| 1 | M&L for Cement concrete type D2 1:4:8 using 40 mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed. |
| 2 | M&L for parking tiles of size 30x30 cm thickness of tiles 10-15 mm including screed bed of 20 mm thick in cement mortar 1:6 complete all as specified and directed. |
| 3 | M&L for cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 4 | M&L Providing and laying 65 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.Note:- Bed Rock Pattern Tiles of Approved make as per the direction of Eng-in-Charge. |
| 5 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 6 | Surface excavation n exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 7 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 8 | M&L for sand filling under floors including watering and consolidation complete all as specified and directed. |
| 9 | Demolition of Brickwork or stone/ boulder masonry , built in cement/lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 10 | M&L for rendering 15 mm thick in CM 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 11 | M&L for preparation of new plastered surfaces of walls and applying two coats of exterior emulsion paint of approved shade over a primer including 1 mm thick wall care putty complete all as specified and directed. |
| 12 | M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 13 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 14 | Excavation in post holes in soft/loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 15 | M&L for cement concrete type C-2 1:3:6 using 40 mm graded stone aggregates in mass concrete or in sub base to floors etc complete all as specified and directed. |
| 16 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240 complete all as specified and directed. |
| 17 | S&F rolled mild steel for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conformingFe 410 -W (Gde- E- 250) quality- A and incl necessary welding as per site requrement complete all as specified and directed. |
| 18 | M&L for mild Steel screw bolts machine made with hexagonal or square heads at one end and screwed the other both end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia of shank 11 to 15mm complete all as specified and directed. |
| 19 | M&L for preparation of new or previously untreatedsteel surface of any description, not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over one coat red oxide primer complete all as specified and directed. |
| 20 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 21 | M&L Providing precast cement concrete Type B0 1:2:4 (12.5mm graded) in louvres and jallies, 25mm thick (mea sured solid), including all mouldings but excluding frame set in CM 1:4 complete all as specified and directed. |
| 22 | M&L for Providing precast cement concrete type B1 1:2:4 (20 mm graded) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match set in CM 1:4 complete all as specified and directed. |
| 23 | M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, slabs, hooking ends and binding with and incl mild steel wire 0.9 mm dia complete all as specified and directed. |
| 24 | M&L for steel reinforcement of TMT bars (Fe-500 Grade)not exc 8 mm dia as in stirrups cut to length and bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 25 | Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc finish withrough finish flat surface complete all as specified and directed. |
| 26 | Schedule of Credit |