| 1 | Taking down exiting copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed |
| 2 | M&L for concealed point wiring complete with and including single core PVC FRLSHinsulated unsheathed flexiblebright annealed multi stranded copper conductorcables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site,totally concealed inwalls/floors/ceilingincluding all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked andmodular sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in wallswith modularsheet top cover, fixed flush with wall surface by means of brass screws and sunk/cupwashers, for mounting of switches, sockets fan regulatos etc; including 1.5 Sqmm (22/0.30 mm)1100 V gradeFRLSH,PVC insulated, unsheathed flexiblemulti stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed and shown on drgs,forone light point or one fan point controlled by one switch |
| 3 | Ditto all as per item No 2 above but one 3 pin socket outlet, 5/6 Amps on the same board with other switches |
| 4 | Ditto all as per item No 2 above but one 3 pin socket outlet, 5/6 Amps, on independent board |
| 5 | M & L forconcealed point wiring complete with and including single core PVC FRLSHinsulated unsheathed flexiblebright annealed multi stranded copper conductorcables 4.0 Sqmm 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site,totally concealed inwalls/floors/ceilingincluding all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked andmodular sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in wallswith modularsheet top cover, fixed flush with wall surface by means of brass screws and sunk/cupwashers, for mounting of switches, sockets fan regulatos etc; including 4.0 Sqmm 1100 V gradeFRLSH,PVC insulated, unsheathed flexiblemulti stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed and shown on drgs,foronesocket power point controlled byby one 15 Asingle poleswitch |
| 6 | One bell/ buzzer point controlled by one push button on independent board with cables 1.5 sq.mm size |
| 7 | S&F in replacement of modular switch 1 way 10 A 1 module all as specified and directed . Make: HavellsRoma/Vinay/Crabtree |
| 8 | S&F in replacement of Modular socket 6 A 2/3 Pin2 module all as specified and directedMake: HavellsRoma/Vinay/Crabtree |
| 9 | S&F in replacement of modular switch 1 way 16 A 1 with indicator module all as specified and directed . Make: HavellsRoma/Vinay/Crabtree |
| 10 | S&F in replacement of Modular socket 6 A/16A 2/3 Pin2 module all as specified and directed . Make: HavellsRoma/Vinay/Crabtree |
| 11 | S&F modular BLDC fan regulator, 2 module, suitable for ceiling fan of 1200/1400mm sweep all as specified and directed . Make: HavellsRoma/Vinay/Crabtree cat part no ACWRFXW006 |
| 12 | S&Fin replacement of ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body. Make:Vinay/Anchor Roma |
| 13 | M&L in replacement of bell push flush type 5Amps single pole (Make:Anchor/Cona) |
| 14 | S&F electric bell Ding Dong type AC, 230 volts single phase complete all as specified. |
| 15 | S & Ff RJ-11 telephone socket with transparent shutter 2 module alongwith flush metal box 2 module and front cover plate 2 module all as directed. |
| 16 | S &F for LAN RJ-45 Jack With Cat 6 socket UTP Catwith transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module all as directed. |
| 17 | S &F for TV socket with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module all as directed. |
| 18 | S&F in replacement modular USB Charger all as specified and directed.Make: HavellsRoma/Vinay/Crabtree |
| 19 | Provn ofPVC conduit for Telephone/ TV/ LAN/ CCTV/PAnot less than 25 mm with Cutting chases for concealed for Telephone/TV/LAN/CCTV/PA wire, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface all as specified and directed.Note: 1. Rate quoted shall deemed to include cost oftaking down existing Telephone/TV/LAN/CCTV/PA wire. .2Rate quoted shall deemed to include cost ofrelaying existing Telephone/TV/LAN/CCTV/PA wire through PVC conduit. |
| 20 | S&F in replacement of 20watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose complete all as specified.Make- Havells/ Wipro /crompton/ |
| 21 | S&F in replacement ofPanel LED round type LED ceiling lights 10 W LED, 6000K Environmental friendly, energy saving, recess mounted downlighter with electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully complete all as specified and directed. Make: HAVELLS-/Philips/luker |
| 22 | S&F in replacement of Bed lamp 7 W LED, 6000K Environmental friendly, energy saving, recess mounted downlighter with electronic driver including connecting with twin core wire complete all as specified and directed. Make: Luker cat part no. LWLCR-3/HAVELLS-/Philips/luker |
| 23 | S&F in Decorative wall lights 9 Wwith WW LED Bulb E 27 with Base with polycarbonate diffuser complete all as specified and directed. Make: Luker cat part no. LWL205-1S or equivalent in Halonix/Havells/ Wipro / Halonix/Benlo |
| 24 | S&F in Hanging LED Downlight lights 12 Wwith WW LED Bulb E 27 with Base with polycarbonate diffuser complete all as specified and directed. Make: Luker cat part no. LHL402E or equivalent in Halonix/Havells/ Wipro / Halonix/Benlo |
| 25 | S&Fin replacement LED building security Sensor light fiitting 30 W, IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover havingseperate driver compartment complete fixing with GI bracket made out of suitable GI pipe light grade suitable length bend to shape and fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed.Make- Luker LSTE030S/ Havells / Wipro /Halonix |
| 26 | Taking down ceiling fan/Exhaust Fan, sealing cable end,dismantling blades and removing fan and blades to store as directed. |
| 27 | M&L for cutting chases for concealed conduit wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface complete all as specified and directed. |
| 28 | Taking down exiting copper/aluminium sub main wiring complete for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed. |
| 29 | M&L forconcealed sub main wiring with two single core PVC insulated FRLSHcables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including PVC conduit medium grade with all fitting & other accessories and copper cable 2.5 sqmm continuous earth wirecomplete all as specified and directed . (Two runs of 2.5 Sqmm cable with 01run of 2.5 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM) |
| 30 | M&L forconcealed sub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including PVC conduit medium grade with all fitting & other accessories and copper cable 4 sqmm continuous earth wirecomplete all as specified and directed. (Two runs of 04 Sqmm cable with 01run of 4 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM) |
| 31 | M&L forconcealed sub main wiring with Two single core PVC insulated FRLSHcables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including PVC conduit medium grade with all fitting & other accessories and copper cable 6 sqmm continuous earth wirecomplete all as specified and directed. (Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along withPVC conduit medium grade shall be measured as one RM) |
| 32 | S&F in MCB DB 12 way SPN Double door sheet metal enclosure factory made suitable for MCB DB\"s 240 volts,concealed in wall complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site complete all as specified and directed by Engr-in-charge.Make: Havells/Legrand.Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. |
| 33 | S&F in replacement of MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed. |
| 34 | S&F in replacement of of C Curve MCB SPN 40 to 63 Amps working on 240 volts, 50 HZ,10 KAcompl;ete all as specified and directed |
| 35 | S&F MCB DB 04 way SPN Double door sheet metal enclosure factory made suitable for MCB DB\"s 240 voltswith 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and existing circuits complete as reqd at site |
| 36 | S&F MCB TPN 63 Amps 415V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing. |
| 37 | S&F in replacement sheet metal enclosures single pole MCB 20 Amps with a two pin and earth plug and socket complete with all accessaries etc all as specified and directed. Make: Legrand Cat part: 5078 10 or equivalent in C&S/L&T |
| 38 | Taking down existing geyser of 25 ltrs capacity of any make/brand,dismantling Hot and Cold pipe and deposite to EM store as directed |
| 39 | Supply and Installation of Electric Chimneys 90cm Min Noise Levels in 41dB,Max Suction 1587 m3/hr,9 speed,Intelligent Autoclean Gesture Control,Silent Inverter Motor / Smart On, Warranty on Appliance 2 Year,Warranty on Motors 10 Years and Professionally install the electric chimneys, including mounting, electrical connections, and testing.Securely mount the chimney on the wall or ceiling, ensuring it is level and stable.Install ductwork to vent the exhaust outside, ensuring minimal noise and maximum efficiency.Test the chimney to ensure it operates correctly and efficiently. Provide a demonstration to the user on how to operate and maintain the chimney andClean the installation area, removing any debris or packaging materials.all as specified and directed. Make - Crompton QuietPro Plus CHD-QPPB90FLE-MBL |
| 40 | S&F in replacement electrical meter box compartmentalized design suitable for 1 x energy meter and 1 x four way SPN DB, 3 x 2 way SPN DB outdoor wall mounted type, weather proof fabricated out of not less than 2.0 mm thick CRCA sheet, powder coated in siemens grey colour, double door. The enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakelite sheet for mounting the energy meters and MCB DB. The enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables/wires. The overall size of the meter box should be as per site requirement complete with all accessories prewired twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.(Note: The quoted rate shall deemed toincluding for disconnecting existing circuits from DB\"s and energy meter and same to be refixed in new meter box) |
| 41 | M&L in repair for earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in elecrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion all as specified and directed.Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire above 7.5m will be measured and paid seperately. |
| 42 | Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in elecrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion all as specified and directed.Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire above 7.5m will be measured and paid seperately. |