| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil, complete all as specified & directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as specified & directed. |
| 3 | M&L for cement concrete 1:4:8, type D-2 , (40mm graded stone aggregate) as in foundations, filling and mass concrete, complete allas specified. |
| 4 | M&L forbroken stone / boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified. |
| 5 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceedingeeding 25 cm |
| 6 | Removing excavation material exceeding 1.50 km but n exceeding 15 km and depositing where directed |
| 7 | M&L for RCC (design mix) M-30 (20mm graded aggregate) as in footing, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed. |
| 8 | M&L for RCC (design mix) M-30 (20mm graded aggregate) as in roof beams, cantilevers, bressummers lintels over 1.5m span complete all as specified and directed. |
| 9 | Material & labour RCC (design mix) M-30 (20mm graded aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 10 | Material & labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with |
| 11 | Material & labour for mild steel TMT bars 5mm dia and over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with complete all as specified and directed. |
| 12 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batterfair finished surfaces. |
| 13 | M&L for flat Formwork to sides of pillars, posts, struts, piers, columns and stanchions fair finished surfaces. |
| 14 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc fair finished surfaces. |
| 15 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, upto 15th floor of bldg.,complete all as specified. |
| 16 | Rendering 15mm thick cement plaster in cement mortor 1:4 on brick or concrete surfaces mixed with water proofing compound @ 2% by the weight of cement (shall be paid under respective schedule), surfaces to be finished even and smooth without using extra cement, complete all as specified.Note: Water Proofing Compound will be measured and paid seperately as supply only |
| 17 | Supply only integral water proofing compound. |
| 18 | Preparation of newly plastered surfaces of wall and apply two coats ofAcrylic emulsion exterior paint (all weather proof) of required shade over a coat of exterior primer, complete all as specified. |
| 19 | M&L for preparation of new steel surfaces of any description over 10cmwidth or girth and applying two coat of synthetic enamel paint over a coat of red oxide, complete all as specified. |
| 20 | M&L for preparation of old steel surfacesof any descriptionand applying two coat of black bituminous paint complete all as specified. ( incl all necessary scaffolding etc.) |
| 21 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, any description including Nainital or similar pattern roof coverings or as in valley gutter complete all as specified and directed. |
| 22 | S&F Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws allas specified. |
| 23 | Fixing only Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws allas specified. |
| 24 | S&F Plain galvanised mild steel sheeting 1.25 mm thick in ridges hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 and opening for rain water pipe to be provided fixed with MS Flat complete all as specified and directed. |
| 25 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 26 | M & L for MS flat for hold fast wind ties etc Conforming to Fe-310-0 or Fe-410-0 |
| 27 | S&F rolled sections as in main & cross beams , columns, hip and jack rafters , purlins where connected to common rafters and running rails,wind ties & any other places with angles cleats ot other connected plates confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified. |
| 28 | S&F plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attahment,confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified. |
| 29 | Dismantling of safety net/ bird proofing mesh of any thickness and size fixed with steel frame work complete all as specified and directed. |
| 30 | S&F Mild steel galvanised PVC Coated wire netting to ceiling, dia of wire 2.50mm and size of mesh 25mm x 25mm fixed with 4mm dia GI Wire and cleat including wooden patti at side, whereever required complete including tightening of wire netting etc all as specified and directed. |
| 31 | M&L for brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 all as specified and directed. |
| 32 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius inhalf brick thick wallsbuilt in CM (1:4), complete all as specified. |
| 33 | M&L for RCC(1:1 1/2:3) using 20mm graded stone aggregate as in slabs supported on walls all as specified and directed. |
| 34 | Use and waste of formwork tosuspended roof slabs not exceeding 200 mm thick finished surfce fair smooth finished of concrete flat all as specified and directed. |
| 35 | Use and waste of formwork to edges of concrete flats as in roof slabs exc 5 but n exc 10 cm wide suspended slabs n exc 200mm thick for rough finished surfaces of concrete flatall as specified and directed. |
| 36 | M&L for TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clipsall as specified and directed. |
| 37 | M&L for RCC(1:1 1/2:3) using 20mm graded stone aggregate as in lintelsall as specified and directed. |
| 38 | M&L for rendering 12mm thick on fair faces of brick or concrete surface in cement mortar 1:6all as specified and directed. |
| 39 | M&L for rendering 15mm thick on fair faces of brick or concrete surface in cement mortar 1:4.finished surfce even all as specified and directed, |
| 40 | M&L 15mm thick rendering/ screed on terrace or concrete surfacesin cement mortar 1:4finished even and fair. ( using water proofing compound) |
| 41 | PCC 1:2:4 type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, benching rounded or chamfered on edges completeall as specified and directed.. |
| 42 | Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification & drawingall as specified and directed. |
| 43 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottomrails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail ; Panelling of plain colour PVC sheet to be fitted in the MS frame welde/ sealed to the styles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drawingall as specified and directed. |
| 44 | S&F stainless steelbutt hinges, 100mm all as specified and directed. |
| 45 | S&F extruded aluminium alloy handles, fabricated type, anodised 125mm long |
| 46 | S&F Aluminium anodised, barrel tower bolts of extruded section 150mm long |
| 47 | S&F aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections ans fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, 200mm longall as specified and directed. |
| 48 | M&L for 25mm thick cement concrete type B-0 1:2:4 (12.5mm graded aggregate) as in sub floorall as specified and directed. |
| 49 | M&L Non skid ccerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile 0.11 Sqm but n.exc 0.18 Sqm, in neatcement slurry and pointed in white or coloured cementwith pigment to match over 15mm thick screed bed in cement mortar (1:6)all as specified and directed. |
| 50 | M&L Glazed ceramic colouredtiles (350X250/450X350mm) x6-7mm thick on vertical surfaces as in skirting/dado, set and jointed with neatcement slurry and pointed in white/coloured cement to match the shade of tiles over 10mm thick rendering in cement mortar 1:3all as specified and directed.. |
| 51 | S&F vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) |
| 52 | S&F vetrreous china coloured Urinal partition size 300X700 mm all as specified and directed. |
| 53 | M&L for preparation of new plastered wall surfaces and applyingtwo coats of oil bound distember all as specified and directed. |
| 54 | M&L for preparation of newly plasteredsurfaces of wall and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) includingnecessary scaffolding for high raise bldg complete all as specified and as directed |
| 55 | S&F viterous china ware wash down water closet pan (Pedestal Pattern) colouredand plastic seat and cover with MS CP hinges (excluding fixing bolts, flushing cistern and floor pipe complete.all as specified |
| 56 | S&F vitreous china wash basin coloured, flat back, size 550 x 400mm, fixed with brackets incl 32mm bore CP waste coupling, flexible waste pipe etc ,all as specified and dircted.. |
| 57 | S&F PVC valveless syphonic action type flushing cistern, low level,coloured, with inlet, ball valve, float and handle incl flush pipe fixing to EWCall as specified and directed. |
| 58 | S&F PVC connections 15mm size with PTMT nuts of lentyh 450mmall as specified and directed. |
| 59 | S&F as in repairs Health faucet (ABS Body) Cat Part No. ALD-CHR-587of Jaquar or of equivalent inParryware or Hindwareas aprroved mild steel chromium plated suitable for 15 mm dia pipe with 1.00 metre long spirochrome Flexible tube and wall hook including making connections and fixed in position complete all as specified and directed. |
| 60 | S&F in repairs fancy type CP Pillar tap 15 mm dia, with capstan heads, screwed down high pressure, with long screwed shanks and fly-nuts, screwedand fixed complete all as specified. |
| 61 | S&F 15mm bore CPVC pipes of pressure rating 10 Kg/cm2 fixed complete to wall or ceilingor in floor etc. , with all fitting and where ever concealledcompleteall as specified. |
| 62 | S&F 15mm bore stop valves/ Angle valve , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixedall as specified and directed. |
| 63 | S & Ftwin Bib tap 15 mm CP withn srewed for iron pipe or for brass ferrule and fixed all as specified. |
| 64 | S & F 15mm dia concealed fancy type stop valve copper alloy with chromium plated fixed to iron pipe all as specified. |
| 65 | S & F looking mirror 450X600mm with plywood backing and aluminium frame all as specified and directed by Engineer-in- Charge. |
| 66 | S&F Stainless steel Towel rail 600mm longincluding necessarybrackets complete all as specified and as directed. |
| 67 | S&F in repairs stainless steel soap dish holder of approved makefixed with brass screwto wall complete all as specified and directed. |
| 68 | S&F powder coated (colour of coating as directed) aluminium (minimum 25 micron thickness of coating) ofvarious section as required/suitable for doors, window & partion/Ventilator (sliding /or openable type)etc including fixing and making the frames hinges to receive glass/wire gauge etc.Complete incl all fittings like jointing cleats, glazing clips, rubber neoprene packing. anodised aluminium snap beading screws etc.rubber beading, clips locking arrangement, handle, sealant etc all as specified and as directed. |
| 69 | S&F in repair aluminium grill with and including suitable aluminiumanodised frame F/H section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, as directed by Engr- in- charge. |
| 70 | S&F 4 mm thick glass sheet ordinary quality frosted on one side, n exc 0.5Sqm in each pane,fixed to Aluminium windows. |
| 71 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed to walls complete. |
| 72 | S&F 75mm bore PVC branch pieces with oval access door, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branchesall as specified and directed. |
| 73 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed to walls completeall as specified and directed.. |
| 74 | S&F 100mm bore cast iron cowlsall as specified and directed. |
| 75 | S&F PVC (SWR) \"P’ trap 100mm boreall as specified and directed. |
| 76 | S & F PVC (SWR) Floor trap of 75 mm outlet plain with grating including jointing with solvent cementall as specified and directed.. |
| 77 | S&F for 200mm bore RCC pipe class NP-3 laid and jointed complete with collers as specified including testing all as specified and directed by Engineer-in-Charge. |
| 78 | M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes including forming cradle after they are laid and tested for 200mm bore RCC pipe complete all as specified and as directed by Engineer-in-Charge. |
| 79 | M&L precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manhole covers and the like set in cement mortar (1:4) duly placed on manholescomplete all as specified and directed by Engineer-in-Charge. |
| 80 | Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified. |
| 81 | Removal of surplus soil to a distance exc 50 Mtr and n exc 100 Mtr and depositing where directed at a level n exc 1.5 Mtr above starting point in soilall as specified and directed. |
| 82 | Providing and applying two coats of 100% acrylic exterior weatherproof emulsion paint of approved make,on Old surfaces with anti-algae and anti-fungal properties, over one coat of primer, including surface preparation, scaffolding, curing, etc. complete as per manufacturer’s specification and direction of engineer in charge. |
| 83 | Providing and applying fair finish 15mm thick plasterwith readymix prepacked proportioned dry mix mortar (1:6) fair faces of brick wall or concrete surfaces additives, on internal surfaces including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge. |
| 84 | Material and labour for preparation of new plastered surface of wall and applying 2 coats of oil emuslion distemper over a coat ofprimer on 3 mm thick wall care putty all as specified and directed. |
| 85 | Providing and applying fair finish 10mm thick plasterwith readymix prepacked proportioned dry mix mortar (1:3) fair faces of Ceiling surfaces, on internal surfaces including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge. |
| 86 | M&L for preparation of newly plastered surfaces and of ceiling applying two coats of oil emlusion distemper white or tintedover a coat alkali resistant priming paint over 3mm thick wall care putty on wall complete all as specified and as directed . |
| 87 | Demolition of cement concrete(unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or aboveground level) complete all as specified. |
| 88 | M&L for rendering 10mm thick cement plaster in cement Mortar 1:4 on concrete surfaces as on roof finished even and smooth without using extra cement complete all as specified and directed. |
| 89 | M&L for water proofing treatment to RCC roof slab all as specified below and as directed:-(a) Apply one coat of bitumous primer @ 0.25 Kg/Sqm.(b) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area.(c) Laying APP polymer modified membrane 4mm thick with non woven polyster reinforcement weighing not less than 4.00 Kg/ Sqm applied by torch application method.(d) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/sqm of the surface area.(e) Apply a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm. |
| 90 | M&L for preparation of old painted steel surfaces of any description over 10cmwidth or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 91 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 Core. |
| 92 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 Core. |
| 93 | Supply & fix inIndustrial highbay integral LED fittings of capacity 120 wattluminaire with high efficacy capacity in aluminium pressure die cast housing with touched glass cover with IP 65 protection complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearnce complete all as specified and directed by Engr-in-charge. |
| 94 | S&FDB 4 way Double doorTPNtype, 415 volt having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed. |
| 95 | S&FMCB, DB, SPN 8 way double door with protection type IP-42with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified anddirected. |
| 96 | S & F MCB TPN 40 to 100 Amps, 415 volt, 10 KA rating complete all as specified anddirected. |
| 97 | S & F , MCB SPN 40 to 63 Amps, 10 KA ratingcomplete all as specified anddirected. |
| 98 | S & F , MCB SP 6-32 Amps, 10 KA rating complete all as specified anddirected. |
| 99 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge. |
| 100 | M & LEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm complete all as specified and directed. |
| 101 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets,light fitting etc. removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc |
| 102 | M & L for Point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated sheathed copper conductors 1100 volts grade drawn through & including PVC non-metallic double locked casing ISI marked with accessories fixed in wall/ceiling/truss including cutting chases, pinning in etc with PVC non metallic ISI marked terminal boxes concealedwall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specifed and directed. |
| 103 | (a) One light point controlled by one switch SP one way. |
| 104 | (b) One exhaust fan point controlled with one 5A switch. |
| 105 | (c) One 3 pin socket outlet 5Amps on independant board. |
| 106 | (d)One 3 pin socket outlet 5Amps on same board with other switches. |
| 107 | Material and Labourpoint wiring for 15 Amps socketcomplete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic double locked casing and capingincludingPVC bend,teejointsetc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specifed and directed. |
| 108 | S&F Modular Switch , 6Amp, One way, 1 module, ISI marked complete all as specified and directed. |
| 109 | S&F Modular Switch , 16Amp, One way, 1 module, ISI markedcomplete all as specified and directed. |
| 110 | S&F Modular Socket , 6 Amps, 2/3 pin combined2 module, ISI marked complete all as specified and directed. |
| 111 | S&F ModularSocket , 16Amps, 6 pin combined 2 module, ISI marked complete all as specified and directed. |
| 112 | S&F ceiling rose surface bakelite with ISI mark,three terminals complete all as specified anddirected. |
| 113 | S&F Modular white cover plate with Frame 3 Module, ISI marked complete all as specified anddirected. |
| 114 | S&FModular white cover plate with Frame 6 Module, ISI marked complete all as specified anddirected. |
| 115 | S&F Modular metal flush box 3module, ISI marked and including cutting hole in wall / ceiling/piller etcand making good surface complete all as specified anddirected. |
| 116 | S&F Modular metal flush box6module, ISI marked and including cutting hole in wall / ceiling/piller etcand making good surface complete all as specified anddirected. |
| 117 | Supply and fixing integrated LED batten 20 Watt, 4 feet long, full white in Engineering plastic battern with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 118 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 Core including taking down complete all as specified and directed by Engr in Charge. |
| 119 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 Coreincluding taking down complete all as specified and directed by Engr in Charge. |
| 120 | Supply & fix inIndustrial highbay integral LED fittings of capacity 150 wattluminaire with high efficacy capacity in aluminium pressure die cast housing with touched glass cover with IP 65 protection complete and all accessories at top of any height of workshop hanger including proper hanging fixing with new angle/rond bar flat iron clamp length as required as per site as good appearnce complete all as specified and directed by Engr-in-charge. |
| 121 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. all as specified and directed by Engineer-in-Charge. |
| 122 | S&FDB 4 way Double doorTPNtype, 415 volt having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed. |
| 123 | S&FMCB, DB, SPN 8 way double door with protection type IP-42with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified anddirected. |
| 124 | S & F MCB TPN 40 to 100 Amps, 415 volt, 10 KA rating complete all as specified anddirected. |
| 125 | S & F , MCB SPN 40 to 63 Amps, 10 KA ratingcomplete all as specified anddirected. |
| 126 | S & F , MCB SP 6-32 Amps, 10 KA rating complete all as specified anddirected. |
| 127 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge. |
| 128 | M & LEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm . |
| 129 | Supplyand fixingexhaust fan , Plastic body AC single phase, 230 volt of size 250 mm sweep1280 RPM, 36 watt, Air delviry 800 cmh, no of blade -05 nos, insulation resistance - 2 mega ohm, with blades, and frame andlouverscomplere fixing arrangements on the wall/windowwithnuts and boltsmaking the good surfcesall as specifed and directed. |
| 130 | Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & diected |
| 131 | M&L for cutting of Road/hardstanding not less than 30 cm in depth and 30 cm in width underneath the road for passing the cable/pipe and making good with PCC 1:2:4 type B-1whete road cutting done to make the road surface fair and level complete all as specified and directed by Engr-in Charge. |
| 132 | S&F HDPE of Pressure rating 6kg/cm sq pipe of 40 mm dia including necessary bends,elbows,Tees etc on cable protection complete all as directed. |
| 133 | S&F 20 mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in trenches/wall/ceiling/ floor/ , all as specified and directed . |
| 134 | Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 135 | S&F Rotational moulded polyethylene water storage tanks 200 Ltr(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part 1 complete all as specified and directed by Engr in Charge. |