| 1 | Renovation of Rooms for installation of QQQ-ICPMS |
| 2 | Coolie for cutting,conveyingand removing theold & ddeteriorated log pieces lying on the ground at site |
| 3 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 4 | Demolishing R.C.C. work manually/ or by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 5 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin-charge. |
| 6 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction In cement mortar |
| 7 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 8 | Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction |
| 9 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed |
| 10 | Dismantling cement asbestos or other hard board (or PVC panel false) ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 11 | Dismantling C.I. or asbestos rainwater pipe with fittings and clamps including stacking the material within 50 metres lead :or Dismantling C I. (centralised) Air-Conditioner ppipes wrappedwith insulation materials including stacking the materials within 50m lead 150mm dia pipe |
| 12 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction upto 150 mm diameter metre |
| 13 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction above 150 mm diameter upto 300mm dia metre |
| 14 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres |
| 15 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 16 | Taking outdoors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead Of area 3 sq. metres and below |
| 17 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) |
| 18 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed All kinds of soil |
| 19 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kinds of soil |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 22 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 23 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 24 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 25 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 27 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 28 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 30 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 31 | Excavating, supplying and filling of local earth (including royalty) bymechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 32 | Supplying and stacking for mearurementearth at site including royalty and carriage upto 5km lead, all labour charges for stacking ,loading and unloading etc complete |
| 33 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 34 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) |
| 35 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 36 | 12 mm cement plaster: 1:4 (1 cement : 4 fine sand) |
| 37 | 12 mm cement plaster finished with a floating coat of neat cement : 1:3 (1 cement : 3 fine sand) |
| 38 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 39 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 40 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 41 | Providing and fixing T-iron frames for doors, windows and ventilatorsofmildsteel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 42 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction |
| 43 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 44 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wireand 1.4 mm aperture on both sides |
| 45 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm) |
| 46 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction, 75mm average thickness |
| 47 | 50mm average thickness |
| 48 | 25 mm average thickness |
| 49 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing looseparticles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction Bars up to 12 mm diameter |
| 50 | Bars above 12 mm diameter |
| 51 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 52 | Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make |
| 53 | Providing, mixing and applying SBR polymer (of approved make)modified Cement mortar in proportion of 1:4 (1 cement: 4 gradedcoarse sand with polymer minimum 2% by wt. of cement used) asper specifications and directions Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). 12 mm average thickness. |
| 54 | Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness.Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super- Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument) 50mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 55 | 75mm thick in Grade M 25 with cement content not lessthan 330 kg per cum |
| 56 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles ofapproved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction In flooring on a bed of 10 mm thick mortar 1:4 (1 acidproofcement :4 coarse sand)Acidand alkali resistant tile |
| 57 | In dado/skirting on 12 mm thick mortar 1:4 (1 acid proofcement : 4 coarse sand) Acid and alkali resistant tile |
| 58 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm |
| 59 | Providing and laying Vitrified tiles in different sizes (thickness to bespecified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm |
| 60 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. |
| 61 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction Size of Tile 600x600 mm |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints complete as per direction 25 mm nominal dia Pipes |
| 63 | 32 mm nominal dia Pipes |
| 64 | 40 mm nominal dia Pipes |
| 65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes |
| 66 | 25 mm nominal dia Pipes |
| 67 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approvedmake conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling upthegaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 68 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 69 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions Pre-laminated particle board with decorative laminationon both sides |
| 70 | Providing and fixing 04 mm thick Aluminium Composite Panel, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions Pre-laminated particle board with decorative lamination on both sides |
| 71 | Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and thedirections(Cost of aluminium snap beading shall be paid in basicitem): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 72 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm |
| 73 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 74 | Supplying and fixing Aluminium handle with locking arrangements suitable for aluminium windows. |
| 75 | Supplying and fixing 300 mm Aluminium aldrop |
| 76 | Supplying and fixing I-max hinges |
| 77 | Providing and fixing stainless steel (SS 304 grade) adjustablefriction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per directioncomplete. 205 X 19 mm |
| 78 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 79 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Powder coated minimum thickness 50 micron aluminium |
| 80 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 81 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 82 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 83 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 84 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters |
| 85 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick Second class teak wood |
| 86 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 87 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threadedstar headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 100 mm |
| 88 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter ofrequired size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded starheaded counter sunk S.S screws, all as per direction (Note: stainless steel butt hinges and necessary S.S screwsshall be paid separately) 35 mm thick |
| 89 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 125x64x2.50 mm |
| 90 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm |
| 91 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 92 | Providing and fixing bright finished brass handles with screws etc.complete: 125mm |
| 93 | Providing and fixing aluminium die cast body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 94 | Supply and installation of 3mm Thick Wonderfloor- Chalenger collection Multipurpose highperformance Vinyl roll Flooring conforming to IS 3462-1986 and RDSO-C-8515 equivalent to BS 3261A – Ocean Blue shade. To be installed on mosaic subfloor which is smooth, clean, dry and structural sound with recommended adhesive (Fevicol SR 505 / 998) and joints with hot weldingand coving etc. to make it seamless and even |
| 95 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 96 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 97 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 98 | Providing and applying white cement-based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 99 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work |
| 100 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work |
| 101 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface |
| 102 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 sqm |
| 103 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 104 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 105 | Providing and applying two coats ofelastomeric liquid water proofing membrane with resilient acrylic polymers (such as DrFixit-Rain-coat Star or likewise materials of other brand) on wall surfaces without water dilution (ensuring a coverage rate of 4.2-4.5 m2/ Lit/two coats to achieve a DFT of upto 90-100 microns) over a single priming coat of self-penetrating acrylic white Primer having dilution with water in the ratio 2:1 and spreading at the rate of 8-10 sqm./Lit/coat for superior bonding and hiding. Before applying Priming coat, area must be pressure-washed with water jet having a minimum working pressure of 1400psi to remove all dirts, dust and waste products. Then, cut and open the non-structural hairline cracks less than 0.50mm in width upto 10mm with mechanical cutter and clean, moisten the surface cracks and fill the cracks with \"Crack-X-shrinkfree\" crack filler by using a putty-blade. Apply two surface coats after allowing the primer coat is cured for 4-5 hours and keep the surface coat dry for 4-6 hours to achieve the required DFT and allow it be undisturbed for 7 more days to become fully cure.The surface coats should have the following technical properties: a hair line crack bridging upto 1mm; elongation of > 100% a per ASTMD 412; tensile strength of 3.5MPa per ASTM D412; adhesion strength of 2MPa as per ASTM D541; The system comes with 5-year waterproofing and 7-year paint performance warrenty from the Company concerned. |
| 106 | Melamine polishing on woodwork (one or more coat). |
| 107 | Polishing in high gloss/matt finish melamine clear polish on wood workin required color/wooden shade texture with following process in thesequence as detailed below:1.The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficientdrying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3.On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4.On this, 1st coat of melamine polish is applied with spray gun usingmelamine clear polish and melamine thinner in required proportion.This 1st coat is allowed to dry for 24 hrs then this dry surface is againfine wet rubbed smooth, which is further allowed to dry for 12 hrs. Thefinal melamine polish is applied with compressor pressure spray gunusing melamine clear polish and melamine thinner mixed in requiredproportion complete as per direction (Finalcoat to be done in 1 or 2 layers without gap of time.) |
| 108 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction |
| 109 | Modified cost on DSR item after using Correction factor on DSR 2023 on account of GST @ 0.973 add 36% towards cost index of 136 approved for Trivandrum (832101.96 – 66139.18 = 765962.78) |
| 110 | APPENDIX-B (HVAC with CLEAN Room facilities) VRF Outdoor UnitSupplying, Installation,Testing&CommissioningofModulartype Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having100%hermeticallysealed invertertypetwin Rotary/Scroll Compressor(s), minimumtwocompressors(withindividual separatePCB)forabove14HPmodules, microprocessorbasedController,topdischarge type condensingunit(s), with R-410-A Refrigerant or equivalent, vibration Isolators withsuitable foundationetc.completeasrequired.Tohave better efficiency condenser fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmationasperIS18728:2024andCPWD Specificationsandworkevenat50°Cambienttemperaturewithout tripping.The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V +/-10%,3 Phase,50Hz AC power supply and BMS compatible. The unit shall be filled with first charge oftherefrigerantandreadyforuseas required. Thecondensershouldbecoatedwitha hydrophilicfilm to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk ofdegradation, thereby improving overall performance and durability. The Indian SeasonalEnergy EfficiencyRatio (ISEER) oftheunitshallbeasperEnergyConservation and SustainableBuilding Code (ECSBC) 2024 as belowandcompleteas perCPWD specification, connections,interconnectionsetc.asrequired. (For capacity <40 kWr ISEER7.4, Capacity > 40 and <70 ISEER 7.5, Capacity » 70 ISEER 7.6 forSuper ECSBC Building) a)16 HP VRF ODU - 31.1 |
| 111 | b)12TR AHU Kit, Control kit with wired remote Controllers |
| 112 | Air Handling Units: Supply,installation,testing and commissioningof factorybuiltceilingMountedAirHandlingUnitin doubleskinconstructionoffollowingcapacityat required static pressure complete withfactory fabricated independent sections, The housing shall be so made that it can be delivered at site in total/semi-knockeddownconditionsdepending upon the requirements. The main framework shall beextruded aluminum structural sections with 50mm thick Thermo-acoustic panel.Thermo- acousticpanelshallbecomprisingof23+2mm thick thermal insulation PU foam injected between 0.6mmpre-coated GIouter sheet &plainGI intermediatesheet0.6mm,followedby insulation sandwiched between intermediate sheet and inner skinofperforatedGIsheet0.8mm. Theentire frameworkshallbeassembledusingmechanical jointsto makea sturdyand strongframeworkfor varioussections.Entire frameworkshall be made of extrudedaluminumprofile. Pre filter (MERV8) insupplyairstream.Replacementoffilters(pre filters)afterflushingoutperiodof15daysisinlcuded in the cost. AIIAHUwith 6 row deep a)4800CFM,12TRFMAHUWithVFD-Staticpressure 65mm WG |
| 113 | Refrigerant Piping Supply, Installation, testing andcommissioning includingvaccumiazationandNitrogentestingof following nominal sizes of soft/hard drawn copper refrigerantpipingforVRFsystem,completewith fittings,withsuitableadjustableringtypehanger supports, jointing/brazing includingaccessories like elbows, couplers, tee joints, \"U\" loops, expansion loops etc, supports consisting of GI box/ \"C\" sections & female anchor fastenerswith full threadedGIrods,insulatedwithXLPEClass-O tubularinsulation/with Class-Oclosed cell elastometric nitrile rubber tubular sleeves sections of19mmthickinsulationasgivenbelowfor Suction and Liquid lines, flushing, pressure testing and with all accessoriesas per specifications etc. as required a) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 114 | b) 28.58 mm dia (OD) (Hard drawn) with tubethickness 1.2 mm |
| 115 | Condensate drain pipe Supply,installation,testing and commissioningof condensatedrainUPVCpipingasperBIS4985 withnecessaryclamps,supports,hangersand fittingsuchasbend,tees,reducers etc.duly insulated with Nitrile insulation fire retardant gradeas per the drawing andspecifications 40mm dia with 6mm thick insulation |
| 116 | DUCTING & AIR DISTRIBUTION ITEMS Supplying, installation,balancingand commissioningoffactoryfabricatedGSSsheet metalrectangular/ roundductingcompletewith neoprene rubbergaskets, elbows, splitter dampers,vanes,hangers,supports,bends, transitions, reducers,endcaps,collarsetcas required complete in all respect in confirmationto IS : 655 and approved drawings and specifications of following sheet thickness complete as required a) Thickness 0.80 mm sheet |
| 117 | b) Thickness 0.63 mm sheet |
| 118 | Supplyingand fixingof dulylaminatedaluminium foil of mat finish closed cell Nitrite rubber (Class \"O\") insulation on duct after applying suitable low VOCadhesiveforNitrilerubber.Thejointsshall be sealed with 50 mm wide and 3 mm thick self- adhesivenitrile rubbertapeinsulation( From the Same OEM ofinsulation)complete as per specifications and as required. 9mm Thick Insulation (for Thermal insulation) |
| 119 | 10mm Thick Insulation (for Thermal insulation) |
| 120 | Return Air Diffusers Supplying, Fixing, installation, testingand commissioningofReturnairdiffusersofpowder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation toSMACNA/IS andasper specifications comete etc. as required |
| 121 | Flexible Connections Supply, fabrication, installation andtestingthe flexible duct connections constructed of fire resistanceflexible doublecanvassleeveasper the approved shop drawings. |
| 122 | Supplying,Fixing, installation,testing and commissioningof standard Hepa filter of dimension (HxWxD) 500x500x500 |
| 123 | Supplying,Fixing,installation, testing and commissioningof 7 mil/200 GSM glass cloth and 2 layers foster coat for protection from corrosion. |
| 124 | Supplying,installation, testingand commissioningof communication cable for wiring betweenAHU,AHU kit and Outdoor unit etc as required. |
| 125 | Supplying, Filling testing and commissioningsuitable Refrigerent Gas etc as required. |
| 126 | AnnualComprehensivemaintenanceof 1 No. VRF/VRV 12TR AC systemwhichincluderoutine,preventiveand breakdown maintenanceforperiodoffiveyearsincluding repair/replacementofwornoutitemsincluding minor components, leak arresting ,cleaning witha minimumdown time and warranty & guaranteeof repaired/replaceditemsaftercompletionofone year guaranteeperiod.(Rate quotedshall be per whole system/3month/visit)(Thisitem shall also be consideredfor evaluation of the lowest bidder) a) 1st Yearafter defect liability period |
| 127 | b) 2nd Year after defect liability period |
| 128 | c) 3rd Year after defect liability period |
| 129 | d) 4th Year after defect liability period |
| 130 | c) 5th Year after defect liability period |
| 131 | Add 34.54% towards cost index for HVAC |
| 132 | APPENDIX-C (Electrical Work) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS, PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 133 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm |
| 134 | 25 mm |
| 135 | Supplying and fixing of UPVC cable management system (wall trunking) of following nominal size on surface with all accessories including front covers, couplers, bends, end caps,separation partition for entire length, cable retainer for every unit metre length etc. as required. 100mm x 50mm /105mm x 50mm |
| 136 | Wiringforlight/powerplugwith 4x4sq.mmFRLSPVCinsulatedcopper conductorsinglecorecable insurface/recessedmediumclassPVCconduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 137 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ under floor trunking system /Cable management system as required. 3 x 4 sq. mm |
| 138 | 6 x 4 sq. mm |
| 139 | 9 x 4 sq. mm |
| 140 | 12 x 4 sq. mm |
| 141 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/ recessed medium class PVC conduit as required 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 142 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 143 | 4x 6 sq. mm + 2x 6 sq. mm earth wire |
| 144 | Supply and fixing following size/module, GI box along with moular base & cover plate for modular switches in surface/recess etc. as required. 3 Module (100mmX75mm) |
| 145 | 6 Module (200mmX75mm) |
| 146 | Supplying and fixing following modular switch/ socket on the existing DLP Trunking including connections but excluding modular plate etc. as required 15A Universal Switch with indicator |
| 147 | 15/16ASquare type Universal Socket Outlet (suitable for connecting square type plug top) |
| 148 | Supplying and fixing suitable sizeplate / cover in front on CMS including providing and fixing following data / Telephone socket outlet, connection, testing, commissioningetc. as required. telephone socket |
| 149 | Data socket outlet |
| 150 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCCB incomer distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs with provision of upto 100A 4Pole MCCB as Incomer interconnection between MCCB and busbar (but without MCBs and incomer MCCB ) as required . 8way, double door |
| 151 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (8 + 12), Double door |
| 152 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole |
| 153 | Triple pole |
| 154 | Supplyingand fixingTP sheetsteelenclosureon surface/recessalongwith 16/25/32A 415 volts \"C\" curve TP MCB complete with connections, testing and commissioning etc. as required. 32A |
| 155 | Supplying and fixing following rating, 4pole 415 V, Isolatorthe existing MCB DB complete with connections, testing and commissioning etc. as required 100A |
| 156 | Supplyingand fixingDP sheetsteelenclosureon surface/recessalongwith 16/25/32A 240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. 16A |
| 157 | Supplying and fixing following rating, four pole, MCCB,25KA, 415 volts in the existing MCB DB complete with connections, testing and commissioning etc as required. 100 A,25KA,4P MCCB |
| 158 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCBO) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc as required.63A RCBO |
| 159 | 80A RCBO |
| 160 | Supplyingand fixingTPN sheetsteelenclosureon surface/recessalongwith following TPN Isolator connections, testing and commissioning etc. as required. 100 A ,TPN Isolator |
| 161 | SITC of Indoor 2feet x2feet square type 30/36W LEDlighting luminaire of cool day light output andthe following specifications:Lumen output: Not less than 3300lm; Efficiency: 100 lumen/watt; Make: Philips / Wipro, Bajaj or Crompton, Havells |
| 162 | SITC of Indoor 2feet x2feet square type 30/36W LEDlighting luminaire of cool day light output andthe following specifications:Lumen output: Not less than 3300lm; Efficiency: 100 lumen/watt;Make: Philips / Wipro , Bajaj or Crompton ,Havells |
| 163 | Supplyingof XLPE insulated, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade conforming to IS: 7098 (Part-I) with up-to-date amendments of following sizes as required. 3.5 x 70Sq.mm |
| 164 | 3.5 x120 Sq.mm |
| 165 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 166 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 167 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizes in the existing masonry open duct as required. Above 35 upto 95 sq. mm |
| 168 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizes in the existing masonry open duct as required. Above 95 sq. mm and upto 185mmsq |
| 169 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 70 Sq.mm |
| 170 | 3.5 x 120 Sq.mm |
| 171 | Commissioning of cubicle type Panel suitable for 415V,3 phase, 4 wire 50 Hz AC supply system having required front surface area Approx and 300mm depth fabricated in compartmentalised design from CRCA Sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning and finishing complete with 7 tank /abrasive blasting process for powder coating in approved shade, having 250amps capacity TPN Aluminium bus bar of high conductivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 31MVA for 1 sec.,bottom base channel of section not less than 75mm X75mm X 5mm thick with following fabrication shall be done in transportable section.Entire panel shall have a common GI earth bar of size 32mm X 5mm at the rear with 2 nos. earth stud, solid connections for main bus bar to switch gears with required size of copper bus bars and control wiring with 1.5 sq.mm. FRLS PVC Insulated copper conductor single core cable, cable alleys, cable gland plates in half, MV danger notice board i/c providing following switch gears complete as required Incomer, a)250 Amps, 4P, 36 KA MCCB (Ics = 100% Icu) with thermal magnetic release for over current, short circuit Release, extended rotary handle etc 1 No. bus bar, 250 amps 4 strip Copper Bars of suitable size with a current density not more than 1.2A / Sqmm.The bus bars shall be sleeved with colour coded heat shrinkable PVC sleeves.The bus bars shall be supported at suitable intervals with SMC / FRP supports as per relevant standards, uotgoings, 3Nos ,160A FP25kAthermo-magnetic release type MCCB complete with operating handle, spreader links, phase barriersetc, 2Nos,100A FP25kA thermo-magnetic release type MCCB complete with operating handle, spreader links, phase barriers etc. Indication lamps ,Metering modules -1set each |
| 172 | Dismantling of all old wirings,DB,switch boards,etc and handed over the same in the department store including transportation etc as required |
| 173 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 174 | Providing and fixing ISI marked, PESO approved, Ce & EN certified ABC powder stored pressure type fire extinguisher of following capacity and rating confirming to IS: 15683 & IS: 4308 up to date amended, steel can having epoxy powder coated interior & epoxy polyester powder coated exterior, forged brass valve with in built pressure relief device, aluminium siphon tube & diffuser, stainless steel safety pin, high durable vinyl label, QR code label with printed serial number, pressure gauge, carrying handle, controllable discharge mechanism, 4m discharge range etc on wall surface using suitable mounting accessories complete as required. 4 kg, 4A 144B, MAP 90, 15 sec discharge time |
| 175 | Providing and fixing ISI marked, PESO approved, CE 7 CN certified CO2 gas type fire extinguisher of following capacity and rating confirming to IS: 15683 up to date amended with 99.7% pure CO2 gas, seamless extruded aluminium cylinder coated with high glossy PU paint, dual spindle valve with aluminium wheel & collar / squeeze grip brass valve, aluminium siphon tube, high durable vinyl label, QR code label with printed serial number, pressure gauge, carrying handle, controllable discharge mechanism etc. on wall surface using suitable mounting accessories complete as required. 4.5 kg, 55B, 13s discharge time |
| 176 | Add 34.54% Cost index for Electrical |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail