| 1 | M&L Air termination single pointed aluminium rod 12 mm dia and 300 mm long all as specified and as directed by Engr-in-charge. |
| 2 | M & L Test point terminal block made of gun metal or phosphorus bronze size incliding 3 Nos 8 mm dia 25 mm long hex. Head screw all as specified and directed by Engr-in-charge. |
| 3 | M & L aluminium strip 25 x3.15 mm with saddles amd fixing secres etc for roof conductors and down conductors all as specified and directed by Engr-in-charge |
| 4 | M & L Galvanised iron stip 32 x 6 mm burried in ground all as specified and directed by Engr-in-charge |
| 5 | S&F in repair of GI tubing 15 mm bore \"medium grade\" including all necessaory fittings i.e. socket, elbow etc.laid in trenches complete all as specified and directed. |
| 6 | S&F Stop valve of 15mm dia complete all as specified and directed. |
| 7 | Supply and fix Bib tap 15 mm bore size of cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed |
| 8 | M&L for Cutting the existing GI pipe upto 80mm for tapping of 15 mm branch including required fittings complete all as specified and as directed. |
| 9 | S&F epoxy insulators suitable of aluminium strip of 25x3.15 mm size with nut bolts/ screws for fixing of copper/ aluminium / GI strips on stone / PCC block walls etc complete all as specified and directed. |
| 10 | S&F in repair of earthing pit cover 50 mm thick precast slab of RCC 1:2:4 type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm incl 6 mm dia bar handle complete all as specified and directed. |
| 11 | M&L for fixing earth indicators made out of 3 mm thick MS sheet of size 200 mm x 300 mm duly fixed in MS angle iron 25 mm x 25mm x 3mm of 600 mm long fixed to ground by means and including necessary cement concrete foundation and painting with one coat of synthetic enamel paint over a coat of red oxide primer complete for writing earth reading and connected plant/ panel etc. and excavation and earth work complete all as specified and directed. |
| 12 | Material and labour for supply, installation, testing and commissioning of GI pipe electrode earthing maintenance freeearthing based on 6 mtr long GI pipe 76 mm dia(ID) medium grade, GI strip 32x6 mm (Strip in pipe type electrode) and GI pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the GI pipe electrode. Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed.Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore.Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.GI strip must be connected with GI pipe electrode and other jointsthrough GI nut bolt complete all as specified and directed. |
| 13 | M & L GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling or laid on floor all as specifed and directed. |
| 14 | M & L for providing cement concrete in roof of type B1 1:2:4 20 mm graded aggregate in roof kerbs or mug stops, rounded or chamfered on deges all specified |
| 15 | Supply and laying in trenches or fixing to wall/pole or passing through pipe XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 150 Sqmm 3.5 core.Make of cable ICL/ICC/Gloster/Havells/ Paragon/ Grandlay/Kalinga. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 16 | Supply and fixing 80 mm dia DWC (Double Wall Corrugated) pipe (6 mtr length) in trenches for laying of under ground cable, HSN Code : 3917 and product code A0214100NEC012D any approved make etc complete all as specified and as directed |
| 17 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft/loose soil etccomplete all as specified and directed by Engr-in-Charge. |
| 18 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soilcomplete all as specified and directed by Engr-in-Charge. |
| 19 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rockcomplete all as specified and directed by Engr-in-Charge. |
| 20 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soilcomplete all as specified and directed by Engr-in-Charge. |
| 21 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting pointcomplete all as specified and directed by Engr-in-Charge. |
| 22 | Supply and fix GI Pipe Light gradewith all connected accessoriesof sizes80 mm diacomplete all as specified and directed by Engr-in-Charge. |
| 23 | Cutting of existing road not exc 1.5 mtr in depth and not exceeding 1.5 mtr wide including black top, sub base and WBM, well ramming in layers with watering afterlaying of RCC /GI pipe under road making good in all respectto match with the existing surface all as directed by E-in-charge. |
| 24 | Supply install, test and commissioning of Powder coated LTpanel cubical out door type free standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars of 300 A, incomer MCCB and outgoing feeder.The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhavefree standing bottom frame/stand of height 600mm & dimension as required for panel & shall be made out of equal angle iron of size 50mm x 50mm x 6mm. A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 100 Amps & above. The panel shall be powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including taking down of old unsv panel after disconnecting Existing cable & Reconnecting the cables to new panels including providing cable glands, lugs, nut bolts etc, grouting bolts, the panel shall comprise of following and including demolition of existing PCC foundation, complete all as specified & directed by Engineer in Charge. |
| 25 | a) Aluminium bus bar 450 Amps for 3 phase and 225 Amps for Neutralb) MCCB FP 250 Amps 415 Volt36 KA - 1 Nosc) MCCB FP 160 Amps 415 Volt25 KA - 2 Nosd) MCCB FP 125 Amps 415 Volt25 KA - 2 Nose) MCB SPN 40 Amps, 10 KA 415 Volts- 1 Nosf) Fully automitic On load change over switch 4 Pole 250 Amps - 01No g)RYB Indicators - 1 Set h) Street Light Timer Circuit with Following Acessories:-(i) ML 3, Contactor Coil Voltage 440 Volts - 1 No(ii) Astro Timer - 1 No(iii) Auto Manual Selector Switch - 1 No(iv) Cnnector TPN 63 Amps - 4 Nos(v) MCB TPN 63 Amps - 1 NoNote - Note :-(i) The lay out drawing of the panel shall be got approved by the contractor before panel fabrication.(ii) PCC Foundation required for installation of Panel Shall be Measured and Paid Seperately under respective item. |
| 26 | Excavation in post holes or (Similar holes) each n.exc 0.5 cum, getting out, returning filling in and ramming each or broken rubber mixed with each around in layers, n.exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making food surfaces in Hard/Dense soil. |
| 27 | M&L for PCC 1:3:6 type C2 (40 mm graded Stone aggregate) as in foundation of post holes filling and mass con crete all as specified and directed. |
| 28 | S&F for steel work in tublar traes including special shaped washer etc complete using ERW or induction but welded tubes conforming to IS 1161-1979 grade SI-240 |
| 29 | S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 30 | S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 31 | M&L for two coat of synthetic enemel paint on new steel surfaces over one coat of red oxide primer over 10 cm width of grith including prepration of surface |
| 32 | Supply and install Tower AC indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better air quality with minimum 3 star rating and EER 3.2 of capacity 3.0 TR complete with fixing moviting brackets/stand for fixing, refrigerent pipping, cable and drain water piping of any length as per site requirement etc as directed by Engr-in-Charge. |
| 33 | M&L for Sheet metel enclosure with Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps, 415 volts all as specified and directed by Engr-in-Charge. |
| 34 | M&L for sub main wiring complete with two runs of single core 4sq mmFRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4 sqmm single Flame retardan PVC insulated unshedthed multi stranded copper conducator green colour cable for continuous earthing complete in & including PVC casing & caping with all fitting & fixtures all as directed and specified ( Note Two runs of 4 sqmm copper cable and one run of 4 sqmcopper cable including PVC casing & caping shall be measured and paid as one length). |
| 35 | Supply and fixing LED flood light 70 watt 230 VAC outdoor type with thermal management in pressure die cost aluminium housing with lense, high wattage LEDand equipped with IP66 protection, with impact and corrosion resistant complete with driver complete incl provide of 3 core 1.5 sqmm wire from ceiling rose to light fitting all as specified and directed . |
| 36 | Supply and fixing LED luminaire 600 mm x 600 mm, 40watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver,holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 37 | M & L for brick work with sub class `B` bricks using old size bricks straight on plan built in cement mortar 1:6 etc all as specified and directed. |
| 38 | M & L forPCC 1:2:4 type B2 inusing 40 mm graded stone aggregate even thick finished even and smooth all as specified and directed |
| 39 | M & L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc all as specified and directed. |
| 40 | M & L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc all as specified and directed. |
| 41 | M & L for 15 mm thick rendering in CM 1:6 on fair faces of brick work / concrete work and finished even& smooth without using extra cement all as specified and directed. |
| 42 | Supply & Fixing XLPE(Heavy duty) electric cables with Aluminium conductor 1100 Volts grade cross sectional area of size 25 sq mm 4 Core all as specified and directed. |
| 43 | M&L dry river sand in trenches for cable cushioning & protection including spreading, ramming all as specified and directed. |
| 44 | Supplying and laying un-reinforced precast concrete cable cover, LV low voltage type -I flat size 250 mm x 150 mm x 40 mm complete all as specified and directed. |
| 45 | S&F rotational moulded polyethylene water storage tank of 5000 ltrs (Cylinderical vertical with closed top) hoisted and float valve fixed in position andcomplete all as specified and directed by Engr-in-Charge. |
| 46 | Supply and lay in galvanized tubes, medium grade(B class ) of dia 25 mm with all fittings such as bends, teen, elbows complete all as specified and directed by Engr-in-Charge. |
| 47 | M&L Hand rails, grills ,Gates ,half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof ,Brackets for Valley gutters ,including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 |
| 48 | M&L for Cutting holes in brick/stone walls in mud/cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4Type B-1 as required all as specified and directed by Engineer-in-Charge. |
| 49 | M&L for preperation of new concrete /plastered surface of any description, two coat of destemper oil emulsion over a coat of primer complete all as specified and as directed complete all as specified and as directed. |