| 1 | SCHEDULE \"A\" PART-I-BUILDINGS & STRUCTURES INCLUDING INTERNAL & EXTERNAL SERVICES AS DEFINED IN ANNEXURE I TO XII (EPC) AND AS MENTIONED BELOW: |
| 2 | (a) Construction of Multi-Storeyed deficient Married Accn for POs and below in 02 Towers (G+32 Floors for 232 DUs) total for 464 DUs incl Multi-level parking for Cars & Two Wheelers, Internal services with (02 Towers) permanent specification all as specified.(b) Construction of Sub Station Bldg (G+1) including internal services with permanent specification all as specified.(c) Construction of Pump House Building (Single storey) for Fire Fighting cum fresh water including internal services with permanent specification all as specified.(d) Composite Sump for fresh water and fire fighting.(e) Terrace Tanks for fresh water (domestic purpose), fire fighting and grey water. |
| 3 | SCHEDULE \"A\" PART-II (EXCAVATION AND EARTHWORK)Total of Sch-\"A\" Part-II B/F |
| 4 | SCHEDULE \"A\" PART-III (TREATED WATER SUPPLY)Total of Sch-\"A\" Part-III B/F |
| 5 | SCHEDULE \"A\" PART-IV (ROAD AND HARDSTANDING)Total of Sch-\"A\" Part-IV B/F |
| 6 | SCHEDULE \"A\" PART-V(EXTERNAL WATER SUPPLY)Total of Sch-\"A\" Part-V B/F |
| 7 | SCHEDULE \"A\" PART-VI (EXTERNAL ELECTRIC SUPPLY) Total of Sch-\"A\" Part-VI B/F |
| 8 | SCHEDULE \"A\" PART-VII (SEWAGE DISPOSAL)Total of Sch-\"A\" Part-VII B/F |
| 9 | SCHEDULE \"A\" PART-VIII (AREA DRAINAGE)Total of Sch-\"A\" Part-VIII B/F |
| 10 | SCHEDULE \"A\" PART-IX (COMPOUND WALL)Total of Sch-\"A\" Part-IX B/F |
| 11 | SCHEDULE \"A\" PART-X (ARBORICULTURE)Total of Sch-\"A\" Part-X B/F |
| 12 | SCHEDULE \"A\" PART -XI (MISCELLANEOUS ITEMS) |
| 13 | SITE CLEARANCE & EARTHWORK |
| 14 | Removing excavated material (any type) and depositing it outside Ministry of Defence Land.Note:(i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account.(ii) This item shall be considered as per the requirement at site.(iii) All excavation earthwork covered under Sch\"A\" Part III to Part IX shall be measured and paid under this item. |
| 15 | EXTERNAL ELECTRIC SUPPLY |
| 16 | M&L for Cable path indicator made out of 3mm thick MS sheet of size 30x20 cm fixed on 40x40x5 mm 75mm long angle iron including letters writing (HT Cable 11000 V) and PCC complete all as specified and directed by Engineer-in-Charge. |
| 17 | EXTERNAL WATER SUPPLY |
| 18 | Supply and laying Ductile Iron pipes 200mm dia centrifugally cast (spun), Class K9, with spigot and socket endsRubber gasket joint (Tyton joint) suitable for DI pipe 200mm dia conforming to IS 8329/2000 in any length suitable for push-on joints, laid in trenches complete all as specified and as directed. |
| 19 | Supply and fixing DI fittings such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable upto 200mm dia, class K-9 complete all as specified and directed. |
| 20 | Supply, Installation Testing & Commissioning of Motor Actuated Butterfly Valve of 200 mm dia consisting of Quarter turn single phase Actuator and Wafer type butterfly valve with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Direct including control cable upto existing PLC panel. |
| 21 | Cutting in position existing cast iron main pipe line of size 300 mm dia, insertion of CI tee 300 x 300 x 200 mm bore for tapping out for main water supply connection including connected fittings i.e. CI Tee, collar, tail piece, run lead joints and necessary excavation, refilling and disposal of surplus material complete as directed. |
| 22 | Construction of brick masonary valve chamber in repair of size 1.2mx1.2mx 1.0 mtr (internal diamension) 15 cm thick foundation using PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) over 15 cm thick hardcore, 23 cm thick brick wall bults in cement and sand motor 1:4, 15 cm thick internal and external plaster including top floor in cement and sand motor 1:3, finished even and smooth, without using extra cement, 10 mm thick mild steel platecover on 50 mm x 50 mm x 6 mm MS angle iron frame embeded in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangement & handle made out of 25 cmdia MS round bar, hold fast etc, applying one coats od red oxide primer and two coats of synthetic enemelledpaint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not ex 50 mtr complete. |
| 23 | TREATED WATER SUPPLY |
| 24 | Supply, lay, test and commissioning MS class-C pipe 150 mm bore,with flange joint, ISI marked with and including other specials/fittings as required at site complete all as specified and as directed. |
| 25 | Supply, lay, test and commissioning MS Class - Ctubing, 100 mm dia flange joints, in any length,including other specials/fittings as required at site complete all as specified and as directed by Engr-in-Charge. |
| 26 | Supply, lay, test and commissioning150 mm bore, HDPE PE- 100 PN- 20 with suitable joint,ISI marked with and includingspecials/fittings as required at site, complete all as specified and as directed. Note : Excavation, RFR shall be measured and paid separately. |
| 27 | Supply, installation, testing and commissioning of centrifugal pump-set cast iron body discharging clean water 420 LPMat 130 mtrs with CI impeller, pump shaft carbon steel, sealing includingS&F of pressure gauge with one controlling ball valve and priming arrangement with GI pipe line,valve etc coupled with 3 phase induction motor suitable for operation on 400/415V, AC withcoupling mounted on channel iron base frame including nuts, bolts & washers, with PCC foundation, nuts, bolts & washers as per manufacturer\" instructions complete all as directed.Note: The quoted rate shall deemed to be included the cost of interconnecting armoured copper cable of suitable size between starter panel and pump set with suitable lugs, cable protection measures etc. |
| 28 | Supply, Install, Test & Commissioning of factory made indoor LT Panel board (Pump House Panel) cubical type floor mounting, dust and vermin proof made out of 2 mm thick CRCA sheet steel with angle iron base frame, free standing on cable duct with cable entry holes at the bottom suitable for operation on 440 Volts, AC 3 phase, 4 wire, 50Hz with 200 Amps rated copper Bus Bar,fully compartmentalized, vermin proof, painting with powder coating 7 tank process suitable for IP-52 protection including suitable PCC foundation as per manufacturer recommendation complete and comprising of the following:-INCOMERi) MCCB, 4 pole, 80 Amps, with ultimate breaking capacity of 25 KA at 415V, with thermal magnetic release, thermal overload setting- 01 NoOUTGOINGi) MPCB 4 pole 40 A, 415V, 25 KA- 03 Nos (For Pumps-02 Nos and Spare-01 No).ii) FASD starter suitable for pump-set upto 40 HP complete with single phase preventer, timer, contactor s, relays, push buttons, ON/OFF indicators etc- 02 NosBUSBAR200 A rated Al bus bar for 03 phases and neutral with colour coded heat shrinkable sleeve METERING & INDICATIONi) Ammeter,Digital type, with suitable Cts, selector switch (0-200A) - 01 setii) Voltmeter, Digital type with selector switch (0-500V) - 01 setiii) R-Y-B phase LED indicating lamp- 01 setiv) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled. |
| 29 | Upgradation of the existing SCADA software to incorporate management and control of New Pump House including develop and add the additional features as described below the Linking of the Automated Pump houses by altering the existing SCADA software including a)Development of libraries and screens for display of the schematic of the remote Pump houses b) Creation of additional soft keys for remote / manual operation of the pumps and motorized valves in the above mentioned pump houses. c) Modification of the Main SCADA screen to create a link to easily navigate to the newly developed PH schematic screen etc. as required. |
| 30 | Supply, Installation, Testing and Commissioning of Indoor type PLC based Slave Monitoring / Annunciating Control Panel made out of 2 mm thick CRCA sheet duly powder coated for control and monitoring of 04 Nos centrifugal pumps ,05 Nos Motorized butterfly valves, 02 nos. magnetic level sensors, 02 Nos Ultra Sonic Level Sensor, 02 Nos valves for priming valves, 02 Nos Pressure transmitters and 02 Nos air release Solenoid valves. The panel shall consist of the following equipments; (a) Water Level Sensing & Display (b) Pump On/Off (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Prevention (h) Manual Mode Operation The PLC based Panel shall consist of the following sub systems (i) 04 nos. Current transducers / energy meters with inbuilt mod bus communication port (ii) 01 no.PLC with following specifications; a. Redundant CPU and Redundant Digital inputs, outputs and analog inputs and outputs (as per system requirement + 25% spare capacity) b. 4 serial ports supporting open communication protocol |
| 31 | c. Programming software based on IEC to facilitate building of custom built function blocksd. Expandable upto 192 DI / DOs(iii) 01 no. HMI - 7\" (min) Graphical Touch screen multicolor having following minimum featuresa. 02 nos. serial ports and 01 no. USB port b. Floating point supportc. Built in RTC d. Bar Graph and image (bmp, jpeg files) e. Real time and historical Trending. Real time and historical alarms,(iv) 01 no. SMPS of 5 A rating (vi) 01 no.Suitable Surge Protection device suitable for 230V incoming supply(viii) Suitable no. of interposing relays24V D.C. coil rating and 5 Acontact rating(ix)1 KVA UPS / INVERTER with Sealed Maintenance free Batteries forpowering the panel for a minimum of 30 minutes in case of supplyfailure.(x) Transformer of suitable rating(xi) MCB of suitable rating(xii) Single Phase Preventer(xiii) Illuminated Push Buttons, Push Buttons and Indicator Lamps asper requirement(xiv) Selector Switches as per requirement(xv) Audio Visual Alarm Indicator(xvi)GPRS enabled wireless dual SIM card based communication module comprising of one Main and One standby Modem withsuitable antenna and data enabled SIM cards - 02 nos.(01 no. per modem) using 02 different service providers. The module should be programmed to automatically toggle between the two service providers based on the actual signal strength available. The quoted cost shall include the cost of communication for a period of 12 months from the date of completion. |
| 32 | Supply, Installation, Testing and Commissioning of Float type Point Level Sensor with the following specifications;Type: MagneticMagnet: Ring typeSwitch: Reed Switch (Epoxy sealed)Connecting Cable: Teflon |
| 33 | Supply, Installation Testing & Commissioning of Motor Actuated Butterfly Valve of 150 mm dia consisting of Quarter turn single phase Actuator and Wafer type butterfly valve with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Direct |
| 34 | Supply, Installation Testing & Commissioning of Motor Actuated Butterfly Valve of 100 mm dia consisting of Quarter turn single phase Actuator and Wafer type butterfly valve with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C.Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Direct |
| 35 | Supply, Installation Testing & Commissioning of pressure transmitter with following specification Power supply: 10-36 V DCProcess connection: G ½ “Enclosure: whether proof IP 65Process temperature: -0 to 60 CelsiusAccuracy: 1 % |
| 36 | Supply, Installing, Testing and Commissioning of Ultrasonic Level TransmitterRange : 0-5 meters,Accuracy : 0.5 % minimum,Supply Voltage : 24V dc, Output : 4-20 mAUltrasonic Frequency:75 kHz burst, rep. rate 96 msDelay at Power-up: 1.5 secondsTemperature Effect: Uncompensated: 0.2% of distance/°C&Compensated: 0.02% of distance/°CDelay at Power-up: 1.5 secondsResolution: 1.0 mmOutput Response Time: 100 ms to 2300 msMinimum Window Size: 20 mm Environmental Rating: Leak-proofdesign is rated IEC IP67; NEMA 6POperating Conditions: Temperature: –20 °C to 70 °C (–4 °F to 158 °F). |
| 37 | Supplying and fixing on wall / drawing through pipe 4 x 1.5 sq.mm. PVC insulated and PVC sheathed Armoured copper cable with suitable size of saddles etc complete etc as required. |
| 38 | Supplying and fixing on wall / drawing through pipe 6 x 1.5 sq.mm. PVC insulated and PVC sheathed armored copper cable with suitable size of saddles etc complete etc as required. |
| 39 | Supply and drawing through pipe/fixing on wall/surface/pipe 0.5mm 5 pair PVC insulated and PVC sheathed armored communication cable with suitable size of saddles etc complete. |
| 40 | Supply, Installation Testing & Commissioning of solenoid / motorized valve suitable for 25mm GI pipe for priming of pump including suitable bypass arrangementwith necessary GI fittings with following specifications:Size: 25 mm Pressure rating: 6 kg / sq. cm. |
| 41 | Supplying and fixing on wall / drawing through pipe 3 x 10 sq.mm. PVC insulated and PVC sheathed unarmoured copper cable with suitable size of saddles etc complete etc as required. |
| 42 | SEWAGE DISPOSAL |
| 43 | S & F HDPE DWC(Double wall corrugated) pipes confirming to IS 16098, of 200 mm internal dia pressure rating SN-8 fixed with rubber seal and copler required with and including suitable bends 90/60/45 degree etc single Y junction complete as required fixed as per manufacturer instruction laid in trenches for sewage lines all as specified and directed. Note ;- Rates included for pipe bends any size and type jn coupler adaptor required and net total length of pipe with fittings shall be measured for payment please. |
| 44 | ARBORICULTURE |
| 45 | Supply only suitable soil for lawn/bed/hedge etc as specified and directed. |
| 46 | M&L for brick edging along ourter faces of mehendi hedge and flower bed complete all as specified and directed. |
| 47 | Supply only manure (Cow dung) for bed/lawn/hedge etc all as specified and directed. |
| 48 | Development of the area by planting of mexicon grass with dibbling method by keeping the spacing of 30 centimeter between the tufts of grass including trenching the ground, watering rolling, moving (if required) and de-weeding complete all as specified and directed till the grass form a thick carpet free from weeds including the cost of labour, tools and tackles complete. |
| 49 | Supply and plantation of flowering bed with minimum 30cm spacing between the plants (with tantena plant) includig preparation of flower beds by doing all horticultural activities like trenching , watering , de-weeding etc, including the cost of labours, tools and tackles complete for a period till flower plants become live properly and flower bed takes proper form complete in all respect all as specified. |
| 50 | All as per item No 17.05 above but for flowering hence with minimum 3 plants per sqm feet (feet tantena plant) 30cm wide along the inner face of mehendi hedging. |
| 51 | Development and plantation of hedge ( with mehendi plant)30cm wide and 30cm high in two rows minimum 12 sticks per meter in a row including preparation of hedge beds by doing all horticultural activities, like trenching, watering, de-weeding etc, including the cost labours, tools and tackles complete for a period till hedges plants become live properly and hedge take proper form complete all as specified and directed. |
| 52 | Manning operation for maintenance of grass and flower beds for 6 months periods6 Months = 6 x 30 = 180 days |
| 53 | Supply and planting of below mentioned trees in 0.25-0.30 m poly bags with height 0.90-1.20 m including holes 1.20 m dia x 1.20 m deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the atio 2:1 (2 parts of stacked volume of earth reduction of 20 % with 1 part of stacked volume of sludge or manure after reduction by 8 % , flooding with water and removal of soil: |
| 54 | Kinnow |
| 55 | Jamun |
| 56 | Guava |
| 57 | Casoraina |
| 58 | Palm |
| 59 | Amaltas |
| 60 | Neem |
| 61 | Gulmohar |
| 62 | Kesia |
| 63 | Kamuj |
| 64 | Seesham |
| 65 | Ashok |
| 66 | Supply and planting of hedge shrubbery as directed by Engineer- in-charge including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm re-filling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 1:8 (8 parts of stacked volume of earth after reducing 20%with 1 part of stacked volume of sludge or manure after reduction by 8 %, flooding with water ,filling with earth if necessary, watering and finally fine dressing ,levelling etc. including stacking and disposal of material declared unserviciable and surplus earth by spreading and levelling as directed within a lead of 50 m and lift upto 1.0 m complete. |
| 67 | Maintenance of plants / hedges/ grass by weeding hosing, saucer making once in every month for plants/ hedge, once in every 15 days for carpet gass/ country grass /doob grass, burmuda grass; prunning dried branches once in every week, depositing the material at place as directed by Engineer-in-charge and planting the new plants in place of dead plants of same species and height tuning with dods wherever required by replacing the dead patches of grass with the same grass as required without extra cost to the deptt and as directed complete for all above works. |
| 68 | FURNITURE |
| 69 | Supply only Almirah Med Steel, as per drawing No. FD-1032, complete all as specified and directed. |
| 70 | Supply only Chair Dining JCO/ OR, as per drawing No. FD/MAP-II/05, complete all as specified and directed. |
| 71 | Supply only Chair Verandah JCO/ OR, as per drawing No. FD-256, complete all as specified and directed. |
| 72 | Supply only Chair School with hand board, as per drawing No. FD/E6/MAP/05 complete all as specified and directed. |
| 73 | Supply only Charpoy IP hard top, as per drawing No. FD/MAP-II/01, complete all as specified and directed. |
| 74 | Supply only Table Peg, as per drawing No. FD-384, complete all as specified and directed. |
| 75 | Supply only Shoe rack steel, as per drawing No. FD/E6/MAP/02(R), complete all as specified and directed. |
| 76 | Supply only Table Bed Side, as per drawing No. FD/E6/MAP/15(R), complete all as specified and directed. |
| 77 | Supply only Table Dining 1200mmx900mmx760mm, as per drawing No. FD/MAP-II/03 complete all as specified and directed. |
| 78 | Supply only Dressing Mirror Gents, as per drawing No. FD/E6/MAP/16, complete all as specified and directed. |
| 79 | MANNING & OPERATION OF LIFTS FOR 60 MONTHS POST COMPLETION OF WORK (REFER ANNEXURE-XIII) |
| 80 | Manning & Operation of fully automatic electrically operated passenger lift installed under this EPC contract of any make, type and 16 passenger - 08 Nos and 20 passenger -04 No, total 33 floors, speed 3m/sec, SS lift installed in the subject project as per annexure for supply and fix given above by placing 2 x lift operator in 2 shits of 8 hrs including Sunday and holiday (0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs) including taking care of all lifts from any pilerage or damage etc (Total 12 Nos lifts)+ 1 person at night including Sunday & holiday during & after the defects liability period of the project as under:- |
| 81 | 11 months after completion of work |
| 82 | 11 months after completion of BOQ Sl item No 19.02 here-in-before |
| 83 | 11 months after completion of BOQ Sl item No 19.03 here-in-before |
| 84 | 11 months after completion of BOQ Sl item No 19.04 here-in-before |
| 85 | 11 months after completion of BOQ Sl item No 19.05 here-in-before |
| 86 | 05 months after completion of BOQ Sl item No 19.06 here-in-before |
| 87 | Note: (a) The contractor shall employ lift operators with a minimum qualification of SSC pass (10th standard) from a Government-recognized institute/college. The operators must have adequate knowledge and a minimum of two (2) years of experience in lift operation. They shall be responsible for keeping the lift clean on a regular basis, all as directed.A total of five (05) operators are required per day. (b) The contractor shall pay wages to the employees through e-payment (Aadhaar-linked bank account). The credited amount to their bank accounts shall not be less than the minimum wages prescribed. The GE (Principal Employer) shall ensure that wages paid to the employees are not less than the rates fixed by the State Government or Central Government, whichever is higher. A monthly e-banking statement shall be furnished by the contractor to the GE (Principal Employer) and kept on record duly defaced.(c) It shall be the responsibility of the contractor to deposit the Employees Provident Fund (EPF) with the concerned authority as per prevailing rules. Proof of such deposits shall be submitted to the GE (Principal Employer) for verification and record. The quoted rates shall be deemed to include compliance with these provisions. In case the contractor fails to produce proof of EPF deposit, the same shall be recovered from his dues.(d) The contractor shall maintain all necessary registers as required under various Labour Law Rules, 2017. These registers shall be produced to the GE (Principal Employer) and to any officer deputed by the Central Labour Department for inspection.(e) In case of any abnormal noise or complaint, the lift shall be immediately switched off and the issue shall be reported to the Engineer-in-Charge.(f) The contractor shall not employ the same tradesmen continuously for more than eleven (11) months during the contract period.(g) The contractor shall provide two (02) sets of uniforms, one (01) pair of black shoes, and one (01) nameplate (to be worn on the chest) to each operator. The design of the uniform shall be approved. In case of failure, a penalty of ₹2,000/- per uniform shall be levied and recovered from the contractor\"s dues.(h) In case of failure due to absence of operating staff, the contractor shall be liable to pay compensation at twice the cost of a day\"s Manning & Operation, derived on a pro-rata basis from Sch ‘A’ quoted rates.(i) The contractor shall provide a board at a proper location near each building wing, clearly displaying the name of operators, name of the supervisor, and their mobile numbers (shift-wise).(j) The works covered under Schedule \"A\" shall be ordered on the contractor by the respective Garrison Engineer on a yearly basis. |
| 88 | ANNUAL COMPREHENSIVE MAINTENANCE OF LIFTS (REFER ANNEXURE-XIV) |
| 89 | Comprehensive Maintenance of lifts installed under this EPC contract including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes, door cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/liks, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover,\" Fire alarm, Firemen button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete wvith iluminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , iing of loose ralil bracket with necessary masonry work , cabin, minor repair of cabin light and minor repair of cabin fan, ensure safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing, two coats of Painting of Gear motor, Traction motor and ll mechanical parts which required painting all MS channels and Control panels using spray gun complete, dewatering of lift wells in case of any emergency arise complete for 8 Nos. Lifts of 16 Passenger capacity (G+32 Floors) through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by GE. |
| 90 | One year after expiry of defect liability period |
| 91 | One year after completion of BOQ Sl item No 20.02 here-in-before |
| 92 | One year after completion of BOQ Sl item No 20.03 here-in-before |
| 93 | Comprehensive Maintenance of lifts installed under this EPC contract including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes, door cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/liks, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover,\" Fire alarm, Firemen button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete wvith iluminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , iing of loose ralil bracket with necessary masonry work , cabin, minor repair of cabin light and minor repair of cabin fan, ensure safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing, two coats of Painting of Gear motor, Traction motor and ll mechanical parts which required painting all MS channels and Control panels using spray gun complete, dewatering of lift wells in case of any emergency arise complete for 4 Nos. Lifts of 20 Passenger capacity (G+32 Floors) through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by GE. |
| 94 | One year after expiry of defect liability period |
| 95 | One year after completion of BOQ Sl item No 20.06 here-in-before |
| 96 | One year after completion of BOQ Sl item No 20.07 here-in-before |
| 97 | Note: (i) Rates quoted under Sch A shall be for both materials and labour complete unless mentioned otherwise.(ii) After the expiry of the Defects Liability Period of 24 months from the certified date of completion of work, the Government reserves the right to instruct the contractor to carry out Comprehensive Maintenance Services of the lift (provided by him under Schedule \"A\") in accordance with the terms and conditions detailed in Schedule \"A\" and the enclosed specifications.In the event the Government exercises the above right, the Comprehensive Maintenance Service Contract (CMSC) shall be for a period of three (03) years starting from the date of expiry of the Defects Liability Period.(iii) The contractor shall enter into a Memorandum of Understanding (MoU) with the Original Equipment Manufacturer (OEM) for provision of the lift and its post-warranty/post-Defects Liability Period maintenance. This MoU shall be submitted at least six (06) months prior to the issue of the Completion Certificate of the main contract.(iv) The rates quoted under this Schedule \"A\" shall be deemed to include all materials and labour required for comprehensive maintenance, including all repairs and replacements.(v) This contract shall be operative for a period of three (03) years after the expiry of the Defects Liability Period, solely for the purpose of comprehensive maintenance of the lift.(vi) A qualified mechanic shall be available at the Lift Complaint Cell at all times to ensure the safe and smooth functioning of the lift.(vii) Rewinding of the motor, if required, shall be carried out by the contractor at no additional cost to the department.(viii) The detailed duty mechanic of the firm shall report daily to the Junior Engineer (JE) concerned at the Lift Complaint Cell, Navy Nagar, including on Sundays and holidays.(ix) In case the contractor fails to carry out minor repairs or replacements to keep the lift in running condition within 4 hours, the following penalty charges shall be applicable:Up to 12 hours – ₹1500/-Above 12 hours and up to 24 hours – ₹3000/-Above 24 hours – ₹4500/- per dayThe decision of the Garrison Engineer (GE) regarding whether a repair is minor or major shall be final, conclusive, and binding. |