| Sl. No. | Item Description |
| 1 | Dismantling of Plain corrugated Steel Sheeting, any gauge, thickness, including Nainital or similar type roof covering, complete in all respect as specified and directed. |
| 2 | Dismantling of floor/ wall tiles including cement mortar bedding of any thickness upto PCC/ RCC/brick surface and rubbish off the premises, complete in all respect all as specified and directed. |
| 3 | Dismantalling of cement concrete (unreinforced) in ground floors and pavings not exceedings 15 cm thickness (below or above ground level), complete in all respect as specified and directed. |
| 4 | Dismantalling of reinforced cement concrete of any description and in anypositionnot otherwise specifically provided for complete in all respect as specified and directed. |
| 5 | Taking down shutterexc 1 sqm and n. exc 2 sqm each, complete in all respect as specified and directed. |
| 6 | Taking down chowkats and shutters (without taking off shutters from the frame) n.exc 1.5 sqm each, complete in all respect as specified and directed. |
| 7 | Taking down shutter and refixing in same opening after easying exc 1 sqm and n. exc 2 sqm each, complete in all respect as specified and directed. |
| 8 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm and n.exc 4 sqm each, complete in all respect as specified and directed. |
| 9 | Taking down cement plaster of any thickness and description on brick/ concrete/ stone wall/ ceilings, etc, including raking out joints, hacking for key, scrubbingdown with water etc, complete in all respect as specified and directed. |
| 10 | Demolition and breaking up drain pipes 75 mm/110 mm bore dia (Salt glazed ware, PVC or Reinforced concrete) set in cement mortar, complete in all respect as specified and directed. |
| 11 | M&L for brick work with sub-class \"B\" old size bricks of class designation (CD) 75, straight or curved on plan exc 6m mean radius, built in cement mortar (CM) 1:6, including dismantalling of brick work built in cement mortar in any position, complete in all respect as specified and directed. |
| 12 | M&L for half brick work with subclass ‘B’ old size bricks of class designation 75, straight or curved on plan exc. 6m mean radius built in CM (1:4) including dismantalling of brick work built in cement mortar in any position, complete in all respect as specified and directed. |
| 13 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using FE-410W (Grade E-250 quality \"A\") complete all as specified and directed. |
| 14 | S&F plate girder or single stanchions, built up of one beam or channel section with flange plates, caps bases, splices, agnle brackets cleats and other connection confirming to Fe-410-W (Gde-E-250) quality-Acomplete all as specified and directed. |
| 15 | S&F rolled section as in framing for door/ vent/ CB chowkhats and the like fixed with angle cleat and connecting plates etc. using FE-410W (Grade E-250 quality \"A\") (Butt hinges shall be measured and paid for separately), complete in all respect as specified and directed. |
| 16 | S & F for Factory made single extruded WPC (wood polymer composite) solid door/ window / ceosetory windows & other frames / chowkhat of size 50x125 mm comprising of virgin PVC polymer of K value 58-60 (suspension Grade), calcium carbonate and natural fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having maximum frame density of 750 kg / cum, screw withdrawel strength of 2200 N (Face) & 1100 N (Edge), minimum comprssive strength of 58 N / mm², Modules of elasticity 900 N / mm² and resistance to spread of flame of class A category with property of beeing termite / borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast / lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast / lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door / window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 17 | S & F for Factory made single extruded WPC (wood polymer composite) solid door/ window / ceosetory windows & other frames / chowkhat of size 65x150 mm comprising of virgin PVC polymer of K value 58-60 (suspension Grade), calcium carbonate and natural fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having maximum frame density of 750 kg / cum, screw withdrawel strength of 2200 N (Face) & 1100 N (Edge), minimum comprssive strength of 58 N / mm², Modules of elasticity 900 N / mm² and resistance to spread of flame of class A category with property of beeing termite / borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast / lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast / lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door / window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 18 | Factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/ Chowkhat of size 65 X 100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face)& 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/ss dash fasteners of required dia and length complete as per direction of enineer-in-Charge (M.S. hold fast/lugs or SS dash fastener shall be paid for seperately)Note: For WPC solid door/windows frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 19 | M&L for cement concrete in coping, hold fasts using type B-1, 1:2:4 (using 20 mm nominal size crushed and graded stone aggregate) or of similar type of work including necessary formwork complete in all respect as specified and directed. |
| 20 | S&F coloured 0.50 mm thick pre-painted galvalume aluminium zinc coating GI based trapezoid profile steel sheet having tensile strenght of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws with bitumen washer to truss members of any material, complete in all respect as specified and directed. |
| 21 | S&F coloured 0.50 mm thick pre-painted galvalume aluminium zinc coating GI based trapezoid profile steel sheet having tensile strenght of 550 Mpa as in ridge, valley gutter or of similar type, fixed with self tapping screws with bitumen washer to truss members of any material, complete in all respect as specified and directed. (The measurement shall be carried out as in a plain sheet). |
| 22 | S&F coloured 0.50 mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet having tensile strenght of 550 Mpa as in eves covering or of similar type, fixed with self tapping screws with bitumen washer over mild steel flats, angles etc. and screws for fixing with framed structure complete in all respect as specified and directed. (Note:- MS work shall be measured and paid separately). |
| 23 | S&F exposed GI powder coated snap grid frame work for false ceiling in flat or in sloping, of grid size 600 x 600 mm comprising of wall/ cleat angle of size 25x25x0.35 mm and corss tee of size 24x38x0.70 mm with 4 mm dia GI wire as suspender and including 4 mm thick decorative pre-painted non asbestos board (E-Board) in false ceiling including fixing arrangement from steel/ wooden truss of any type including dismantling of existing false ceiling boards, complete in all respect as specified and directed. (Make:- Eternit, Everest or equivalent) |
| 24 | Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick screed bed in cement mortar (CM) 1:6, complete in all respect as specified and directed. |
| 25 | Providing and laying coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.08 sqm but not exceeding 0.15 sqm, in skrting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick rendering in cement mortar (CM) 1:4, complete in all respect as specified and directed. |
| 26 | M&L for 10 mm thick on fair faces of brick work or concrete surfaces of mortar in CM 1:3 fixing of tiles in wall,dado complete all as specified and directed. |
| 27 | M&L for any colour of granite stone without white spots Granite stone slab 17 to 19 mm thick, as in floor, dado, steps, laid over and including screed bed 15 mm thick in cement mortar (CM) 1:6, jointed and pointed with white cement mixed with pigment to match the shade of stone including cuttingl rubbing and polishing surface, including cutting for wash hand basin, sink, gas pipe hole etc., to the entire satisfaction of the Engineer-in-Charge, complete in all respect as specified and directed. |
| 28 | M&L for 18-20 mm thick machine cut kota stone slab flooring of size not less than 500 x 500 mm over 15 mm thick cement mortar (CM) 1:6 screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete in all respect as specified and directed. |
| 29 | M&L for 18-20 mm thick machine cut kota stone slab of size not less than 500 x 500 mm in riser of steps, skirting, dado and pillar over 15 mm thick rendering in cement mortar (CM) 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete in all respect as specified and directed. |
| 30 | Taking down of existing roof treatment from roof and terrance, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following specification:-(a)Applying cement slurry over concrete surfaces @3kg/sqm. (b)Rendring 15mm thick in cement mortar (1:4) mixed with water proffing compound as per manufactures instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course).(c)Applying evenly one coat of cold bituminous primer conforming to [email protected] liter per square metre on the cleaned plastered surfaces(d)Applying evernly one coat of blown hot bitumen of grade 85/25@ 1.20 Kg per square metre on primed surfaces.(e)Applying a layer of APP based polymeric membrane, 3mm thick (minimum) weighing 3.50 Kg per square metre reinforces) with polyster non woven fabric wighing not less than 160 gms per square metre by torch application.The overlap shall be not less than 100mm on transverese direction and 75mm on longitudinal direction and sealing overlsaps.(f) Applying evenly one coat of aluminium paint @ 0.10 litre per square metre over the APP based polymeric membrane. |
| 31 | Taking down existing damaged EWC alongwith complete PCC and cement concrete from sunken floor and providing new EWC and seat cover and water proofing treatment to sunken floor as per following stages:-(a) 15 mm thick plastering in CM (1:3) with WPC at all around wall and base of sunken floor with proper slope.(b) Applying a coat of 85/25 gde hot bitumen @ 1.2Kg/ Sqm over a coat of bituminous primer @0.5Kg/Sqm and then pasteing of polythene film, 50 micron, natural colour with cold cut back adhessive. (c) Fixing of 25mm dia GI pipe (mediumgrade) spout of length 45 cm. (d) Supply & fixing of vitreous china wash down water closet pan (pedestal pattern), white, seat cover and P or S type bend etc complete includingproviding cement concrete and cement filling (1:5:10) and 25 mm thick PCC 1:2:4 at top surface.. |
| 32 | M&L 15 mm thick plastering on brick/ stone/ concrete surfaces of wall in cement mortar (1:4), finished even & smooth without using extra cement, complete in all respect as speicifed and directed. |
| 33 | M&L 15 mm thick plastering on brick/ stone/ concrete surfaces of wall in cement mortar (1:6), finished even and smooth without using extra cement, complete in all respect as spefied and directed. |
| 34 | M&L 10 mm thick plastering on brick/ stone/ concrete surfaces of ceiling in cement mortar (1:3) finished even and smooth without using extra cement, complete in all respect as specified and directed. |
| 35 | Supply only water proofing compound complete, in all respect as specified and directed. |
| 36 | M & L for Broken stone orboulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete in all respect as specified and directed |
| 37 | S & F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; and similar work conforming to Fe. 290, Gde-E-165complete in all respect as specifified and directed. |
| 38 | S & F CPVC pipes SDR 11 and plain CPVC SDR-11 fittings on walls/ceiling or laying in floors/concealed in wall of size 20mm outer dia complete all as specified and directed. |
| 39 | S & F CPVC pipes SDR 11 and plain CPVC SDR-11 fittings on walls/ceiling or laying in floors/concealed in wall of size 25mm outer dia complete all as specified and directed. |
| 40 | S&F in repair 20 mm bore of Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed, complete in all respect as specified and directed. |
| 41 | Providing and fixing in position kitchen cup board box type as per design and directed of 550-600mm deep, fixed over wall with PVC gittie and screws/or in beneath of kitchen counter, cup board, kitchen cabinet in required sizes as per site made out of 17-18mm thick one side decorative lamination and other side balancing lamination sheet consisting of carcass 17-18mm thick PVC sheet. Provision of shelves, shutters, back side, top, bottom, side, made out of 17-18mm thick one side decorative laminated PVC sheet , all required brackets, screws etc,. The panel shall be fabricated using adhesives and screws whereever required. All the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish as per maufactures specifications and drawing including 15mmX20mm medium grade chrome finish two nos per leaf, slip on cabinet hinge/self-closing hinge, soft close hydraulic 4 hole cabinet auto cup hinge full overlay O crank with soft closing of make Godrej/Avis L Bihari/Hettich/Harrison and 50mm SS handle size all items each per shutter including taking down of existing box complete in all respect as specified and directed.(Note: For payment, measurement shall be taken as front portion of cup board measurement only, rest other items/materials as specified shall not be measured or paid as these are included in this item) |
| 42 | Providing and fixing in position kitchen cup board box type as per design and directed of 250-300mm deep, fixed over wall with PVC gittie and screws/or in beneath of kitchen counter, cup board, kitchen cabinet in required sizes as per site made out of 17-18mm thick one side decorative lamination and other side balancing lamination sheet consisting of carcass 17-18mm thick PVC sheet. Provision of shelves, shutters, back side, top, bottom, side, made out of 17-18mm thick one side decorative laminated PVC sheet , all required brackets, screws etc,. The panel shall be fabricated using adhesives and screws whereever required. All the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish as per maufactures specifications and drawing including 15mmX20mm medium grade chrome finish two nos per leaf, slip on cabinet hinge/self-closing hinge, soft close hydraulic 4 hole cabinet auto cup hinge full overlay O crank with soft closing ofand 50mm SS handle size all items each per shutter including taking down of existing box complete in all respect as specified and directed. Make: Rajshri Plastiwood, Sintex or of appd make. (Note: For payment, measurement shall be taken as front portion of cup board measurement only, rest other items/materials as specified shall not be measured or paid as these are included in this item) |
| 43 | S & F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. or for window grill of appd size and shapeincluding fixing with aluminium \"U\" shape section for fixing etc. complete in all respect as specified and directed. (Powder coating shall be min 50micron) (Note:all external members to be joined at 45 degree angle at corner) |
| 44 | S & F powder coated aluminium three tier window frame including necessary joining cleats, of Jindal section No 20832 or equivalent section of appd make of 1.5mm thick complete in all respect as specified and directed. (Powder coating shall be min 50micron) (Note:all external members to be joined at 45 degree angle at corner) |
| 45 | S & F powder coated aluminium window and ventilator shutters, side hung type with/without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, EPDM rubber packing (of 50 No) grade), powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21, 100mm long (2 no.) suitable handle (1 no.) complete in all respect as specified and directed. (Powder coating shall be min 50micron) (Note:all external members to be joined at 45 degree angle at corner) |
| 46 | S & F powder coated aluminium sliding window with/without sash bars, aluminium sections of thickness 2mmincluding necessary joining cleats, glazing clips, EPDM rubber packing (of 50 No grade), powder coated aluminium snap beading, screws, center grooved stainless steel ball-bearing double roller2 position height adjustment, sound/dust brush, recessed handle with locking arrangement complete in all respect as specified and directed. (Powder coating shall be min 50micron) (Note:all external members to be joined at 45 degree angle at corner) |
| 47 | S&F 65 mm size of butt hinges stainless steel, complete in all respect as specified and directed. |
| 48 | S&F 75 mm size of butt hinges stainless steel, complete in all respect as specified and directed. |
| 49 | S&F 100 mm size of mild steel butt hinges ISI marked, complete in all respect as specified and directed. |
| 50 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides.M.S. stay shall be provided at the bottom to steady theframe., complete as specified by the manufacturer and as per directions of Engineer-in-charge. |
| 51 | Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge. |
| 52 | S&F 25 mm thick Flush shutters, solid core construction, with block board core with decorative face veneers withlipping on both sides, complete in all respect as specified and directed. |
| 53 | S&F 35mm thick second class HW glazed and skeleton shutters, open rebated and prepared to receive glass gauge etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass etc.; sizes of members of shuttrs as specified in SSR Part-I, section 8, clause 8.24 (a), complete in all respect as specified and directed. |
| 54 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 55 | S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 sqm in each pane, complete in all respect as specified and directed. |
| 56 | S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane, complete in all respect as specified and directed. |
| 57 | S&F stainless steel wire cloth,0.36 mm nominal dia of wire and average width aperture 1.40 mm and fixed with stainless steel wire staples fixing withbeads, complete in all respect as specified and directed. |
| 58 | S & F for Mild Steel, plain, black sheet1.25 mm thickin hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughts; ducts; urinal troughts and funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending turning up, mitred angles, stopped ends, outlets, etc. as required, complete in all respect specified and directed. |
| 59 | S&F 25 mm thick Flush shutters, solid core construction, with block board core with decorative face veneers withlipping on both sides, complete in all respect as specified and directed. |
| 60 | S&F 35mm thick Flush shutters, solid core construction, with block board core with decorative face veneers with lipping on both sides, complete in all respect as specified and directed. |
| 61 | S & F 18-19mm block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work including necessary leaping/edge margin of 3mm thick complete in all respect as specified and directed. |
| 62 | M&L for Sand filling under floors or infoundations including wateringand consolidation complete in all respect as specified and directed. |
| 63 | M & L for applying Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, at the junction of Perimeter of the building and every 3 mtr in the lateral dimension all as specified and directed. |
| 64 | S&F aluminium anodised, barrel tower bolt of extruded section 200 mm long, complete in all respect as specified and directed. |
| 65 | S&F Aluminium handle cast type anodised 125 mm, complete in all respect as specified and directed. |
| 66 | S&F aluminium anodised sliding door bolts with hasp and staple (boilt type) 16 mm dia bolt, 250 mm long, with and including a minium of 6 bolts and nuts four on bolt plate and two on staple plate, complete in all respect as specified and directed |
| 67 | S&F mild steel 300 mm, ordinary rat tail rod pattern springs, including roller and roller plate, complete all as specified and directed. |
| 68 | S&F 100 mm size of mild steel butt hinges ISI marked, complete in all respect as specified and directed. |
| 69 | S&F PVC coloured insulated over MS pipe 20 mm dia curtain rod with fixing bracket, stops, rollers etc. complete all as specified and directed. |
| 70 | S&F 4 mm thick of size 600 mm x 450 mm bevelled edge mirror of selected quality decorative type mounted on 6 mm commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete in all respect as specified and directed. |
| 71 | S&F plate rack made out of stainless steel sheet 0.50 mm thick overall size 900 mm (W) x 760 mm (H) x 250 mm (D) with three shelf, complete in all respect as specified and directed |
| 72 | S&F sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to drarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm, complete in all respect as specified and directed. |
| 73 | S&F three layered white in colour rotational moulded made out from LLDPE material water storage tanks of capacity 1000 ltr (cylindrical vertical with closed top) including three tank nipples of 20 mm nominal bore dia hoisted and fixed in position including dismantling/ taking down all as specified in SSR part I, complete in all respect as specified and directed. |
| 74 | S&F PTMT ball valve high pressure 20 mm bore with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe, complete in all respect as specified and directed. |
| 75 | S & F in repair 15mm bore concealed long neck , CP finished stop valves, cast copper alloy, screwed down, highpressure, withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions and fixed complete in all respect as specified and directed. |
| 76 | S&F in repair vitreous chinaware sqatting pan of size 580 x 440 mm, \"ORISSA PATTERN\" with new PVC \"P\" or \"S\" trap bedded in cement concrete (excluding flushing cistern and flush pipe) with integral foot rests, complete in all respect as specified and directed. |
| 77 | S&F in repair PVC valveless, syphonic action type, low level dual flush cistern 10 ltr capacity, white, wtih inlet, ball valve, float and handle including brackets & flush pipe of polyethylene for low or high level cistern of required height of high density PVC, 32 mm dia pipe, complete in all respect as specified and directed. |
| 78 | S&F PVC connection 15 mm size with PTMT nuts of length 450 mm, complete in all respect as specified and directed. |
| 79 | S&F in repairs 15 mm bore fancy type CP finished angle valves, cast copper alloy, screwed down, high pre-ssure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete in all respect as specified and directed. |
| 80 | S&F in repairs long body Bib taps of 15 mm bore, fancy type CP finish cast copper alloy with crutch handle, screwed down, screwed for iron pipes, complete in all respect as specified and directed. |
| 81 | S&F in repairs short body Bib taps of 15 mm bore, fancy type CP finish cast copper alloy with crutch handle, screwed down, screwed for iron pipes, complete in all respect as specified and directed. |
| 82 | S&F in repair for 15 mm bore pipe brass chromium plated (CP) shower rose 125 mm size, fixed to iron pipe, complete all as specified and directed. |
| 83 | S&F Tubular towel rail, 20 mm dia, D type, 60 cm long between flanges cast copper alloy, chromium plated finish, complete in all respect as specified and directed. |
| 84 | S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long, complete all as specified and directed. |
| 85 | S&F in repair wash hand basins (WHB), vitreous china of size 550x400 mm (flat back or angle back type) with pedastal stand, including cutting for and pinning in ends of brackets over new angle iron erecting stand embedded in PCC (1:2:4) block including 32 mm dia bore waste fittings cast copper alloy chromium plated with long screwed shanks and flynuts flange and beded in redlead cement, PVC waste pipe including 15 mm bore dia fancy type CP finish pillar tap, cast copper alloy with capstand heads, screw down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screw for iron pipes complete in all respect as specified and directed. |
| 86 | S&F in repair Health faucet ABS SS braided hose 1 mtr with V hook including fixing arrangement, complete in all respect as specified and directed. |
| 87 | S&F 75 mm dia of outlet, PVC (SWR) nahani trap, plain with SS grating of size 150mmX150mm, 0.75mm thick openable at center including jointing with solvent cement, complete in all respect as specified and directed. |
| 88 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm bore including necessary MS pipe clamp, complete in all respect as specified and directed. |
| 89 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75mm bore including necessary MS pipe clamp, complete in all respect as specified and directed. |
| 90 | S&F PVC (SWR) pipes single sockedted in any length with rubber ring joints laying in trenches 110 mm bore, complete in all respect as specified and directed. |
| 91 | S&F PVC (SWR) pipes single sockedted in any length with rubber ring joints laying in trenches 75 mm bore, complete in all respect as specified and directed. |
| 92 | S&F PVC (SWR) single (single \"T\") equal or unequal 110mm bore pipe with access door, complete in all respect as specified and directed. |
| 93 | S&F PVC (SWR)single (single \"T\") equal or unequal 75mm bore pipe with access door, complete in all respect as specified and directed. |
| 94 | S&F PVC (SWR) bends any radius 110 mm bore, complete in all respect as specified and directed. |
| 95 | S&F PVC (SWR) bends any radius 75 mm bore, complete in all respect as specified and directed. |
| 96 | S&F PVC (SWR) vent cowl 110 mm dia bore, complete in all respect as specified and directed. |
| 97 | S&F PVC (SWR) vent cowl 75 mm dia bore, complete in all respect as specified and directed. |
| 98 | S&F unplasticised PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 160mm outside diameter as per IS:13592-1992 including dismantling and breaking up existing drain pipes and fixing necessary mild steel pipe clamps complete in all respect as specified and directed. |
| 99 | S&F unplasticised PVC (SWR) bends any radius for160mm outside diameter of pipeas per IS:14735-1999 complete in all respect as specified and directed. Make: Supreme, Prince, Oriplast. |
| 100 | S&Funplasticised PVC (SWR) junction single, (single Tee) equal or unequalfor160mm outside diameter of pipe as per IS:14735-1999 complete in all respect as specified and directed. Make: Supreme, Prince, Oriplast. |
| 101 | S&F unplasticised PVC (SWR) Gully trap125/110 mm, setting and jointing with solvent cement complete in all respect as specified and directed. Make: Supreme, Prince, Oriplast. |
| 102 | Surface excavationn.exc 30 cm deep and averaging 15 cm deep geeting out in soft/loose soil. |
| 103 | M&L for PCC (1:4:8) type D2 (using 40mm crushed and graded stone aggregate)as in foundaion and mass fillingcomplete in all respect as specified and directed |
| 104 | M&Lfor reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; complete in all respect as specifified and directed. |
| 105 | M&Lfor reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in columns, posts, struts etc. complete in all respect as specifified and directed. |
| 106 | M&Lfor reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in beams, lintels, etc.; complete in all respect as specifified and directed. |
| 107 | M&L for precast RCC, type B-1, 1:2:4 (using 20 mm crushed and graded stone aggregate) as in manhole covers/ cover slabs or of similar type slab works, etc. incl necessary formwork and loading/ unloading of the same and fixed in position, complete in all respcet as specified and directed. |
| 108 | M&Lreinforced concrete slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like using 1:2:4type B-1, (using 20 mm crushed and graded stone aggregate) complete in all respcet as specified and directed. |
| 109 | M&Lfor cement concrete in coping, hold fasts using type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) or of similar work, etc. including necessary form workcomplete in all respect as specifified and directed. |
| 110 | M & L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all not exceeding 20cm wide complete in all respcet as specified and directed. |
| 111 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete in all respcet as specified and directed. |
| 112 | M & L forformwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished flat surface of concrete complete in all respect as specifified and directed. |
| 113 | M & L forformwork to sides of pillars, posts, struts, piers,columns and stanchionsin rough finished flat surface of concrete complete in all respect as specifified and directed. |
| 114 | M & L forformwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. in rough finished flat surface of concrete complete in all respect as specifified and directed. |
| 115 | S&F 10 mm dia and over TMT bar cut to length bent to shape required including cracking bending spiarlly for hoping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.90 mm dia or securing with clip, complete in all respect as specified and directed. |
| 116 | M & L for deformed TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, cut to length, bent to shape required, including cranking, bending spirallyfor hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete in all respect as specifified and directed. |
| 117 | M&L for plinth protection or in foot path of 75 mm thick of cement concrete using type C-1, 1:3:6 (using 20 mm nominal size crushed and graded stone aggregate) in alternate penals and finished fair and even complete in all respect as specified and directed. |
| 118 | Complete removal of existing treatment on wall/ roof projections incl facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust loose paint etc by skilled labour complete all as specified and as directed |
| 119 | Complete removal of existing treatment on ceiling/ roof projections incl facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust loose paint etc by skilled labour complete all as specified and as directed |
| 120 | M & L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive and color stay Techonology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifieecations, Anti Algal properties in two coats @ 1.79 ltr (Undiluted)/10 Sqm with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow spreed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in both coatsof paint complete all as specified and directed.Note :(a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item. |
| 121 | M & L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the newly plastered surfaces of wallto prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructionsi.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) Masking of waindow/doors during spray painting using polythine film will be included (d) Cleaning and clearing site of paint, mats etc included. |
| 122 | M & L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the newly plastered surfaces of ceiling to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructionsi.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) Masking of waindow/doors during spray painting using polythine film will be included (d) Cleaning and clearing site of paint, mats etc included. |
| 123 | M&L for preparation of newly plastered surface of wall and applying two coats of weather coat over 2 mm thick wall care putty over a coat of alkali resistant primer including necessary preparation of surface, complete in all respect as specified and directed. |
| 124 | M&L for Preparation of undecorated plastered or unplastered surface of Wall and applying two coats of white wash complete all as specified and directed. |
| 125 | M&L for preparation of new plastered or undecorated surfaces of wall using wall care putty to fill the voids and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed. |
| 126 | M&L for preparation of newly undecorated plastered surface of wall and applying two coats of oil bound distemper (OBD) and finished another one coat with spunge roller over one coat of alkali resistant priming paint over 2 mm thick (in two layers), wall care putty, complete in all respect as specified and directed. |
| 127 | M&L for preparation of newly undecorated plastered surface of Ceiling and applying two coats of oil bound distemper (OBD) and finished another one coat with spunge roller over one coat of alkali resistant priming paint over 2 mm thick (in two layers), wall care putty, complete in all respect as specified and directed. |
| 128 | M&L for preparing of new undecorated wooden surface, of any description, not otherwise described, overe 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer, complete in all respect as specified and directed. |
| 129 | M&L for preparation of new undecorated steel surface of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete in all respect as specified and directed. |
| 130 | M&L for preparing of old decorated wooden surface, of any description, not otherwise described, over 10 cm width or girth, and applying two coats of synthetic enamel paint, complete in all respect as specified and directed. |
| 131 | M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil, complete in all respect as specified and directed. |
| 132 | M&L for preparation of old decorated steel surface of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint, complete in all respect as specified and directed. |
| 133 | S & F of polythene film black 150micron |
| 134 | Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge. |
| 135 | Taking down ceiling fan of any type and size and keep in safe custody for refixing after completion of work complete all as specified and as directed by Engineer-in-charge. |
| 136 | Taking down old submain wiring of any type/ core including earth wire including batten/ PVC conduit/ casing caping and making good the disturbed surface to match with the existing complete all as specifid and as directed. |
| 137 | Taking down old MCB DB of any type and size and making good the disturbed surface to match with existing complete all as specified and as directed. |
| 138 | Taking down old MCB (SP/SPN) of any type and size complete all as specified and as directed. |
| 139 | Taking down street/security light fittings /Tube light fittings of any capacity or type from pole/wall after disconnection and connecting wires, carrying to store yard for necessary repair/replacement of spares etc. complete all as specified and directed. |
| 140 | Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLS, PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLS copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed by Engineer-in-Charge.NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. |
| 141 | One Light point/ Fan point/ Exhaust fan point controlled by one, one way switch complete all as specified anddirected. |
| 142 | One Socket outlet 3 Pin, 5 Amp on same board complete, all as specified and directed. |
| 143 | One bell point controlled by one, one way switch complete, all as specified and directed. |
| 144 | One Light point controlled by two, two way switch complete, all as specified and directed. |
| 145 | All as per item No 40 above but one Socket Outlet Point, 5 Amp on independent board with 2.5 Sqmm cable complete all as specified and as directed by Engineer-in-charge. |
| 146 | All as per item No 40 above but one Socket Outlet Point,15 Amp on independent board with 2.5 Sqmm cable all as specified and as directed by Engineer-in-charge. |
| 147 | S&Fmodular switch 1 way 6A, 1 module complete all as specified and as directed. |
| 148 | S&Fmodular switch 1 way 16A, 1 module complete all as specified and as directed. |
| 149 | S&Fmodular switch 2 way 6A, 1 module complete all as specified and as directed. |
| 150 | S&F modular bell push 1 way 6A, 1 module complete all as specified and as directed. |
| 151 | S&Fmodularsocketoutlet 2 in 1 , 3/5 pin 5Amp, 230 volts flush type (non shuttered)complete all as specified and as directed. |
| 152 | S&Fmodular socket 6A-2/3 pin combined 2 module complete all as specified and as directed. |
| 153 | S&Fmodular socket 6/16A-2/3 pin combined 2 module complete all as specified and as directed. |
| 154 | S&Fmodular fan regulator step type 2 module complete all as specified and as directed. |
| 155 | S&F Bulb angular/batten holder/ PVC/polycarbonate angular lamp holder insulated body with back plate angle type suitable for batten fittingcomplete all as specified and directed by Engr-in-charge . |
| 156 | M&L for ceiling rose, surface Bakelite of three terminals PVC/Polycarbonate,isolated body (ISI Marked) complete all as specified and as directed by Engineer-in-charge. |
| 157 | S&F Call bell multi music type AC 230 volts, single pole (ISI Marked) & connection complete all as specified and as directed. |
| 158 | S&F of LED light fitting 1x20W, 220V, AC, batten type with driver , holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector of any description and in any position complete all as specified and directed by Engineer-in-charge. |
| 159 | S&F of integrated LED batten 9/10 watt, 2 feet long tube light fitting with high efficient diffuser mirror light,, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of the light/fitting of any description and in any position complete all as specified and directed by Engineer-in-charge. |
| 160 | S&F of LED security light luminaire 30/35 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDshaving optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting acomplete all as specified and directed. |
| 161 | S&F LED tube light fitting 4 ft. 1 x 18/20 watt with 230 volts AC, complete with all accessories internally pre-wired and fixed to walls/ceiling with screw including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. |
| 162 | S&F street light bracket favricated out of GI Tubing light grade 32mm bore bend to the shape as directed and of the length 1.5 m complete with suitable mounting MS clamp of flat iron size 40x5mm of suitanle length 02 pairs including nuts, bolts, and washers etc for suitable size, complete and specified and directed. |
| 163 | M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying, including filling cavities with filler, one coat after cleaning all dust etc including servicing and minor repair complete all as specified and as directed. |
| 164 | Fixing only ceiling fan (taking down against item No 02 above) of any type including provision of flexible copper cable of suitable size from ceiling fan to ceiling rose complete all as specified and as directed. |
| 165 | S&F of ceiling fans complete with blades, down rods, electronicregulator and accessories, 230 V, 1200 mm sweep. min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engineer-in-charge. |
| 166 | S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-charge. |
| 167 | S&F of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and as directed by Engineer-in-charge. |
| 168 | Supply and fixing electric water heater (Geyser) storage type 25 Ltr capacity vertical mounting type, BEE 5 Star rated, 230V, 50 Hz, 2000 watt with suitable size fastner including provision and connecting up suitable size and length of SS braided pipe with adaptor for inlet and outlet water connection. Geyser of metal body water proof and rust proof, water resistnace & splash proof (IPX4). inner tank superior glass line enamel coating single weld line,heavy duty magnesium anode rod, Corrosion resistance, PUF insulation for radient heat loss and energy saving. Temprature gauge and adjustable knob for temperature setting, auto cut off, capillary thermostat, multiple safety system for protection against dry heating, over heating and over pressure, rated water pressure 8 bar, whirl flow technology, anti rust copper element, safety valve, NRV including all fixing accessories all as specified and as directed.Note :(i) Minimum 2 year warrenty on product(ii)Minimum 3 year warrenty on heating element.(iii) Minimum 7 year warrenty on inner tank. |
| 169 | Supply, installation, testingofSPN distibution board 8 way,double door , IP 43, as per IS 8623including minimum IP 43 degree of protection with built in fully insulated copper bus bar, not less than 100 Amps capacity insulated neutral bar and earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed by Engineer-in-charge. |
| 170 | Supply and fixing of MCB 25 to 32 Amp SP&N, 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs complete all as specified and directed. |
| 171 | Supply and fixing of MCB 6 to 32 Amp SP, 240 voltss 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs complete all as specified and directed. |
| 172 | Supply and fixing of single pole and neutral enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Voltscomplete all as specified and as directed. |
| 173 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete,complete all as specified and as directed. |
| 174 | M & L for providing sub main wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through including concealed PVC Conduit of suitable sizeincluding 6.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wirecomplete all as specified and directed by Engineer-in-charge. Note : (i) Three runs of single core 6.00 Sqmm multi stranded copper cableand one run of conduit shall be measured as one run length (ii)cutting chasing and making good to the disturbed srface shall be included in quoted rates. |
| 175 | All as per Ser item No 31 above but with 4.00 sqmm copper cable (nominal area) |
| 176 | M & L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion, complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth wire up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II. |
| 177 | Supply and fixing of sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door, 415 volts with 200 amps rated bus bar IP 43 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingMCCB 4 pole thermal release type, 100 Amps, 16 KAas incomer and MCBsas out going complete with making suitable size of MS cabinet as per IS dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface complete all as specified and directed by Engineer-in-charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail