| 1 | Taking down cementplaster including racking out joints, hacking for key, scrubing down with water etc, complete all as directed. |
| 2 | M & L for rendering 15 mm thick in cement Mortar (1:4) on the external surfacesfair faces of brick work/concrete and finished the surface even and smooth using water proofing compound (wpc) as per manufacturer instruction complete all as specified and directed. |
| 3 | M & L for rendering 5 mm thick in cement Mortar (1:3) on the surfacesof ceiliing/ chajjas and all concrete surfaces exposed to view using water proofing compound (wpc) as per manufacturer instruction and finished the surface fair and even complete all as specified and directed. |
| 4 | M&L for preparation of old surface by brooming down or steel wire brushing, scrapping down smoke soot, moulds moss and efflorescent salts and trading oil and greasy spots and also to remove all loose scale of lime/colour wash, including removing nails making good holes, cracks patches only and applying two coat of white wash (lime) on walls including cornices plastered or un-plastered old decorated surface complete all as specified and directed by Engineer-in-charge. |
| 5 | M &L for preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of primar complete all as specified and directed. |
| 6 | M&L for preparation of old decorated surface of wall/ ceiling rubbing,watering etc and applying one coat of cement base paint complete all as specified anddirected.. |
| 7 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified & directed. |
| 8 | M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls excludingclamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. |
| 9 | S & F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays of 75mm borer of pipe Including bolts and nuts and securing ends of stays to wall or roof, complete all as specified & directed. |
| 10 | S & F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays of 100mm borer of pipe Including bolts and nuts and securing ends of stays to wall or roof, complete all as specified & directed. |
| 11 | M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints,laid in trenches or in floors or wall complete all as specified & directed. |
| 12 | M&L PVC (SWR) bend /reducer any radius 110mm dia complete all as specified & directed. |
| 13 | M&L PVC (SWR) bend / reducer any radius 75mm dia complete all as specified & directed. |
| 14 | M&L PVC(SWR) Tee any radius 110mm dia complete all as specified & directed. |
| 15 | M&L PVC(SWR) Tee any radius 75mm dia complete all as specified & directed. |
| 16 | M&L PVC(SWR) Vent cowl 110mm dia complete all as specified and directed. |
| 17 | S&F 75mm dia bore branch piece, single (equal or unequal) , ordinary or inverted, spigot or socket type or with parallel branches complete all as specified and directed. |
| 18 | S&F 100mm dia bore branch piece, single (equal or unequal) , ordinary or inverted, spigot or socket type or with parallel branches complete all as specified and directed. |
| 19 | Taking up or down steel tubing and connection of 15 dia bore. complete all as specified and directed. |
| 20 | Taking up or down steel tubing and connection of 20 dia bore. complete all as specified and directed. |
| 21 | Cutting chases in brickwall pinning in making good to facings where required and pointing in cement mortar 1:3 to ends and cutting chases for concealed water tubing and making good cutting n.exc. 10 cm girth. complete all as specified and directed. |
| 22 | S&F 15mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed. |
| 23 | Refixing old steel tubing and connections in new or old position 15mm dia complete all as specified and directed. |
| 24 | S&F 20mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed. |
| 25 | Refixing old steel tubing and connections in new or old position 20mm dia complete all as specified and directed. |
| 26 | S&F in repair Angle valve / stop valve , cast copper alloy fancy type chromium plated with long shankandcup screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15mm bore. complete all as specified and directed. |
| 27 | Dismantalling of existing water tanks and removinging to store and S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed. complete all as specified and directed. |
| 28 | Dismantalling of existing water tanks and removinging to store and S&F 500 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed. complete all as specified and directed. |
| 29 | M&L for preparation old painted surface of steel and iron work(of any description) over 10mm width or girth not other wise described and applying one coats coat of synthetic enamel paint all as specified and directed. |
| 30 | Removing all existing old treatment over RCC roof or Taking down cementplaster including racking out joints, hacking for key, scrubing down with water etc. complete all as specified and directed. |
| 31 | M&L for brushing net cement slurry @ 3 Kg / Sqm on roof slab complete all as specified and directed. |
| 32 | M & L for 15mm thick plaster fair finished using cement mortar 1:4 with WPC (as per manufacturer instruction) on roof slab complete all as specified and directed. |
| 33 | M & L for oil based bitumen primer @ 0.3 L/Sqm on plaster surface complete all as specified and directed. |
| 34 | M & L for APP membrane 3mm th min wt 3kg/Sqm for water prooping of roof sealing with 100mm over lap complete all as specified and directed. |
| 35 | Supply only integral water proofing compound. |
| 36 | Complete removal of all existing roof treatment from RCC roof including old hussion felt & preparation of surface with wire brush and cleaning with water complete and M&L for water proofing treatement on non approachable/on accessible roof surface horizontal and vertical surfaces in following sequence through manufacturer/aurhorized applicator of the manufacturer complete all as specified and directed:-(a) Brushing neat cement slurry @ 3Kg per Sqm on roof slab.(b) 15mm thick cement plaster fair finished using cement mortar(1:4) with WPC on roof slab.(c) Applying oil based bitumen primer @0.30 ltr/Sqm on plastered surface.(d) Applying modified APP polymeric membrane 3mm thick and minium weight 3.00 Kg/Sqm for water profing roof , sealing as directed at site with 100mm over laps as per manufacture\"s instruction.Note \" Supply only WPC shall be measured and paid separetly under relevant item.(e) Applying two coats of Aluminium paint over bituminous surface of membrance |
| 37 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |