| 1 | Dismantling asbestos cement (corrugated or semi corrugated) sheets in roof covering complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Dismantling structural steel in any positon incl doors,gates, framed truss etc, complete all as specified and as directed by Engineer-in-Charge. |
| 3 | M&L Fe 410 -W(Gde-E- 250) quality-A,steel Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam,tee,angle,guirders, channelor flat sections) including distance pieces, cleats etc, rectangular section. complete all as specified and as directed by Engineer-in-Charge. |
| 4 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering fixed with self tapping screwscomplete all as specified & asdirected by Engineer-in-Charge. |
| 5 | M &L for 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed withwasher in roof, wall etc. fixed with L-type or J-type or cranked hook bolts in lieu of screwcomplete all as specified and as directed by Engineer-in-Charge |
| 6 | M&L for0.8mm thick pre paintedPlain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275complete all as specified and as directed by Engineer-in-Charge |
| 7 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles and removing the debris outside the defence land complete all as specified and as directed by Engineer-in-Charge. |
| 8 | M & L Brick work with fly ash old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 in any position,complete all as specified and as directed by Engineer-in-Charge. . |
| 9 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) and removing the same out side MD land complete all as specified and as directed by Engineer-in-Charge. |
| 10 | M&L for 75 mm thick Cement concrete M-10 grade (Nominal Mix)using 40mm graded stone aggregate as in sub floors, sub bases,floors and paving etc. complete all as specified and as directed by Engineer-in-Charge. |
| 11 | M&L 25 mm thick Cement concrete M-15 grade (Nominal Mix) using12.5 mm graded aggregate) as in sub base floor complete all as specified and as directed by Engineer-in-Charge |
| 12 | M&L Machine pressed precast concrete interlocking paver block with grey cmen and pigmentsany shape and size confirming to IS 15658-2006 of 80 mm thickness M-50 Gradeset over & including 25mm sand cushion complete all as specified and as directed by Engineer-in-Charge. |
| 13 | M&L for granolithic topping floor 30 mm thick with M-20 grade (Design Mix) over and incl 75 mm thick PCC M-15 grade (Nominal Mix)using 20mm graded stone aggregate laid on floors finishing cement concrete surface even and smooth using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 14 | M & L 38 mm wide 1.5 mm thick Plastic dividing strips placed in position complete all as specified and as directed by Engineer-in-Charge. |
| 15 | M & L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4etc complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Taking down cement plaster in any description includingracking out joints hacking for key and scrubbing down with water etc & removing the same out side MD land complete all as specifiedand directed |
| 17 | M & L for hacking for key, raking out joints of old brick work or stone work built in lime or mud mortar; not previously plastered; and scrubbing down with water etc. to receive plaster and removing thesame out side MD land complete all as specified and as directed by Engineer-in-Charge. |
| 18 | M & L Keyed pointing to random rubble or polygonal rubble uncoursed or brought up to courses in wall in CM 1:4,complete all as specified and as directed by Engineer-in-Charge. |
| 19 | M & L for rendering/plastering, 15 mm thick in cement mortar 1:6 on stone masonry surfaces or concrete surface up to 9 m height complete all as specified and as directed by Engineer-in-Charge. and as directed by Engineer-in-Charge. |
| 20 | M & L for preparation of new plastered or unplastered surface of wall and applying two coat of oil bond emulsion,incl primer white or tinted complete all as specified and as directed by Engineer-in-Charge. |
| 21 | M & L for complete removal of existing treatment on wall surfaces of any description including brooming down with steel wire brushing , scrapping down smoke soot\"s, moulds , moss and efflorescence, salts, trading oil greasy spots etc and applying two coats of Anti fungal weather proof grade exterior Acrylic emulsion paint of approved tint over a coat of weather proof primer including filling the cracks etc with crack filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 Sqm/Ltr as per manufacturer instructions and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 Ltr per minute having a pressure of 3300 PSI, allow 6-8 hrs to dry the surface in subsequent coats of paint upto height 10 mtr including necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&L Preparation of newly previously untreated surface of steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primercomplete all as specified and as directed by Engineer-in-Charge. |
| 23 | M & L for Preparation of old steel surfaces of any description, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. |
| 24 | Taking down chowkats and frame n.exc 1.5 Sqm including shutter with out taking off shuttersfrom frame all as specified and directed by Engr-in-Charge. |
| 25 | S & F Steel windows/ventilator with side hung shutters including projecting type hinges with steel handle, and steel peg stay,complete with glazing bars, dovetailed or welded |
| 26 | S & F stainless steel wind driven turbo ventilators of approved make 600 mm effective throtal dia, 800mm outer dia, overall height of 490 mm fixed over corrugrated / prepainted galvalume sheet of any type all as specified and as directed |
| 27 | Taking down damaged steel doors area upto 20 Sqm carrying out repairs incl material and labours for replacement of damage steel part except MS Sheet ( sheet will be mesured and paid seperately) and refixing the door in same position incl necessary reasing/oiling for proper functioning and any other requiremnet for proper working of door comp complete all as specified and as directed by Engineer-in-Charge. and as directed by Engineer-in-Charge. |
| 28 | S & F1.25 mmthickMild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. |
| 29 | M & L for75mm thick Plinth protection in PCC M-10 grade (Nominal Mix) using 40 mm graded stone aggregatecomplete all as specified and as directed by Engineer-in-Charge. |
| 30 | M&L for Hardcore of gauge n exc. 63 mm,with broken stone and boulder, deposited, spread and levelled in layers n exc. 100mm thick, watered and rammed to a true surfaces for plinth proection complete all as specified and as directed by Engineer-in-Charge. |
| 31 | M & L for chipping, removing carefully lose concrete work by low impact hammer/breaker without damaging the structure and claning and disposal of malba outside the premises etc and also cleaning the existing reinforced and casting and repairing the existing structure by using polymer modified mortar thickness upto 40mm including levelling profile etc each layer should not have more than 20mm with epoxy latex bond coat before each layer including formwork at any height height complete all as specified and as directed by Engineer-in-Charge. and directed |
| 32 | Taking down carefully existing unserviceable aluminium / copper point wiring of any description & in any position with and including existing steel conduit / PVC Conduit / Casing capping fixed on surface/wall/angle/gardder and including all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, sockets, etc including sunken boxes/junction boxes and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and as directed by Engineer-in-Charge. and directed. |
| 33 | Material and labour for point wiring for in and including stove enamelled steel conduit with and including all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arrangements made out from 20x1mm flat aluminium patti including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mmon surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 1.5 sqmm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wireincl. suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size with 3 mm thick laminated hylum sheet for mounting switches, sockets etc.and making good the disturbed wall and painting the same with matching colour of the existing wall, include material all as specified and directed. |
| 34 | one light/ fan/ bell point controlled by one switch |
| 35 | One 5 pin socket outlet, 5 Amps on same board controlled with other switches. |
| 36 | One 5 pin socket outlet, 5 Amps on independent board. |
| 37 | All a s per Srl item No 33 above but point wiring for one five pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor . |
| 38 | Supplying & fixing switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete all as specified and as directed by Engineer-in-Charge. |
| 39 | Supplying & fixing socket outlet, five pin, 5 Amps, flush type, multipurpose, 230 volts AC circuit complete all as specified and as directed by Engineer-in-Charge. & directed |
| 40 | Supplying & fixing switch flush type, 15 Amps, single pole, one way , 230 volts AC circuit complete all as specified and as directed by Engineer-in-Charge. & directed |
| 41 | Supplying & fixingSocket outlet 2 in 1, 3 pin, 5 and 15 amp flush type , flush type, 230 volts AC circuit complete all as specified and as directed by Engineer-in-Charge. & directed |
| 42 | Supplying & fixing ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified and as directed by Engineer-in-Charge. |
| 43 | Supply and fixing Stepped type electronic fan regulator flush typesuitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified and as directed by Engineer-in-Charge. |
| 44 | Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 ratingelectric driven single phase including MCB \"C\" series SP 20 Amps and supplied with neutral links including taking dowin old Earth plug & socket with sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge. and directed. |
| 45 | Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven three phase including MCB \"C\" series TP 20 Amps and supplied with neutral links including taking dowin old Earth plug & socket with sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge. and directed. |
| 46 | Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing cappingincluding making good to the disturbed wall and painting the same with matching paint asexisting wallcomplete all as specified and directed by Engineer in charge. |
| 47 | Material and labour Sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sqmm 1100 volt grade anddrawn through 20mmsteel conduit including 1.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) in green colour for continuous earthing all as specified and directed. Note :- Two runs of 1.5 Sqmm cable and one run of 1.5 sqmm earth continuity cable withone run of steel conduit minimum dia 20mmshall be measured as one unit length |
| 48 | Material & Labour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade drawn through and including 20mm steel conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm, ISI marked, FRLSH type in green colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed.Note :- Two runs of 2.5 Sqmm cable and one run of 2.5 sqmm earth continuity cable withone run of steel conduit minimum dia 20mmshall be measured as one unit length |
| 49 | Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, ISI marked, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including 20mm steel conduitincluding connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, ISI marked, FRLSH type, 4.0 sqmm, 1100 Volts grade, ISI marked, as earth contuinity wire all as specified and directed by Engineer in charge.Note:-. Two runs of4.0 Sqmm cable and one run of earth continuity wirewith one run of steel conduit minimum dia 20mm shall be measured as one unitlength |
| 50 | Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, ISI marked, FRLSH type, 6.0 Sqmm, 1100 volts grade, drawn through and including 20mm steel conduitincluding connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, ISI marked, FRLSH type, 6.0 sqmm, 1100 Volts grade, ISI marked, as earth contuinity wirecomplete all as specified and asdirected by Engr-in-Charge. Note:- Two runs of6 Sqmm cable and one run of 6 Sqmm cableearth continuity wire shall be measured as one length with one run of steel conduit minimum dia 20mm complete all as specified and asdirected by Engr-in-Charge. |
| 51 | M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, at any height, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for mounting Air Circulator / Exhaust Fan / Ceiling Fan/highbay fittings etcfor fixing arrangements complete all as specified and as directed by Engineer-in-Charge. |
| 52 | Dismantling and Taking down unserviceable any light fitting from any location/height after disconnecting of electrical connection complete including all connected accessories all as directed by Engr-in-Charge. |
| 53 | Supply & fixing, CRCA housing box LED Type luminiare suitable for and including 2x20 W 4 feet long complete including tube rod & connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. |
| 54 | Supply and fixing at 5 to 9 mtr height-120W Industrial LED Highbay luminaire with > 100 Lm/W,with complete all accessorieshaving IP 66 degree of protection, power factor >0.95,THD<10%, potted driver, Internal Surge Protection-4KV & External Surge Protection-10KV,LED Source including safety chain with i boltcomplete all as specified and as directed by Engineer-in-Charge.Note :- The quoted rates shall bedeemed toinclud the cost of Nut-bolts washars or clamps etc . |
| 55 | S&F connecting & testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties including taking down old SPN DBs of 12 wayall as specified & directed |
| 56 | S&F, connecting & testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire tiesincluding taking down old SPN DBs of 8 wayall as specified & directed |
| 57 | S&F, connecting & testing of VTPN DB of 4 way suitable for MCCBup to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, complete all as specified and as directed by Engineer-in-Charge.Make Legrand or equivalent in Schneider- Acti-9/ L&T-Exora.Note : MCCB , MCBwill be measured and paid separately under relevant item of this schedule. |
| 58 | Supplying & fixingMCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly,complete all as specified and as directed by Engineer-in-Charge. |
| 59 | Supplying & fixing MCB 6 to 32 Amps, single pole and neutral, \"C\" curve10 kA breaking capacity with integrated label holder,sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed by Engineer-in-Charge. and directed. |
| 60 | Supplying & fixing MCB 40 to 63Amps, TPN\"C\" curve10 kA breaking capacity with integrated label holder,sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed by Engineer-in-Charge. |
| 61 | S&F, Thermal magnetic adjustable MCCB 100 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete all as specified and as directed by Engineer-in-Charge. |
| 62 | S&F, Thermal magnetic adjustable MCCB 63 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete all as specified and as directed by Engineer-in-Charge. |
| 63 | M&L for earthing complete withGI Steel pipe in pie electrodeincluding Short circuit testing , 3mtr long and having copper bonding of suitable thickness and copper bondedterminalto connect earthing strip with suitable depth holes for nut bolts, buried directly and vertically in ground with top edgebelow ground level after making bore hole of requireddia and suitable depth using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing leadstrip with minimum two Nos of GI nut bolts and connected to test pointfrom earthing pit. Area between pipe and copper rod filled with Dry type chemical powder.The electrode pipes should be filled with 2x 25 kg bags of carbide based BFC earthing compound . The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between 7-9. Connected to the earthing test point, Special high grade polymer compound Round earth pitwith pit cover,including necessary returning filling& removal of extra soil , to achieved earth resistance valueless than 1 Omsincluding testing complete all as specified and as directed by Engineer-in-Charge.NOTE: In casethe desired result is not obtained after testing the contractor should do re-eathing without any extra cost. |
| 64 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core includingtaking down old XLPE cable all as specified and directed by Engr-in-Charge. |
| 65 | Supply & fix LED Street light 120W including making electrical connection to the fitting with Suitable size of service wire including GI bracketall as specifie and directed |