| 1 | Demolishing RCC works i/c stacking of steel barand disposal of unserviceable materilas within 15 m lead as per direction of Engineer- in- charge |
| 2 | Earthwork in excavation in foundation trenches,including dressing of sides and ramming ofthe bottom i/c stacking of serviceable stones,disposal and removal of excation earth within a lead of 50m and lift of 1.50m complete as directed. (a) all kinds of soil ( ordinary soil/hard soil/dense soil) |
| 3 | Provding soiling with stone/best qaulity picked jhama brick, sand packed and laid to level in panel after preparing the subgrade as directed i/c all labour and materials and if necessary dewatering, complete. (b) Stone soiling 150mm |
| 4 | Providing for steel reinforcement in RCC work i/ccutting,bending,cranking and tying in position with binding wire,20 gauge,as shown in drawings,complete upto floor two level. (ii) Tor steel. |
| 5 | Providing centering and shutteringi/cstrutting , propping etc and removl of form for all heights complete and as directed by Engineer in charge. Foundation, footings, bases of columns, etc for mass concrete( using) |
| 6 | Providing & laying cement concrete in proportion 1:2:4corresponding to M150 ( 1-cement,2-sand,4-stone aggregates of 20mm and down graded)i/c curring etc complete (excluding shuttering and reinforcement) |
| 7 | Providing shuttering i/c centering for flat surface such as slabs,shelves,chajja and for vertical faces such as columns,walls,ends of beams etc with dressed plank not less than 25cm thick firmly firmly fixed etc complete as directed ( applicable upto 3.30m height). |
| 8 | Providing & laying ijn position specified grade of reinforcement cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work upto plinth level. (a) proportion 1:2:4 or M15 ( 1-cement,2-sand,4-stone aggregates of 20mm and down graded). |
| 9 | Earthwork in excavation in foundation trenches,including dressing of sides and ramming ofthe bottom i/c stacking of serviceable stones,disposal and removal of excation earth within a lead of 50m and lift of 1.50m complete as directed. (a) all kinds of soil ( ordinary soil/hard soil/dense soil) |
| 10 | Provding soiling with stone/best qaulity picked jhama brick, sand packed and laid to level in panel after preparing the subgrade as directed i/c all labour and materials and if necessary dewatering, complete. (b) Stone soiling 150mm |
| 11 | Providing for steel reinforcement in RCC work i/ccutting,bending,cranking and tying in position with binding wire,20 gauge,as shown in drawings,complete upto floor two level. (ii) Tor steel. |
| 12 | Centering and shutteringi/cstrutting , propping etc and removl of form for all heights complete and as directed by Engineer in charge. Columns, pillars, piers, abutments, posts and struts. |
| 13 | Providing & laying cement concrete in proportion 1:2:4corresponding to M150 ( 1-cement,2-sand,4-stone aggregates of 20mm and down graded)i/c curring etc complete (excluding shuttering and reinforcement) |
| 14 | Providing centering and shutteringi/cstrutting , propping etc and removl of form for all heights complete and as directed by Engineer in charge. Columns, pillars, piers, abutments, posts and struts. |
| 15 | Providing & laying cement concrete in proportion 1:2:4corresponding to M150 ( 1-cement,2-sand,4-stone aggregates of 20mm and down graded)i/c curring etc complete (excluding shuttering and reinforcement) |
| 16 | Earthwork in filling ( excluding rock) in trenches, plinth, sides, of foundaton etc in layers not exceeding20cm thick i/c breakingof clods consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. (a) with available excavated earth |
| 17 | Earthwork in filling ( excluding rock) in trenches, plinth, sides, of foundaton etc in layers not exceeding20cm thick i/c breakingof clods consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. b) with borrowed earth/stone dust carriage upto 5 km |
| 18 | Providing centering and shutteringi/cstrutting , propping etc and removl of form for all heights complete and as directed by Engineer in charge. Slabs, roofs, landings, balconies and access platform, shelves |
| 19 | Providing for steel reinforcement in RCC work i/ccutting,bending,cranking and tying in position with binding wire,20 gauge,as shown in drawings,complete upto floor two level. (ii) Tor steel. |
| 20 | Reinforcemnet cement concrete work in beams, slabs, roof having slope upto 15 degree, landings, balconies, shelevs, chajjas, lintels, banda, plain window sills, staircases and spiral stair cases above plinth level upto first floor level, excluding the cost centering, shuttering, finsihing and reinforcement. (b)Providing & laying cement concrete in proportion 1:2:4corresponding to M150 ( 1-cement,2-sand,4-stone aggregates of 20mm and down graded)i/c curring etc complete (excluding shuttering and reinforcement). ( b) M20 or 1:1.5:3 |
| 21 | Brick work with common brunt clay modular 1st class bricks in foundation and in plinth. (a) Cement mortar 1:4 |
| 22 | Providing first class brick in required thickness in cement mortar 1:4 (1-cement & 4 sand) i/c curring complete as directed. (b) Super structure. |
| 23 | Providing for steel reinforcement in RCC work i/ccutting,bending,cranking and tying in position with binding wire,20 gauge,as shown in drawings,complete upto floor two level.(ii) Tor steel. |
| 24 | Providing centering and shutteringi/cstrutting , propping etc and removl of form for all heights complete and as directed by Engineer in charge. Lintels , beams, plinth beam, griders, bressumers and cantilevr (using steel) |
| 25 | Reinforcemnet cement concrete work in beams, slabs, roof having slope upto 15 degree, landings, balconies, shelevs, chajjas, lintels, banda, plain window sills, staircases and spiral stair cases above plinth level upto first floor level, excluding the cost centering, shuttering, finsihing and reinforcement. (b)Providing & laying cement concrete in proportion 1:2:4corresponding to M150 ( 1-cement,2-sand,4-stone aggregates of 20mm and down graded)i/c curring etc complete (excluding shuttering and reinforcement) |
| 26 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/nooprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (d) with float glass panes 0f 6mm thickness ( weight not less than 15kg/sqm.) |
| 27 | Providing and fixingM,S grills of required pattern in frames of windows, etc with M S falts, square or round bars etc i/c priming coat with approved steel primer all complete. (b) Fixed of openings/wooden frames with rawl plugs screws etc . |
| 28 | Providing & fixing 12mm thick prelaminated partilce board flat pressed 3 layer of graded wood particle board conforming to IS:12823 Grade I type 2, in panelling fixed in aluminum door, windows, shutter unpartition with CP brass/stainless steel screw etc. complete as per archetechtural drawing and direction of in-engineer charge. ( b) pre-laminated particle board with decorative lamination on both side. |
| 29 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/nooprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (e) with float glass panes 0f 8mm th. |
| 30 | Providing 12mm thick cement plaster of mix. (b) proportion 1:4 |
| 31 | Tile work in skirting, risers of steps and dado upto 2m height over 12mthick bed of cement mortor 1:3 and jointed with grey cemnt @3.3kg/sqm, i/c pointing in white cemnet mixed with pigment of matching shed complete. |
| 32 | Provding soiling with stone/best qaulity picked jhama brick, sand packed and laid to level in panel after preparing the subgrade as directed i/c all labour and materials and if necessary dewatering, complete. (b) Stone soiling 150mm |
| 33 | Providing & laying vertified floor tiles in different sizes ( thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS:15622 of approevd make , in all colours and shades laid on 20mm thick cement mortor 1:4 ( 1 cement : 4 coarse sand ), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with whitecement and matching pigments etc., complete. (b) size of Tile 600 x600 mm) |
| 34 | Tile work in skirting, risers of steps and dado upto 2m height over 12mthick bed of cement mortor 1:3 and jointed with grey cemnt @3.3kg/sqm, i/c pointing in white cemnet mixed with pigment of matching shed complete. |
| 35 | Earthwork in excavation in foundation trenches,including dressing of sides and ramming ofthe bottom i/c stacking of serviceable stones,disposal and removal of excation earth within a lead of 50m and lift of 1.50m complete as directed. (a) all kinds of soil ( ordinary soil/hard soil/dense soil) |
| 36 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified i/c dewatering if necessary and curring complete ( shuttering where necessary shall be measured and paid separately) |
| 37 | Cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cemnt , including cement slurry, complete. (b) 40mm thick |
| 38 | Providing and fixing PVC pipes, having thermal stability for hot & cold water supply, i/c all PVC plain & brass threaded fittings. This includes jointing of pipes & fitting with one step PVC sovlent cement, trenching & testing of joints complete as per directionof Engineer-in-charge. (iii) 100mm outer diameter pipes. |
| 39 | Providing and fixing PVC pipes, having thermal stability for hot & cold water supply, i/c all PVC plain & brass threaded fittings. This includes jointing of pipes & fitting with one step PVC sovlent cement, trenching & testing of joints complete as per directionof Engineer-in-charge. (iii) 25mm outer diameter pipes. |
| 40 | Providing and fxing C.P Brass long nose bib cock of approved quality confirming to IS standards and weighting not less than 810 gms. (a) 15 mm nominal bore |
| 41 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for reception of pipes and fittings. |
| 42 | Providing and fixing vitreous china dual purose closet suitable foe use as squatting pan or European type water closet ( Anglo Indian W. C pan) with seat & lid fixed with C.P brass hinges and rubber buffers, 20 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20mm over flow pipe, with specials of standard make and mosquito proof coupling of approved design complete, i/c painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.Pflush bend. |
| 43 | Providing and fixing water closet squatting pan ( Indian type W.C pan) with 100mm sand Cast Iron P or S trap, 10 litre low level white P.V.C flushing cistern, i/c flush pipe, with manually controlled devic ( handle lever) confriming to IS:7231, with all fittings and fixtures complete, i/c cutting and making good the walls and flors wherever required: (a) white Vitreous china Orissa pattern W.C pan of size 580x440 mmm with integral type foot rests |
| 44 | Providing and fixing waste pipe for sink or wash basin i/c P.V.C waste fittings complete. (ii) 40mm |
| 45 | Providng & fixing fly proof wire gauze to windows. Clerestory windows & doors with MS flat 15x3 mm nuts & bolts complete. ( a) Galvanised MS wire gauge with 0.63 mm dia. Wire and 1.4 mm aperture on both sides. |
| 46 | Providng and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 47 | Wall painitng with acrylic emulsion paint of approved brand and manufacture to give an even shade. New work (two or more coats) |
| 48 | Providing and supplying casing capping including all elbow, tee, internal & external as directed by Engineer-in-charge |
| 49 | Providing & fitting square box as directed by Engineer-in-charge |
| 50 | Providing and fixing ceiling rose of approved make and design, conforming to IS:371 (latest), suitable for 230V single-phase supply, made of high-grade insulating material, complete with necessary connections, testing, and commissioning as per standard electrical practice, including all labour, materials, and tools required for proper completion of work |
| 51 | Providing, fixing, testing and commissioning of 100A, 4-pole, 415V, 50Hz, MCCB with adjustable thermal-magnetic release, breaking capacity not less than 25kA (Icu) at 415V, conforming to IEC 60947-2 / IS 13947-2, including necessary connections, lugs, hardware, and mounting arrangement as required, complete in all respects. |
| 52 | Providing & fitting MCCB incloser as directed by Engineer-in-charge |
| 53 | Providing and fixing 10A, single-pole, modular type switch, ISI marked, complete with suitable modular plate and box, including connections, testing, and commissioning as required. |
| 54 | Providing and fixing 16 Amp, 1-way modular switch, ISI-marked, complete with suitable size modular plate, GI box, and cover, including all connections, testing, and commissioning as required |
| 55 | Providing and fixing 16 Amp modular socket outlet, complete with suitable modular plate and box, including necessary wiring connections, testing, and commissioning as required. |
| 56 | Providing and fixing factory-made modular switch box of approved make, suitable for housing 3-way modular switches, with matching front plate, including cutting, fixing, connection, and making good the surface, complete in all respects as per IS standards |
| 57 | Providing and fixing 12-way modular switch box with suitable front plate, made of high-quality powder-coated metal/plastic, complete with necessary accessories, including cutting, chasing, fixing, and making good the surface, as per approved design and specifications. |
| 58 | \"Providing and fixing factory-made, ISI-marked, rust-proof modular switch box of suitable depth, made of powder-coated mild steel/polycarbonate, complete with 6-module front plate, including necessary accessories, screws, and proper alignment. The work shall include cutting, chasing, and making good the wall surface, as required, for flush/concealed mounting, complete in all respects as per approved design and direction of the Engineer-in-Charge.\" |
| 59 | Providing & fitting screw 2 and 1/2 inch as directed by Engineer-in-charge |
| 60 | Providing & fitting Cable clip flat type as directed by Engineer-in-charge |
| 61 | Providing & fitting Modular fan regular as directed by Engineer-in-charge |
| 62 | Providing & fitting MCB 4-pole 63 Amp. as directed by Engineer-in-charge |
| 63 | Providing & fitting MCB Single pole 20 Amp. as directed by Engineer-in-charge |
| 64 | Providing & fitting MCB single pole 16 Amp. as directed by Engineer-in-charge |
| 65 | Providing, supplying, and fixing ceiling fan of approved make and model, complete with down rod, blades, motor, canopy, and all necessary accessories, including wiring connections with suitable size copper conductor, testing, and commissioning. The work shall include mounting on the ceiling hook/anchor fastener, balancing of blades, and ensuring smooth and noiseless operation. The fan shall conform to IS:374 or relevant standards, with sweep size not less than 1200 mm, operating voltage 230V ±10%, and complete in all respects as directed by the Engineer-in-Charge |
| 66 | Providing, installation, testing and commissioning of exhaust fan of approved make and model, complete with all accessories, including necessary mounting frame, fasteners, electrical connections, and making good any damage to the wall/structure, as per manufacturer’s specifications and directions of the Engineer-in-Charge.\" |
| 67 | Providing and fixing 4-core, [conductor material], [cross-sectional area] sq.mm, XLPE/PVC insulated, steel wire armoured, PVC sheathed cable, suitable for [rated voltage] volts, including laying in trench/duct/clamping on wall with necessary clamps, saddles, and terminations as required, complete in all respects. |
| 68 | P&F of 4 sq.mm FRLS PVC insulated copper conductor, single-core cable of approved make, 1100V grade, laid in existing conduit/duct, with proper terminations at both ends, complete in all respects as per IS 732 and direction of Engineer-in-Charge |
| 69 | Providing and fixing 2.5 sq.mm single core, PVC insulated, copper conductor wire of approved make, conforming to IS:694, in existing/recessed/surface PVC conduit, including connections, testing and commissioning as required. |
| 70 | Providing and fixing LED tube light, 20 Watt, complete with high-efficiency driver, polycarbonate housing, and integrated batten, suitable for wall/ceiling mounting, including all necessary connections, testing, and commissioning as per manufacturer’s specifications and directions of the Engineer-in-Charge. |
| 71 | Providing and fixing LED tube light, 15 Watt, complete with high-efficiency driver, polycarbonate housing, and integrated batten, suitable for wall/ceiling mounting, including all necessary connections, testing, and commissioning as per manufacturer’s specifications and directions of the Engineer-in-Charge. |
| 72 | Providing and fixing LED tube light, 12 Watt, complete with high-efficiency driver, polycarbonate housing, and integrated batten, suitable for wall/ceiling mounting, including all necessary connections, testing, and commissioning as per manufacturer’s specifications and directions of the Engineer-in-Charge. |
| 73 | Providing and fixing 0.75 sqmm single-core PVC insulated copper earthing wire, complete with necessary accessories, clamps, and terminations, as per standard specifications and directions of the engineer-in-charge. |
| 74 | Providing, supplying, and fixing of 60 kV class Lightning Arrester, complete with base, clamps, connectors, and all necessary accessories, conforming to IS/IEC standards, including transportation, installation, testing, and commissioning at site, as per engineer-in-charge’s direction. |
| 75 | Providign and fitting DB-Box 18 way fo approved brand as directed by Engineer-in-charge |
| 76 | Providing and placing on terrace ( at all floor levels) polyethylene water storage tank,IS :12701 med , with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes butwithout fittings and the base suport for tank. |
| 77 | Providing and fixing 1.5 sq.mm PVC insulated, single-core, copper conductor wire of approved make, conforming to IS:694, in existing PVC conduit/ casing capping, including connections, testing and commissioning as required, complete in all respects |