| 1 | B & R Division Items |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed. |
| 3 | Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but exluding ashlars facings, dressed stone work and pre-cast concrete articles all as directed. |
| 4 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 5 | Dismantling of asbestos cement (corrugated, semi-corrugated, etc) sheets in roof covering complete all as specified and dircted. |
| 6 | Dismantling of wall and ceiling boards (fibre, pulp, insulation boards etc) any thickness including cover fillets complete all as specified and directed. |
| 7 | Dismantling of timber boarding of any description fixed in any position with nails complete all as specified and directed. |
| 8 | Dismantlig timber scantling in any position unframed work 40sqcm and over in section complete all as specified & directed. |
| 9 | Taking down cement or cement/lime plaster,any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed. |
| 10 | Taking down chowkats or frames with Shutters (without taking off shutters from the frame) not exc. 1.5 sq. m each complete all as specified & directed. |
| 11 | Taking down chowkats or frames with Shutters (without taking off shutters from the frame) exc. 1.5 sq. m but not exc. 4 sq. m each complete all as specified & directed. |
| 12 | Material and labour for 75mm thick providing PCC (1:3:6) type C2 using 40 mm graded aggregate as Plinth protection / Path finished the surface even & smooth with out using extra cement all as specified and directed. |
| 13 | M&L for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in floor surface finished even and fair complete all as specified and as directed. |
| 14 | Use and waste Formwork to soffits of suspended slabs such as roof slabs, landings and similar work, not exceeding 200mm thick( Horizontal or Sloping ), for rough finished flat surface of concrete all as specified and as directed. |
| 15 | M&L for RCC 1:1.5:3 type A-1 (using 20 mm graded stone aggregates) nominal mix as in slab supported on walls, roofs, landing, bolconies, deck slab and shelves complete all as specified & directed. |
| 16 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed |
| 17 | M & L for brickwork with subclass \"B\" or locally available best qualityold size bricks, straight or curved on plan exc 6 m mean raduis,built in CM (1:4) as half brick thick wall complete all as specified & directed. |
| 18 | Material and labour for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) on wall surface and finishing even and fair complete all as specified and directed |
| 19 | Material and labour for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) on wall surface with top 5 mm layer mixed with water proofing compound and finishing fair and even without usingextra cement complete all as specified and directed.NOTE : Water proofing compound shall be measured & paid separately. |
| 20 | Supply only integral water proofing compound complete all as specified & directed. |
| 21 | M& L for Vetrified Ceramic tiles light shade 8- 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set andjointed in neat cement slurry and pointed in white cement (mixed with colouring pigment to match the colour of tiles), laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 22 | M& L for Vetrified Ceramic tiles light shade 8- 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in skirting/dado on walls etc. and jointed in neat cement slurry and pointed in white or colour cement to match including10mm thick backing coat in cement mortar 1:4on walls complete all as specified and as directed. |
| 23 | M&L of Glazed ceramic coloured tilesin vertical surface size 450mm x 300mm x ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls complete all as specified and as directed. |
| 24 | M&L for 18-20mm thick granite stone slab, of any type, table rubbed and polished, in steps, jambs, pillars, window cills, cooking platforms and the like in laid over and including 20mm thick screed in cement mortar (1:6) with cement slurry 4.0 kg/ sqm including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab incl rounding edges complete all as specified and as directed. |
| 25 | Material and labour for rubber moulded Chequered coloured glossy finished cement concrete tiles 300x300x25 mm thick laying in floor, set & jointed and pointed in neat cement slurry in floor with white or coloured cement and pigment over & including 15 mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified. |
| 26 | S&F plates (plain or chequered) channels, square cut or notched (ordinay and counter sunk) forming holes, without any attachmentof Fe 410W (Gde-E -250) Quality \"B\" complete all as specified and directed by Engr-in-Charge. |
| 27 | Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-240 complete all as specified and directed |
| 28 | Supply and fix mild steel screw bolts 11 to 15 mm dia (machine made) with hexagonal or square heads at one end and screwed at the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 22.50cm and n exc 30cm long complete all as specified and directed |
| 29 | S&F for Pre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roofcovering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 30 | S&F for Pre-painted galvaume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roofcovering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 31 | Material and labour for Eves gutter with 1mm thick MS sheet, galvanised, class 3, half round, 150mm dia with rounded edges complete all as specified and directed, |
| 32 | Supply and fix 3 ways sliding anodized aluminium glazed window shutter with frame with the following specification all as specified & directed.(a) Window frame 3 track of size 95mmx25mmx1.5mm thick(b) Stiles and rails of size 35mmx25mmx1.5mm(c) 35mmx35x1.5mm T section mullion (d) PVC gasket with 4mm thick tinted glass, incl. aluminium handles with necessary locking arrangement for 02 Nos glazed shutter(e) Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples incl. aluminium handles with necessary locking arrangement for 01 No gauzed shutterNote : Measurement to be taken as overall width and height of window. No shutter or frame to be measured separately. All necessary accessories including tinted glass and stainless steel wire cloth required for assembling and fixing window at proper place complete are deemed to be inclusive. |
| 33 | Supply and fix 2 way sliding anodized aluminium glazed ventilators shutter top hung/fixed type with frame consists of following specification complete all as specified and directed. (a) Window frame 60mm x 25mm x 1.5mm thick(b)35mm x 35mm x 1.5mm Z section stiles, rails (c) 35mm x 35mm x 1.5mm T section million (d) PVC gasket with 4mm thick tinted glass, incl. aluminium handles with necessary locking arrangementNote : Measurement to be taken as overall width and height of window. No shutter or frame to be measured separately. All necessary accessories including tinted glass and stainless steel wire cloth required for assembling and fixing window at proper place complete are deemed to be inclusive. |
| 34 | S&F Aluminium anodized glazed doors shutter including frame with the specifications as door frame of size 50mm x 65mm x 1.5mm thick, Door shutter with styles of size 85mm x 45mm x 1.5mm thick, top and bottom rails sizes 100mmx 43mm x 1.5mm and lock rails size 85mm x 43mm x 1.5mm. Upper panel glazed with 5mm thick coloured glass and lower panel to be provided with 12mm thick prelaminated particle board, including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Screws, anodized Aluminium Snap Beading, anodized Aluminium Fittings such as Handles, 200 mm Long [2 Nos], Hinges, tower bolts, concealed locking arrangement etc complete all as specified and as directed.Notes: [a] Cost of Supply & fixing of Glass / prelaminated Particle board shall have deemed to be included in unit quoted rate.[b] Cost of Supply & fixing of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless steel Friction Hinges shall have deemed to be included in unit quoted rate. |
| 35 | Providing & fixing false ceiling with semi perforated 12 mm thick micro tegular edged of 10 mm thick square eadgeat all heights with GRG (glass fiber reinforced Gypsum ) false ceiling tiles of size 595X595 of approved texture design and patter having moisture contain less than 2%, humidity resistance of 99%,NCR 0.50 to 0.75 as per IS 8225, 1987, non combustible as per BS 475 ( Part -IV1970 and light code description unit rate No 429 SUB HEAD 26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85 % minimum to laid in true horizontal level suspended on interlocking metal T grid of hot dipped galvanized iron section of 0.33 mm thick ( galvanized @ 120 gms per sqmincluding both side comprising of main T runner of size 15X 32 mm of length of 3000 mm , cross T of size 15 X 32 mm of length 1200 mm and secondary intermediate crass T of size 15 X 32 of length of 600 mm to form grid module of size 600 X 600 mm suspended from ceiling using galvanized metal sheet item (galvanized @ 80 per sqm ie 50 mm long 8 mm outer dia meter M-6 , fasteners , 6 mm dia fully threaded hanger rod up to 1000 mm length and L shape level adjusters of size 85 X 25 galvanizediron perimeter wall angle of size 24 X24 X 0.40 mm of length 3000 mm to be fixed on perimeter of wall / partition with the help of plastic rawl pluhs at 450 mm centre to centre and 40 mm long dry wall screw . The work shall be carried out as per specification drg and as per direction of Engr-in-Charge. |
| 36 | Supply and fix Anodised aluminium snap grid frame work for false ceiling all as specified with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including 4 mm thick pre-painted decorative Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed |
| 37 | S & F Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame including dismantling as per specifications and drawing complete all as specified and directed. |
| 38 | S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame including dismantling as per specification and drawingcomplete all as specified and directed. |
| 39 | S&F for 25 mm dia and 1mm thick MS chromium platedcurtain rods with fixing side fancy type brackets end knobs fixed with steel screws etc all as specified and directed . |
| 40 | Complete removal of existing treatment on walls including washing rubbing down & stopping of cement base, distempered and other painted surfaces complete all as specified and directed. |
| 41 | Material and Labour for preparation of new or previously un-treated plastered surface and applying two coats of acrylic distemper over a coat of alkali resistant primer including 1mm thick wall care putty over newly plastered surfaces complete all as specified and directed. |
| 42 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed. |
| 43 | Material and labour for preparation of new or previously un-treated steel or iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 44 | Material and labour for preparation of old un-treated steel or iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint all as specified and directed. |
| 45 | E & M Division items |
| 46 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, sockets, lamp holder and conduit etc. removing materials to store fortaking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by EIC.Note:- The damaged surfaces to be made good with plastering& applying colour wash in required coats tomatching with existing surfaces as directed by Engineer-in-charge. Cost of the same deem to be included in quoted rates and nothing extra on this account admissible. |
| 47 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 48 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 49 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLSH copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable FRLSH as earth continuity conductor, 1100 volts grade, complete drawn in and including PVC Non metatilic concealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed for One light point controlled by one switch. |
| 50 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLSH copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable FRLSH as earth continuity conductor,1100 volts grade, complete drawn in and including PVC Non metatilicconcealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed forOne fan/ exhaust fan point controlled by one switch. |
| 51 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLSH copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable FRLSH as earth continuity conductor,1100 volts grade, complete drawn in and including PVC Non metatilicconcealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed forOne switch socket out let point 5 Amps on same board |
| 52 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLSH copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable FRLSH as earth continuity conductor,1100 volts grade, complete drawn in and including PVC Non metatilicconcealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed forOne switch socket out let point 5 Amps on independent board |
| 53 | M&L for point wiring with FRLSH stranded copper conductor2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directedfor 3 pin, 15 Amp socket outlet, independent |
| 54 | M&L for point wiring with FRLSH stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board as AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 55 | S&Fswitch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 56 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 57 | S&F switch socket combination 5 in 1 5/16 Amp flush type all as specified and directed. |
| 58 | Supply and fixing for ceiling rose surface bakelite 65 x 50 mm three terminal. |
| 59 | M&L for submain wiring with two single core 4 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid conduit concealed with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated FRLSH unsheathed multi strand copper conductor earth wire FRLS connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC conduit will be measured as one length. |
| 60 | M&L for submain wiring with two single core 6 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid conduit concealed with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 6.0 sqmm PVC insulated FRLSH unsheathed multi strand copper conductor earth wire FRLS connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC conduit will be measured as one length. |
| 61 | S&F 600 x 600 mm LED type down lighter 36 watt complete with drivers connecting accessories and provision of fixing arrangement in false ceiling complete all as specified and directed. |
| 62 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 63 | Supply and fixing LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. |
| 64 | S&Fbuilding security light LED fitting 25 watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant , epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover, with IP 66 protection with individual LED lences suitable for including lamp LED 25 watt, fixed / connect properly at directed location on building complete all as specified and as directed. |
| 65 | S&F plastic body exhaust fan300mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfacesand incl taking out existing old one with depositing to MES store yard complete all as specified and as directed. |
| 66 | S&FBLDC Ceiling fan 1200mm sweepsingle phase 230 volts AC, min air delivery 210 CFM with service valve 6.00 BEE 5 star rating withblade ,down roads electronic regulator andcomplete accessories complete fixed properly on wall surface with the provisioning of suitable sizes of rag bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 2.5 Sqmm 3 core and overall PVC sheathed which shall be passed through PVC flexible conduit of length not exceeding 0.50 mtr all as reqd and Taking down Old Ceiling fan with deposited toAGE Vairengte E/M Store as directed by Engr-in-Charge. |
| 67 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 68 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 69 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 70 | S&F MCB TPN of capacity 63 Amps,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 71 | S&F MCB SPN of capacity 40-63 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 72 | S&F MCB SP of capacity 5-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 73 | Taking out existing old earting and M&L for new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |