| 1 | B&R PORTION:M&L for Anti termite Treatment of soil under existing floors using chemical chlorpyrifos emulsifiable concentrate @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and directed. |
| 2 | M&L for Providing and injecting chemical chlorpyrifos emulsifiable concentrate for Post Constructional Anti termite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 3 | Dismantling of loose concrete cover of RCC slabs, chajjas, parapets, cupboard, beams/lintels and similar work, and the like as directed without disturbing the core of RCC member, roughening and cleaning concrete surfaces with steel wire brushes, washed with water and allowed to dry, including application of rust removal cum passivator painted with brush to the rusted reinforcement (and removing rust with flex after 24 hours of application of rust remover with the help of wire brush, sand paper) and also applying zinc anti-rust agent as per manufactures method of application to re bar corrosion protection system to reinforcement surface of steel reinforcement after that applying polymer modified Cementous bonding coat, prepared and applied on the concrete surface with 1 part of sika latex or equivalent in Forsoc/BASF/Dr Sunanda with 4 part of water and 6 part of cement by weight, coverage of sika latex shall not be more than 0.25 Kg/Sqm for one coat. Adhesive bond strength not less that 2.5 mpa, After this, providing 40mm (average thickness) guiniting mix @pressure 2.2 to 2.5 kg per sqcm with anti corrosion admixture (using 1 part of ordinary portland cement 43grade and 2part of Ghagger sand mixed with adhesive/admixture at the rate as per manufacturer instruction and as directed) including stripping floating with wooden strippers for proper dimension control necessary, formwork and scaffolding, complete surface of guiniting to be finished fair with 10mm thick plaster in Cement Mortar 1:4 with water proofing compound @ 3% by weight of cement cleaning and removing of waste material etc as directed at site complete all as specified and directed. |
| 4 | Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 5 | M&L for reinforced cement concrete (nominal mix) Type A1 of 1:1.5:3 (20mm graded crushed stone aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, floor, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr in charge. |
| 6 | S&F TMT bars 10 mm dia & over as in reinforcement of columns, beams, RCC, slabs, chajjas, lintels etc cut to length bent to shape required including cranking, bending, spirally hoping for columns, hooking ends and welding the new reinforcement with old steel bars complete all as specified and directed by Engr in charge. |
| 7 | S&F TMT bars 5 mmdia upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with with mild steel wire (annealed) not less than 0.9mm dia or securing with clips includingU-shaped stirrups with necessary welding required at site complete all as specified and directed by Engr-in-Charge. |
| 8 | Formwork to soffit of suspended slabs such as roof slabs, floor slabs, chajja, landings and similar work; not exceeding 200mm thick complete all as specified and directed. |
| 9 | Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. |
| 10 | M&L for mild steel 6 - 8mm dia TMT bars bent to shape required, including cranking,bending and binding with mild steel annealed wire not less than 0.9mm dia complete all as specified and directed. |
| 11 | M&L for providing PMM (Polymer modified cementitious mortar) :-(i) Dry sub strata surface and free of debris & dust(ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness.Note :Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairly rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer complete all as specified and directed. |
| 12 | M&L for polymer modified cement bonding coat, prepared and applied on the concrete/masonry surface with 1 part of Sika latex with 4 part of water and 6 part of cement by weight. Coverage Sika latex 0.25 kg/sqm for one coat at all heights levels Adhesive bond strength not less than 2.5 MPa. (Make - Sika/ BASE Fosroc/ Dr Sunanda) including chipping of the loose concrete all as directed by Engineer-in-Charge.. |
| 13 | M&L for Cement concrete 50mm thick type B-1, 1:2:4 (using 20mm graded stone aggregate) in floors, pavings etc finished even & fair with out using extra cement complete all as specified and directed. |
| 14 | M&L for Light coloured double charged vitrified ceramic tiles of sizein floors, 600 x 1200 mm set & jointed in neat cement slurry and pointed in coloured cement to match over & including 15mm thick screed bed in CM 1:4 including dismantling with removing serviceable material to store and rubbish off out of MOD land complete all as specified and directed. |
| 15 | All as per Item No 14.00 above but as in Skirting over and includinbg 10mm thick rendering in CM 1:3 complete all as specified and directed. |
| 16 | M&L for light coloured non skid matte finish ceramic tilesin floors, of size 600 x 600 mm set & jointed in neat cement slurry and pointed in coloured cement to match over & including 15mm thick screed bed in CM 1:4 including dismantling with removing serviceable material to store and rubbish off out of MOD land complete all as specified and directed. |
| 17 | M&L for 600x300 mm thickhigh gloss/super gloss ceramic tiles coloured as in dado/skirting and vertical surfaces set jointedin neat cement slurry and pointed in coloured cement over and incl10 mm thick cement mortar 1:4, Shade, pattern, laying etc of tiles as directed at site including dismantling with removing serviceable material to store and rubbish off out of MOD land complete all as specified and directed. |
| 18 | Demolition of stone slab and tiles of any description or thickness in floors, apron, laid, bedded and pointed in any mortar including dismantling with removing serviceable material to store and rubbish off out of MOD land complete all as specified and directed. |
| 19 | M&L for 16-18mm thick granite \"Jade black\" (table rubbed and polished) in steps, Jambs, pillar Window cill, cooking platforms, in single piece in cooking platform additional 75 mm width of same granite patti stick with araldite or equivalent adhesive full moulding of edges to match the colour granite, fixed with 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed Notes:- (a) Additional 75 mm width patti shall be measured separately. (b) Minimum rate of granite should not be less than Rs 150 per Sqft including GST |
| 20 | M&L for drilling holes for pipes etc n exc 25mm dia in cooking platform holes in granite complete all as specified and directed. |
| 21 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) for wall lining/vertical surfaces (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 22 | M&L for Udaipur green marble work 16 to 18mm thick (table rubbed and polished) in floor, steps, window cills, and like including including 20mm thick screed bed in CM 1:6 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shadeincluding rounded edges with shade of Udaipur green complete all as specified and directed by Engr in charge. |
| 23 | M&L for Udaipur green marble work 16 to 18mm thick (table rubbed and polished) in vertical surfaces like riser/skirting, jambs, pillars, and like and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shadeincluding rounded edges with shade of Udaipur green complete all as specified and directed. |
| 24 | S&F in repair Rotational moulded polythene water storage tanks, double layered (Cylindrical vertical with closed top) of capacity 1000 lit, hoisted and fixed in position complete all as specified and directed. |
| 25 | Taking up or down steel tubing and connections of 15mm bore complete all as specified and directed. |
| 26 | Taking up or down steel tubing and connections of 20mm bore complete all as specified and directed. |
| 27 | Taking up or down steel tubing and connections of 25mm bore complete all as specified and directed. |
| 28 | Supplying and laying of CPVC 20mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl brass coupling fittings complete all as specified complete with fitting as required complete all as specified and directed. |
| 29 | Supplying and laying of CPVC 25 mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl brass coupling fittings complete all as specified complete with fitting as required complete all as specified and directed. |
| 30 | Supplying and laying of CPVC 32 mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl brass coupling fittings complete all as specified complete with fitting as required complete all as specified and directed. |
| 31 | S&F in repair Ball brass valve, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to dia of pipe 20mm complete all as specified and directed. |
| 32 | S&F in repairs cPVC globe or gate valve with iron wheel head, 32 mm bore, screwed both ends for iron pipe complete all as specified and directed. |
| 33 | Taking downchowkhats or frames of any description n exc 1.5 sqm each (without taking off shutters from the frame) complete all as specified and directed. |
| 34 | Taking down chowkats or frame with shutters (without taking off shutters from the frames) but Exc 1.5 and n. Exc 4 Sqm each complete all as specified and directed. |
| 35 | Taking down shutters of any description exc 1.00 and n . Exc 2 Sqm each complete all as specified and directed. |
| 36 | S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkhat of size 65x 125 mmof double rebates comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and non toxic additives ( max toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed by Engr incharge. Note: For WPC solid door/windows frames, minus 5mm tolerance in dimension i.e. depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. |
| 37 | S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkhat of size 50x100 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and non toxic additives ( max toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: For WPC solid door/windows frames, minus 5mm tolerance in dimension i.e. depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. |
| 38 | M&L for Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed by Engineering- Charge. Note: stainless steel butt hinges shall be paid separately under relevant item of sch |
| 39 | M&L for Providing 30mm thick FACTORY-MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of Density 650 Kg /cum Manufactured by an ISO-9001-2015 certified Company, Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (Confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through Other hardware should be fixed with 19*6mm size steel screws etc as per manufacturer\"s specification & drawings complete all as specified and directed.Note: Fixture/fittings shall be measured & paid under relevant item |
| 40 | M&L for MS flat iron as in hold fast, bands,straps, supports or stays for rain water, ventilating pipes, including bolts, if required hook (stay), heavy, for large gates;hook and pintle hinges large hasps andstaples; chains, hand madesliding bolts; clamps; hold fasts; wall ties, hooks for hangingfans; plainangle cleats forsecsuring purlins to wood trusses orrafters; knee piece inserts; twoway and three way straps, plate washers and similar small articles conforming to Fe-290Gde-E-165 complete all as specified and directed. |
| 41 | M&L for PCC 1:2:4 type B-1 (20mm graded agg) as in anchorging hold fast, windows cills, jambs and similar work etc bed plate etc complete all as specified and directed. |
| 42 | S&F Stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed. |
| 43 | S&F factory made uPVC brown colour Three track jointless three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.comprising of uPVC multi- chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and incl provn of guard bars of 10 mm square MS bar as safety grill, necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, incl all required hardware fitments complete all as specified and directed by Engineer-in-Charge. Rate of Glass or wiremesh shall not be paid separately rate is included in the quoted rate and no seperate payment will be given for glass and wiremesh) (Rate of 10 mm square MS bar will be included in the quoted rate and no seperate payment will be given for guard bar) complete all as specified and directed.Make : Rajshri / Fenesta / EcocellNote: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 44 | S&F Aluminium powder coated/UPVC coloured decorative grill with 6.3mm thick upvc section and 100X100mm openings, weighing not less than 1.75Kg/Sqm and anodized upvc \"U\" shape channelframe work allaround the grill incl necessary fixing arrangements with Aluminium/UPVC window upto G+1 building if required opening for handle or AC as complete all as specified and directed by Engr in Charge. |
| 45 | S&F uPVC ventilator with exhaust fan, for ventilation in toilet with (openable type window / Fixed glass as per requirement) of frosted glass with uPVC frame of approved colour, thickness 60 mm, Length 750mm and height 600 mm complete all as specified and directed. |
| 46 | S&F 125mm long (size) butthinges, stainless steel AISI 304 grade with brass/bronze hinge pin complete all as specified and directed. |
| 47 | S&F 100mm long (size) butthinges, stainless steel AISI 304 grade with brass/bronze hinge pin complete all as specified and directed. |
| 48 | S&F stainless steelAISI 304 grade barrel tower bolt 200mm long, extruded section, etc. complete all as specified and directed. |
| 49 | S&F stainless steelAISI 304 grade barrel tower bolt100mm long, extruded section, etc. complete all as specified and directed. |
| 50 | S&F Magic eye and fixed to doors complete all as specified and directed. |
| 51 | S&F stainless steel drapery curtain rods gold or antique silver 25mm nominal dia and minimum wall thickness 1.20mm of SS-304 grade of approved brackets design as approved fixed in brick/ concrete wall with same finished knobs/latto on each end of curtain rod including taking down old pelmet, complete all as specified and directed. |
| 52 | S&F 300mm long, stainless steel , sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, and fixing bolts andsliding bolts and fixed, complete all as specified and directed. |
| 53 | S&F 150mm size stainless steel AISI 304 grade fancy type handle complete all as specified and directed. |
| 54 | S&F 100mm size stainless steel AISI 304 grade fancy type handle complete all as specified and directed. |
| 55 | S&F SS Premium night latch with suitable stainless steel chain of size 250 to 300mm long including plate and fixed complete all as specified. Make: Godrej Cat Part No 7666 or equivalent of make as specified in PS. |
| 56 | S&F heavy duty door magnet stopper is constructed of high quality virgin plastic, solid, sturdy and rust-Prooffor hold and clatch fixing to back side of door shutter including all fixing items complete all as specified and directed by Engr in charge. |
| 57 | S&F 4.00 mmthick figured glass, pin head type andglazing with wooden beads, glass putty, PVC beading, aluminium beads, complete all as specified and directed. |
| 58 | S&F 18 mm thickHDHMR board pre laminated both side (of approved colour) having density more than 850 kg/cum, fixed with screws as in wall panel, storage cabinet/Cub board and built in modular tables etc, for hold of shelf / partition and shall provide 3 edges in sizes 18 mm x 18 mm as per required length.theedgesof shelf / partation / wall side to be lipped with including 18 mm x 1 mm thick laminated sheet of density 850 kg/cum manufactured by as ISO -9000 certified company , lipping portion should be match with laminated colour, using solvent cement etc. (including all necessary brass hardware fitting i.e Piano hinge ,handle, ball catchers including mortice locking arrangement, hole cap including lipping etc, and siliding rail in each Cup board complete all as specified and directed. |
| 59 | S&F stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make - Hettich/Haffele or equivalent in others to cupboard shutters of kitchen cabinets with full threaded steel screws including making necessary recess in board and finished etc complete all as specified and directed by Engineer-in-charge. |
| 60 | S&F Kitchen cabinets made out of 18 mm thick HDHMR board pre laminated both side (of approved colour) having density more than 850 kg/cum including making drawers, partitions, shelves and HDHMR board on all sides with following specifications complete all as specified and directed by Engineer-in-charge:-(a) 18 mm thick HDHMR solid flush board with one side pre-laminated sheet fixed on one side, as kitchen cabinet (incl dismantling of existing board).(b) Frame of size 50mmx47mm. (c) Shutters having brass piano hinges and brass handle 75mm long No for each shutter.(d) Bottom back and sides of cabinet covered with 18 mm thick HDHMR board with one side pre-laminated sheet fixed on one side. (e) Drawers having brass handle 75mm long and two long sliding rails for each drawers with brass magnatic catcher as required.(f) Cabinet must have one drawers supported of sliding rails. (g) Size of each cabinet shall not be exceeding 0.9 M x 0.75 M and 0.60 M depth.(h) Measurement will be considered only for front face i.e. length & height and corner box portion without front face will also be included in L-shape platform bottom.(j) SS jali racks mounted on drawer chanel Note: Measurement for purpose of payment shall be made on external visible face for width x height (considering frame). |
| 61 | M&L for Cutting shrubs, wild growth, plants not exc 30 cm girth grown on permanent structures and removingsame from roots and stopping the recurrence by injecting herbicide Glyphosate 4+solution (04 % concentrate) into plant root to eliminate further growth. Application shall be as per manufacturer instructions. The disturbed area shall be repaired with PCC (1:2:4) Type B0 mix and surface finished even and smooth in cm 1:4 incl applying two coats of matching finish of adjacent area (Minimum plant in each block is 10 Numbers) complete all as specified and directed. |
| 62 | M&L for 2nd class hard wood, plain fillets square, rectangular or triangular in section exc 13 & n.exc 25 sqcm in section , wrought, secured including taking down with nails complete all as specified and directed. |
| 63 | Dismantling wrought iron or mild steel work of any description not other wise described complete all as specified and directed. |
| 64 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of stair case/ waist slab with suitable arrangement complete all as specified and directed by Engr in Charge. |
| 65 | S&F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed. |
| 66 | Taking down cement plaster on brick Walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 67 | M&L for prepration of brick or concrete surface clean and free of dust,oil,paint,loose particals,dimoldimg agents,organic products etc and applying 15mm thick exterior surface treatement as in 2 layer [10mm base layer and 5mm final layer] complete all as specified and directed as under:-(a) base coat [10mm thick]: Apply in 1 or more coat to achieve average 10mm thick of water vapour permeable mortar,unofin classic base coats render or equivalent brand of make sikka,fosroc for weather resistant and high performance facades with csiv commpressive strength,flexural strength > 2.5 N/mm2 and water vapour permibility < 15micron as per EN 998-1 and finished even and rough marks to anchore with final layer it should be includes the rain forcement of weaker points / areas [change in the subtract material, slab, pillars/ rollar blind boxes around the opening/windows,doors etc] with fibre glass mess to avoide cracks as per manufacturers recomndation or as per direction of engr-in-charge.(b) Final layer [10mm thick]: Finishing with rainwater resistantand water vapour permeablerendring mortar,UNOFIN PRIME COARSE render or equivalent brand of make sikka,fosroc for weather resistant and decorative facades with CSII commpressive strength,flexural strength > 2.5 N/mm2 and water absoptionas W2 (C<0.2Kg/m2.min 0.5) water vapour permibility < 15micron as per EN 998-1 all as per manufacturers recomndation or as per direction of engr-in-charge.Note: 1. Size and specification of fibreglass mesh shall be as per manufacturersrecommendations. 2. Contractor shall be provide authorised applicatore and no exter cost shall be provide in this account. |
| 68 | M&L for rendering 15 mm thick in cement mortar 1:6on conc/brick surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 69 | M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces, rendering finished even and smooth (without using extra cement) mixed with WPC @200 ml/Bag of cement complete all as specified and directed.Note: WPC shall be measured and paid seperately. |
| 70 | M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as on ceiling and finished fair and even complete all as specified and directed by Engr in charge. |
| 71 | Supply only liquid water proofing compound as per manufacture instruction complete all as specified and directed. |
| 72 | M&L for preparation of new plastered wall surfacesand applying two coats of distemper oil emulsion, white or tinted over one coat of primer including 3mm thick wall care putty complete all as specified and directed. |
| 73 | M&L for preparation of old distempered surfaces of wall by complete removal of existing treatment from wall surfaces and applying two coats of distemper oil emulsion, white or tinted over one coat of alkali-resistant primer paint and 3mm thick wall care putty complete all as specified and directed. |
| 74 | M&L for preparation of new ceiling surfaces and applyingtwo of distemper oil emulsion, white or tinted over a coat of primer paint compete complete all as specified and directed. |
| 75 | M&L for preparation of old distempered surfaces by complete removal of existing treatment from ceiling surfaces and applyingtwo of distemper oil emulsion, white or tinted over a coat of primer paint complete all as specified and directed. |
| 76 | M&L for two coat of super quality weather proof exterior emulsion paint over & includingone coat of primer from the same manufacturer onexternal walls / ceiling surfaces including a coat of wall care putty to achieve smooth surface including preparation of new surface complete all as specified and directed. |
| 77 | M&L for complete removing and apply two coat of super quality weather proof exterior emulsion paint over & includingone coat of primer from the same manufacturer onexternal walls / ceiling surfaces including a coat of wall care putty to achieve smooth surface including preparation of OLD surface complete all as specified and directed. |
| 78 | M&L preparation of new wooden or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying tow coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 79 | M&L for preparation of new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 80 | M&L for preparation of old wooden surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint white or tinted complete all as specified and directed. |
| 81 | M&L for preparation of old painted steel surface of any description , over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint white or tinted complete all as specified and directed. |
| 82 | S&F in repairs 600 x 450 x 4 mm thick looking mirror bevelled edge of selected quality glass, mounted on 4mm thick commercial ply or AC building board fitted to wooden plug with CP brass screws complete all as specified and directed. |
| 83 | S&F Glass Shelf assembly Sheet consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. |
| 84 | S&F corner shelf (set of 03) 200mm to 300mm size5mm thick toughened glass complete all as specified and directed.Make: Paryag Cat Part No BEA 48 or equivalent of make as specified in PS and CA. |
| 85 | S&F in repairs vitreous china wash hand basin counter/table top type of size 495mmX395mmx150mm (Jaquar CAT Part No JDS-WHT-25909, Cera CAT Part No S2020163 or Equivelant in Kohler) in 18 mm thick granite (of any type) machine cut as in platforms, bedded andjointed with grey cement slurry and pointed with white cement with admixture of of pigment to match the shade of granite stone, including32mm bore dia CP waste coupling, bottle trap (Jaguar CAT Part No ALD-SSF-769L250X190, CERA Cat Part No F8060301 or equivalent) and all required fittings complete all as specified and directed. |
| 86 | S&F in repair 15mm bore dia Stainless steel finish quarter turn central hole basin mixer round spout with popup Waste assemlywith 10mm dia, 450 mm long copper pipes complete all as specified and directed.Make: Jaquar CAT Part No CQT-CHR-23167B, Cera Cat Part No F2002461 or Equivelant in kohler |
| 87 | S&F in repair Brass chromium plated tubular towel rail, 20mm dia and 600mm long with brackets fixed complete with brass chromium plated screws complete all as specified and directed. |
| 88 | S&F in repair 0.63 mm thick kitchen plate rack made of stainless steel 750 x 600 x 250 mm size fixing with wooden plug with suitable size of screws complete all as specified and directed. |
| 89 | S&F in repair chromium plated 3 in 1 concealed single lever shower mixer,Shower System, 300mm Shower with arm, hand shower 1m to 1.2m connection and one spoutwith 10 layersurface finished,Shower System owns a modern and stylish look, Excellent plating technology prevents the coating from falling off, after a long time use still keep the surface smooth and clean will all connected items all as specified by manufacture complete all as specified and directed. Make Jaquar, Hindware & Cera |
| 90 | S&F in repairs Kitchen sinkmixer 15mm dia CP brass fancy type including joints to steel pipe or unions complete all as specified and directed by Engr in charge.Make Jaquar Cat Part No ARI39309, Kohler Cat Part No 20591 IN-CP, CERA Cat Part No F1015501 |
| 91 | S&F in repair chromium plated brass bib tap fancy type screwed down, screwed for iron pipe or for brass ferrule 15 mm bore complete all a specified and directed. Make- Jaquar CAT Part No CON-CHR-041KN, Cera Cat Part No F2002163 or Equivelant in kohler |
| 92 | S&F in repairs sinks with drainage boards made of stainless steel lmmthickkitchenorlaboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 93 | S&F in repair angle valve (one way) 15 mm bore cast copper alloy fancy type, cromium plated with cupcomplete all a specified and directed. Make- Jaquar CAT Part No OPP-CHR-15053PM , Cera Cat Part No F2002201 or Equivelant in kohler |
| 94 | S&F in repair Towel ring of PTMT fixed with and incl. CP brass screws AND wooden/plastic cleats {min. weight 90gms} complete all as specified and directed. |
| 95 | S&F in repair Brass chromium plated toilet paper holder, fixed to wall with CP brass screws complete all as specified and directed. |
| 96 | S&F 15 mm bore chromium plated nozzle for RO connection complete all as specified and directed. |
| 97 | S&F in repairvitreous China wash down water closet (Pedestal pattern) white complete including provision of lime concrete bedding, valveless symphonicaction type PVC low level double action flushing cistern (small single flush 2-3 ltrs and large single flush 7-9 ltrs output) with inlet ball valve float & handle incl. brackets of 10 ltrs capacity complete with plastic water closet seat white closed pattern with flat bottom & cover & mild steel chromium plated or aluminium hinges device & flush pipe of polythene of low or high density of PVC 32mm dia for low level PVC cistern complete all as specified and directed.Make: HINDWARE/ JAQUAR/ CERA (Ist quality) |
| 98 | S&F brass chromium plated Health Faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tupe and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 99 | S&F in repar PVCconnection 15mm dia 600mm long with PTMT nut complete all as specified and directed. |
| 100 | Dismantling of floor of size approx area (0.96+1.61)=2.57 sqm for EWC/IWC water closetand removing out the cinder/concrete from sunken portion, , grinding any sharp edges etc complete all as specified and directed with following: (a) Cleaning of RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite.(c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Pastorate plus as specified.(d) M&L for providing 40 mm dia GI pipe spout projecting at least 150 mm beyond outer face of wall.(e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(f) The area of Each WC portion is n.exc 4.00Sqm each.(g) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.(h) 72 hrs Ponding test shall be carried out for sunken treatment before payment. |
| 101 | Dismantling of cast iron pipe of any dia (soil/waste/vent) with fittings etc fixed to walls, ceiling, on floors & from trenches if requiredincluding taking out any type of joints complete all as specified and directed. |
| 102 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives, laid in trenches or in floors etc of 75 mm dia complete all as specified and directed. |
| 103 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls with brackets etc of 75 mm dia complete all as specified and directed. |
| 104 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives, laid in trenches or in floors etc of 110 mm dia complete all as specified and directed. |
| 105 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls with brackets etc of 110 mm dia complete all as specified and directed. |
| 106 | S&F PVC (SWR) bends/shoes any radius of 110mm dia complete all as specified and directed. |
| 107 | S&F PVC (SWR) Tee any radius provided with access door of 110mm dia complete all as specified and directed. |
| 108 | S&F PVC (SWR) bends any radius provided with access door of 75 mm dia complete all as specified and directed. |
| 109 | S&F PVC (SWR) Tee any radius provided with access door of 75 mm dia complete all as specified and directed. |
| 110 | S&F 75 mm in repair bore PVC floor trap with 75mm dia grating including jointing to waste pipe, complete all as specified and directed. |
| 111 | S&F in repair for salt glazed stone water gully traps size 150 x150mm square type \"P\" including setting and jointing to drains with CM 1:1 and CI grating complete all as specified and directed. |
| 112 | Demolition of cement concrete unreinforced in floors , roof and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 113 | M&L for Brick work with sub class \"B\" bricks , straight or curved on, wall, drain, manhole etc plan exc 6 m mean radius built in cement mortar (1:6),(up to two story Bldg) including demolition of old brickwork complete all as specified and directed. |
| 114 | M&L for Brick work with sub class \"B\" bricks , straight or curved on in half brick thick wallbuilt in cement mortar (1:4),(up to two story bldgs) complete all as specified and directed.Note for above items:(a) All work shall be done using mechanical scrapper and using roller brush through authorised applicator only. (b) Authorised applicator of paint manufactures shall have valid authorisation letter from the manufacturer (minimum regional HQs) issued not earlier than 30 days days from start date of the said work.(c) The contractor shall provide application, testing and certification of finishes by paint manufacturing firms/their authorised applicators.(d) Cost of above mentioned shall also included in quoted rates (e) All work mentioned above shall be done for three storied bldg. |
| 115 | E&M PORTION:Taking down carefully old point wiring with aluminium/ copper conductor (Light / Fan/ Socket/ power Point ) complete including fittings such as ceiling rose, pendent holders, regulators and socket point etc and making good the disturbed surface & wall/ floor complete all as specified and directed by Engr in charge. |
| 116 | M&L for point wiringwith PVC insulated unsheathedmulti strandedFRLS type copper conductor cable of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly in and including PVC concealed conduit 20 mm dia medium grade ISI marked andits accessories including provn of new factory made pressed steel modular switch/terminal box of suitable size and new modular front & back plates of approved colour/model of suitable size for housing the modular switches, sockets, fan regulators for one light/ fan/ exhaust fan point controlled by one no, one way 5 Amp switch complete all as specified and directed.Note: (i)Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate.(ii)No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or surface new conduit shall be provided as required.(iii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion. |
| 117 | All as per item No 116.00 above but for One light point controlled by two way 5 Amp switches complete all as specified and directed. |
| 118 | All as per item No 116.00 above but for One bell/buzzer point controlled by one bell push complete all as specified and directed. |
| 119 | All as per item No 116.00 above but for One three pin 5 Amp socket outlet point controlled by one no, oneway switch on same board complete all as specified and directed. |
| 120 | All as per item No 116.00 above but for One three pin 5 Amp socket outlet point controlled by one no, one way switch on independent board complete all as specified and directed. |
| 121 | All as per item No 116.00 above but with 2.5 sqmm (for phase, neutral) and 2.5 sqmm (for continuous earth wire) cable for one 15/16 Amp socket outlet point on independent board complete all as specified and directed. |
| 122 | S&F in replacement of modular Switch 6 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and directedMake: Legrand CAT Part No.573400, Havells (Murano) CAT Part No. ACUSXXW101, Schneider cat part No -X1101WH |
| 123 | S&F in replacement of modular switch single pole, two way6 amps, 230 Volts (ISI marked) complete all as specified and directed.Make :Legrand CAT Part No.573402, Havells (Murano) CAT Part No. ACMSXXW062, Schneider cat part No- X1002WH |
| 124 | S&F in replacement of modular bell push 6 amps complete all as specified and directed.Make : Havells (Murano) Cat part No-ACUSBXW101, Legrand Cat Part No-673404, Indoasian Cat part No-810615 |
| 125 | S&F in replacement of 16 Amp rating modular switch one way one module complete all as specified and directed.Make: Legrand CAT Part No. 573410, Havells CAT Part No. ACUSXXW161, Schneider Cat Part No -X1101WH |
| 126 | S&F in replacement of modular socket out let 230 volts grade (as catered in point wiring above) 6 Amp - 2/3 pin combined 2 module complete all as specified and directed.Make: Legrand CAT Part No. 573470, Havells CAT Part No. ACUKXXW063, Schneider Cat Part No -X2005WH |
| 127 | S&F in replacement of modular socket out let230 volts grade (as catered in point wiring above) 16 Amp - 2/3 pin combined 2 module complete all as specified and directed.Make: Legrand CAT Part No.573471, Havells CAT Part No. ACUKCXW163, Schneider Cat Part No -X2106WH |
| 128 | S&F in repair Call bell ding dong AC 230 volt single pole complete all as specified and directed.Make: Havells Cat Part No AHLLXXR000 or equivalent of make in Legrand/ Schneider. |
| 129 | S&F in repair Modular MCB SP 16Amps 240V 3 KA, C Curve,fitted in main switch board, including 2.5 sqmm wire connecting power socket & modular MCB complete all as secified and directed by Engr-In-Charge. Make: Havells Cat Part No DHFNCSPA016, LK (L&T) Cat Part No CB93101KW16, Schneider Cat Part No P8016-N. |
| 130 | S&F in replacement of factory made SPNDB\"s double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coatedsurface mounting12 way SPN 220 Volts,with suitable busbar, neutral link & earth link suitable for complete all as specified and directed.Make : Legrand Cat Part No 507612, L&T Cat Part No BH112DDB, Schneider Cat Part No A9HSND12. |
| 131 | S&F in replacment MCB, SP 6 to 32 Amp, 10 KA rupturing capacity, IS-8828 marked, and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note : Make of the MCB should be the same as that of DB |
| 132 | All as per item No 131.00 above but MCB DP 40 Amps complete all as specified and directed. |
| 133 | S&F in repair RCCB double pole 32 Amps,sensitivity 30 mA, for earth leakageand shock protection complete all as specified and directed by Engr-in-Charge. Note: Make of RCCB will be same as that of DB. |
| 134 | S&F in replacement of LED Tube light of 20 watt 230 volt (approx size 4 ft) box type complete with LED tube light 20 watt & all accessories internally prewired including connecting up with three core sheathed flexible copper conductor cable of suitable size having min P.F>0.95, minimum efficacy 120 lumen/watt IP 20 rating complete all as specified and directed.Make: Bajaj cat Part No BAJAJ BCLAB 20W CW LED XT, Crompton cat part No CCS-100-20-65-HL2-OP-NWH, Philips cat part No BN308C LED20S-6500 L120 PSU WH |
| 135 | S&F in replacement of LED Tube light fitting 10 watt (approx size 2 ft ) white230 Volt AC completeincluding connecting up with three core twisted flexible copper conductor cable having min P.F >0.95, minimum efficacy-100 lumen/watt, IP 20 rating complete all as specified and directed.Make : Bajaj/Crompton/Philips |
| 136 | S&F in replacement of remote controlled BLDC ceiling fan 1400 mm sweep, with remote, having minimum CMM 260, operating at 230 volts, 50Hz, having full copper motor & powder coated ribbed aluminium blades for higher air delivery, longer life complete with all the accessories including making arrangements to hanging of fan to ceiling with proper hook, nut,bolts & remote stand complete all as specified and directed. Make :Atomberg Efficio model No EFC21435RM or equivalent in Havells,Crompton, Bajaj, Orient. NOTE : Old ceiling fanwith all its accessories will be deposited to MES store yard in safe custody to process the BER board. |
| 137 | S&F additional remote controlled BLDC ceiling fan 1400 mm sweep, with remote, having minimum CMM 260, operating at 230 volts, 50Hz, having full copper motor & powder coated ribbed aluminium blades for higher air delivery, longer life complete with all the accessories including making arrangements to hanging of fan to ceiling with proper hook, nut,bolts & remote stand complete all as specified and directed.Make :Atomberg Efficio model No EFC21435RM or equivalent in Havells,Crompton, Bajaj, Orient. |
| 138 | M&L in replacement for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25X4 mm bolted (with GI nuts, bolts & check nuts) and rivetedto earth (Plate) electrode at one end and connected to main switch boardtest point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover etc complete all as specified and directed by Engr in charge. |
| 139 | S&F and laying in replacement of XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engineer-in-Charge. Note:- Earth work incl excavation, returning filling, sand cushioning and removal if required or suggested by user and Engr-in-charge/fixing into wall or terrace or any type of surface by using suitable clamps shall be included in the quoted rate. |
| 140 | S&F Exhaust fan AC single phase 230/240 v of size 300 mm, minimum CMH-1600 metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including hole making, Louver complete all as specified and directedby Engineer-in-Charge. Make:- Havells- VENTILAIR DB , Bajaj- MAX AIR, Crompton-TRANS AIR. |
| 141 | S&F Exhaust fan AC single phase 230/240 v of size 250 mm, with minimum CMH- 800 Engineering thermoplastic body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including hole making, Louver complete all as specified and directedby Engineer-in-Charge.Make: Havells Ventilair DX , Crompton Brisk Air Neo, Bajaj - Maxima DXL |
| 142 | S&F electric water heater ofcapacity 25 litre, BEE 5 Star rated heating element upto 2 KWwith glass lineinner tank with whirlflow technology , Mg anode rod, IPX4 high strength polymer body complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.Note:-1. The contractor needs to submit manufacturing warranty of geyser of minium two years to Engr-in-charge.Make:- Bajaj Armour series Pentacle , Havells Adonia Spin, Crompton Solarium CARE. |
| 143 | S&F in repair ceiling rose 3 phase / PVC/polycarbonated, isolated body ISI Marked complete all as specified and directed. |
| 144 | S&F inverter LED security light luminaire 60 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDshaving optical grade polycarbonate lens with 4 hours battery back up all accessories internally pre wired and including connecting up with two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of lightwith GI bracket of suitable size and clamps with fixing accessories complete all as specified and directed.Make: Philips /Crompton /Bajaj |
| 145 | S&F in replacement aesthetically designed Wall mounteddecorative wallLED light of 15 Wfixture with opal diffuser to give glare free light including suitable LED lamp of 15 W, complete all as specified and directed.Make: PhilipsCAT Part No. Muziris 31434, LustreCAT Part No. Li 3618/IW, WiproCAT Part No.BW06 |
| 146 | S&F in repair submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLSH type 1100V grade 2 x 6sqmm completedrawn in new PVC concealed conduit of 25 mm diaand its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi strandedFRLSH type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and directed.Make- Polycab, Havells, RR KABEL |
| 147 | S&F in replacement of aesthetically designed decorative warm white LED mirror light of07 W CCT-3000K fixture with bronze finish for superior feel including suitable LED lamp of 07 W having LED Lamp base complete all as specified and as directed. Make : Philips Model No 31402, Murphy Cat Part No MLDL 3 in 1 Mirror WOOD 12W-02, FILLISKA-1239. |
| 148 | S&F submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLSH type 1100V grade 2 x 4sqmm completedrawn in new PVC concealed conduit of 25 mm dia and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor multi strandedFRLSH type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and directed.Make- Polycab, Finolex, RR KABEL |
| 149 | S&F in replacement of wall mountedLED light bulkhead type 6-7 Watt, complete all as specified and directed. Make: Philips cat part No WT140W LED7S CW PSU S1 PC or equivalent in Crompton,Bajaj. |
| 150 | S&F in replacement of factory made VTPNDB\"s double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way VTPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TPN as incomer & MCB SP/SPNas out going complete all as specified and directed.Note:- Cost of MCCB 4 pole 63 Amp , breaking capacity 16 KA is included in unit rate quoted by contractor. Make: Schneider/Legrand/L&TNote: (a) Srl Item No 14.00, 17.00, 19.00, 22.00, 23.00, 36.00 to 39.00, 43.00, 44.00, 58.00 to 60.00, 67.00 to 72.00, 76.00, 85.00, 89.00, 92.00, 97.00, 116.00, 122.00, 130.00, 136.00, 137.00, 140.00 to 142.00, 145.00, 148.00 & 150.00 of BOQ and all bathroom fittings and sanitary items are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail