| 1 | Taking down/ out carefully copper/aluminium point wiring for light/fan/bell/ sockets 5/15 Amps complete without accessories as switches,Sockets, holders,ceiling roses,light fitting regulators etc ( to be measured separately) and making good the disturbed surface all as directed. |
| 2 | M&L for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated un-sheathed and stranded copper conductor cable ISI marked drawn through concealed conduit and PVC conduit fittings such as tees, bends, elbow, reducers except conduit junction box (junction box will be of MS) including FRLS, PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and including modular box covered withmodular top coverfor mounting switches, sockets or fan regulators etc for the following :- (a) One light point/ fan point/ bell point controlled by one switch |
| 3 | All as per item No 02 here-in-before butOne socket outlet 5 Amps controlled by one switch on same board |
| 4 | All as per item No 02 here-in-before but One socket outlet 5 amps controlled by one switch on independent board |
| 5 | All as per item No 02 here-in-before but one light point controlled by two 2 way switches |
| 6 | All as per item No 02 here-in-before but wiring with 2.5sqmm copper wire and 2.5sqmm earth wire for socket out let on independent board. |
| 7 | S&F in repair modular switch flush type, 6 amps one way,SP,230 volts AC all as directed. |
| 8 | S&F in repair modular switch flush type, 6 amps two way,SP,230 volts AC all as directed. |
| 9 | S&F in repair modular switch flush type, 16 amps one way,SP,230 volts AC all as directed. |
| 10 | S&F in repair modular switch bell push flush type, 6 amps one way,SP,230 volts AC all as directed. |
| 11 | S&F in repair modular socket outlet 6 amps 5 pin 2 moduleall as directed. |
| 12 | S&F in repair modular socket outlet 6 & 16 amps 6 pin multipurpose combined 2 module all as directed. |
| 13 | S&F in repair modular Step Fan regulator, 120 watts single / double module all as directed. |
| 14 | S&F in repair Modular white cover plate with frame 1 module all as directed |
| 15 | S&F in repair Modular white cover plate with frame 2 module all as directed |
| 16 | S&F in repair Modular white cover plate with frame 3 module all as directed |
| 17 | S&F in repair Modular white cover plate with frame 4 module all as directed |
| 18 | S&F in repair Modular white cover plate with frame 6 module all as directed |
| 19 | S&F in repair Modular white cover plate with frame 12 module all as directed |
| 20 | S&F in repair Modular Metal Flush Box 1/2 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making goodthe existing surface complete all as specified and as directed |
| 21 | S&F in repair Modular Metal Flush Box 3 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making goodthe existing surface complete all as specified and as directed |
| 22 | S&F in repair Modular Metal Flush Box 4 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making goodthe existing surface complete all as specified and as directed |
| 23 | S&F in repair Modular Metal Flush Box 6 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making goodthe existing surface complete all as specified and as directed |
| 24 | S&F in repair Modular Metal Flush Box 12 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making goodthe existing surface complete all as specified and as directed |
| 25 | S&F in repair switch piano flush type, 6 amps one way,SP,230 volts AC all as directed. |
| 26 | S&F in repair switch piano flush type, 6 amps two way,SP,230 volts AC all as directed. |
| 27 | S&F in repair switch piano flush type, 16 amps one way,SP,230 volts AC all as directed. |
| 28 | S&F in repair switch pianobell push flush type, 6 amps one way,SP,230 volts AC all as directed. |
| 29 | S&F in repair socket outlet 6 amps 5 pin , all as directed. |
| 30 | S&F in repair socket outlet 6&16 amps 6 pinall as directed. |
| 31 | S&F in repair piano type Stepfan regulator, 120 watts single/ double module all as directed. |
| 32 | Supply and fixing in repair of lamp holder PVC/ Polycarbonate type insulated body with back plate suitable for batten fittings complete all as specifed and as directed. |
| 33 | Supply and fixing in repair of Ceiling rose, insulated body, 3 terminal, 240 volts complete all as specified and as directed, |
| 34 | Fixing only in repair of electric bell of DINGDONG type, 6 Amps, 240 volts, single pole and making all necessary connections complete all as directed. |
| 35 | Labour only in repair of submain wiring complete with 2 x 4.0 sqmm(nominal area) FRLS, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 4 sqmm( same specification ) as earth wirein existingPVC conduitcomplete all as directed |
| 36 | Material and labour for repair of submain wiring complete with 2 x 10.0 sqmm(nominal area) FR, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 10 sqmm( same specification ) as earth wirein existingPVC conduit complete all as directed. |
| 37 | Material and labour for repair of submain wiring complete with 2 x 16.0 sqmm(nominal area) FRL, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 16 sqmm( same specification ) as earth wirein existingPVC conduit complete all as directed. |
| 38 | Material and labour for repair of submain wiring complete with 4 x 10.0 sqmm(nominal area) FR, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 10 sqmm( same specification ) as earth wirein existingPVC conduit complete all as directed. |
| 39 | Material and labour for repair of submain wiring complete with 4 x 16.0 sqmm(nominal area) FRL, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 16 sqmm( same specification ) as earth wirein existingPVC conduit complete all as directed. |
| 40 | Supply and fixing in repair of MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed. |
| 41 | Supply and fixing in repair Isolator SPN 40 A including connections complete all as specified |
| 42 | Supply and fixing in repair Isolator SPN 63 A including connections complete all as specified |
| 43 | Supply and fixing in repair Isolator TPN 40 A including connections complete all as specified |
| 44 | Supply and fixing in repair Isolator TPN 63 A including connections complete all as specified |
| 45 | Supply and fixing in repair Isolator TPN 100 A including connections complete all as specified |
| 46 | Supply and fixing in repair ofModular AC Socket with 25 Amps SPmini MCB, 230 Volts, 50Hz. In 4 module sheet metal enclosure complete all as specified and as directed. |
| 47 | Supply and fixing of PVC casing & caping ( ISI marked)20 mm width double lock type inclusive of all fittings such as tees, bends, elbow, etc and all fixing accessories such as couples,Pvc Rawal Plugs, saddles, etc complete all as directed. |
| 48 | Supply and fixing of PVC casing & caping ( ISI marked)25 mm width double lock type inclusive of all fittings such as tees, bends, elbow, etc and all fixing accessories such as couples,Pvc Rawal Plugs, saddles, etccomplete all as directed. |
| 49 | S&F in repair of rigid non metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete all as specified and and as directed. |
| 50 | S&F in repair of rigid non metallic PVC conduit 25 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete all as specified and and as directed. |
| 51 | S&F in repair of rigid non metallic PVC conduit 32 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete all as specified and and as directed. |
| 52 | Supply and fixing in repair of wall light fitting decorative type suitable for LED lampcomplete all as directed. |
| 53 | S & F in repair LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 20 Watts, cool/warm white as per site requirement complete all as specified and directed. |
| 54 | S & F in repair ofLED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 10 Watts, cool/warm white as per site requirement complete all as specified and directed. |
| 55 | Fixing only in repair of LED bulk head fitting complete all as specified and directed. |
| 56 | S&F in repair of Recess/Surfacemounting 2x2 square flat panel ultra slim scoop LED light 36 W warm/cool white with driver/transformer etc suitable for Grid ceiling/Gypsum board/POP ceiling incl making electric connection complete as as directed. |
| 57 | Supply and fixing in replacement of LED ceiling light fitting 15 watt, in round shape, surface/recess type cool/warm white with inbuilt driver as per site requirement and making all electric connections complete all as directed. |
| 58 | Supply and fixing in replacement of LED ceiling light fitting 10 watt, in round shape, surface/recess type cool/warm white with inbuilt driver as per site requirement and making all electric connections complete all as directed. |
| 59 | Supply and fixing in repair of Ventilatingfan 200 mm sweep plastic body type including self cosing louver and making all electric connections complete all as directed. |
| 60 | S & F in repair plastic body capacitor of capacity 2.5 mfd with wire suitable for single phase motor and making connection complete all as specified and directed |
| 61 | S&F PVC Gang Box suitable for one No 5 Amps Switch and one No 5 Amps Socket complete all as specified and as directed. |
| 62 | S&F PVC Gang Box suitable for two No 5 Amps Switch and two No 5 Amps Socket complete all as specified and as directed. |
| 63 | S&F PVC Gang Box suitable for one No 15 Amps Switch and one No 15Amps Socket complete all as specified and as directed. Make : Presto plast/Pressfit/Polyplast. |
| 64 | S&FSteel fastneer of 4\" long and 8mm dia with Nuts& washer complete all as specified and as directed. |
| 65 | S & F in repair of MCCB, 415 volts, three pole of cap 100/125 Amps, 10 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including necessary spreader / thimbles of suitable size and making connections complete all as directed. |
| 66 | S & F in repair of aluminium cable 1100 Volt grade, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable circular of size 4 SqmmISI marked in service connections, including taking down oldunserviceble cable complete all as directed. |
| 67 | All as per srl item no. 83 here-in-before but with 6.0 sq mmISI marked in service connections, including taking down oldunserviceble cable complete all as directed. |
| 68 | S & F in repair of socket 3 pin 10/20 amp earth metal clad suitable for industrial type DB complete all as directed. |
| 69 | Supply and fixing in repair of\"T\" coverBakelite sheet 2 mm thick in round shape complete all as specified. |
| 70 | Supply and fixing in repair of Bakelite sheet 3mm thick of size 5\"x5\" duly wire cut for switches, sockets, regulator etc as per site requirement as directed. |
| 71 | S&F in repair of Bakelite sheet 3mm thick of size 8\"x5\" duly wire cut for switches, sockets, regulator etcas per site requirement as directed. |
| 72 | S&F in repair of Bakelite sheet 3mm thick of size 9\"x11\"duly wire cut for switches, sockets, regulator etcas per site requirement all as directed. |
| 73 | S&F in repair of Bakelite sheet 3mm thick of size 11\"x13\" duly wire cut for switches, sockets, regulator etcas per site requirement all as directed. |
| 74 | S&F of MCB DB confirming to IP 43 - IK 09 with double door, SPN 12 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces. |
| 75 | S&F of MCB DB confirming to IP 43 - IK 09 with double door,SPN 08 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces. |
| 76 | S&F of MCB DB confirming to IP 43 - IK 09 with single door,SPN 04 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces. |
| 77 | Supply and fixingin repair of MCCB incommer Distribution Board ( Vertical Load line DB)double Doormade out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incommer and MCB as outgoing and making all necessary connections and taking out the old unserviceable DB complete all as directed.Note:- MCCB & MCBs will be measured and paid separately |
| 78 | S&F in repair of TPN DB 04 way double door confirming to IP43 & IK 09 protection complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces. |
| 79 | Material and labour for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground not less than 2.25 mtrs below ground level with top edge of plate not less than 1.5 mtr deep below normal ground level connected to galvinised earth wire 4 mm by means of nuts, bolts and check nut to earth plate and to main board or DB including necessary PCC 1:2:4 type B-1 pit, cover frame , GI pipe 15 mm dia light grade for protection and GI pipe 20 mm dia medium grade for watering with funnel, wire mesh, salt and charcoal dust all over the plate all as specified and as directed. |
| 80 | Hanging only ceiling fan and connecting up including provision of copper cable flexibe from ceiling rose to connector of fanand taking out old fan and deposited to MES store yard complete all as specified and as directed |
| 81 | Fixing only Water Heater ( Geyser) any type and capacity including connection and taking out old and depositing to MES store yard complete all as specified and as directed |
| 82 | M&L for cutting chases in brick walls/ PCC for inserting PVC conduit any size and making good with CM 1:3 to finish the surface complete all as specified and directed |
| 83 | S & F in replacement of energy efficient LED fittings 35W LED suitable for building security light pressure die cast aluminium roadway luminaire with high power LEDs and HF electronic driver complete all as directed. |
| 84 | Supply and fixing in replacement of street light fitting bracket, 1.0 mtr long made out of galvanized iron pipe of 25 mm dia size light grade complete with nut, bolts, washer, clamps etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed. |
| 85 | S&F in replacement of heating element 3KW with gasket suitable for solar water heater tank including connection complete all as specified and as directed. |
| 86 | M&L in replacement for single pointed aluminium rod12 mm dia and 300 mm long fixed on the roof including all fittings, fixtures and PCC 1:2:4 type B-1 blocks 150mm x 150mm x 150mm complete all as specified and directed. |
| 87 | M&L in replaement for aluminium strip 25mm x 3.00 mm complete with new porceline insulator by means of screws of suitable size for isolation of strip complete all as specified and directed.Note : Over laping aluminum strip 50 to 60cm distance fitted porceline insulatorfor brass screw with washer and overlaping strip for two Rivite fitted in strip) including quated rate. |
| 88 | M&L in replacement for Porcelain insulatorfor suitable size for galvanised iron strip including screwed with double washer complete all as specified and directed. |
| 89 | M&L for galvanized iron strip 32x6 mm connecting at ends, jointing etc complete all as specified and directed. |
| 90 | M&L for providing earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried dirictly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth strip 25x4mm size upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-1 and connected to equipment including necessary excavation/ earth work in any type of soil/rock strata,funnel with wire mesh and 20mm dia pipe for protection of earth wire PCC pit with 40mm thick PCC cover etc. complete all as specified and directed.Note : Earthing test result submitted after completed of the earth workownarrangement for teast equimpment. |
| 91 | M&L in replacement for test pont terminal block made out gun metal/phosphorus bronze of size 75x75x25mm drilled and screwed incl 3 Nos 8mm dia 25mm long hex. Head screw complete all as specified and directed. |
| 92 | Supply and fixing in replacement of steel wired connection 600mm long and C P brass adopter 10 mm dia with washer for geyser of any type/Make and capacity complete all as directed. |