| 1 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exc 15cm thickness (below or above ground level), complete all as specified and as directed. |
| 2 | M&L for 25 mm thick PCC type B1 (1:2:4) using (20 mm graded aggregate) as in flooring, complete all as specified and as directed. |
| 3 | M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded aggregate as in plinth protection finished even and smooth w/o using extra cement, complete all as specified and as directed. |
| 4 | M&L for 75 mm thick PCC 1:4:8 type C-2 using 40 mm graded aggregate as in sub base, complete all as specified and as directed. |
| 5 | S&F in repair 2nd class softwood in scantling clean swan timber framed and fixed to the position including dismantling, complete all as specified and as directed. |
| 6 | Dismantling timber scantlings in fillets, rails,posts rafters,purlins etc under 40 sqcm in section unframed work, complete all as specified and as directed. |
| 7 | M&L for plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails exc 13 but n. exc 25 sqcm in section, complete all as specified and as directed. |
| 8 | Dismantling of wall and celling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness inlcuding cover fillets, complete all as specified and as directed. |
| 9 | M & L of 6mm thick veneered decorative plywood,grade 1 (with decorative face veneers on one faces) on wall, fixed with nails to timber frame work, complete all as specified and as directed. |
| 10 | M & L of 6mm thick veneered decorative plywood, grade 1 (with decorative face veneers on one faces) in ceiling, fixed with nails to timber frame work, complete all as specified and as directed. |
| 11 | M&L plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails not exc 3 sqcm in section, complete all as specified and as directed. |
| 12 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, complete all as specified and as directed. |
| 13 | S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugationsside lap, fixedwithcoach screws and washers, in roofs, wallsetc. with grade of zinc coating 275. incl dismantling, complete all as specified and as directed. |
| 14 | S&F 0.80mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings(length and girth as fixed) with grade of zinc coating 275incl dismantling, complete all as specified and as directed. |
| 15 | Taking down chowkats or frames but with shutters (without taking off shutters from the frame) exc 1.5 Sqm and n.exc 4.00 sqm, complete all as specified and as directed. |
| 16 | Taking down chowkats or frames but with shutters (without taking off shutters from the frame) not exc 1.5 Sqm, complete all as specified and as directed. |
| 17 | S&F 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed. |
| 18 | S&F 2nd class soft wood glazed and skeleton shutters 35 mm thick , open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and as directed. |
| 19 | S&F Glazed and skeleton shutters thickness 30 mm,(2nd class softwood), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Section specified 8 clause 8.24(b) , complete all as specified and as directed. |
| 20 | S&F Aluminium anodised, barrel tower bolts 100 mm of extruded section and fixed, complete all as specified and as directed. |
| 21 | S&F Aluminium anodised, barrel tower bolts 150 mm of extruded section and fixed, complete all as specified and as directed. |
| 22 | S&F Aluminium alloy, anodised, sliding door bolt 200 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed. |
| 23 | S&F M S Butt hinges 100 mm medium weight, cold rolled mild steel, complete all as specified and as directed. |
| 24 | S&F M S Butt hinges 75 mm medium weight, cold rolled mild steel, complete all as specified and as directed. |
| 25 | S&F Aluminium handles 100 mm , cast type,anodised, complete all as specified and as directed. |
| 26 | S&F Aluminium handles 150 mm , cast type,anodised , complete all as specified and as directed. |
| 27 | M&L two coats of synthetic enamel paint over and including a coat of pink primer including preparation of surface on new wooden sruface over 10 cm width or girth . Complete all as specified and directed. |
| 28 | M&L Preparation of old wooden surface of any description and applyingtwo coat of synthetic enamel paint over a coat of primer, not otherwise described,over 10cm width or girth, complete all as specified and as directed. |
| 29 | Demolition of brick work, PCC block masonary, stone masonary or boulder masonry built in cement mortar, complete all as specified and as directed. |
| 30 | Taking down cement plaster or screed bedding layer of any description from concrete slab/terrace surfaces etc including racking out joints hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 31 | M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:6), complete all as specified and as directed. |
| 32 | M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6), complete all as specified and as directed. |
| 33 | M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4), complete all as specified and as directed. |
| 34 | S&F 3mm thick Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane incl Hackingoutoldbrokenglass (anythickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed. |
| 35 | S&F 3mm thick Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane in wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed. |
| 36 | M&L Preparation of newor previously untreated surfaces of anydescription, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 37 | S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed. |
| 38 | S&F sheet glass shelf assembly consisting of 5.5 mm sheet glass shelf 12 cm wide with brass chromium plated bracket guard and 60 cm long, complete all as specified and as directed. |
| 39 | S&F corner sheet glass shelf assembly consisting of 5.5 mm sheet glass shelf 12 cm wide with brass chromium plated bracket guard, complete all as specified and as directed. |
| 40 | S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup, complete all as specified and as directed. |
| 41 | S&F vitreous china wash down water closet pan ( Pedestal pattern) white or coloured excluding flushing cistern and flush pipe and seat cover incl provision of concrete/ white cementing and P or S trap in repairs, complete all as specified and as directed. |
| 42 | S&F PVC flushing cistern, 10 ltrs capacity, low level including brackets, inlet and outlet PVC pipe and fittings complete fixed in repairs, complete all as specified and as directed. |
| 43 | S&F for 15 mmbore in repair bib taps, fancy type chormium plated with crutch or butterfly handle screwed down screwed for iron pope or for brass ferrule in repair, complete all as specified and as directed. |
| 44 | S&F in repair stop valves fancy tupe chromium plated screwed down high presure , with crutch or butterfly handle, cscrewed both ends for iron pipe or for unions 15 mm bore, complete all as specified and as directed. |
| 45 | S&F in repair PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, laid in trenches or in floor, complete all as specified and as directed. |
| 46 | S&F in PVC (SWR) junction single T equal or unequal 110 mm dia, complete all as specified and as directed. |
| 47 | S&FPVC (SWR) bends 110 mm dia fixed, complete all as specified and as directed. |
| 48 | S&F in repair PVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floor, complete all as specified and as directed. |
| 49 | S&F in PVC (SWR) junction single T equal or unequal 75 mm dia, complete all as specified and as directed. |
| 50 | S&FPVC (SWR) bends 75 mm dia fixed, complete all as specified and as directed. |
| 51 | S&F PVC connection pipe 15 mm size with PTMT nuts of length 600mmfixed to GI tubbing, complete all as specified and as directed. |
| 52 | Taking down and replacement with 3-layer PP-R polypropylele random copolymer) concealed pipe SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PRR plain & brass threaded polypropylele random fittings fixed complete to walls, ceiling or in floors, complete all as specified and as directed. |
| 53 | S&F in repair brass chromium plated tubular towel rail 20 mm dia D type , 60 mm long between flages, complete all as specified and as directed. |
| 54 | S&F Stop/angle valves 15 mm, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated, complete all as specified and as directed. |
| 55 | S & F Brass CP wall mixer15 mm for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and as directed. |
| 56 | Excavation in trenches for sewage line in any type of soil, n exc 1.5 M wide and n exc 1.5 M deep for foundation, etc or for shafts, wells, manholes etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil, complete all as specified and as directed. |
| 57 | Returning filling in incl spreading leveling, watering and well ramming in layers n exc 25 cm, complete all as specified and as directed. |
| 58 | Removing excavated materials n exc 50M and depositing where directed at a level n exc 1.5 M above the starting point, complete all as specified and as directed. |
| 59 | Demolition of cement concrete reinforcement cut as required to facilitate demolition) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 60 | M & L precastRCC manholes cover in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, complete all as specified and as directed. |
| 61 | M&L Mild steel TMT bars 8 mm dia, quality conforming to Grade 415 MPA cut to length , bent to shape required including cranking , bending and binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 62 | M&L in repair for 25 User LLDPE septic tank (conventional) designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc, complete all as specified and as directed. |
| 63 | Demolition and breaking up drain pipe75/100 mm dia (AC,saltglazed, PVC or RCC pipes ) set in CM or any description incl Excn of Earthwork , RFR, removal and making good, complete all as specified and as directed. |
| 64 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregates as in bed to drain pipes including packing under and haunching against the sides of pipes after these are laid tested for 150 mm bore of pipes, complete all as specified and as directed. |
| 65 | M&L for 150 mm internal diaSail-glazed stoneware drain pipes laid in trenches and jointed as specified, complete all as specified and as directed. |
| 66 | M & L for non skid coloured printed ceramic tile 8 to 10 mm thick ( Square/rectangular/in joint less) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm,in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15 mm thick screed bed in CM (1:4), complete all as specified and as directed. |
| 67 | Dismantling floor hearth wall tilling including cement mortar bedding, removing serviceable tiles to store and rubbish off the permises, complete all as specified and as directed. |
| 68 | M & L for glazed ceramic tiles in vertical surface 600x300x10 mm thick colour and design (as approved) in vertical surfaceand jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15 mm thick cement plaster using CM (1:4), complete all as specified and as directed. |
| 69 | S&F Plain, framed,panelled shutters thickness 35 mm of 2nd class softwood,(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and as directed. |
| 70 | S&F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube fixed in opening, complete all as specified and as directed. |
| 71 | S&F for 30 mm thick factory made solid panel PVC door shutter confirming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C\" channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of \"C\" channel using PVC solvent adhesive complete as per manufacturers specifications & drawings ass as directed by Engineer-inCharge. |
| 72 | Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 3.0 Meffective depth as per TD drawing of CE 31 Zone, complete all as specified and as directed. |
| 73 | S&F for Plain, galvanised, mild steel 0.63mm sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and as directed. |
| 74 | Dismantling timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and as directed. |
| 75 | M&L for Second class soft-wood in framed and fixed scantlings, complete all as specified and as directed. |
| 76 | M&L for Weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps, complete all as specified and as directed. |
| 77 | M&L for Walling of random rubble, uncoursed, built in cement morter 1:4, complete all as specified and as directed. |
| 78 | M&L for Walling of random rubble except stone, uncoursed, built in cement morter 1:4, complete all as specified and as directed. |
| 79 | M&L Keyed pointing to random or polygonal rubble, uncoursed or brought upto course in cement morter 1:4, complete all as specified and as directed. |
| 80 | M&L for cement concrete type B1 1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 81 | S&F for Plain, framed,panelled shutters (any number of panels) 40mm thickness, with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial faceveneers: suppliedand fitted to chowkats, complete all as specified and as directed. |
| 82 | S&F for Aluminium alloy, anodised, sliding door bolt 150mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed. |
| 83 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 84 | M&L for 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base, complete all as specified and as directed. |
| 85 | M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate)as in sub base, complete all as specified and as directed. |
| 86 | M&L for Screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) for laying floor finishes, complete all as specified and as directed. |
| 87 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed. |
| 88 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers notexceeding 25 cm, complete all as specified and as directed. |
| 89 | M&L for cement concrete 1:3:6 type C-2 using (40mm graded stone aggregate) as in foundations , filling and mass concrete, complete all as specified and as directed. |
| 90 | M&L Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tilesnot exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding 15mm thick screed in CM(1:4), complete all as specified and as directed. |
| 91 | M&L ofsoftwood 2nd class boarding, supplied & fixed with nails in any situation (except flooring and skirting), Planed one side and edgestongued and grooved or rebated on wall of 10-15mm, complete all as specified and as directed. |
| 92 | M&L ofsoftwood 2nd class boarding, supplied & fixed with nails in any situation (except flooring and skirting) Planed one side and edgestongued and grooved or rebated on ceiling 10-15mm complete all as specified and as directed. |
| 93 | Dismantling boarding, any description, fixed in any position with nails, Complete all as specified and directed. |
| 94 | S&F Softwood 2nd class Clean sawn with butt joints eaves boards 20 mm thick, Complete all as specified and as directed. |
| 95 | M&L Weather boarding, 25 mm thick, wrought both sides, V-jointed to give 20mm laps and fixed, Complete all as specified and directed. |
| 96 | M&L Creosote preparing surfaces of wood and wood based materials, and wood based materials, new or old, of any description and girth, not otherwise described and treated with, complete all as specified and as directed. |
| 97 | S&Fin repair curtain rod, mild steel, chromium platedfixing with stainless steelbrackets and funnels stops, rollers etc, complete all as specified and as directed. |
| 98 | S&F CP health faucet hand held triggered nozzle and delivers a spray of water with pipe, complete all as specified and as directed. |
| 99 | S&FCP jet spray with flexible tube 1.5 mtr long, complete all as specified and as directed. |
| 100 | M&L in repair for 10 User LLDPE septic tank (conventional) designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc, complete all as specified and as directed. |
| 101 | S&F in repair vitreous china wash basin, white flat back size 550x400 mm plug, porcelain stopper and incl brackets with waste fittings and connection pipe etc including pedestal, complete all as specified and as directed. |
| 102 | S&F Brass CP centre hole basin mixer, complete all as specified and as directed. |
| 103 | S&F in repair 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in positionon roofs etc,including tank nipples, fittings, including dismantling of existing water tank any type,disposal of rubbish, complete all as specified and as directed. |
| 104 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. |
| 105 | M&Lfor point wiring inPVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqmm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor. |
| 106 | (a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 107 | (b) One 3 pin 5 Amp switch socket outlet on independent board |
| 108 | (c) One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 109 | M&Lfor point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 2.5 Sqmm as earth continuity conductor. |
| 110 | S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed |
| 111 | S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed |
| 112 | S&FSocket outlet 2 in 1, 3 pin, 5 Amps, flush type complete with gang box, complete all as specified and as directed. |
| 113 | S&FSocket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete with gang box, complete all as specified and as directed. |
| 114 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 115 | S&F in repairs Distribution Board, SPN 8 Way, Double door, complete all as specified and as directed. |
| 116 | S & F in repairs MCB,DP 63 Amps 240 VoltsB curve, complete all as specified and as directed |
| 117 | S & F MCB Single pole 6-32A Amps 240 Volts B Curve, complete all as specified and directed |
| 118 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 119 | S& F LED light fitting 1x10 bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 120 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 121 | Supply and fixing LED bulb 12 W, 220V suitable size, complete all as specified and as directed. |
| 122 | S&F Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and as directed. |
| 123 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, complete all as specified and as directed. |
| 124 | S&F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet, complete all as specified and as directed. |
| 125 | Supply & fixing in repair capacitor 1.5/2 mfd suitable for 1200mm sweep ceiling fan, complete all as specified and as directed. |
| 126 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated Supply Supply and fix complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and as directed. |
| 127 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 16 sqmm, complete all as specified and as directed. |
| 128 | M & L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm diaPVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed.Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing capping shall be measured as one RM |
| 129 | Taking down and dismantling the ceiling fan from site and removing its allied smaller parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers complete including, flexible chord of 24 / 0.20mm with necessary connector (for blade / body) as required after rewinding complete all as specified and directed. Note : Spares used and rewinding shall be measured and paid seperatly under relevant item. |
| 130 | M&L in repairs for Earthing complete with galvanizedsteel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, RFR and removal etc. |
| 131 | Note:- Schedule of credit Rs 97,349.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. |