| 1 | Providing Scaffolding for vimanam raja gopuram with non flammebable materials wherever necessary for main form work and by providing coconut keeth as covering the areas & plat form for inspection etc all complete. |
| 2 | Vimanam Height upto 15\"-0\" |
| 3 | Vimanam Height upto 25\"-0\" |
| 4 | Gopurams upto 50\" - 0\" height |
| 5 | Dismantling Lime Concrete |
| 6 | Labour charge for old stone removing |
| 7 | Pavukkal, |
| 8 | Ullvari |
| 9 | Uthiram |
| 10 | Labour charge for old stone Fixing |
| 11 | Pavukkal |
| 12 | Ullvari |
| 13 | Uthiram |
| 14 | Clean removal of lime plaster from walls, |
| 15 | Dismantling Plain Cement Concrete |
| 16 | Dismantling the Pressed Tiles & Weathering Course Roof finish in cement mortar |
| 17 | Dismantling of Brick / Stone Masonry in lime mortar walls under 3m high |
| 18 | Brick work in Cement Mortar 1:5 mix using country bricks 83/4\"x43/8\"x23/4\" size inculding curing, scaffolding etc. complete complying with std. specification |
| 19 | upto basement |
| 20 | Above basement |
| 21 | Painting with multicolour (Panchavarnam) good water based exterior emulson paints complete for the Vinamans/Gopurams, including cost and conveyance of all materials, lobour chargesincluding Artist painter, working in heights, lifting of material,cost of brushes etc, complete-which including all extra for foldings-100sft, superficial area. |
| 22 | Gopurams upto 15\" - 0\" height |
| 23 | Gopurams upto 25\"-0\" height |
| 24 | Plastering with Lime mortar 1:1.5 (One of Lime and One and Half Msand),12mm thick including cost and conveyance of all materials and all labour charges,curing etc,complete complying with standard specifications. |
| 25 | Thorough scrapping of old plastered surface |
| 26 | Painting two Coats Exterior Emulsion or egavarnam water Based painting Included cost of all materials and all labour charges etc,. complete as per stantard specification. |
| 27 | Weathering course with brick jelly lime concrete using 20mm brickjelly with pure slacked lime over R.C.C. roof slab in the proportionof 32:12.5 and well watering consolidated with wooden beaters toslop including cost and conveyance of materials to site and labour charges etc |
| 28 | Finising the top of the roof with one course of pressed tiles of size 20X20X2cm over a bed of Combination mortor1:1:3 12mm thick mixed with water proof compound at 2% b weight of cement including cost and conveyance of all materials to site and all labour charges etc |
| 29 | Restoration by providing herbal water wash and approrimats methodology to restore the originalities of the existing granite structure inclusive of hire charges scaffolding arrangements conveyance charges for tools & plants and machinaries to the workship spot and cleaning the site after completion of work etc |
| 30 | Pointing with Lime mortar 1:1.5 including all tools and plants and labour etc all complete for cut stone masonry. |
| 31 | Earth work excavation and depositing on bank with in initial lead of 10 m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, earth mixed with small sized boulders and hardgravelly soil as per SS 20B |
| 32 | Supplying and Filling with foundation and basement with M sand in 15cm. Thick layers well rammed & consolidated, including watering, complying with std.specification etc complete. |
| 33 | Paving with cut stone flooring using cut stone of size 600x600mm and 100mm thick and all the sides are machine cutting, top surfaceis neatly dressed and pointing with lime mortar 1:1.5 including all materials and labour charges |
| 34 | Supplying and fixing teak wood temple type door including all materials, labour charges for manufacturing and fixing I position including all furniture fittings etc complete with std specifications. |
| 35 | Painting two coats for new wood works such as other similar works etc, complete complying with std specification |
| 36 | Painting two coats for old wood works such as other similar works etc, complete complying with std specification |
| 37 | Plain cement concrete 1:5:10 (One cement, five sand and ten hard broken granite stone jelly) using 40mm HBG metel as foundation concrete including dewatering wherever necessary and laid in layers of not more than 15cm. thick complying with std specification. |
| 38 | Providing and laying in position, Standardised Concrete Mix M20 Grade in accordance with IS 456:2000 using 20mm and down graded hard broken granite stone jelly for all rcc works with minimumm cement content 325Kg/m3 and maximum water cement ratio of 0.55, including admixture(plasticiser /super plasticiser) in recommanded proportions as per IS 9103 to acclerate, retard setting of concrete, improve workability with out i paring strength and durability with about (5 cum) 7730 Kg of 20mm machine crushed stone jelly and with about (3.3 Cum) 5156 Kg of 10 12mm machine crushed stone jelly and with about (4.79cum) 7670 Kg of sand, but excluding cost of reinforcement grill and fabrication charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing etc and providing fixtures like fan clamps in RCC floor/ roof slabs wherver necessary without claming extra complete complying std specification and also directed by departmental officers. The coarse and fine aggregates to be used should comply with requirements of IS standard |
| 39 | A) for Sub structure |
| 40 | Centering for soffits of reinforced cement concrete slabs, plain surface including strutting 3 meter height using MS plates of size 90cmx60cm and 10 gauge stiffen and with welded mild steel angles of size 25x25x3mm laid over silver oak |
| 41 | A) For Basement |
| 42 | Supplying, Fabrication and placing in position ofM.S. or RTS rods reforcement grill in position for all RCC works including cost of steel rods and binding wire etc., complete |
| 43 | Supplying and fixing MS grills to window and ventilator including the cost of necessary scrub and applying priming cost paint etc., complete. |
| 44 | Supplying and fixing of stainless steel Grill including the cost andconveyance of all materials and fixing in position including priming coat etc complete. |
| 45 | Painting two coats for new iron works over the one coat of primer such as iron bars flats and other similar works etc, complete complying with std specification |
| 46 | Painting two coats for old iron works over the one coat of primer such as iron bars flats and other similar works etc, complete complying with std specification |
| 47 | Supply and fing by drilling holes and not punching for roofing with POLYCARBONATE SHEET of 6mm thick of best approved quality with required size with curved shape and white ridge sheet with necessary bolts and nuts with bitumen washers including cutting the sheet to the required sie found necessary during eecution etc complete complying with standard specification |
| 48 | Random Rubble masonry work in Lime Mortor1:1.5 (One of cement and five of M-sand) Using selected stones and bond stones in foundation and basement including dewatering wherever necessary proper setting, curing etc., complete in all respects complying with relevant standard Specifications. The lime used should be sourced from Pollachi which is highly iron fortified and suitable for structural and masonry works. |
| 49 | Upto G.L |
| 50 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in existing Powder coated MS Duct with door arrangments on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 14 SWG TC wire for Open MS duct Light point/fan point (for electronic regulator) (5points /Coil) Lower End.DATA-1 |
| 51 | Supply and fixing of single box type 1 x 20 W single LED fitting complete with TW round blocks on wall or ceiling with bulb with PVC unsheathed Copper leads from terminals to the fitting. DATA 2 SD.442 |
| 52 | Supply and fixing of 1x40W LED Battern with LED (Higher end) on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting DATA-3 |
| 53 | Supply and fixing of fancy glass shade and 15W LED BH point.(SD-80) |
| 54 | Supply and fixing of fancy glass shade and 7W/9W LED bulb.(SD79) |
| 55 | Supply and fixing of 50 W flood light with necessary wall grouting clamps with fixing bolts on ceiling with PVC unsheathed copper Nos leads from terminals to the fitting (Higher end).DATA-4 |
| 56 | Supply and fixing of 100W flood light with integrated driver with necessary wall grouting clamps with fixing bolts on ceiling with PVC unsheathed copper leads from terminals to the fitting (Higher end).DATА-5 |
| 57 | Supply and fixing of 1 no.6A two module 5 pin socket, 1 no. 6A one module switch on suitable module surface mounting Box (GI) with module cover plate (plastic) on wall with connections.Lower End (SD 375) |
| 58 | Supply and fixing of 2 nos.6A two module 5 pin socket, 2 nos. 6A one module switch on suitable module surface mounting Box (Plastic) with module cover plate (plastic) on wall with connections.Lower End (SD 381) |
| 59 | Supply and fixing of 1 no.6/16A two module socket, 1 no. 16A one module switch on suitable module surface mounting Box (GI) with module cover plate (plastic) on wall with connections. Higher End (SD 401) |
| 60 | Supply and fixing of 450 mm (18\") sweep wall mounting fan (Higher end) on suitable special type clamps with bolts nuts and nitrile rubber over the stone surface with necessary arrangements and testing complete.DATА-6 |
| 61 | Supply and fixing of 375mm(15\") sweep (lightduty) AC exhaust fan complete with necessary wall opening and makingof the wall.(SD116) |
| 62 | Supply and fixing of louvers shutters arrangements for 375mm (15\") sweep light duty AC Exhaust fan.(SD-121)- |
| 63 | Supply and run of 35mm x 20mm powder coated duct with door arrangements complete with MS angle and bolt & nuts Complete.DATA-7 |
| 64 | Supply and run of 35mm x 45mm powder coated duct with door arrangements complete with MS angle and bolt & nuts Complete.DATA-8 |
| 65 | Supply and fixing of MS clamps of size 114\" x 14\" on pillar with suitable Bolt / nuts and painting of suitable colour. DATA-9 |
| 66 | Supply and run of 2 of 1.5 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC pipe on the existing cable tray with suitable clamps.DATA-10 |
| 67 | Supply and run of 2, of 2.5 sq.mm (36/0.3) PVC insulated SC unsheated copper conductor of 110V grade in suitable PVC rigid pipe the existing duting with continous earth wire connection by 2.5 sq mm PVC insulated SC unsheated copper wire. |
| 68 | Supply and run of 2 of 4 sq.mm (36/0.3) PVC inulated, Sciolppen unsheated copper conductor of 110V grade insuitable PVC rigid pipe , the existing duting with continous earth wire connection by 23 sqmm PVC insulated SC unsheated copper wire.DATA-12 |
| 69 | Supply and clamping of 4 x 16 sq.mm PVC LTUG armoured Alu cable on post or on wall with MS Clamps.(SD 204) |
| 70 | Supply and fixing of 8 way single pole and neutral MCB sheet steelenclosure distribution board with double door (metal) with 1 no.40A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCBas outgoing on suitable angle iron frame on wall with earth connection only. Higher End (SD 522) |
| 71 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End.(SD-527) |
| 72 | Supply and fixing of 6 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal door) with I no. 63A 4P MCB Isolator as incoming and 18 nos. 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with earth connection only. Higher End.DATA-13 |
| 73 | Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0,75 metre and refilling the earth to make good.(SD-669) |
| 74 | Supply and clarnping of 3 1/2 x 35sq.mm, PVC LTUG armoured cable on post or on wall with MS clamps.(SD-206) |
| 75 | Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection (SD-165) |
| 76 | Supply and providing cable end termination of 3 1/2x35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminiumcable sockets by crimping etc with electrical connection complete.(SD-224) |
| 77 | supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. dia GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .(SD 457) |
| 78 | supply and fixing of 65 mm dia. (2-1/2\") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 2 nos 30W LED street light fitting with LED (Higher end) with 1 metre 25mm dia. GI pipes (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour.DATA-14 |
| 79 | Supply and clamping of 4 x10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.(SD-203)(For Street Light) |
| 80 | Supplyand laying of 4x10sq.mm PVC armoured LTUG cable inatrench to be excavated at a depth of 0.75 metre putting 0.15metre layer of sandand covering the cable completely with brick sandsand and refilling theearthto make good(SD-180) |
| 81 | Supply and fixing of brass cable gland for 4 x 10 sq.mm. PVC LTUG armoured cable with earth connection.DATA-16 |
| 82 | Supply and clamping of 2x10 sq.mm. PVC LTUG armoured cableon post or on wall with MS clamps.(SD-199) |
| 83 | Supply and Laying of 2 x 10 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.DATA -17 |
| 84 | Supply and fixing of brass cable gland for 2 x 10 sq.mm. PVC armoured LTUG cable with earth connection.(SD-160) |
| 85 | Supply and fixing of 100 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only.(SD-658) |
| 86 | Supply and fixing of 100A (500V) 3 Phase meter Box fabricated with 16 SWG CRCA Powder coated MS box sheetcomprising of with 3 nos.of 100A fuse units, 1 no. 100A FP MCCB.provision for fixing TNEB meter with inter connections and with required accessories on wall complete.(Higher End) .DATA-18 |
| 87 | Supply and fixing of 4 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with I no. 40ADP MCB Isolator as incoming and 4 nos. 6A to 32A SP MСВ a outgoing on wall with earth connection only. (Higher End) DATA-19 |
| 88 | Supply and fixing of 6 way Vertical Triple pole and neutral MCСВ sheet steel enclosure distribution board (with MCCB Incomer) with double door (metal door) with 1 no, 160 A 4 P MCCB switch as incoming and nos. 63А ЗР МСВ, 6 nos. 6A to 32A SP MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End (SD 609) |
| 89 | Earthing as per the PWD standard with an earth electrode of 2mt class B\" GI pipe of dia not less than 32mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. (SD 222) |
| 90 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVO rigid pipe on wall/floor / ground for earth connection (SD372) |
| 91 | sub total |
| 92 | GST 18% Please Enable Macros to View BoQ information |