and plinth in cement mortar 1 : 6 (1 cement : 6 fine sand) including levelling up with cement concrete 1 : 6 : 12 (1 cement : 6 coarse sand : 12 stone shingle 20 mm nominal size) at plinth level. |
| 34 | Masonry with pre-cast cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) blocks in cement mortar 1 : 4 (1 cement : 4 fine sand) in foundations and plinth. |
| 35 | Extra for pre-cast cement concrete block masonry in superstructure above plinth level up to floor two level. |
| 36 | SH : WOOD WORK |
| 37 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 38 | Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc. |
| 39 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental Grill |
| 40 | Aluminium work |
| 41 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other section of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing /panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : |
| 42 | 1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade SC 15) |
| 43 | SH: FLOORING |
| 44 | Cement concrete flooring 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. |
| 45 | (a). 40 mm thick |
| 46 | 40 mm thick red oxide flooring, under layer of 30 mm thick cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size ) & top layer of 10 mm thick plaster of cement red oxide mix ( using 3.5 kg of red oxide of iron per 50 kg of cement) 1 :3( 1 cement red oxide mix : 3 coarse sand ) finished with a floating coat of neat cement red oxide mix of same proportion. |
| 47 | Add per 1 kg for using more or less than 3.5 kg of red oxide of iron per 50 kg of cement in 40 mm thick red oxide flooring. |
| 48 | Red oxide plaster skirting (upto 30 cm height) with top layer of 6 mm thick plaster of cement red oxide mix ( using 3.5 kgs of red oxide of iron per 50 kg of cement ) in mortar 1 : 3 ( 1 cement : 3 coarse sand) finished with floating coat of cement red oxide mix of same proportion. |
| 49 | (a). 18 mm thick |
| 50 | Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: |
| 51 | a) Light shades using white cement |
| 52 | SH ROOFING |
| 53 | Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand). |
| 54 | b) 100 mm diameter pipe |
| 55 | Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10 cm x 10 cm x 10 cm of 1 : 2 : 4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. |
| 56 | b) 100 mm diameter |
| 57 | SH : FINISHING |
| 58 | 12 mm cement plaster 1 : 4 (1 cement : 3 fine sand). |
| 59 | 15 mm cement plaster 1 : 6(1 cement : 6fine sand) on the rough side of single or half brick wall. |
| 60 | 20 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 61 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 62 | Painting two coats with oil type wood preservative of approved brand and manufacture on new work. |
| 63 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 64 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade |
| 65 | Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work. |
| 66 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade |
| 67 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 68 | MISCELLANIOUS |
| 69 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 70 | Providing and fixing 40 mm dia GI Pipe outlet in cement mortar 1 : 3 (1 cement : 3 fine sand) including cutting and making good the wall. |
| 71 | SH: Drain |
| 72 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 73 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.a) 100 mm dia SW pipes |
| 74 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design. |
| 75 | a) 100 mm dia SW pipes |
| 76 | SH: WATER SUPPLY |
| 77 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). |
| 78 | a) 15 mm nominal bore |
| 79 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). |
| 80 | c) 25 mm nominal bore |
| 81 | Providing and fixing brass bib cock of approved quality. |
| 82 | a)15 mm nominal bore |
| 83 | Providing and fixing brass stop cock of approved quality. |
| 84 | a) 15 mm nominal bore |
| 85 | Providing and fixing PVC connection pipe with brass union. |
| 86 | 1) 45 cm length |
| 87 | a) 15 mm nominal bore |
| 88 | Providing and fixing Sintex water tank. |
| 89 | SH : SANITARY |
| 90 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. |
| 91 | b) Orissa Pattern WC Pan |
| 92 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. |
| 93 | a) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality. |
| 94 | Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm |
| 95 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 96 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). a) 750 x 20 mm size |
| 97 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 98 | a) 100 mm dia |
| 99 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 100 | a) 100 x 100 x 100 mm |
| 101 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. |
| 102 | a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 103 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
| 104 | SH : SEPTIC TANK |
| 105 | Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 106 | a) Ordinary Soil |
| 107 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 108 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : |
| 109 | a) Foundations and plinth |
| 110 | b) Walls including attached buttresses, pilasters and their caps andbases and string courses etc. up to floor two level. |
| 111 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : |
| 112 | a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 113 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 114 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 115 | b) Tar/TMT steel |
| 116 | Centring and shuttering including strutting proping etc. and removal of form work for: |
| 117 | b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 118 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 119 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 120 | a) 100 mm dia SW pipes |
| 121 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design. |
| 122 | a) 100 mm dia SW pipes |
| 123 | SH : Electrification (Point Wiring) |
| 124 | Point wiring in PVC conduit, with modular type switch. |
| 125 | Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm.FR PVC insulated copper conductor single core cable etc. as required. |
| 126 | Group C |
| 127 | Circuit/sub-main wiring in PVC conduit :- |
| 128 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. |
| 129 | 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug). |
| 130 | 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire (for ckt wiring). |
| 131 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire(for power point). |
| 132 | S/F PVC conduit :- |
| 133 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 134 | 25 mm |
| 135 | 32 mm |
| 136 | S/F modular type switch/socket :- |
| 137 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 138 | 5/6 Amps Switch |
| 139 | 15/16 Amps Switch |
| 140 | 5/6 Amps Socket |
| 141 | 15/16 Amps socket outlet |
| 142 | S/F modular boxes, Base & Cover Plate:- |
| 143 | Supplying and fixing following size/module GI box along with modular base and cover plate for modular switch in recess extr as required. |
| 144 | 1 or 2 module (75 mm x 75 mm) |
| 145 | S/F modular type electronic fan regulator :- |
| 146 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 147 | S/F modular type blanking plate :- |
| 148 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate etc. as required. |
| 149 | S/F light plug point modular type accessories :- |
| 150 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,connection,painting etc. as required.(For light plugs to be used in non residential buildings). |
| 151 | S/F power plug point modular type accessories:- |
| 152 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 153 | ITC fluorescent fitting directly on surface :- |
| 154 | Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types,complete with all accessories and tube etc. directly on ceiling/wall,including connection with 1.5 sq. mm FR PVC insualted,copper conductor,single core cable and earthing etc. as required. |
| 155 | ITC ceiling fan :- |
| 156 | Installation, testing and commissioning of ceiling fan including the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insualted,copper conductor,single core cable and earthing etc. as required. |
| 157 | Upto 450 mm sweep |
| 158 | S/F call bell/buzzer :- |
| 159 | Supplying and fixing call bell/buzzer suitable for D.C/A.C single phase , 230 volts, complete as required. |
| 160 | S/F steel conduit :- |
| 161 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 162 | 20 mm |
| 163 | 25 mm |
| 164 | Wiring in existing conduit :- |
| 165 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 166 | 2 x 1.5 sq. mm |
| 167 | 2 x 2.5 sq. mm |
| 168 | MCB DISTRIBUTION BOARDS |
| 169 | S/F prewired SP MCB DB : |
| 170 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 171 | 8 way (4 + 24), Double door |
| 172 | S/F prewired TP MCB DB : |
| 173 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 174 | 12 way (4 + 36), Double door |
| 175 | S/F \"C\" series,SP MCB |
| 176 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 177 | Single Pole |
| 178 | Single Pole and Neutral |
| 179 | S/F TP MCB isolator :- |
| 180 | Supplying and fixing following rating, Four pole,415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required . |
| 181 | 63 Amps |
| 182 | S/F SPN RCCB :- |
| 183 | Supplying and fixing following rating, double pole,(single phase and neutral), 240 volts, residual current circuit breaker (RCCB),having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 184 | 63Amps |
| 185 | S/F 20A SPN MCB Industrial Socket outlet :- |
| 186 | Supplying & Fixing 20 A 240V SPN Industrial Type Socket Outlet with 2 Pole earth metal enclosed plug top along with 20 A \"C Series\" SP MCB in sheet metal enclosure on surface or in recess with chained metal cover for the socket outlet & complete with connections, testing & commissioning as required. |
| 187 | SH: CABLE WORK (MV cable laying upto 400 sqmm. in pipe) |
| 188 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 189 | Above 120 sq. mm and upto 400 sq. Mm |
| 190 | MV cable laying upto 400 sqmm. On surface |
| 191 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/HUME/ METAL pipe as required. |
| 192 | Above 120 sq. mm and upto 400 sq. mm |
| 193 | 11 KV CABLE JOINTING WITH CAST RESIN COMPOUND |
| 194 | Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : |
| 195 | 300 sq. mm |
| 196 | 11 KV CABLE JOINTING WITH CAST RESIN COMPOUND |
| 197 | Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : |
| 198 | 300 sq. mm |
| 199 | F/I cable trays |
| 200 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts& nuts, painting suspenders etc as required. |
| 201 | 100 mm width x 50 mm depth x 1.6 mm thickness |
| 202 | EARTHING (G.I Plate Electrode) |
| 203 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 204 | Copper Plate Electrode :- |
| 205 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 206 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 207 | Providing and fixing 25 mm x 5 mm Cu. strip on surface or in recess for connection etc. as required. |
| 208 | S/L 8 SWG Copper wire in ground |
| 209 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |